Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Respir J ; 21(6): 1050-68, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12797503

RESUMO

Indirect challenges act by causing the release of endogenous mediators that cause the airway smooth muscle to contract. This is in contrast to the direct challenges where agonists such as methacholine or histamine cause airflow limitation predominantly via a direct effect on airway smooth muscle. Direct airway challenges have been used widely and are well standardised. They are highly sensitive, but not specific to asthma and can be used to exclude current asthma in a clinic population. Indirect bronchial stimuli, in particular exercise, hyperventilation, hypertonic aerosols, as well as adenosine, may reflect more directly the ongoing airway inflammation and are therefore more specific to identify active asthma. They are increasingly used to evaluate the prevalence of bronchial hyperresponsiveness and to assess specific problems in patients with known asthma, e.g. exercise-induced bronchoconstriction, evaluation before scuba diving. Direct bronchial responsiveness is only slowly and to a modest extent, influenced by repeated administration of inhaled steroids. Indirect challenges may reflect more closely acute changes in airway inflammation and a change in responsiveness to an indirect stimulus may be a clinically relevant marker to assess the clinical course of asthma. Moreover, some of the indirect challenges, e.g. hypertonic saline and mannitol, can be combined with the assessment of inflammatory cells by induction of sputum.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica/normas , Padrões de Prática Médica/normas , Testes de Função Respiratória/normas , Asma/complicações , Asma/fisiopatologia , Testes de Provocação Brônquica/efeitos adversos , Testes de Provocação Brônquica/tendências , Humanos , Estimulação Física/efeitos adversos , Padrões de Prática Médica/tendências , Reprodutibilidade dos Testes , Testes de Função Respiratória/efeitos adversos , Testes de Função Respiratória/tendências , Sistema Respiratório/efeitos dos fármacos , Sistema Respiratório/fisiopatologia , Estimulação Química
2.
J Comput Assist Tomogr ; 16(2): 182-8, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1545014

RESUMO

Correlation of imaging and anatomic findings in seven men with abdominal aortic graft prostheses (four "end-to-end" anastomoses and three "end-to-side" anastomoses) was done to compare the value of different imaging modalities in detecting postoperative complications, especially aortic anastomotic pseudoaneurysms (AAPs). In all cases, angiographic and CT studies were carried out. In six patients ultrasound and MR examinations were also performed. Anatomic verification was obtained by surgery in six patients and autopsy in one case. Five patients had an AAP (four at surgery and one at autopsy), one had a true abdominal aortic aneurysm above the anastomosis, and one a nondetectable abnormality of the aortic suture line. Digital subtraction angiography diagnosed one of five AAPs, missed the true aneurysm in the sixth patient, and was normal in the patient without any aneurysm. Computed tomography correctly diagnosed the five AAPs and the true aneurysm and was normal in the last patient. Ultrasound correctly diagnosed the AAPs in three of four patients, incorrectly diagnosed an AAP in the patient who had the true aneurysm, and was normal in the patient without any aneurysm. Magnetic resonance diagnosed four of four AAPs and the true aneurysm and was normal in the last patient. Computed tomography seems to be the best imaging modality with which to diagnose and evaluate an aortic AAP in patients with aortoiliofemoral graft prosthesis.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma Aórtico/diagnóstico , Prótese Vascular , Idoso , Anastomose Cirúrgica , Angiografia Digital , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Aortografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada por Raios X , Ultrassonografia
3.
Ann Cardiol Angeiol (Paris) ; 37(1): 39-44, 1988 Jan.
Artigo em Francês | MEDLINE | ID: mdl-3278669

RESUMO

In reference to a personal series of 100 partial interruptions of the inferior vena cava (74 clips, 11 Mobin-Uddin umbrellas, 15 Greenfiled's filters), the authors analyze the criteria of choice in various procedures where the mortality, morbidity and sequellae remain low. In light of these results, the current place of surgery in the prevention of pulmonary embolism is discussed, in cases where anticoagulant therapy is contraindicated, inadequate or has failed.


Assuntos
Veia Cava Inferior/cirurgia , Constrição/instrumentação , Estudos de Avaliação como Assunto , Hemofiltração/instrumentação , Humanos , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA