Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 2860, 2024 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-38310154

RESUMO

Type 2 diabetes interferes with bone remodeling mechanisms, requiring studies to reverse this damage, and resveratrol is a polyphenol with rich properties. This study aimed to characterize the long bone morphology and peri-implant biomechanics of normoglycemic and type 2 diabetic animals treated with resveratrol. Thirty-two male Wistar rats were used and divided into normoglycemic and diabetic with or without treatment. They had the installation of implants in the tibia and treatment with oral resveratrol within 45 days. Resveratrol was responsible for weight homeostasis and decreased glycemic levels in rats with type 2 diabetes. The three-point bending testing, resveratrol showed positive effects on the biomechanics of long bones, corroborating a more resistant bone in comparison to untreated diabetics. Micro-ct revealed how bone metabolism is affected by systemic disease, decreasing bone quality. The counter-torque of normoglycemic animals showed superior osseointegration to diabetes, with no differences in the administration of the polyphenol, showing the sovereignty of the deleterious effects of the disease when there is a tissue lesion and an inflammatory picture installed. Overall, resveratrol acted positively in the etiopathogenesis of type 2 diabetes and revealed positive effects on the strength of long bones.


Assuntos
Implantes Dentários , Diabetes Mellitus Experimental , Diabetes Mellitus Tipo 2 , Ratos , Masculino , Animais , Resveratrol/farmacologia , Ratos Wistar , Diabetes Mellitus Tipo 2/patologia , Diabetes Mellitus Experimental/patologia , Osso e Ossos , Osseointegração , Tíbia/patologia , Titânio/farmacologia
2.
J Mech Behav Biomed Mater ; 141: 105757, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36924612

RESUMO

PURPOSE: This in vitro study evaluated the influence of antimicrobial photodynamic therapy (aPDT), using methylene blue (MB) as photosensitizer (PS) and calcium hydroxide (CH) as intracanal medication on adhesive bond strength, sealing, and integrity of the luting interface of glass-fiber posts to different thirds of endodontically treated root canal dentin. MATERIAL AND METHODS: 102 incisors were sorted into 6 groups: a negative control irrigated with deionized water; a positive control irrigated with deionized water and filled with CH; CH + MB 50 mg/L without laser radiation; CH + MB 100 mg/L without laser radiation; CH + MB 50 mg/L radiated by red laser; and CH + MB 100 mg/L radiated by red laser. Push-out bond strength (n = 8), adhesive interface sealing (n = 3), and volume and quantification of voids (n = 6) were assessed using a universal testing machine, confocal laser scanning microscope, and computerized microtomography, respectively. Scanning electron micrographs were obtained from representative samples to qualify the fracture patterns. Push-out bond strength and adhesive interface integrity data were subjected to 2-way ANOVA for repeated measures followed by Tukey's test (α = 0.05). Adhesive interface sealing was evaluated by the inter-examiner Kappa test and submitted to Kruskal-Wallis and Dunns tests (α = 0.05). RESULTS: Assessing the apical region, the positive control and MB100WA + Ca(OH)2 groups showed lower adhesive bond strength compared to the MB100A + Ca(OH)2 group (P < 0.05). The cervical third showed higher bond strength than the apical third for the positive control, MB50WA + Ca(OH)2, MB100WA + Ca(OH)2, and MB50A + Ca(OH)2 groups (P < 0.05). A prevalence of mixed failure was observed in all experimental groups. There were no statistically significant differences in adhesive interface sealing for any of the parameters assessed (P > 0.05). MB100WA + Ca(OH)2 and MB100A + Ca(OH)2 groups promoted a higher volume and quantification of voids compared to the negative control group evaluating the cervical third (P < 0.05). In general, there were no differences in the quantification of voids comparing the intraradicular thirds (P > 0.05), differently to the volume of voids in which, in general, the cervical third promoted higher values compared to the middle and apical thirds (P < 0.05). CONCLUSION: aPDT with methylene blue PS at 50 mg/L associated with calcium hydroxide as intracanal medication demonstrated satisfactory bond strength, sealing, and integrity of the adhesive interface at any intraradicular depth.


Assuntos
Colagem Dentária , Fotoquimioterapia , Hidróxido de Cálcio , Adesivos , Azul de Metileno , Fotoquimioterapia/métodos , Vidro/química , Dentina , Água , Teste de Materiais , Cimentos de Resina/química
3.
Photodiagnosis Photodyn Ther ; 37: 102650, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34838697

RESUMO

BACKGROUND: Photodynamic therapy with photosensitizers can reduce the microbial load. However, few studies have evaluated the effects of photosensitizers on the color stability of endodontically treated intraradicular dentin. This in vitro study investigated the effects of methylene blue and curcumin photosensitizers used in photodynamic therapy on the color stability of intraradicular dentin. METHODS: Sixty human incisors were divided into three experimental groups according to the photosensitizer solutions used and their concentrations: methylene blue (25 mg/L), curcumin (1000 mg/L), and curcumin (1500 mg/L). The color stability of endodontically treated intraradicular dentin was evaluated using a portable reflectance spectrophotometer before and after the samples been storage in 2 mL of the photosensitizer solutions during 5 min (n = 20). Color stability data were subjected to a normality test, and statistical analysis was performed using the one-way analysis of variance and Tukey least significant difference test (α = 0.05). RESULTS: Samples treated with 25 mg/L methylene blue photosensitizer showed a higher level of color alteration than those stored in 1000 mg/L curcumin (p = .03322). However, there was no significant difference in the color alteration profiles between the samples treated with 25 mg/L methylene blue and 1500 mg/L curcumin (p = .36428). Furthermore, there was no difference in the color alteration profiles between the dentin samples immersed in 1000 mg/L and 1500 mg/L curcumin photosensitizer solutions (p = .45321). CONCLUSIONS: Methylene blue and curcumin photosensitizers influenced the color stability of endodontically treated intraradicular dentin, and this color alteration exceeded the clinical acceptability threshold. Samples treated with 25 mg/L methylene blue showed the highest level of color alteration.


Assuntos
Curcumina , Fotoquimioterapia , Curcumina/farmacologia , Dentina , Humanos , Teste de Materiais , Azul de Metileno/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia
4.
Clin Oral Investig ; 26(3): 2527-2536, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34654942

RESUMO

OBJECTIVES: Although bleaching therapy is considered a dose-dependent treatment, the effect of the volume of product used is yet to be studied. This study thus aimed to evaluate the influence of bleaching gel volume on chromatic alteration and postoperative sensitivity. METHODOLOGY: Thirty patients were selected and allocated into three groups; the lower canines were analyzed according to the volume of gel used: GI-0.025 mL, GII-0.05 mL, and GIII-0.10 mL. Chromatic alteration analysis was performed using a portable digital spectrophotometer by calculating the ΔE, ΔE00, ΔL*, Δa*, and Δb* values and the whiteness index (WID). Spontaneous sensitivity was assessed using a questionnaire, and sensitivity was stimulated by thermo-sensory analysis. Analyses were conducted in five stages: baseline, after 1st, 2nd, and 3rd bleaching sessions, and 14 days after the end. Data were analyzed using the two-way ANOVA test with repeated measures and Tukey's post hoc test (p < 0.05). RESULTS: It was observed that ΔE, ΔE00, and ΔL* were similar between groups at the end of the bleaching therapy; and the values of Δa*, Δb*, and WID were higher in the GIII group. For sensitivity, it was found that the GI was the one with the lowest values; o GII intermediate values; while the GIII group presents the highest values of spontaneous and stimulated sensitivity. CONCLUSION: Gel volume influenced the response to bleaching and significantly influenced the spontaneous sensitivity and cold stimulus. CLINICAL RELEVANCE: The amount of bleaching gel used during therapy is key to both the response to color change and postoperative sensitivity.


Assuntos
Clareadores Dentários , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio , Ácido Hipocloroso , Espectrofotometria , Clareadores Dentários/uso terapêutico
5.
Braz. oral res. (Online) ; 34: e063, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132657

RESUMO

Abstract This in vitro study aimed to evaluate the effects of different luting protocols on the thickness of luting interface of ceramic laminate veneers. Thirty-six lithium disilicate blocks (7 × 8 × 0.6 mm) were cemented onto bovine enamel. They were divided into 6 groups based on the luting protocol (no previous photoactivation of the dental adhesive; previous activation of the dental adhesive only on enamel surface; and previous photoactivation of the dental adhesive on both the enamel surface and inner surface of ceramic laminate) and the luting materials used (Single Bond Universal/RelyX Veneer and Tetric N Bond/Variolink Veneer). The luting interface thickness of ceramic laminate veneers was evaluated using a laser scanning confocal microscope (n = 6). The luting interface measurements were analyzed using 2-way ANOVA and the Tukey least significant difference test (α = 0.05). Prior activation of the adhesive on the dental enamel and inside the ceramic laminate exhibited higher luting interface thickness than that with no prior photoactivation of both luting materials (p < 0.05). Specimens cemented with Tetric N Bond/Variolink Veneer, submitted for prior photoactivation of the adhesive on the dental enamel and on both dental enamel and inner surface of ceramic, exhibited lower luting interface thickness than those luted with Single Bond Universal/RelyX Veneer (p < 0.05). The prior photoactivation of dental adhesives influenced the thickness of luting interface in laminate restorations. Tetric N Bond/Variolink Veneer yielded more satisfactory results than Single Bond Universal/RelyX Veneer when the adhesive was light activated.


Assuntos
Animais , Bovinos , Cerâmica , Teste de Materiais , Colagem Dentária , Cimentos de Resina , Cimentos Dentários , Facetas Dentárias
6.
Artigo em Inglês | MEDLINE | ID: mdl-24451853

RESUMO

PURPOSE: This study evaluated and compared bone heating, drill deformation, and drill roughness after several implant osteotomies in the guided surgery technique and the classic drilling procedure. MATERIALS AND METHODS: The tibias of 20 rabbits were used. The animals were divided into a guided surgery group (GG) and a control group (CG); subgroups were then designated (G0, G1, G2, G3, and G4, corresponding to drills used 0, 10, 20, 30 and 40 times, respectively). Each animal received 10 sequential osteotomies (5 in each tibia) with each technique. Thermal changes were quantified, drill roughness was measured, and the drills were subjected to scanning electron microscopy. RESULTS: Bone temperature generated by drilling was significantly higher in the GG than in the CG. Drill deformation in the GG and CG increased with drill use, and in the CG a significant difference between G0 and groups G3 and G4 was observed. In the GG, a significant difference between G0 and all other groups was found. For GG versus CG, a significant difference was found in the 40th osteotomy. Drill roughness in both groups was progressive in accordance with increased use, but there was no statistically significant difference between subgroups or between GG and CG overall. CONCLUSION: During preparation of implant osteotomies, the guided surgery technique generated a higher bone temperature and deformed drills more than the classic drilling procedure. The increase in tissue temperature was directly proportional to the number of times drills were used, but neither technique generated critical necrosis-inducing temperatures. Drill deformation was directly proportional to the number of times the drills were used. The roughness of the drills was directly proportional to the number of reuses in both groups but tended to be higher in the GG group.


Assuntos
Implantação Dentária Endóssea/instrumentação , Instrumentos Odontológicos , Análise de Falha de Equipamento/métodos , Temperatura Alta , Osteotomia/instrumentação , Tíbia/cirurgia , Animais , Instrumentos Odontológicos/estatística & dados numéricos , Reutilização de Equipamento/estatística & dados numéricos , Temperatura Alta/efeitos adversos , Masculino , Microscopia Eletrônica de Varredura , Osteonecrose/etiologia , Coelhos , Tíbia/patologia
7.
J Craniofac Surg ; 23(6): e631-4, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23172504

RESUMO

The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention screws of tapered abutments and cylinders of Morse taper implants submitted to retightening and detorque measurements. Two groups were obtained (n = 12): group I-tapered abutment connected to the implant with titanium retention screw and group II-cylinder with metallic base connected to tapered abutment with titanium retention screw. The detorque values were measured by an analogic torque gauge after 3 minutes of torque insertion. The detorque was measured 10 times for each retention screw of groups I and II, totalizing 120 detorque measurements in each group. Data were submitted to ANOVA and Fisher exact test (P < 0.05). Both groups presented reduced detorque value (P < 0.05) in comparison to the insertion torque in all measurement periods. There was a statistically significant difference (P < 0.05) between the detorque values of the first measurement and the other measurement periods for the abutment screw. However, there was no statistically significant difference (P > 0.05) for the detorque values of all measurement periods for the cylinder screw. In conclusion, the abutment and cylinder screws exhibited torque loss after insertion, which indicates the need for retightening during function of the implant-supported prostheses.


Assuntos
Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Dente Suporte , Implantes Dentários , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Fatores de Tempo , Titânio , Torque
8.
J Craniofac Surg ; 22(5): 1913-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21959465

RESUMO

The biologic width is an essential dental space that always needs to be maintained to ensure periodontal health in any dental prosthetic restorations. An iatrogenic partial fixed prosthesis constructed in lower posterior teeth predisposed the development of subgingival caries, which induced violation of the biologic width in involved teeth, resulting in an uncontrolled inflammatory process and periodontal tissue destruction. This clinical report describes a periodontal surgical technique to recover a violated biologic width in lower posterior teeth, by crown lengthening procedure associated with free gingival graft procedure, to ensure the possibility to place a modified partial fixed prosthesis in treated area. The procedure applied to recover the biologic width was crown lengthening with some modifications, associated with modified partial fixed prosthesis to achieve health in treated area. The modified techniques in both surgical and prosthetic procedures were applied to compensate the contraindications to recover biologic width by osteotomy in lower posterior teeth. The result, after 4 years under periodic control, seems to achieve the projected goal. Treating a dental diseased area is necessary to diagnose, eliminate, or control all etiologic factors involved in the process. When the traditional methods are not effective to recover destructed tissues, an alternative, compensatory, and adaptive procedure may be applied to restore the sequelae of the disease, applying a restorative method that respects the biology of involved tissues.


Assuntos
Aumento da Coroa Clínica/métodos , Prótese Parcial Fixa , Cárie Dentária/etiologia , Adaptação Marginal Dentária , Feminino , Gengiva/cirurgia , Humanos , Mandíbula , Pessoa de Meia-Idade , Osteotomia/métodos , Periodontite/etiologia
9.
J Prosthet Dent ; 105(4): 236-41, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21458648

RESUMO

STATEMENT OF PROBLEM: The color alteration of resin-based materials is one of the most common reasons to replace esthetic dental restorations. PURPOSE: This study assessed the influence of surface sealant (Biscover) on the color stability of nanofilled (Supreme XT) and microhybrid (Vit-l-escence and Opallis) composite resins after artificial aging. MATERIAL AND METHODS: One hundred disc-shaped (6 × 1.5 mm) specimens were made for each composite resin. After 24 hours, all specimens were polished and sealant was applied to 50 specimens of each material. Baseline color was measured according to the CIE L*a*b* system using a reflection spectrophotometer. Ten specimens of each group were aged for 252 h in an ultraviolet (UV)-accelerated aging chamber or immersed for 4 weeks in cola soft drink, orange juice, red wine staining solutions or distilled water as control. Color difference (ΔE) after aging was calculated based on the color coordinates before (baseline) and after aging/staining treatment. Data were analyzed with 2-way ANOVA and Fisher's test (α=.05). RESULTS: The results showed significant changes in color after artificial aging in all the groups (P<.05). Independent of the material studied, red wine resulted in the highest level of discoloration. Intermediate values were found for orange juice, UV accelerated aging, and the cola soft drink. The lowest values of ΔE were found for specimens stored in distilled water. CONCLUSIONS: All composite resins showed some color alteration after the aging methods. The surface sealant did not alter the color stability of the tested materials.


Assuntos
Acrilatos/efeitos da radiação , Resinas Compostas/efeitos da radiação , Restauração Dentária Permanente , Pigmentação em Prótese , Cimentos de Resina/efeitos da radiação , Descoloração de Dente/prevenção & controle , Análise de Variância , Teste de Materiais , Espectrofotometria , Raios Ultravioleta/efeitos adversos
10.
Compend Contin Educ Dent ; 32(7): E110-4, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23738993

RESUMO

Gastroesophageal reflux disease (GERD) is a gastrointestinal disorder in which stomach acids are chronically regurgitated into the esophagus and oral cavity. Continual exposure of the teeth to these acids can cause severe tooth wear. Dentists are often the first healthcare professionals to diagnose dental erosion in patients with GERD. This article presents a case report of a 27-year-old male smoker with tooth wear and dentin sensitivity caused by GERD associated with bruxism. After diagnosis, a multidisciplinary treatment plan was established. The initial treatment approach consisted of medical follow-up with counseling on dietary and smoking habits, as well as management of the gastric disorders with medication. GERD management and the dental treatment performed for the eroded dentition are described, including diagnosis, treatment planning, and restorative therapy.


Assuntos
Bruxismo/complicações , Restauração Dentária Permanente , Sensibilidade da Dentina/etiologia , Refluxo Gastroesofágico/complicações , Erosão Dentária/etiologia , Erosão Dentária/terapia , Adulto , Bruxismo/terapia , Terapia Combinada , Refluxo Gastroesofágico/terapia , Humanos , Masculino
11.
J Craniofac Surg ; 21(4): 1274-6, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20613612

RESUMO

Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory prosthodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.


Assuntos
Técnica de Moldagem Odontológica , Prótese Dentária Fixada por Implante , Modelos Dentários , Materiais para Moldagem Odontológica , Planejamento de Prótese Dentária , Humanos , Propriedades de Superfície
12.
J Craniofac Surg ; 20(4): 1173-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19568186

RESUMO

The application of engineering knowledge in dentistry has helped the understanding of biomechanics aspects related to osseointegrated implants. Several techniques have been used to evaluate the biomechanical load on implants comprising the use of photoelastic stress analysis, finite element stress analysis, and strain-gauge analysis. Therefore, the purpose of this study was to describe engineering methods used in dentistry to evaluate the biomechanical behavior of osseointegrated implants. Photoelasticity provides good qualitative information on the overall location and concentration of stresses but produces limited quantitative information. The method serves as an important tool for determining the critical stress points in a material and is often used for determining stress concentration factors in irregular geometries. The application of strain-gauge method on dental implants is based on the use of electrical resistance strain gauges and its associated equipment and provides both in vitro and vivo measurements strains under static and dynamic loads. However, strain-gauge method provides only the data regarding strain at the gauge. Finite element analysis can simulate stress using a computer-created model to calculate stress, strain, and displacement. Such analysis has the advantage of allowing several conditions to be changed easily and allows measurement of stress distribution around implants at optional points that are difficult to examine clinically. All the 3 methodologies can be useful to evaluate biomechanical implant behavior close to the clinical condition but the researcher should have enough knowledge in model fabrication (experimental delineation) and results analysis.


Assuntos
Engenharia Biomédica , Implantes Dentários , Análise do Estresse Dentário/métodos , Fenômenos Biomecânicos , Força Compressiva , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Elasticidade , Análise de Elementos Finitos , Humanos , Modelos Dentários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA