1.
Phys Med ; 120: 103325, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38493583

RESUMO

PURPOSE: The present study aimed to develop a porous structure with plug-ins (PSP) to broaden the Bragg peak width (BPW, defined as the distance in water between the proximal and distal 80% dose) of the carbon ion beam while maintaining a sharp distal falloff width (DFW, defined as the distance along the beam axis where the dose in water reduces from 80% to 20%). METHODS: The binary voxel models of porous structure (PS) and PSP were established in the Monte Carlo code FLUKA and the corresponding physical models were manufactured by 3D printing. Both experiment and simulation were performed for evaluating the modulation capacity of PS and PSP. BPWs and DFWs derived from each integral depth dose curves were compared. Fluence homogeneity of 430 MeV/u carbon-ion beam passing through the PSP was recorded by analyzing radiochromic films at six different locations downstream the PSP in the experiment. Additionally, by changing the beam spot size and incident position on the PSP, totally 48 different carbon-ion beams were simulated and corresponding deviations of beam metrics were evaluated to test the modulating stability of PSP. RESULTS: According to the measurement data, the use of PSP resulted in an average increase of 0.63 mm in BPW and a decrease of 0.74 mm in DFW compared to PS. The 2D radiation field inhomogeneities were lower than 3 % when the beam passing through a ≥ 10 cm PMMA medium. Furthermore, employing a spot size of ≥ 6 mm ensures that beam metric deviations, including BPW, DFW, and range, remain within a deviation of 0.1 mm across various incident positions. CONCLUSION: The developed PSP demonstrated its capability to effectively broaden the BPW of carbon ion beams while maintaining a sharp DFW comparing to PS. The superior performance of PSP, indicates its potential for clinical use in the future.


Assuntos
Radioterapia com Íons Pesados , Terapia com Prótons , Método de Monte Carlo , Porosidade , Radioterapia com Íons Pesados/métodos , Carbono , Água , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos
2.
J Appl Clin Med Phys ; 24(11): e14107, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37563859

RESUMO

BACKGROUND: Monte Carlo (MC) code FLUKA possesses widespread usage and accuracy in the simulation of particle beam radiotherapy. However, the conversion from computer-aided design (CAD) mesh format models to FLUKA readable geometries could not be implemented directly and conveniently. A simple method was required to be developed. PURPOSE: The present study proposed a simple method to voxelize CAD mesh format files by using a Python-based script and establishing geometric models in FLUKA. METHODS: Five geometric models including cube, sphere, cone, ridge filter (RGF), and 1D-Ripple Filter (1D-RiFi) were created and exported as CAD mesh format files (.stl). An open-source Python-based script was used to convert them into voxels by endowing X, Y, and Z (following the Cartesian coordinates system) of solid materials in the three-dimensional (3D) grid. A FLUKA (4-2.2, CERN) predefined routine was used to establish the voxelized geometry model (VGM), while Flair (3.2-1, CERN) was used to build the direct geometry model (DGM) in FLUKA for comparison purposes. Uniform carbon ion radiation fields 8×8 cm3 and 4×4 cm3 were generated to transport through the five pairs of models, 2D and 3D dose distributions were compared. The integral depth dose (IDD) in water of three different energy levels of carbon ion beams transported through 1D-RiFis were also simulated and compared. Moreover, the volume between CAD mesh and VGMs, as well as the computing speed between FLUKA DGMs and VGMs were simultaneously recorded. RESULTS: The volume differences between VGMs and CAD mesh models were not more than 0.6%. The maximum mean point-to-point deviation of IDD distribution was 0.7% ± 0.51% (mean ± standard deviation). The 3D dose Gamma-index passing rates were never lower than 97% with criteria of 1%-1 mm. The difference in computing CPU time was 2.89% ± 0.22 on average. CONCLUSIONS: The present study proposed and verified a Python-based method for converting CAD mesh format files into VGMs and establishing them in FLUKA simply as well as accurately.


Assuntos
Radiometria , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Simulação por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Carbono/uso terapêutico , Desenho Assistido por Computador , Método de Monte Carlo
3.
J Appl Clin Med Phys ; 23(9): e13656, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35635548

RESUMO

PURPOSE: To quantify the influence of beam optics asymmetric distribution on dose. METHODS: Nine reference cubic targets and corresponding plans with modulation widths (M) of 3, 6, and 9 cm and with center depths (CDs) of 6, 12, and 24 cm were generated by the treatment planning system (TPS). The Monte Carlo code FLUKA was used for simulating the dose distribution from the aforementioned original plans and the dose perturbation by varying ±5%, ±15%, ±20%, ±25%, and ±40% in spot full width half maximum to the X-direction while keeping consistent in the Y-direction. The dosimetric comparisons in dose deviation, γ-index analysis, lateral penumbra, and flatness were evaluated. RESULTS: The largest 3D absolute mean deviation was 15.0% ± 20.9% (mean ± standard deviation) in M3CD6, whereas with the variation from -15% to +20%, the values were below 5% for all cube plans. The lowest 2D γ-index passing rate was 80.6% with criteria of 2%-2 mm by a +40% variation in M3CD6. For the M9CD24 with a -40% variation, the maximum 1D dose deviations were 5.6% and 15.7% in the high-dose region and the edge of the radiation field, respectively. The maximum deviations of penumbra and flatness were 3.4 mm and 11.4%, respectively. CONCLUSIONS: The scenario of beam optics asymmetric showed relatively slight influence on the global dose distribution but severely affected dose on the edge of the radiation field. For scanning carbon-ion therapy facilities, beam spot lateral profile settings in TPS base data should be properly handled when beam optics asymmetry variation is over 15%.


Assuntos
Radioterapia com Íons Pesados , Terapia com Prótons , Carbono , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador