Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Indian J Anaesth ; 65(4): 289-294, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34103742

RESUMO

BACKGROUND AND AIMS: Ultrasonography (USG) is used to evaluate gastric residual volume (GRV); however, this technique may have inter-assessor variability. This study aimed to measure GRV in three groups of fasted patients 2 h after they received 200 mL of water, clear apple juice or apple-flavoured oral rehydration solution (ORS) and to determine inter-assessor reliability of USG-guided GRV measurement. METHODS: We randomised 90 adult patients planned for elective cancer surgery, with no risk factors for delayed gastric emptying, to receive 200 mL of water, clear apple juice or apple-flavoured ORS after overnight fasting. Two hours later, two blinded assessors (a trained anaesthesiologist and a radiologist) independently determined USG-guided GRV. The primary outcome was GRV measured by the radiologist. The secondary outcome was inter-assessor correlation and agreement in GRV measurements. RESULTS: There was no statistically significant difference in median GRV between groups (apple-flavoured ORS 74.8 mL, apple juice 63.7 mL, and water 62.1 mL, P = 0.11). We found poor correlation between measurements of radiologist and anaesthesiologist (Intra-class correlation coefficient 0.3, 95% confidence intervals 0.09 to 0.48, P value 0.002). The average (mean) bias was 5.4 mL (standard deviation 42.3 mL) and the 95% limits of agreement were -79.2 ml to +90 ml. CONCLUSION: Patients receiving 200 mL of water, clear apple juice or apple-flavoured ORS had comparable GRV after 2 h. There was poor correlation and agreement between GRV measurements of different assessors, indicating that more training may be required for anaesthesiologists to attain proficiency in the quantitative assessment of GRV.

2.
Indian J Anaesth ; 60(12): 899-905, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28003691

RESUMO

The various physiological changes in pregnancy make the parturient vulnerable for early and rapid desaturation. Severe hypoxaemia during intubation can potentially compromise two lives (mother and foetus). Thus tracheal intubation in the pregnant patient poses unique challenges, and necessitates meticulous planning, ready availability of equipment and expertise to ensure maternal and foetal safety. The All India Difficult Airway Association (AIDAA) proposes a stepwise plan for the safe management of the airway in obstetric patients. These guidelines have been developed based on available evidence; wherever robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists (ISA). Modified rapid sequence induction using gentle intermittent positive pressure ventilation with pressure limited to ≤20 cm H2O is acceptable. Partial or complete release of cricoid pressure is recommended when face mask ventilation, placement of supraglottic airway device (SAD) or tracheal intubation prove difficult. One should call for early expert assistance. Maternal SpO2 should be maintained ≥95%. Apnoeic oxygenation with nasal insufflation of 15 L/min oxygen during apnoea should be performed in all patients. If tracheal intubation fails, a second- generation SAD should be inserted. The decision to continue anaesthesia and surgery via the SAD, or perform fibreoptic-guided intubation via the SAD or wake up the patient depends on the urgency of surgery, foeto-maternal status and availability of resources and expertise. Emergency cricothyroidotomy must be performed if complete ventilation failure occurs.

3.
Korean J Anesthesiol ; 69(3): 234-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27274367

RESUMO

BACKGROUND: Fentanyl-induced cough (FIC) is a transient condition with a reported incidence of 18% to 65% depending on the dose and route of administration of fentanyl. Nonpharmacological methods to prevent FIC are more cost-effective than medications. Dilution of fentanyl has a proven role in the prevention of FIC. Acupressure can also prevent FIC because it has a proven role in the treatment of cough. METHODS: This study included 225 female patients with an American Society of Anesthesiologists physical status of I or II who were randomly divided into 3 groups of 75 patients each. Patients in the control group received undiluted fentanyl at 3 µg/kg, patients in the acupressure group received undiluted fentanyl at 3 µg/kg with acupressure, and patients in the dilution group received diluted fentanyl at 3 µg/kg. Coughing was noted within 2 min of fentanyl administration. The severity of FIC was graded as mild (1-2 coughs), moderate (3-4 coughs), or severe (≥5 coughs). The timing of coughs was also noted. RESULTS: The incidence of FIC was 12.7% in the control group, 6.8% in the dilution group, and 1.3% in the acupressure group. The difference in the incidence of cough was statistically significant (P = 0.008) between the control and acupressure groups. The difference in the severity of cough among the groups was not statistically significant. The median onset time of cough among all groups was 9 to 12 seconds. CONCLUSIONS: The application of acupressure prior to administration of fentanyl significantly reduces the incidence of FIC. Dilution of fentanyl also reduces the incidence of FIC, but the difference is not statistically significant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA