Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
Neuropharmacology ; 247: 109862, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38325770

RESUMO

Adenosine A2A-receptors (A2AR) and dopamine D2-receptors (D2R) are known to work together in a synergistic manner. Inhibiting A2ARs by genetic or pharmacological means can relief symptoms and have neuroprotective effects in certain conditions. We applied PET imaging to evaluate the impact of the A2AR antagonist KW6002 on D2R availability and neuroinflammation in an animal model of Parkinson's disease. Male Wistar rats with 6-hydroxydopamine-induced damage to the right striatum were given 3 mg/kg of KW6002 daily for 20 days. Motor function was assessed using the rotarod and cylinder tests, and neuroinflammation and dopamine receptor availability were measured using PET scans with the tracers [11C]PBR28 and [11C]raclopride, respectively. On day 7 and 22 following 6-OHDA injection, rats were sacrificed for postmortem analysis. PET scans revealed a peak in neuroinflammation on day 7. Chronic treatment with KW6002 significantly reduced [11C]PBR28 uptake in the ipsilateral striatum [normalized to contralateral striatum] and [11C]raclopride binding in both striata when compared to the vehicle group. These imaging findings were accompanied by an improvement in motor function. Postmortem analysis showed an 84% decrease in the number of Iba-1+ cells in the ipsilateral striatum [normalized to contralateral striatum] of KW6002-treated rats compared to vehicle rats on day 22 (p = 0.007), corroborating the PET findings. Analysis of tyrosine hydroxylase levels showed less dopaminergic neuron loss in the ipsilateral striatum of KW6002-treated rats compared to controls on day 7. These findings suggest that KW6002 reduces inflammation and dopaminergic neuron loss, leading to less motor symptoms in this animal model of Parkinson's disease.


Assuntos
Doença de Parkinson , Purinas , Ratos , Masculino , Animais , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/tratamento farmacológico , Dopamina , Receptor A2A de Adenosina/metabolismo , Doenças Neuroinflamatórias , Adenosina/metabolismo , Racloprida , Ratos Wistar , Oxidopamina/toxicidade
2.
Mol Imaging Biol ; 26(2): 351-359, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38263484

RESUMO

PURPOSE: Estrogen receptors (ER) are implicated in psychiatric disorders. We assessed if ER availability in the human brain could be quantified using 16α-[18F]-fluoro-17ß-estradiol ([18F]FES) positron emission tomography (PET). PROCEDURES: Seven post­menopausal women underwent a dynamic [18F]FES PET scan with arterial blood sampling. A T1-weighted MRI was acquired for anatomical information. After one week, four subjects received a selective ER degrader (SERD), four hours before the PET scan. Pharmacokinetic analysis was performed using a metabolite-corrected plasma curve as the input function. The optimal kinetic model was selected based on the Akaike information criterion and standard error of estimated parameters. Accuracy of Logan graphical analysis and standardized uptake value (SUV) was determined via correlational analyses. RESULTS: The reversible two-tissue compartment model (2T4k) model with fixed K1/k2 was preferred. The total volume of distribution (VT) could be more reliably estimated than the binding potential (BPND). A high correlation of VT with Logan graphical analysis was observed, but only a moderate correlation with SUV. SERD administration resulted in a reduced VT in the pituitary gland, but not in other regions. CONCLUSIONS: The optimal quantification method for [18F]FES was the 2T4k with fixed K1/k2 or Logan graphical analysis, but specific binding was only observed in the pituitary gland.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Humanos , Feminino , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/metabolismo , Estradiol , Receptores de Estrogênio/metabolismo , Hipófise/metabolismo
3.
Eur J Nucl Med Mol Imaging ; 51(4): 1050-1059, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37975887

RESUMO

PURPOSE: Accurate preoperative localization is imperative to guide surgery in primary hyperparathyroidism (pHPT). It remains unclear which second-line imaging technique is most effective after negative first-line imaging. In this study, we compare the diagnostic effectiveness of [11C]methionine PET/CT, [11C]choline PET/CT, and four dimensional (4D)-CT head-to-head in patients with pHPT, to explore which of these imaging techniques to use as a second-line scan. METHODS: We conducted a powered, prospective, blinded cohort study in patients with biochemically proven pHPT and prior negative or discordant first-line imaging consisting of ultrasonography and 99mTc-sestamibi. All patients underwent [11C]methionine PET/CT, [11C]choline PET/CT, and 4D-CT. At first, all scans were interpreted by a nuclear medicine physician, and a radiologist who were blinded from patient data and all imaging results. Next, a non-blinded scan reading was performed. The scan results were correlated with surgical and histopathological findings. Serum calcium values at least 6 months after surgery were used as gold standard for curation of HPT. RESULTS: A total of 32 patients were included in the study. With blinded evaluation, [11C]choline PET/CT was positive in 28 patients (88%), [11C]methionine PET/CT in 23 (72%), and 4D-CT in 15 patients (47%), respectively. In total, 30 patients have undergone surgery and 32 parathyroid lesions were histologically confirmed as parathyroid adenomas. Based on the blinded evaluation, lesion-based sensitivity of [11C]choline PET/CT, [11C]methionine PET/CT, and 4D-CT was respectively 85%, 67%, and 39%. The sensitivity of [11C]choline PET/CT differed significantly from that of [11C]methionine PET/CT and 4D-CT (p = 0.031 and p < 0.0005, respectively). CONCLUSION: In the setting of pHPT with negative first-line imaging, [11C]choline PET/CT is superior to [11C]methionine PET/CT and 4D-CT in localizing parathyroid adenomas, allowing correct localization in 85% of adenomas. Further studies are needed to determine cost-benefit and efficacy of these scans, including the timing of these scans as first- or second-line imaging techniques.


Assuntos
Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Humanos , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Metionina , Colina , Estudos de Coortes , Estudos Prospectivos , Glândulas Paratireoides , Tecnécio Tc 99m Sestamibi , Racemetionina
4.
Cancers (Basel) ; 15(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37958347

RESUMO

The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.

5.
Cancers (Basel) ; 15(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37894340

RESUMO

MRI is the gold standard for treatment response assessments for glioblastoma. However, there is no consensus regarding the optimal interval for MRI follow-up during standard treatment. Moreover, a reliable assessment of treatment response is hindered by the occurrence of pseudoprogression. It is unknown if a radiological follow-up strategy at 2-3 month intervals actually benefits patients and how it influences clinical decision making about the continuation or discontinuation of treatment. This study assessed the consequences of scheduled follow-up scans post-chemoradiotherapy (post-CCRT), after three cycles of adjuvant chemotherapy [TMZ3/6], and after the completion of treatment [TMZ6/6]), and of unscheduled scans on treatment decisions during standard concomitant and adjuvant treatment in glioblastoma patients. Additionally, we evaluated how often follow-up scans resulted in diagnostic uncertainty (tumor progression versus pseudoprogression), and whether perfusion MRI improved clinical decision making. Scheduled follow-up scans during standard treatment in glioblastoma patients rarely resulted in an early termination of treatment (2.3% post-CCRT, 3.2% TMZ3/6, and 7.8% TMZ6/6), but introduced diagnostic uncertainty in 27.7% of cases. Unscheduled scans resulted in more major treatment consequences (30%; p < 0.001). Perfusion MRI caused less diagnostic uncertainty (p = 0.021) but did not influence treatment consequences (p = 0.871). This study does not support the current pragmatic follow-up strategy and suggests a more tailored follow-up approach.

6.
Pharmaceuticals (Basel) ; 16(10)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37895910

RESUMO

The molecular imaging of biomarkers plays an increasing role in medical diagnostics. In particular, the imaging of enzyme activity is a promising approach, as it enables the use of its inherent catalytic activity for the amplification of an imaging signal. The increased activity of a sulfatase enzyme has been observed in several types of cancers. We describe the development and in vitro evaluation of molecular imaging agents that allow for the detection of sulfatase activity using the whole-body, non-invasive MRI and CEST imaging methods. This approach relies on a responsive ligand that features a sulfate ester moiety, which upon sulfatase-catalyzed hydrolysis undergoes an elimination process that changes the functional group, coordinating with the metal ion. When Gd3+ is used as the metal, the complex can be used for MRI, showing a 25% decrease at 0.23T and a 42% decrease at 4.7T in magnetic relaxivity after enzymatic conversion, thus providing a "switch-off" contrast agent. Conversely, the use of Yb3+ as the metal leads to a "switch-on" effect in the CEST imaging of sulfatase activity. Altogether, the results presented here provide a molecular basis and a proof-of-principle for the magnetic imaging of the activity of a key cancer biomarker.

7.
EJNMMI Res ; 13(1): 77, 2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37644167

RESUMO

BACKGROUND: Early detection of recurrent or progressive HCC remains the strongest prognostic factor for survival. Dual tracer PET/CT imaging with [11C]CH and [18F]FDG can further increase detection rates as both tracers entail different metabolic pathways involved in HCC development. We investigated dual-tracer PET/CT in clinical decision making in patients suspected of recurrent or progressive HCC. All HCC patients who underwent both [11C]CH and [18F]FDG PET/CT in our institute from February 2018 to December 2021 were included. Both tracer PET/CT were within 4 weeks of each other with at least 6-month follow-up. Patients underwent dual tracer PET/CT because of unexplained and suspicious CT/MRI or sudden rise of serum tumour markers. A detected lesion was considered critical when the finding had prognostic consequences leading to treatment changes. RESULTS: Nineteen patients who underwent [11C]CH and [18F]FDG PET/CT were included of which all but six patients were previously treated for HCC. Dual-tracer critical finding detection rate was 95%, with [18F]FDG 68%, and [11C]CH 84%. Intrahepatic HCC recurrence finding rate was 65% for both tracers. [18F]FDG found more ablation site recurrences (4/5) compared to [11C]CH (2/5). Only [11C]CH found two needle tract metastases. Both tracers found 75% of the positive lymph nodes. Two new primary tumours were found, one by [18F]FDG and both by [11C]CH. CONCLUSIONS: Our study favours a dual-tracer approach in HCC staging in high-risk patients or when conventional imaging is non-conclusive.

8.
Clin Transl Radiat Oncol ; 42: 100652, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37415639

RESUMO

Background and purpose: Previous pre-clinical research using [18F]FDG-PET has shown that whole-brain photon-based radiotherapy can affect brain glucose metabolism. This study, aimed to investigate how these findings translate into regional changes in brain [18F]FDG uptake in patients with head and neck cancer treated with intensity-modulated proton therapy (IMPT). Materials and methods: Twenty-three head and neck cancer patients treated with IMPT and available [18F]FDG scans before and at 3 months follow-up were retrospectively evaluated. Regional assessment of the [18F]FDG standardized uptake value (SUV) parameters and radiation dose in the left (L) and right (R) hippocampi, L and R occipital lobes, cerebellum, temporal lobe, L and R parietal lobes and frontal lobe were evaluated to understand the relationship between regional changes in SUV metrics and radiation dose. Results: Three months after IMPT, [18F]FDG brain uptake calculated using SUVmean and SUVmax, was significantly higher than that before IMPT. The absolute SUVmean after IMPT was significantly higher than before IMPT in seven regions of the brain (p ≤ 0.01), except for the R (p = 0.11) and L (p = 0.15) hippocampi. Absolute and relative changes were variably correlated with the regional maximum and mean doses received in most of the brain regions. Conclusion: Our findings suggest that 3 months after completion of IMPT for head and neck cancer, significant increases in the uptake of [18F]FDG (reflected by SUVmean and SUVmax) can be detected in several individual key brain regions, and when evaluated jointly, it shows a negative correlation with the mean dose. Future studies are needed to assess whether and how these results could be used for the early identification of patients at risk for adverse cognitive effects of radiation doses in non-tumor tissues.

9.
J Clin Med ; 12(10)2023 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-37240550

RESUMO

The aim of this study was to evaluate whether radiologically defined sarcopenia, or a low skeletal muscle index (SMI), could be used as a practical biomarker for frailty and postoperative complications (POC) in patients with head and neck skin cancer (HNSC). This was a retrospective study on prospectively collected data. The L3 SMI (cm2/m2) was calculated with use of baseline CT or MRI neck scans and low SMIs were defined using sex-specific cut-off values. A geriatric assessment with a broad range of validated tools was performed at baseline. POC was graded with the Clavien-Dindo Classification (with a grade of > II as the cut-off). Univariate and multivariable regression analyses were performed with low SMIs and POC as the endpoints. The patients' (n = 57) mean age was 77.0 ± 9 years, 68.4% were male, and 50.9% had stage III-IV cancer. Frailty was determined according to Geriatric 8 (G8) score (OR 7.68, 95% CI 1.19-49.66, p = 0.032) and the risk of malnutrition was determined according to the Malnutrition Universal Screening Tool (OR 9.55, 95% CI 1.19-76.94, p = 0.034), and these were independently related to low SMIs. Frailty based on G8 score (OR 5.42, 95% CI 1.25-23.49, p = 0.024) was the only variable related to POC. However, POC was more prevalent in patients with low SMIs (∆ 19%, OR 1.8, 95% CI 0.5-6.0, p = 0.356).To conclude, a low SMI is a practical biomarker for frailty and malnutrition in HNSC. Future research should be focused on interventions based on low SMI scores and assess the effect of the intervention on SMI, frailty, malnutrition, and POC.

10.
Eur J Nucl Med Mol Imaging ; 50(9): 2736-2750, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37039901

RESUMO

PURPOSE: Patient-tailored management of thyroid nodules requires improved risk of malignancy stratification by accurate preoperative nodule assessment, aiming to personalize decisions concerning diagnostics and treatment. Here, we perform an exploratory pilot study to identify possible patterns on multispectral optoacoustic tomography (MSOT) for thyroid malignancy stratification. For the first time, we directly correlate MSOT images with histopathology data on a detailed level. METHODS: We use recently enhanced data processing and image reconstruction methods for MSOT to provide next-level image quality by means of improved spatial resolution and spectral contrast. We examine optoacoustic features in thyroid nodules associated with vascular patterns and correlate these directly with reference histopathology. RESULTS: Our methods show the ability to resolve blood vessels with diameters of 250 µm at depths of up to 2 cm. The vessel diameters derived on MSOT showed an excellent correlation (R2-score of 0.9426) with the vessel diameters on histopathology. Subsequently, we identify features of malignancy observable in MSOT, such as intranodular microvascularity and extrathyroidal extension verified by histopathology. Despite these promising features in selected patients, we could not determine statistically relevant differences between benign and malignant thyroid nodules based on mean oxygen saturation in thyroid nodules. Thus, we illustrate general imaging artifacts of the whole field of optoacoustic imaging that reduce image fidelity and distort spectral contrast, which impedes quantification of chromophore presence based on mean concentrations. CONCLUSION: We recommend examining optoacoustic features in addition to chromophore quantification to rank malignancy risk. We present optoacoustic images of thyroid nodules with the highest spatial resolution and spectral contrast to date, directly correlated to histopathology, pushing the clinical translation of MSOT.


Assuntos
Técnicas Fotoacústicas , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Projetos Piloto , Técnicas Fotoacústicas/métodos , Tomografia/métodos , Tomografia Computadorizada por Raios X
11.
Eur J Nucl Med Mol Imaging ; 50(8): 2258-2270, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36947185

RESUMO

PURPOSE: Monoclonal antibody (mAb)-based PET (immunoPET) imaging can characterise tumour lesions non-invasively. It may be a valuable tool to determine which patients may benefit from treatment with a specific monoclonal antibody (mAb) and evaluate treatment response. For 89Zr immunoPET imaging, higher sensitivity of state-of-the art PET/CT systems equipped with silicon photomultiplier (SiPM)-based detector elements may be beneficial as the low positron abundance of 89Zr causes a low signal-to-noise level. Moreover, the long physical half-life limits the amount of activity that can be administered to the patients leading to poor image quality even when using long scan durations. Here, we investigated the difference in semiquantitative performance between the PMT-based Biograph mCT, our clinical reference system, and the SiPM-based Biograph Vision PET/CT in 89Zr immunoPET imaging. Furthermore, the effects of scan duration reduction using the Vision on semiquantitative imaging parameters and its influence on image quality assessment were evaluated. METHODS: Data were acquired on day 4 post 37 MBq 89Zr-labelled mAb injection. Five patients underwent a double scan protocol on both systems. Ten patients were scanned only on the Vision. For PET image reconstruction, three protocols were used, i.e. one camera-dependent protocol and European Association of Nuclear Medicine Research Limited (EARL) standards 1 and 2 compliant protocols. Vision data were acquired in listmode and were reprocessed to obtain images at shorter scan durations. Semiquantitative PET image parameters were derived from tumour lesions and healthy tissues to assess differences between systems and scan durations. Differently reconstructed images obtained using the Vision were visually scored regarding image quality by two nuclear medicine physicians. RESULTS: When images were reconstructed using 100% acquisition time on both systems following EARL standard 1 compliant reconstruction protocols, results regarding semiquantification were comparable. For Vision data, reconstructed images that conform to EARL1 standards still resulted in comparable semiquantification at shorter scan durations (75% and 50%) regarding 100% acquisition time. CONCLUSION: Scan duration of 89Zr immunoPET imaging using the Vision can be decreased up to 50% compared with using the mCT while maintaining image quality using the EARL1 compliant reconstruction protocol.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias/diagnóstico por imagem , Padrões de Referência , Anticorpos Monoclonais , Tomografia por Emissão de Pósitrons/métodos , Processamento de Imagem Assistida por Computador
12.
Eur J Nucl Med Mol Imaging ; 50(6): 1735-1742, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36781423

RESUMO

PURPOSE: Radiologically defined sarcopenia, or a low skeletal muscle index (SMI), is an emerging biomarker for adverse clinical outcomes in head and neck cancer (HNC) patients. Recently, SMI measurements have been validated at the level of the third cervical vertebra (C3) on diagnostic neck CT scans but are not yet validated on low-dose (LD) neck CT scans from the [18F]-FDG PET-CT. This hampers SMI analysis in HNC patients without a diagnostic neck CT but with a [18F]-FDG PET-CT scan. Therefore, the aim was to study whether (low) SMI based on LD CT scan from [18F]-FDG PET-CT is comparable to those derived from diagnostic neck CT scans. METHODS: HNC patients with both diagnostic CT and [18F]-FDG PET-CT of the neck were prospectively included into the OncoLifeS data-biobank. Skeletal muscle was retrospectively delineated at the level of the third cervical vertebra (C3), and (low) SMI (cm2/m2) was calculated for diagnostic and LD neck CTs. (Low) SMI from the diagnostic neck CT was considered the reference standard. Intra-class correlation coefficient (ICC), Bland-Altman plots, and Cohen's Kappa analysis were performed. RESULTS: The cohort (n = 233) mean age was 66.2 ± 12.8 years, and 74.2% of patients were male. Inter-rater reliability was excellent (ICC > 0.990, 95% confidence interval 0.975-0.996, p < 0.001). The agreement of SMI between both modalities was high according to the Bland-Altman plot (mean ΔSMI = - 0.19 cm2/m2), and there was no substantial bias. Cohen's Kappa analysis showed an almost perfect agreement of low SMI between the two modalities (κ = 0.911, p < 0.001). The position of arms didn't affect the high agreement of (low) SMI. CONCLUSION: Skeletal muscle mass, as measured with (low) SMI, remains constant irrespective of CT acquisition parameters (diagnostic neck CT scans versus LD neck scans of the [18F]-FDG PET-CT scan), positioning of arms, and observers. These findings contribute to the construction of a clinically useful radiological biomarker for SMI and therefore identify patients at risk for adverse clinical outcomes.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fluordesoxiglucose F18 , Estudos Retrospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Músculo Esquelético/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem
13.
Cancer Imaging ; 22(1): 69, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36527149

RESUMO

This review describes the main benefits of using long axial field of view (LAFOV) PET in clinical applications. As LAFOV PET is the latest development in PET instrumentation, many studies are ongoing that explore the potentials of these systems, which are characterized by ultra-high sensitivity. This review not only provides an overview of the published clinical applications using LAFOV PET so far, but also provides insight in clinical applications that are currently under investigation. Apart from the straightforward reduction in acquisition times or administered amount of radiotracer, LAFOV PET also allows for other clinical applications that to date were mostly limited to research, e.g., dual tracer imaging, whole body dynamic PET imaging, omission of CT in serial PET acquisition for repeat imaging, and studying molecular interactions between organ systems. It is expected that this generation of PET systems will significantly advance the field of nuclear medicine and molecular imaging.


Assuntos
Elétrons , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos
14.
EJNMMI Phys ; 9(1): 74, 2022 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-36308568

RESUMO

BACKGROUND: Excellent performance characteristics of the Vision Quadra PET/CT, e.g. a substantial increase in sensitivity, allow for precise measurements of image-derived input functions (IDIF) and tissue time activity curves. Previously we have proposed a method for a reduced 30 min (as opposed to 60 min) whole body 18F-FDG Patlak PET imaging procedure using a previously published population-averaged input function (PIF) scaled to IDIF values at 30-60 min post-injection (p.i.). The aim of the present study was to apply this method using the Vision Quadra PET/CT, including the use of a PIF to allow for shortened scan durations. METHODS: Twelve patients with suspected lung malignancy were included and received a weight-based injection of 18F-FDG. Patients underwent a 65-min dynamic PET acquisition which were reconstructed using European Association of Nuclear Medicine Research Ltd. (EARL) standards 2 reconstruction settings. A volume of interest (VOI) was placed in the ascending aorta (AA) to obtain the IDIF. An external PIF was scaled to IDIF values at 30-60, 40-60, and 50-60 min p.i., respectively, and parametric 18F-FDG influx rate constant (Ki) images were generated using a t* of 30, 40 or 50 min, respectively. Herein, tumour lesions as well as healthy tissues, i.e. liver, muscle tissue, spleen and grey matter, were segmented. RESULTS: Good agreement between the IDIF and corresponding PIF scaled to 30-60 min p.i. and 40-60 min p.i. was obtained with 7.38% deviation in Ki. Bland-Altman plots showed excellent agreement in Ki obtained using the PIF scaled to the IDIF at 30-60 min p.i. and at 40-60 min p.i. as all data points were within the limits of agreement (LOA) (- 0.004-0.002, bias: - 0.001); for the 50-60 min p.i. Ki, all except one data point fell in between the LOA (- 0.021-0.012, bias: - 0.005). CONCLUSIONS: Parametric whole body 18F-FDG Patlak Ki images can be generated non-invasively on a Vision Quadra PET/CT system. In addition, using a scaled PIF allows for a substantial (factor 2 to 3) reduction in scan time without substantial loss of accuracy (7.38% bias) and precision (image quality and noise interference).

15.
J Clin Med ; 11(16)2022 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-36012884

RESUMO

A low skeletal muscle index (SMI), defined with cut-off values, is a promising predictor for adverse events (AEs) in head and neck squamous cell cancer (HNSCC) patients. The aim was to generate sex-specific SMI cut-off values based on AE to diagnose low SMI and to analyse the relationship between low SMI and AEs in HNSCC patients. In this present study, HNSCC patients were prospectively included in a large oncological data-biobank and SMI was retrospectively measured using baseline neck scans. In total, 193 patients were included and were stratified according to treatment modality: (chemo-)radiotherapy ((C)RT) (n = 135) and surgery (n = 61). AE endpoints were based on the occurrence of clinically relevant toxicities (Common Terminology Criteria for Adverse Events grade ≥ III) and postoperative complications (Clavien-Dindo Classification grade ≥ II). Sex-specific SMI cut-off values were generated with receiver operating characteristic curves, based on the AE endpoints. The relationship of the baseline characteristics and AEs was analysed with logistic regression analysis, with AEs as the endpoint. Multivariable logistic analysis showed that low SMI (OR 3.33, 95%CI 1.41-7.85) and tumour stage (OR 3.45, 95%CI 1.28-9.29) were significantly and independently associated to (C)RT toxicity. Low SMI was not related to postoperative complications. To conclude, sex-specific SMI cut-off values, were generated based on the occurrence of AEs. Low SMI and tumour stage were independently related to (C)RT toxicity in HNSCC patients.

16.
PLoS One ; 17(8): e0272643, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36006959

RESUMO

INTRODUCTION: One major challenge in PET radiomics is its sensitivity to noise. Low signal-to-noise ratio (SNR) affects not only the precision but also the accuracy of quantitative metrics extracted from the images resulting in noise-induced bias. This phantom study aims to identify the radiomic features that are robust to noise in terms of precision and accuracy and to explore some methods that might help to correct noise-induced bias. METHODS: A phantom containing three 18F-FDG filled 3D printed inserts, reflecting heterogeneous tracer uptake and realistic tumor shapes, was used in the study. The three different phantom inserts were filled and scanned with three different tumor-to-background ratios, simulating a total of nine different tumors. From the 40-minute list-mode data, ten frames each for 5 s, 10 s, 30 s, and 120 s frame duration were reconstructed to generate images with different noise levels. Under these noise conditions, the precision and accuracy of the radiomic features were analyzed using intraclass correlation coefficient (ICC) and similarity distance metric (SDM) respectively. Based on the ICC and SDM values, the radiomic features were categorized into four groups: poor, moderate, good, and excellent precision and accuracy. A "difference image" created by subtracting two statistically equivalent replicate images was used to develop a model to correct the noise-induced bias. Several regression methods (e.g., linear, exponential, sigmoid, and power-law) were tested. The best fitting model was chosen based on Akaike information criteria. RESULTS: Several radiomic features derived from low SNR images have high repeatability, with 68% of radiomic features having ICC ≥ 0.9 for images with a frame duration of 5 s. However, most features show a systematic bias that correlates with the increase in noise level. Out of 143 features with noise-induced bias, the SDM values were improved based on a regression model (53 features to excellent and 67 to good) indicating that the noise-induced bias of these features can be, at least partially, corrected. CONCLUSION: To have a predictive value, radiomic features should reflect tumor characteristics and be minimally affected by noise. The present study has shown that it is possible to correct for noise-induced bias, at least in a subset of the features, using a regression model based on the local image noise estimates.


Assuntos
Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador , Viés , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons
17.
Eur J Nucl Med Mol Imaging ; 49(13): 4652-4660, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35876867

RESUMO

PURPOSE: Current European Association of Nuclear Medicine (EANM) Research Ltd. (EARL) guidelines for the standardisation of PET imaging developed for conventional systems have not yet been adjusted for long axial field-of-view (LAFOV) systems. In order to use the LAFOV Siemens Biograph Vision Quadra PET/CT (Siemens Healthineers, Knoxville, TN, USA) in multicentre research and harmonised clinical use, compliance to EARL specifications for 18F-FDG tumour imaging was explored in the current study. Additional tests at various locations throughout the LAFOV and the use of shorter scan durations were included. Furthermore, clinical data were collected to further explore and validate the effects of reducing scan duration on semi-quantitative PET image biomarker accuracy and precision when using EARL-compliant reconstruction settings. METHODS: EARL compliance phantom measurements were performed using the NEMA image quality phantom both in the centre and at various locations throughout the LAFOV. PET data (maximum ring difference (MRD) = 85) were reconstructed using various reconstruction parameters and reprocessed to obtain images at shorter scan durations. Maximum, mean and peak activity concentration recovery coefficients (RC) were obtained for each sphere and compared to EARL standards specifications. Additionally, PET data (MRD = 85) of 10 oncological patients were acquired and reconstructed using various reconstruction settings and reprocessed from 10 min listmode acquisition into shorter scan durations. Per dataset, SUVs were derived from tumour lesions and healthy tissues. ANOVA repeated measures were performed to explore differences in lesion SUVmax and SUVpeak. Wilcoxon signed-rank tests were performed to evaluate differences in background SUVpeak and SUVmean between scan durations. The coefficient of variation (COV) was calculated to characterise noise. RESULTS: Phantom measurements showed EARL compliance for all positions throughout the LAFOV for all scan durations. Regarding patient data, EARL-compliant images showed no clinically meaningful significant differences in lesion SUVmax and SUVpeak or background SUVmean and SUVpeak between scan durations. Here, COV only varied slightly. CONCLUSION: Images obtained using the Vision Quadra PET/CT comply with EARL specifications. Scan duration and/or activity administration can be reduced up to a factor tenfold without the interference of increased noise.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Imagens de Fantasmas , Biomarcadores
18.
Mol Pharm ; 19(8): 2992-3001, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35849844

RESUMO

Adenosine A2A and dopamine D2 receptors in the basal ganglia form heterotetrameric structures that are involved in the regulation of motor activity and neuropsychiatric functions. The present study examines the A2A receptor-mediated modulation of D2 receptor binding in vivo using positron emission tomography (PET) with the D2 antagonist tracer [11C]raclopride. Healthy male Wistar rats (n = 8) were scanned (60 min dynamic scan) with [11C]raclopride at baseline and 7 days later following an acute administration of the A2A agonist CGS21680 (1 mg/kg), using a MicroPET Focus-220 camera. Nondisplaceable binding potential (BPND) values were calculated using a simplified reference tissue model (SRTM), with cerebellum as the reference tissue. SRTM analysis did not show any significant changes in [11C]raclopride BPND (p = 0.102) in striatum after CGS21680 administration compared to the baseline. As CGS21680 strongly affects hemodynamics, we also used arterial blood sampling and a metabolite-corrected plasma input function for compartment modeling using the reversible two-tissue compartment model (2TCM) to obtain the BPND from the k3/k4 ratio and from the striatum/cerebellum volume of distribution ratio (DVR) in a second group of animals. These rats underwent dynamic [11C]raclopride scans after pretreatment with a vehicle (n = 5), a single dose of CGS21680 (1 mg/kg, n = 5), or a single dose of the A2A antagonist KW6002 (1 mg/kg, n = 5). The parent fraction in plasma was significantly higher in the CGS21680-treated group (p = 0.0001) compared to the vehicle-treated group. GCS21680 administration significantly reduced the striatal k3/k4 ratio (p < 0.01), but k3 and k4 estimates may be less reliable. The BPND (DVR-1) decreased from 1.963 ± 0.27 in the vehicle-treated group to 1.53 ± 0.55 (p = 0.080) or 1.961 ± 0.11 (p = 0.993) after the administration of CGS21680 or KW6002, respectively. Our study suggests that the A2A agonist CGS21680, but not the antagonist KW6002, may reduce the D2 receptor availability in the striatum.


Assuntos
Dopamina , Receptor A2A de Adenosina , Adenosina/metabolismo , Agonistas do Receptor A2 de Adenosina , Antagonistas do Receptor A2 de Adenosina , Animais , Radioisótopos de Carbono , Corpo Estriado/metabolismo , Ligantes , Masculino , Tomografia por Emissão de Pósitrons/métodos , Racloprida , Ratos , Ratos Wistar , Receptor A2A de Adenosina/metabolismo , Receptores Dopaminérgicos/metabolismo , Roedores/metabolismo
20.
Eur Radiol ; 32(9): 6526-6535, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35420303

RESUMO

OBJECTIVES: To determine the value of a deep learning masked (DLM) auto-fixed volume of interest (VOI) segmentation method as an alternative to manual segmentation for radiomics-based diagnosis of clinically significant (CS) prostate cancer (PCa) on biparametric magnetic resonance imaging (bpMRI). MATERIALS AND METHODS: This study included a retrospective multi-center dataset of 524 PCa lesions (of which 204 are CS PCa) on bpMRI. All lesions were both semi-automatically segmented with a DLM auto-fixed VOI method (averaging < 10 s per lesion) and manually segmented by an expert uroradiologist (averaging 5 min per lesion). The DLM auto-fixed VOI method uses a spherical VOI (with its center at the location of the lowest apparent diffusion coefficient of the prostate lesion as indicated with a single mouse click) from which non-prostate voxels are removed using a deep learning-based prostate segmentation algorithm. Thirteen different DLM auto-fixed VOI diameters (ranging from 6 to 30 mm) were explored. Extracted radiomics data were split into training and test sets (4:1 ratio). Performance was assessed with receiver operating characteristic (ROC) analysis. RESULTS: In the test set, the area under the ROC curve (AUCs) of the DLM auto-fixed VOI method with a VOI diameter of 18 mm (0.76 [95% CI: 0.66-0.85]) was significantly higher (p = 0.0198) than that of the manual segmentation method (0.62 [95% CI: 0.52-0.73]). CONCLUSIONS: A DLM auto-fixed VOI segmentation can provide a potentially more accurate radiomics diagnosis of CS PCa than expert manual segmentation while also reducing expert time investment by more than 97%. KEY POINTS: • Compared to traditional expert-based segmentation, a deep learning mask (DLM) auto-fixed VOI placement is more accurate at detecting CS PCa. • Compared to traditional expert-based segmentation, a DLM auto-fixed VOI placement is faster and can result in a 97% time reduction. • Applying deep learning to an auto-fixed VOI radiomics approach can be valuable.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA