Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Dental press j. orthod. (Impr.) ; 29(2): e2423212, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557692

RESUMO

ABSTRACT Objective: The purpose of this retrospective study was to compare accuracy of arch expansion using two different thermoplastic materials in Invisalign aligners: EX30® (Polyethylene Terephthalate Glycol, or PETG) and SmartTrack® (polyurethane). Methods: The study sample comprised 65 adult patients consecutively treated with Invisalign from two private practices: group 1 - treated with EX30® (358 teeth) and group 2 - treated with SmartTrack® (888 teeth). Six hundred and twenty-three measurements were assessed in three digital models throughout treatment: model 1 - initial, model 2 - predicted tooth position, and model 3 - achieved position. Sixteen reference points per arch were marked and, after best alignment, 2 points per tooth were copied from one digital model to another. Linear values of both arches were measured for canines, premolars, and first molars: on lingual gingival margins and cusp tips of every tooth. Comparisons were performed by Wilcoxon and Mann-Whitney test. Results: Both termoplastic materials presented significant differences between predicted and achieved values for all measurements, except for the lower molar cusp tip in the SmartTrack® group. There is no statistical difference in the accuracy of transverse expansion between these two materials. Overall accuracy for EX30® aligners in maxilla and mandible were found to be 37 and 38%, respectively; and Smarttrack® presented an overall accuracy of 56.62% in the maxilla and 68.72% in the mandible. Conclusions: It is not possible to affirm one material expands better than the other. Further controlled clinical studies should be conducted comparing SmartTrack® and EX30® under similar conditions.


RESUMO Objetivo: O objetivo deste estudo retrospectivo foi comparar a acurácia na expansão da arcada utilizando alinhadores Invisalign com dois tipos de material termoplástico: EX30® (Polietileno Tereftalato Glicol, ou PETG) e SmartTrack® (poliuretano). Método: A amostra desse estudo incluiu 65 pacientes adultos tratados consecutivamente em dois consultórios particulares: grupo 1 - tratado com EX30® (358 dentes), e grupo 2 - tratado com SmartTrack® (888 dentes). Foram avaliadas 623 medidas em três pares de modelos digitais, ao longo do tratamento: modelo 1 - inicial, modelo 2 - posição dentária planejada, modelo 3 - posição alcançada. Foram marcados 16 pontos de referência por arcada e, após o bestfit, 2 pontos por arcada foram copiados de um modelo digital para o outro. Medidas lineares de ambas as arcadas foram aferidas para caninos, pré-molares e primeiros molares, localizadas na margem gengival lingual e ponta de cúspide de todos os dentes. Foram realizadas comparações usando os testes Wilcoxon e Mann-Whitney. Resultados: Ambos os materiais termoplásticos apresentaram diferenças significativas entre os valores planejados e alcançados em todas as medidas, exceto na ponta de cúspide dos primeiros molares inferiores do grupo SmartTrack®. Não houve diferença estatística entre esses dois materiais quanto à acurácia da expansão transversa. Em termos gerais, a acurácia dos alinhadores EX30® na maxila e mandíbula foi de 37% e 38%, respectivamente. O grupo SmartTrack® apresentou acurácia de 56,62% e 68,72% na maxila e mandíbula, respectivamente. Conclusões: Não foi possível afirmar que um material expande melhor que o outro. Estudos clínicos controlados futuros devem ser conduzidos comparando SmartTrack® e EX30® sob condições similares.

2.
Dental press j. orthod. (Impr.) ; 29(2): e2423237, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557693

RESUMO

ABSTRACT Objective: This retrospective study aimed to assess the predictability of Invisalign® aligners regarding rotational, mesio-distal and buccal-lingual tip movements. Methods: Two materials were included in the analysis - EX30, used until 2013; and SmartTrack, in current use. The study comprised 56 adult patients treated with Invisalign Comprehensive. Data sample were assessed on three sets of digital models; model 1 - initial, model 2 - predicted, and model 3 - achieved. Sixty reference points were marked in each dental arch, and two reference planes assisted the superimposition. The degree of rotation, mesio-distal and buccal-lingual tip was obtained via trigonometric calculations, through a previously published validated method. The accuracy of outcomes was compared according to the types of tooth movement and teeth groups,and the influence of predetermined variables on movement accuracy was also investigated. Results: Rotation and mesio-distal tip did not present any significant difference when comparing EX30 and SmartTrack groups. Only buccal-lingual tip presented a significant difference, incisor and canine groups treated with EX30 aligners presented an increase in accuracy (p= 0.007 and p = 0.007, respectively). For each additional degree planned for rotation movements, there was an increase of 0.35° in the discrepancy, and an increase of 0.40° and 0.41° for mesio-distal and buccal-lingual tip, respectively. EX30 and SmartTrack discrepancies were compared by multilevel linear regression. Conclusion: EX30 aligners reached higher accuracy for buccal-lingual tip in anterior teeth. However, for rotation and mesio-distal tip, SmartTrack and EX30 are similarly accurate. The total amount of planned movement has a significant impact on accuracy rates, with a decrease in accuracy for every additional degree.


RESUMO Objetivo: Esse estudo retrospectivo teve como objetivo aferir a previsibilidade dos alinhadores Invisalign em relação aos movimentos de rotação e inclinações mesiodistal e vestibulolingual. Material e Métodos: Foram incluídos dois materiais nessa análise: EX30®, utilizado até 2013; e SmartTrack®, atualmente em uso. Esse estudo avaliou 56 pacientes tratados com Invisalign Comprehensive. Os dados foram avaliados em três pares de modelos digitais; modelo 1 - inicial, modelo 2 - planejado, e modelo 3 - alcançado. Foram marcados 60 pontos de referência em cada arcada, sendo a sobreposição realizada com auxílio de planos de referência. O grau de rotação e inclinações mesiodistal e vestibulolingual foi obtido por cálculos de trigonometria, usando um método validado publicado anteriormente. Os resultados foram comparados de acordo com os tipos de movimento dentário e grupos de dentes, também foi investigada a influência de variáveis predeterminadas na confiabilidade dos movimentos. Resultados: Os movimentos de rotação e inclinação mesiodistal não apresentaram diferença estatística, quando comparados os grupos EX30® e SmartTrack®. Somente a inclinação vestibulolingual apresentou diferença estatisticamente significativa, sendo que os grupos de incisivos e caninos tratados com alinhadores EX30® apresentaram um aumento na previsibilidade(p= 0,007 e p= 0,007, respectivamente). Para cada grau adicional planejado para movimento de rotação, ocorreu um aumento de 0,35° na discrepância, e aumentos de 0,40° e 0,41° para as inclinações mesiodistal e vestibulolingual, respectivamente. As discrepâncias entre EX30® e SmartTrack® foram comparadas por regressão linear multinível. Conclusão: Os alinhadores EX30® alcançaram maior previsibilidade para a inclinação vestibulolingual em dentes anteriores. No entanto, para rotação e inclinação mesiodistal, SmartTrack® e EX30® apresentaram previsibilidade similar. A quantidade total de movimento planejado apresenta influência significativa nas taxas de previsibilidade, com diminuição na acurácia para cada grau adicional.

3.
Dental press j. orthod. (Impr.) ; 26(3): e2119148, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1286208

RESUMO

ABSTRACT Objective: The objectives of the present study were to develop a method for longitudinally measuring tooth rotation, inclination and angulation on digital models, and to test the method validity and reliability. Methods: The initial and final planned models of 14 patients treated with Invisalign® (386 teeth) were exported from ClinCheck®. The rotation, inclination and angulation values were assessed for the incisors, canines, premolars and molars, in both models, using trigonometry. An application was developed in Python 2.7 to automate the measurements. The ∆planned (variation in the position between the initial and final planned models) was obtained for each tooth and each type of movement. To test the validity, the degree of agreement between the ∆planned and the values available in the Invisalign® Table of Movements was assessed using the Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis. For intra and inter-rater reliabilities, the ∆planned was obtained again. Results: Excellent ICCs (> 0.9) and limits of agreement with narrow and clinically acceptable discrepancies were obtained for the rotation of all teeth (except maxillary canines, which had broader limits: -3.47 - 5.43) and for the inclination of premolars and molars. The inclination of anterior teeth and angulation of all teeth had ICCs and limits that were not indicative of great agreement. The reliability was high for the three movements (discrepancy <2°). Conclusions: The method developed is reliable and suitable for longitudinally measuring inclination (posterior teeth) and rotation (except maxillary canines). It has limited value for the other movements measurements.


RESUMO Objetivo: Os objetivos do presente estudo foram desenvolver um método para medir longitudinalmente a rotação, inclinação e angulação dentárias em modelos digitais, e testar sua validade e reprodutibilidade. Material e Métodos: Os modelos inicial e final planejado de 14 pacientes tratados com Invisalign® (386 dentes) foram exportados do ClinCheck®. Os valores de rotação, inclinação e angulação foram calculados para incisivos, caninos, pré-molares e molares, em ambos os modelos, por meio de trigonometria. Um aplicativo desenvolvido em Python 2.7 foi utilizado para automatização das medidas. O ∆planejado (variação na posição entre os modelos inicial e final planejado) foi obtido para os movimentos descritos, nos diferentes grupos de dentes. A validade do método foi verificada pelo grau de concordância entre o ∆planejado e os valores disponíveis na Tabela de Movimentos do Invisalign®, utilizando-se o Coeficiente de Correlação Intraclasse (ICC) e a análise de Bland-Altman. O ∆planejado foi novamente calculado para análise da reprodutibilidade intra e interexaminadores. Resultados: Excelentes ICCs (> 0,9) e limites de concordância com discrepâncias reduzidas e clinicamente aceitáveis foram obtidos para a rotação de todos os dentes (exceto os caninos superiores, que expressaram limites mais amplos: -3,47 - 5,43) e para a inclinação de pré-molares e molares. A inclinação dos dentes anteriores e a angulação de todos os dentes apresentaram ICCs e limites não representativos de boa concordância. A reprodutibilidade foi alta para os três movimentos (discrepância < 2°). Conclusões: O método desenvolvido é reprodutível e se mostrou adequado para mensuração longitudinal da inclinação de dentes posteriores e rotação de todos os dentes, exceto caninos superiores. Apresenta valor limitado para as demais mensurações.


Assuntos
Humanos , Técnicas de Movimentação Dentária , Dente Canino , Dente Pré-Molar , Reprodutibilidade dos Testes , Incisivo
4.
Medicine (Baltimore) ; 99(10): e19005, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32150048

RESUMO

Photobiomodulation therapy (PBMT) with low-power laser is used for pain relief in several clinical conditions, including temporomandibular disorders (TMD). As musculoskeletal pain often produces changes in motor behavior, it is common for patients with TMD to present limited mandibular movements. To the date, there is no consensus about the optimal dosimetric parameters of PMBT for TMD. This randomized, controlled, double-blind clinical trial aims to evaluate pain relief and mandibular mobility in patients with TMD following treatments with 2 laser wavelengths, red (660 nm) and infrared (808 nm) individually and in combination as compared to a placebo treatment. One-hundred participants presenting myalgia and arthralgia, with disk displacement or not, will be selected based on the Research Diagnostic Criteria for Temporomandibular Disorders. All participants will be instructed about the etiology, prognosis, and self-care techniques for pain control on TMD, and followed up for 2 weeks. After this period, those who still present pain score over 4 in a visual analog scale (VAS) will be included in the study. Participants will be randomly assigned to 4 treatment groups: G1 = placebo (SHAM); G2 = PBMT with red laser (660 nm, 0.034 cm, 88 J/cm, 100 mW, 3 J/point); G3 = PBMT with infrared laser (808 nm, 0.034 cm, 88 J/cm, 100 mW, 3 J/point); and G4 = PBMT with red and infrared laser alternated between sessions. The treatment consists of 8 sessions, 2 times a week. The effect of the proposed therapies will be measured by: pain reduction in VAS; pressure pain threshold on TMJ, masseter and temporal muscles; and the amplitude of mandibular movements (opening, protrusion, and right and left lateral movements). The data will be collected at the following times: initial (T1), after the 1st treatment session (T2), at the end of treatment (T3), and 30 days after the last PBMT session (T4). For statistical analysis will be used 2-way repeated measures analysis of variance test, complemented by a post hoc Tukey test (P < .05).


Assuntos
Ensaios Clínicos Controlados Aleatórios como Assunto , Transtornos da Articulação Temporomandibular/radioterapia , Método Duplo-Cego , Humanos , Terapia com Luz de Baixa Intensidade , Medição da Dor , Educação de Pacientes como Assunto , Projetos de Pesquisa
5.
Braz. dent. j ; 30(4): 410-416, July-Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011567

RESUMO

Abstract The present study aimed to analyze the effect of LED phototherapy on the presence of hyalinization and root resorption during orthodontic tooth movement (OTM) in rats and to measure the amount of tooth movement. Eighty rats were allocated into two groups: LED and control (CON), where the LED rats were irradiated with infrared LED (850 nm, 30 mW) for 5 min during the first five days of OTM and where controls were not irradiated. Both groups were subdivided into four subgroups (n=10) according to the date of euthanasia (4, 7, 14 and 21 days). Five out of ten LED21 and five of ten CON21 rats were submitted to micro-computed tomography (μCT); μCT scans were taken on days 0, 7, 14 and 21. For histological study, maxillae were processed to light microscopy using Hematoxylin-Eosin (HE) and Tartrate-Resistant Acid Phosphatase (TRAP) histochemistry. The amount of tooth movement did not differ between LED and CON. Hyalinization was observed at the pressure areas in both groups, and it did not show a statistically significant difference between the groups. Root resorption was also observed in both groups after 7 days and it did not represent any differences between the two groups. LED phototherapy was not able to increase the amount of OTM. Similar characteristics of hyalinization and root resorption were observed in both groups.


Resumo O presente estudo tem como objetivo analisar o efeito da fototerapia LED na presença da hialinização e reabsorção radicular durante o movimento dentário ortodôntico (MDO) em ratos, e a mensuração da quantidade de movimento dentário. Oitenta ratos foram alocados em dois grupos: LED e Controle (CON), os ratos foram irradiados com um LED infravermelho (850nm, 30mW) por 5 minutos durante os cinco primeiros dias da MDO; e o grupo controle não foi irradiado. Ambos os grupos foram subdivididos em 4 subgrupos (n=10) de acordo com a data da eutanásia (4, 7, 14 e 21 dias). Cinco dos dez ratos LED21 e cinco dos dez ratos CON21foram submetidos a microtomografia computadorizada (μCT); As μCT foram realizadas nos dias 0, 7, 14 e 21. Para o estudo histológico, as maxilas foram processadas para microscopia de luz, usando hematoxilina-eosina (HE) e Fosfatase ácido Tartrate-Resistente (TRAP) para histoquímica. A quantidade de movimento dentário não diferiu entre o LED e o CON. A hialinização foi observada nas áreas de pressão em ambos os grupos e não mostrou diferença estatisticamente significante. Reabsorção radicular também foi observada em ambos os grupos depois de 7 dias e não houve diferença entre os grupos. A fototerapia LED não aumentou a quantidade de MDO. Características similares de hialinização e reabsorção radicular foram observadas em ambos os grupos


Assuntos
Animais , Ratos , Reabsorção da Raiz , Técnicas de Movimentação Dentária , Ratos Wistar , Microtomografia por Raio-X , Fosfatase Ácida Resistente a Tartarato
6.
J Oral Maxillofac Surg ; 74(4): 786-93, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26706489

RESUMO

This report describes an atypical case of spontaneous mandibular regeneration of a large size bony defect after resection of an aseptic osteonecrotic area near the symphysis and parasymphyseal area. The patient underwent orthodontic therapy, vertical osteogenic distraction of the alveolar bone, and oral rehabilitation with an implant borne prosthesis. This case study also describes the 10-year follow-up of comprehensive multidisciplinary treatment and successful recovery of a patient's esthetic and functional aspects.


Assuntos
Regeneração Óssea/fisiologia , Implantes Dentários , Doenças Mandibulares/cirurgia , Ortodontia Corretiva/métodos , Osteogênese por Distração/métodos , Osteonecrose/cirurgia , Processo Alveolar/cirurgia , Criança , Dente Canino/lesões , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Feminino , Seguimentos , Fraturas Cominutivas/cirurgia , Humanos , Incisivo/lesões , Fraturas Mandibulares/cirurgia , Reconstrução Mandibular/métodos , Osteogênese por Distração/instrumentação , Complicações Pós-Operatórias/cirurgia , Avulsão Dentária/etiologia
7.
Int J Oral Maxillofac Implants ; 29(2): 321-30, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24683557

RESUMO

PURPOSE: The objective of this study was to describe bone healing around self-drilling orthodontic mini-implants (MIs), sterilized in an office with an autoclave, with or without immediate orthodontic loading. MATERIALS AND METHODS: One hundred forty-four self-drilling MIs (TOMAS, Dentaurum) were inserted into the tibiae of 18 white rabbits, with full-thickness flaps elevated under general anesthesia. An immediate load (50 cN) was applied to 50% of the MIs. Two rabbits were sacrificed soon after the surgery and served as a control group. Four rabbits each were sacrificed at 15, 21, 30, or 60 days after the surgeries. Digital radiographs were obtained to measure the cortical bone thickness (CBT) around and between the implants. Sections were obtained and stained for histologic and histomorphometric analysis. Bone quantity (BQ), bone-to-implant contact (BIC), and CBT were evaluated statistically. RESULTS: At day 0, fractures were visible in the cortical area around the MIs. At days 15 and 21, intense proliferation of woven bone followed by formation of lamellar bone was seen. After 30 days, primary bone was visible, with less proliferation activity. At day 60, primary bone in the process of remodeling into secondary bone was apparent. BQ was better with loading after 15 days and increased throughout the healing period in the loaded and unloaded groups. Loading did not influence the BIC values, which increased with healing time for loaded and unloaded implants. CBT increased in all regions, and CBT was greater around the MIs than between them except for unloaded MIs in the 15-day group. CONCLUSION: An immediate, light orthodontic load did not affect the bone healing process around orthodontic MIs. Osseointegration and CBT increased and were time-related.


Assuntos
Implantação Dentária/métodos , Implantes Dentários , Osseointegração/fisiologia , Cicatrização/fisiologia , Animais , Fenômenos Biomecânicos , Modelos Animais , Coelhos , Esterilização , Retalhos Cirúrgicos , Tíbia
8.
Dental press j. orthod. (Impr.) ; 19(1): 46-54, Jan-Feb/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-709646

RESUMO

OBJECTIVE: To assess the dentoskeletal changes observed in treatment of Class II, division 1 malocclusion patients with mandibular retrognathism. Treatment was performed with the Herbst orthopedic appliance during 13 months (phase I) and pre-adjusted orthodontic fixed appliance (phase II). METHODS: Lateral cephalograms of 17 adolescents were taken in phase I onset (T1) and completion (T2); in the first thirteen months of phase II (T3) and in phase II completion (T4). Differences among the cephalometric variables were statistically analyzed (Bonferroni variance and multiple comparisons). RESULTS: From T1 to T4, 42% of overall maxillary growth was observed between T1 and T2 (P < 0.01), 40.3% between T2 and T3 (P < 0.05) and 17.7% between T3 and T4 (n.s.). As for overall mandibular movement, 48.2% was observed between T1 and T2 (P < 0.001) and 51.8% between T2 and T4 (P < 0.01) of which 15.1% was observed between T2 and T3 (n.s.) and 36.7% between T3 and T4 (P < 0.01). Class II molar relationship and overjet were properly corrected. The occlusal plane which rotated clockwise between T1 and T2, returned to its initial position between T2 and T3 remaining stable until T4. The mandibular plane inclination did not change at any time during treatment. CONCLUSION: Mandibular growth was significantly greater in comparison to maxillary, allowing sagittal maxillomandibular adjustment. The dentoalveolar changes (upper molar) that overcorrected the malocclusion in phase I, partially recurred in phase II, but did not hinder correction of the malocclusion. Facial type was preserved. .


OBJETIVO: avaliar as alterações dentoesqueléticas observadas no tratamento da má oclusão de Classe II com retrognatismo mandibular, realizado com aparelho ortopédico de Herbst durante 13 meses (Fase I) e aparelho ortodôntico fixo pré-ajustado (Fase II). MÉTODOS: foram obtidas telerradiografias laterais de 17 adolescentes, ao início (T1), final da Fase I (T2), primeiros 13 meses da Fase II (T3) e término da Fase II (T4). As diferenças entre as variáveis cefalométricas foram analisadas estatisticamente (variância e comparações múltiplas de Bonferroni). RESULTADOS: de T1 a T4, do total da projeção da maxila, 42% foram observados de T1 a T2 (p < 0,01); 40,3% de T2 a T3 (p < 0,05); e 17,7% de T3 a T4 (n.s.). Do total da projeção da mandíbula, foi notado 48,2% de T1 a T2 (p < 0,001) e 51,8% de T2 a T4 (p < 0,01), sendo 15,1% (n.s.) de T2 a T3, e 36,7% de T3 a T4 (p < 0,01). A relação molar e a sobressaliência foram corrigidas idealmente. Em T4, todos apresentavam características de oclusão normal. O plano oclusal que de T1 a T2 rotacionou no sentido horário, de T2 a T3 retornou aos valores iniciais, mantendo-se estável até T4. A inclinação do plano mandibular, responsável pela caracterização do tipo facial, não alterou em nenhum tempo. CONCLUSÃO: a mandíbula cresceu significativamente mais que a maxila, favorecendo o ajuste sagital maxilomandibular. As mudanças dentárias (molares superiores), que sobrecorrigiram a má oclusão na Fase I, recidivaram parcialmente na Fase II, sem comprometer a correção da má oclusão. O tipo facial foi preservado. .


Assuntos
Adolescente , Criança , Feminino , Humanos , Masculino , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Funcionais , Retrognatismo/terapia , Cefalometria/métodos , Seguimentos , Mandíbula/crescimento & desenvolvimento , Mandíbula/patologia , Avanço Mandibular/instrumentação , Maxila/crescimento & desenvolvimento , Maxila/patologia , Dente Molar/patologia , Desenho de Aparelho Ortodôntico , Técnica de Expansão Palatina/instrumentação , Rotação , Resultado do Tratamento , Técnicas de Movimentação Dentária/instrumentação
9.
Dental press j. orthod. (Impr.) ; 18(6): 100-105, Nov.-Dec. 2013. tab
Artigo em Inglês | LILACS | ID: lil-697737

RESUMO

INTRODUCTION: Moyers analysis is widely used for analyzing mixed dentition, however, the accuracy of its theoretical probability tables has been recently questioned. Taking into consideration the fact the mixed dentition analysis is of paramount importance to precisely determine the space needed for alignment of canines and premolars, this research aimed at objectively assessing in the literature such an important step for orthodontic diagnosis. METHODS: A computerized search involving articles published on PubMed and Lilacs between 1990 and September, 2011 was conducted in accordance with the method described in the Cochrane 5.1.0 handbook. RESULTS: The research resulted in a sample composed of 629 articles. The inclusion criteria were: Articles using the Moyers analysis with a sample greater or equal to 40 patients. Conversely, the exclusion criteria were: Dental casts of patients with syndromes or oral cleft, researches conducted with a literature review, only, or clinical case reports and researches conducted before 1990. For this systematic review, 19 articles were selected. CONCLUSION: Based on the literature available, we can conclude that the Moyers mixed dentition analysis must be carefully used, since the majority of the articles analyzed showed that the probability of 75% was not as accurate as expected, leading to the need of adapting the probability levels depending on the study population.


INTRODUÇÃO: a análise de Moyers é amplamente adotada para a análise da dentição mista, porém, recentemente, a acurácia das suas tabelas de probabilidade está sendo questionada. OBJETIVO: sabendo-se da importância da análise da dentição mista, na determinação mais precisa possível do espaço necessário para o alinhamento de caninos e pré-molares, o objetivo dessa pesquisa foi avaliar de forma objetiva na literatura este importante passo do diagnóstico ortodôntico. MÉTODOS: foi realizado um levantamento computadorizado de artigos publicados entre os anos de 1990 a setembro de 2011 nas bases de dados PubMed e LILACS, segundo o método descrito no manual Cochrane 5.1.0. RESULTADOS: a estratégia de busca resultou em 629 artigos. Para ser selecionado, o artigo deveria utilizar a análise de Moyers e ter uma amostra superior ou igual a 40 pacientes. Os critérios de exclusão foram: modelos de gesso de pacientes com algum tipo de síndrome ou fissurados, pesquisas cuja proposta era apenas uma revisão da literatura ou apenas relato de um caso clínico, e pesquisas anteriores ao ano de 1990. Para essa revisão sistemática, 19 artigos foram selecionados. CONCLUSÕES: com base na literatura disponível, pode-se concluir que a utilização da análise de Moyers na análise da dentição mista deve ser utilizada de maneira cautelosa, pois, na maioria dos artigos avaliados, 75% não apresentou a acurácia desejada, necessitando de adaptações nos níveis de probabilidade, dependendo da população em estudo.


Assuntos
Humanos , Dente Pré-Molar/anatomia & histologia , Dente Canino/anatomia & histologia , Dentição Mista , Arco Dental/anatomia & histologia , Coroa do Dente/anatomia & histologia , Previsões , Probabilidade , Dente não Erupcionado/anatomia & histologia
10.
Dental press j. orthod. (Impr.) ; 18(6): 124-129, Nov.-Dec. 2013. ilus
Artigo em Inglês | LILACS | ID: lil-697741

RESUMO

OBJECTIVE: The present study was designed to verify if mini-implant prototypes (MIP) developed for Herbst appliance anchorage are capable of withstanding orthopedic forces, and to determine whether the flexural strength of these MIP varies depending on the site of insertion (maxilla and mandible). METHODS: Thirteen MIP were inserted in three minipig cadavers (six in the maxilla and seven in the mandible). The specimens were prepared and submitted to mechanical testing. The mean and standard deviation were calculated for each region. A two-way Student's t test was used to compare the strength between the sites. A one-way Student's t test was performed to test the hypothesis. Orthopedic forces above 1.0 kgf were considered. RESULTS: The MIP supported flexural strength higher than 1.0 kgf (13.8 ± 2.3 Kg, in the posterior region of the maxilla and 20.5 ± 5.2 Kg in the anterior region of the mandible) with a significantly lower flexural strength in the anterior region of the mandible (P < 0.05). CONCLUSION: The MIP are capable of withstanding orthopedic forces, and are more resistant in the anterior region of the mandible than in the posterior region of the maxilla in Minipigs br1 cadavers.


OBJETIVO: o presente estudo foi delineado para verificar se protótipos de mini-implantes (PMI) desenvolvidos para a ancoragem esquelética do aparelho de Herbst são capazes de suportar forças ortopédicas e, também, determinar a variação da força de flexão desses PMI de acordo com o local de inserção (maxila ou mandíbula). MÉTODOS: após o cálculo do tamanho da amostra, 13 PMI foram colocados em três cadáveres de Minipigs br1 (seis na maxila e sete na mandíbula). Os corpos de prova foram preparados e submetidos a um teste mecânico. Cálculos da média e o do desvio-padrão foram realizados para cada região. O teste t de Student para duas amostras não pareadas foi utilizado para comparar a resistência dos PMI entre as regiões de inserção. O teste t de Student para uma amostra foi realizado para o teste de hipótese. Foram consideradas forças ortopédicas aquelas acima de 1,0kgf. RESULTADOS: os PMI foram capazes de suportar forças de flexão maiores que 1,0kgf (13,8 ± 2,3Kg na região posterior da maxila, e 20,5 ± 5,2Kg na região anterior da mandíbula), apresentando significativa menor força de flexão na região anterior da mandíbula (p < 0,05). CONCLUSÃO: os PMI são capazes de suportar forças ortopédicas, sendo mais resistentes quando utilizados na região anterior da mandíbula do que na posterior da maxila, em cadáveres de Minipigs br1.


Assuntos
Animais , Implantes Dentários , Aparelhos Ortodônticos Funcionais , Procedimentos de Ancoragem Ortodôntica/instrumentação , Arco Dental/cirurgia , Análise do Estresse Dentário/instrumentação , Teste de Materiais , Miniaturização , Mandíbula/cirurgia , Maxila/cirurgia , Maleabilidade , Estresse Mecânico , Suínos , Porco Miniatura , Torque
11.
Braz. dent. j ; 24(4): 313-321, July-Aug/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-689826

RESUMO

This study evaluated the morphological changes in the temporomandibular joint (TMJ) condyles and calculated the Helkimo clinical dysfunction index (CDI) in adolescents with Class II Division 1 malocclusion and mandibular retrognathism treated with the Herbst appliance (phase I) and fixed orthodontic appliances (phase II). Thirty-two consecutive adolescents underwent phase I, and 23 completed phase II. The TMJs were evaluated qualitatively using magnetic resonance imaging (MRI) at the beginning of treatment (T1), during phase I (T2), at the end of phase I (T3) and at the end of phase II (T4). The CDI was calculated at T1, T3 and T4. From T1 to T3 (p=0.326), there were no changes in condyle morphology in 86.0% of the TMJs. From T3 to T4 (p<0.05) and T1 to T4 (p<0.05), changes occurred in 39.1% and 43.4% of the condyles. No significant changes in CDI occurred from T1 to T3, T3 to T4 and T1 to T4 (p=1.000; 86.6%, 76.2% and 76.2% concordance). After phase I, there were practically no changes in condyle morphology. At the end of phase II, a mild flattening was observed in some condyles. It may be concluded that no significant changes occurred in CDI after both treatment phases.


Este estudo avaliou as mudanças morfológicas nas cabeças da mandíbula das articulações temporo mandibulares (ATMs) e calculou o índex de disfunção clínico de Helkimo (IDC) em adolescentes com má oclusão de Classe II Divisão1 e retrognatismo mandibular, tratados com aparelho de Herbst (fase I) e aparelho ortodôntico fixo (fase II). Trinta e dois adolescentes consecutivos passaram pela fase I e 23 completaram a fase II. As ATMs foram avaliadas qualitativamente por meio de imagem da resonância magnética (IRM) ao início do tratamento (T1), durante a fase I (T2), no final da fase I (T3) e no final da fase II (T4). O IDC foi calculado em T1, T3 e T4. De T1 a T3 (p=0,326) não ocorreram mudanças na morfologia da cabeça da mandíbula em 86,0% das ATMs. De T3 a T4 (p<0,05) e T1 a T4 (p<0,05) ocorreram mudanças em 39,1% e 43,4% das cabeças das mandíbulas. Não ocorreram mudanças significantes no IDC de T1 a T3, T3 a T4 e T1 a T4 (p=1,000; 86,6%, 76,2% e 76,2% concordância). Após a fase I, não houve praticamente mudanças na morfologia da cabeça da mandíbula. Ao final da fase II, um leve aplainamento foi observado em algumas cabeças das mandíbulas. Pode ser concluído que não ocorreram mudanças significantes no IDC após ambas as fases de tratamento.


Assuntos
Adolescente , Criança , Feminino , Humanos , Masculino , Má Oclusão Classe II de Angle/terapia , Côndilo Mandibular/patologia , Aparelhos Ortodônticos Funcionais , Imageamento por Ressonância Magnética
12.
Rev. Clín. Ortod. Dent. Press ; 12(2): 101-112, abr.-maio 2013. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-855941

RESUMO

Introdução: paciente do sexo feminino, 38 anos de idade, leucoderma, brasileira portadora de deformidade dentofacial de classe II com retrognatismo mandibular, deficiência maxilar e distúrbios articulares, apresentando sintomatologia da ATM de caráter crônico e incapacitante por causa das dores. O diagnóstico foi realizado com auxílio de placa miorrelaxante e confirmação da remissão dos sintomas. A análise do deslocamento real dos côndilos foi realizada com um Condylar Position Indicator (CPI), obtendo, assim, a diferença entre a MIC e a RC. Objetivo: evidenciar a importância dos meios de diagnóstico no tratamento ortodôntico-cirúrgico. Métodos: foram avaliadas as verdadeiras discrepâncias antes do tratamento com montagem no articulador semiajustável. O tratamento realizado foi o ortodôntico-cirúrgico. Resultados: foram alcançados os objetivos clínicos que eram o equilíbrio oclusal, articular, remissão dos sintomas e, consequentemente, a harmonia facial.


Assuntos
Humanos , Feminino , Adulto , Relação Central , Diagnóstico Bucal , Má Oclusão Classe II de Angle/cirurgia , Placas Oclusais , Retrognatismo/cirurgia , Transtornos da Articulação Temporomandibular/cirurgia
13.
Dental press j. orthod. (Impr.) ; 18(2): 55-60, Mar.-Apr. 2013. tab
Artigo em Inglês | LILACS | ID: lil-683184

RESUMO

OBJECTIVE: This study compared the clinical performance of orthodontic brackets bonded with Transbond adhesive paste after two priming systems: a two-stage conventional system (acid etching + Transbond XT adhesive primer) and a singlestage self-etching primer (SEP) (Transbond Plus). METHODS: The sample comprised 480 metal brackets bonded to the teeth of 24 consecutive patients treated for 36 to 48 months. A split-mouth design was used for bonding, and both systems were used in each patient. Bracket failure rates for each system were analyzed; and failure causes as reported by the patients and the quadrant of teeth for which brackets failed were recorded. RESULTS: The conventional system group had a failure rate of 5.41%, whereas the rate for SEP was 4.58%. In this group, there were 5 failures (38.4%) in the right maxillary quadrant, 2 (15.4%) in the left maxillary quadrant, 4 (30.8%) in the right mandibular quadrant, and 2 (15.4%) in the left mandibular quadrant. In the SEP group, there were 4 (36.4%) failures in the right maxillary quadrant, 1 (9%) in the left maxillary quadrant, 3 (27.3%) in the right mandibular quadrant, and 3 (27.3%) in the left mandibular quadrant. Results of descriptive statistical analysis and odds ratio did not show any significant differences between rates (p = 0.67). CONCLUSION: The clinical efficiency of SEP was similar to that of the conventional system.


OBJETIVO: o objetivo do presente estudo foi comparar o desempenho clínico da colagem de braquetes ortodônticos com resina Transbond (3M Unitek) associada a dois sistemas adesivos: convencional em duas etapas (ataque ácido + Transbond XT adhesive Primer) e Self-Etching Primer (SEP), em etapa única (Transbond Plus). MÉTODOS: a amostra foi constituída de 480 braquetes metálicos (Victory, 3M Unitek), colados em 24 pacientes, que foram tratados durante um período de 36 a 48 meses. A colagem foi feita por meio do sistema split-mouth, utilizando os dois sistemas de colagem em cada paciente. Foi analisada a taxa de queda dos braquetes para cada sistema de colagem, descrita a causa da queda conforme relato do paciente e a posição dos dentes nas arcadas. RESULTADOS: o sistema adesivo convencional apresentou taxa de queda de 5,41%, enquanto a do SEP foi de 4,58%. O sistema convencional apresentou 5 quedas (38,4%) no quadrante superior direito, 2 (15,4%) no quadrante superior esquerdo, 4 (30,8%) no quadrante inferior direito e 2 (15,4%) no quadrante inferior esquerdo. O SEP apresentou 4 quedas (36,4%) no quadrante superior direito, 1 (9%) no quadrante superior esquerdo, 3 (27,3%) no quadrante inferior direito e 3 (27,3%) no quadrante inferior esquerdo. Por meio da análise estatística descritiva e do teste Odds Ratio, constatou-se que não houve diferença significativa entre essas taxas (p = 0,67). CONCLUSÃO: com base nesses resultados, pode-se concluir que o sistema adesivo SEP apresentou eficácia clínica semelhante à do sistema adesivo convencional.


Assuntos
Humanos , Condicionamento Ácido do Dente/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Colagem Dentária/métodos , Braquetes Ortodônticos , Cimentos de Resina/química , Análise do Estresse Dentário , Análise de Falha de Equipamento , Teste de Materiais , Razão de Chances
14.
Rev. Assoc. Paul. Cir. Dent ; 66(4): 260-267, out.-dez. 2012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-668658

RESUMO

A complexidade do tratamento definirá a necessidade de uma abordagem interdisciplinar para alcançar resultados de sucesso. Quando se associa perdas dentárias, perda do relacionamento oclusal, mau posicionamento dentário, ao descontrole do estado geral da saúde bucal como, por exemplo, a perda de inserção devido à doença periodontal, a decisão da proposta de tratamento merece cuidados e o prognóstico de uma etapa do tratamento depende do su- cesso de outra. Desta forma, no caso a seguir, as disciplinas de Ortodontia do Departamento de Ortodontia e Odontopediatria e de Clínica Integrada do Departamento de Estomatologia da Faculdade de Odontologia da Universidade de São Paulo (Fousp), de maneira interdisciplinar, foram determinantes para o sucesso da reabilitação do paciente. Após a fase de controle da saúde bucal iniciou-se o tratamento ortodôntico fixo em ambas as arcadas. Concluída a movimentação dentária com fechamento dos diastemas e nivelamento oclusal (cerca de 24 meses) e sua manutenção, iniciou-se a fase reabilitadora do tratamento, com um minucioso estudo com a finalidade de apresentar alternativas para o tratamento protético.


The complexity of the treatment will define the necessity of an interdisciplinary approach to achieve successful results. The association between tooth loss, loss of occlusal relationship, bad teeth positioning, with the lack of the general state of oral health such as insertion loss due to periodontal disease, the decision of the proposed treatment deserves care and prognosis of a stage of treatment depends on the success of a nother. Th us, i n the followi ng case, the Orthodontics Department of Orthodontics and Pediatric Dentistry and Integrated Clinic, Department of Stomatology, School of Dentistry, University of São Paulo, in an interdisciplinary way, were crucial to the success of rehabilitation. After the stage of the oral health control began the fixed orthodontic treatment in both arches. Complete tooth movement with diastemas resolution and occlusalleveling (about 24 months) and their maintenance, the rehabilitative phase of treatment started, with a detailed study with the purpose of presenting of prosthetic treatment alternatives.


Assuntos
Humanos , Masculino , Implantes Dentários , Prótese Dentária , Ortodontia Corretiva
15.
RPG rev. pos-grad ; 19(2): 81-87, abr.-jun. 012. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-688230

RESUMO

Tendo em vista a falta de detalhamento minucioso na literatura existente, este relato descreve uma metodologia modificada de preparo das amostras de osso contendo implantes metálicos, para análise por microscopia óptica, fluorescência ou polarização. Os fragmentos de osso contendo os implantes são fixados, desidratados e incluídos em resina metilmetacrilato para finalmente serem cortados. As secções obtidas são colocadas em lâminas de acrílico e reduzidas à espessura desejada de 20 a 50 um utilizando de lixas d'água para o desgaste e polimento da superfície. Esta técnica produz lâminas histológicas de excelente qualidade, sem danos à interface osso-implante, e que permite observação detalhada da arquitetura tecidual, dos tipos celulares presentes e dos fluocromos. Stevenels blue contracorada por Alizarina red S31 são colorações descritas que permitem em microscopia óptica diferenciar tipos celulares e teciduais presentes no sítio do implante


Assuntos
Osso e Ossos , Corantes , Implantes Dentários , Histologia , Polimetil Metacrilato
16.
Ortodontia ; 45(2): 179-185, mar.-abr. 2012. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-713970

RESUMO

O objetivo da apresentação deste caso clínico foi avaliaros efeitos do tratamento de um paciente que apresentava má-oclusãode Classe II associada a retrognatismo mandibular com padrão decrescimento favorável, tratado com aparelho de ancoragem extrabucale aparelhagem fixa durante 36 meses. Comparando os achados clínicose radiográficos do início ao término do tratamento, observou-secorreção da má-oclusão com expressivo crescimento mandibular econsequente redução da convexidade facial. Baseado nos resultadosobtidos, pôde-se concluir que para este paciente o tratamento comancoragem extra bucal seguido de aparelhagem fixa foi eficiente nacorreção da má-oclusão de Classe II associada ao retrognatismomandibular em uma avaliação em longo prazo.


The objective of this case report was to evaluate thetreatment effects, in a patient with Class II division 1 malocclusion associatedwith mandibular retrognathia, treated with headgear anchorageand orthodontic fixed appliances in a period of 36 months of duration.Comparing the clinical and radiographic findings from the beginning tothe end of the treatment, it was observed the complete correction ofthe malocclusion, with expressive mandibular growth. and consequentreduction in facial convexity. 8ased on these results, can be concludedthat, for this patient, the treatment with headgear followed by fixed eoplianceswas effective, in a long-term assessment, in correcting ClassII malocclusion associated with mandibular retrognathia.


Assuntos
Humanos , Masculino , Adolescente , Má Oclusão Classe II de Angle/terapia , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos , Retrognatismo
17.
Braz. dent. j ; 23(4): 433-437, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-658023

RESUMO

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.


O objetivo deste estudo foi comparar os efeitos dos lacebacks ativos e passivos na posição ântero-posterior dos primeiros molares e dos incisivos centrais superiores durante a fase de nivelamento. Vinte e três indivíduos com má oclusão de Classes I e II foram tratados com extrações dos primeiros pré-molares utilizando aparelhos fixos pré-ajustados (bráquetes MBT 0,022"). A fase de nivelamento foi realizada somente com arcos de aço inoxidável. A amostra foi dividida em 2 grupos: 14 pacientes receberam lacebacks ativos (Grupo 1) e 9 pacientes receberam lacebacks passivos (Grupo 2). Os lacebacks foram feitos com fio de ligadura de 0,008" (0,20 mm). Telerradiografias laterais foram realizadas antes e após a fase de nivelamento. O teste t de Student foi aplicado para determinar as diferenças entre as médias de deslocamento entre os períodos pré e pós-nivelamento e para determinar as diferenças entre os grupos. No Grupo 1, o primeiro molar mostrou uma movimentação mesial significativa enquanto nenhuma alteração foi observada no Grupo 2. Em ambos os grupos, os incisivos centrais superiores foram lingualizados. Em conclusão, os lacebacks ativos produziram perda de ancoragem nos primeiros molares superiores enquanto que os lacebacks passivos não afetaram a posição destes dentes. Lacebacks ativos e passivos foram efetivos para prevenir a vestibularização dos incisivos centrais superiores.


Assuntos
Adolescente , Criança , Feminino , Humanos , Masculino , Incisivo/patologia , Dente Molar/patologia , Procedimentos de Ancoragem Ortodôntica/instrumentação , Técnicas de Movimentação Dentária/instrumentação , Dente Pré-Molar/cirurgia , Cefalometria/métodos , Ligas Dentárias/química , Seguimentos , Maxila , Má Oclusão Classe I de Angle/terapia , Má Oclusão Classe II de Angle/terapia , Fios Ortodônticos , Aço Inoxidável/química , Extração Dentária , Coroa do Dente/patologia , Raiz Dentária/patologia
18.
Dental press j. orthod. (Impr.) ; 16(5): 74-81, set.-out. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-610763

RESUMO

OBJETIVO: estudar os efeitos do nivelamento realizado com fios de NiTi termoativado e de aço inoxidável, avaliando-se as possíveis alterações na posição dos incisivos inferiores, em casos com extrações, correlacionando com o tempo de tratamento. MÉTODOS: a amostra foi composta de 36 indivíduos, de ambos os sexos, leucodermas brasileiros, com idade média inicial de 15 anos e 5 meses, portadores de más oclusões de Classes I e II, distribuídos em dois grupos. No Grupo 1 (n=17), o nivelamento foi realizado com a sequência 1, utilizando-se três fios - 0,016" e 0,019"x0,025" de NiTi termoativado, e 0,019"x0,025" de aço inoxidável. No Grupo 2 (n=19), foi testada a sequência 2, na qual foram utilizados apenas fios de aço inoxidável (0,014"; 0,016"; 0,018"; 0,020" e 0,019"x0,025" com torque passivo nos incisivos inferiores). Os dados foram coletados utilizando-se o método cefalométrico computadorizado e comparados pelo teste t de Student com o nível de significância de 5 por cento. RESULTADOS: no Grupo 1, os incisivos inferiores inclinaram-se para lingual, com movimento significativo apenas da coroa (1,6mm). No Grupo 2, os incisivos inferiores permaneceram estáveis. Não houve alteração vertical em nenhum dos grupos. CONCLUSÕES: a sequência 2 proporcionou um melhor controle dos incisivos inferiores, não alterando suas posições iniciais, enquanto a sequência 1 permitiu a expressão do torque da prescrição utilizada, levando a uma inclinação lingual desses dentes. O tempo de tratamento foi menor utilizando-se a sequência 1. As variações biomecânicas estudadas apresentaram vantagens e desvantagens que devem ser conhecidas e ponderadas pelo ortodontista no planejamento do caso.


OBJECTIVE: Investigate the effects of heat-activated NiTi and stainless steel wires to evaluate potential changes in the position of mandibular incisors in extraction cases as correlated with treatment length.METHOD: The sample consisted of 36 individuals of both genders, Brazilian Caucasians with mean initial age of 15 years and 5 months with Class I and Class II malocclusions, divided into two groups. In Group 1 (n=17) leveling was performed with Sequence 1, comprised of three different wire cross-sections: 0.016-in and 0.019 x 0.025-in heat-activated NiTi wires and 0.019 x 0.025-in stainless steel wires. In Group 2 (n=19) Sequence 2 was tested using only stainless steel wires (0.014-in, 0.016-in, 0.018-in, 0.020-in and 0.019 x 0,025-in) with passive torque in the mandibular incisors. Data were collected using computerized cephalometry and compared using Student's t-test with 5% significance level.RESULTS: In Group 1, mandibular incisors were inclined lingually although only the crowns showed significant movement (1.6 mm). In Group 2, mandibular incisors remained stable. No vertical changes were noted in either group.CONCLUSIONS: Sequence 2 yielded better mandibular incisor control with no changes in their initial positions, while Sequence 1 allowed torques in the bracket prescription to be expressed, leading to the lingual inclination of these teeth. Treatment length was shorter when Sequence 1 was used. The evaluated biomechanic variations presented advantages and disadvantages that should be known and considered by the orthodontist during treatment planning.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Fenômenos Biomecânicos , Fios Ortodônticos/efeitos adversos , Incisivo , Má Oclusão , Níquel , Aço Inoxidável , Titânio
19.
Int J Oral Maxillofac Implants ; 26(4): 860-5, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21841996

RESUMO

PURPOSE: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereolithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. MATERIALS AND METHODS: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. RESULTS: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. CONCLUSIONS: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures.


Assuntos
Parafusos Ósseos , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional/métodos , Modelos Anatômicos , Procedimentos Cirúrgicos Bucais/métodos , Procedimentos de Ancoragem Ortodôntica/instrumentação , Marcadores Fiduciais , Humanos , Mandíbula/cirurgia , Maxila/cirurgia , Placas Oclusais , Procedimentos Cirúrgicos Bucais/instrumentação , Planejamento de Assistência ao Paciente , Projetos Piloto
20.
Dental press j. orthod. (Impr.) ; 15(4): 38e1-38e6, jul.-ago. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-555731

RESUMO

OBJETIVO: o propósito do presente estudo é avaliar o limite de resistência à flexão de um protótipo de mini-implante desenvolvido para ancoragem do aparelho de Herbst. MÉTODOS: após a realização de um cálculo do tamanho da amostra, quatro corpos de prova contendo os protótipos de mini-implantes foram submetidos a uma força de flexão por engastamento simples, utilizando-se uma máquina universal de ensaios mecânicos, sendo calculado o limite de resistência à força de flexão. RESULTADOS: após os ensaios mecânicos, os novos mini-implantes apresentaram o limite de resistência à força de flexão de 98,2kgf, que foi o menor valor encontrado. CONCLUSÃO: os protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst foram capazes de suportar forças de flexão maiores do que as forças de mordida descritas na literatura.


AIM: The purpose of this study was to evaluate the limit of flexural strength of a mini-implant prototype designed for Herbst appliance anchorage. METHODS: After sample size calculation, four specimens with the new mini-implant were submitted to a single cantilever flexure test using a universal testing machine. The limit of flexural force strength was calculated. RESULTS: The mini-implant prototype showed a limit of flexural force strength of 98.2 kgf (982 N), that was the lowest value found. CONCLUSION: The mini-implant prototype designed for Herbst appliance anchorage can withstand flexural forces higher than the maximum human bite forces reported in the literature.


Assuntos
Implantação Dentária , Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos , Ortodontia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA