Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 14(2): e009203, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33591816

RESUMO

Cardiac sarcoidosis is a component of an often multiorgan granulomatous disease of still uncertain cause. It is being recognized with increasing frequency, mainly as the result of heightened awareness and new diagnostic tests, specifically cardiac magnetic resonance imaging and 18F-fluorodeoxyglucose positron emission tomography scans. The purpose of this case-based review is to highlight the potentially life-saving importance of making the early diagnosis of cardiac sarcoidosis using these new tools and to provide a framework for the optimal care of patients with this disease. We will review disease mechanisms as currently understood, associated arrhythmias including conduction abnormalities, and atrial and ventricular tachyarrhythmias, guideline-directed diagnostic criteria, screening of patients with extracardiac sarcoidosis, and the use of pacemakers and defibrillators in this setting. Treatment options, including those related to heart failure, and those which may help clarify disease mechanisms are included.


Assuntos
Arritmias Cardíacas/etiologia , Cardiomiopatias/complicações , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Sarcoidose/complicações , Arritmias Cardíacas/fisiopatologia , Humanos
3.
Europace ; 11(7): 949-53, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19546189

RESUMO

AIMS: Reference values exist for endocardial but not for epicardial (EPI) substrate mapping in cases of cardiomyopathy-associated ventricular tachycardia. We sought to establish such values for EPI electrogram voltage, including areas with overlying fat. METHODS AND RESULTS: Ten patients (six males) undergoing cardiac surgery were studied. After opening the pericardium, the distal bipole of an electrophysiology catheter was placed tangential to the EPI surface to obtain an electrogram recording. The bipole was tangentially rotated 90 degrees and the higher of the two amplitudes (mV) was taken as the local amplitude. Recordings were taken from normal left and right ventricular myocardium (n = 26 data points each), over thick (> or = 0.5 cm) fat at both ventricular bases (n = 16) and thin (<0.5 cm) fat at the mid-ventricular level (n = 32). A total of 100 recordings (mean 10/patient) were analysed. Four patients underwent valvular surgery, three bypass surgery, and three combined procedures. Mean age was 61.7 +/- 10.4 years and mean left ventricular ejection fraction was 46 +/- 12%. Electrogram amplitude was inversely related to EPI fat thickness. Over thick fat, 31% of recordings were <0.5 mV. CONCLUSION: Human EPI electrogram amplitude varies by ventricular chamber and significantly by EPI fat thickness. A cut-off of 0.5 mV to define 'scar' will include normal areas with thick overlying fat. EPI substrate maps should include data on EPI fat thickness for higher specificity.


Assuntos
Tecido Adiposo/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Pericárdio/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA