Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Water Sci Technol ; 88(8): 1927-1943, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37906450

RESUMO

In this paper, molybdenum disulfide was grown on the surface of iron-containing tailings by hydrothermal method, and a series of highly efficient activated persulfate (PMS) iron-based catalysts were successfully prepared. The results show that in the CTM 1-200/PMS system, the additional ratio of tailings and the hydrothermal temperature have important effects on the catalyst. The catalyst prepared under the conditions of CT:MoS2 (molar ratio 1:1) and hydrothermal temperature of 200 °C (CTM 1-200) had the best degradation effect on BPA, and the degradation effect was increased by four times. The reason for the improvement of degradation efficiency is that the introduction of MoS2 accelerates the REDOX cycle between Fe(II)/Fe(III), and the reduction of Fe(III) is mainly related to Mo(IV), while the reduction capacity of S is relatively weak. Molybdenum disulfide/iron tailing composite material provides a way for tailings to solve the problem of water pollution.


Assuntos
Ferro , Molibdênio , Compostos Férricos , Peróxidos
2.
Phys Imaging Radiat Oncol ; 26: 100438, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37342208

RESUMO

Background and Purpose: A recently developed biology-guided radiotherapy platform, equipped with positron emission tomography (PET) and computed tomography (CT), provides both anatomical and functional image guidance for radiotherapy. This study aimed to characterize performance of the kilovoltage CT (kVCT) system on this platform using standard quality metrics measured on phantom and patient images, using CT simulator images as reference. Materials and Methods: Image quality metrics, including spatial resolution/modular transfer function (MTF), slice sensitivity profile (SSP), noise performance and image uniformity, contrast-noise ratio (CNR) and low-contrast resolution, geometric accuracy, and CT number (HU) accuracy, were evaluated on phantom images. Patient images were evaluated mainly qualitatively. Results: On phantom images the MTF10% is about 0.68 lp/mm for kVCT in PET/CT Linac. The SSP agreed with nominal slice thickness within 0.7 mm. The diameter of the smallest visible target (1% contrast) is about 5 mm using medium dose mode. The image uniformity is within 2.0 HU. The geometric accuracy tests passed within 0.5 mm. Relative to CT simulator images, the noise is generally higher and the CNR is lower in PET/CT Linac kVCT images. The CT number accuracy is comparable between the two systems with maximum deviation from the phantom manufacturer range within 25 HU. On patient images, higher spatial resolution and image noise are observed on PET/CT Linac kVCT images. Conclusions: Major image quality metrics of the PET/CT Linac kVCT were within vendor-recommended tolerances. Better spatial resolution but higher noise and better/comparable low contrast visibility were observed as compared to a CT simulator when images were acquired with clinical protocols.

3.
J Vasc Interv Radiol ; 34(4): 544-555.e11, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36379286

RESUMO

PURPOSE: To update normative data on fluoroscopy dose indices in the United States for the first time since the Radiation Doses in Interventional Radiology study in the late 1990s. MATERIALS AND METHODS: The Dose Index Registry-Fluoroscopy pilot study collected data from March 2018 through December 2019, with 50 fluoroscopes from 10 sites submitting data. Primary radiation dose indices including fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA) were collected for interventional radiology fluoroscopically guided interventional (FGI) procedures. Clinical facility procedure names were mapped to the American College of Radiology (ACR) common procedure lexicon. Distribution parameters including the 10th, 25th, 50th, 75th, 95th, and 99th percentiles were computed. RESULTS: Dose indices were collected for 70,377 FGI procedures, with 50,501 ultimately eligible for analysis. Distribution parameters are reported for 100 ACR Common IDs. FT in minutes, Ka,r in mGy, and PKA in Gy-cm2 are reported in this study as (n; median) for select ACR Common IDs: inferior vena cava filter insertion (1,726; FT: 2.9; Ka,r: 55.8; PKA: 14.19); inferior vena cava filter removal (464; FT: 5.7; Ka,r: 178.6; PKA: 34.73); nephrostomy placement (2,037; FT: 4.1; Ka,r: 39.2; PKA: 6.61); percutaneous biliary drainage (952; FT: 12.4; Ka,r: 160.5; PKA: 21.32); gastrostomy placement (1,643; FT: 3.2; Ka,r: 29.1; PKA: 7.29); and transjugular intrahepatic portosystemic shunt placement (327; FT: 34.8; Ka,r: 813.0; PKA: 181.47). CONCLUSIONS: The ACR DIR-Fluoro pilot has provided state-of-the-practice statistics for radiation dose indices from IR FGI procedures. These data can be used to prioritize procedures for radiation optimization, as demonstrated in this work.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Doses de Radiação , Projetos Piloto , Fluoroscopia , Radiologia Intervencionista/métodos , Sistema de Registros , Radiografia Intervencionista/efeitos adversos
4.
J Vasc Interv Radiol ; 34(4): 556-562.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36031041

RESUMO

PURPOSE: To compare radiation dose index distributions for fluoroscopically guided interventions in interventional radiology from the American College of Radiology (ACR) Fluoroscopy Dose Index Registry (DIR-Fluoro) pilot to those from the Radiation Doses in Interventional Radiology (RAD-IR) study. MATERIALS AND METHODS: Individual and grouped ACR Common identification numbers (procedure types) from the DIR-Fluoro pilot were matched to procedure types in the RAD-IR study. Fifteen comparisons were made. Distribution parameters, including the 10th, 25th, 50th, 75th, and 95th percentiles, were compared for fluoroscopy time (FT), cumulative air kerma (Ka,r), and kerma area product (PKA). Two derived indices were computed using median dose indices. The procedure-averaged reference air kerma rate (Ka,r¯) was computed as Ka,r / FT. The procedure-averaged x-ray field size at the reference point (Ar) was computed as PKA / (Ka,r × 1,000). RESULTS: The median FT was equally likely to be higher or lower in the DIR-Fluoro pilot as it was in the RAD-IR study, whereas the maximum FT was almost twice as likely to be higher in the DIR-Fluoro pilot than it was in the RAD-IR study. The median Ka,r was lower in the DIR-Fluoro pilot for all procedures, as was median PKA. The maximum Ka,r and PKA were more often higher in the DIR-Fluoro pilot than in the RAD-IR study. Ka,r¯ followed the same pattern as Ka,r, whereas Ar was often greater in DIR-Fluoro. CONCLUSIONS: The median dose indices have decreased since the RAD-IR study. The typical Ka,r rates are lower, a result of the use of lower default dose rates. However, opportunities for quality improvement exist, including renewed focus on tight collimation of the imaging field of view.


Assuntos
Radiografia Intervencionista , Radiologia Intervencionista , Humanos , Radiologia Intervencionista/métodos , Doses de Radiação , Fluoroscopia , Radiografia Intervencionista/efeitos adversos , Sistema de Registros
5.
Materials (Basel) ; 15(12)2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35744293

RESUMO

In this study, ball mill pretreated iron ore tailings were modified with tetraethoxysilane (TEOS) and hexadecyltrimethoxysilane (HDTMS) to obtain iron ore tailings/polysiloxane (IOT/POS) superhydrophobic powders, which were subsequently mixed with chloroprene rubber solution (CRS) to prepare durable superhydrophobic composite coatings. The effect of HDTMS amount and reaction time on the wettability of the superhydrophobic powder was investigated. The influence of the superhydrophobic powders concentration on the wettability of the composite coatings as well as the degree of damage of the superhydrophobicity of the composite coating was analyzed by using the sandpaper abrasion and tape peeling tests. Further, SEM and FTIR were used to analyze the formation mechanism of the IOT/POS superhydrophobic powders and coatings. The results showed for an HDTMS amount of 2.5 mmol and reaction time of 4 h, the contact angle of the IOT/POS powder was 157.3 ± 0.6°, whereas the slide angle was determined to be 5.9 ± 0.8°. For an IOT/POS powder content of 0.06 g/mL in CRS, the contact angle value of the superhydrophobic composite coating was 159.2 ± 0.5°, whereas the slide angle value was 5.5 ± 0.8°. The superhydrophobic composite coating still maintained the superhydrophobicity after the sandpaper abrasion and tape peeling tests, which indicated the iron ore tailings solid waste has the potential to prepare superhydrophobic coatings.

6.
Water Sci Technol ; 85(8): 2332-2349, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35486458

RESUMO

In this work, iron was recovered from a kind of iron-rich pickling sludge by an acid leaching process, and the recycled iron was used as a catalyst to activate peroxydisulfate (PS) for the degradation of phenol. Different kinds of sludge catalysts were prepared by different drying methods such as ordinary drying (Ods), freeze drying (Fds) and vacuum drying (Vds). The degradation performance of the different catalysts/PS system under different conditions was explored, the vacuum drying sludge catalyst (Vds) has the best activity in a wide pH range (pH = 3-10) and a wide temperature range (0-40 °C). At the same time, the effect of a series of chelating agents (Oxalic acid (OA), Citric acid (CA), Tartaric acid (TA), Malic acid (DL-MA) and Ethylenediaminetetraacetic acid (EDTA)) on Vds/PS system was verified, and TA was selected as the best chelating agent to promote the degradation of the second stage where the degradation rate is limited. The quenching experiment and electron paramagnetic resonance (EPR) analysis indicated that hydroxyl radical (·OH) and sulfate radical (SO4̇-) were responsible for the abatement of the organic contaminant with ·OH playing a more important role. In summary, this study proposed an environmentally-friendly approach for the application of iron-rich pickling sludge in the remediation of phenol-contaminated water.


Assuntos
Fenol , Esgotos , Catálise , Quelantes , Radical Hidroxila , Ferro
7.
Materials (Basel) ; 15(5)2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35268987

RESUMO

In order to realize the high value-added resource utilization of solid waste and reduce the cost of rubber manufacturing, iron ore tailings (IOTs) were used as raw material to prepare a reinforcing filler of rubber through ultrafine grinding and surface organic modification techniques. We studied the effects of ball mill grinding conditions on the particle size and distribution of grinded iron ore tailings (G-IOTs). The effects of bis-(triethoxy-silyl-propyl)-tetrasulfide (Si69)-modified G-IOT (Si69-G-IOT) loading levels on the cure characteristics, static mechanical and dynamic mechanical properties of the styrene butadiene rubber (SBR) composites were also explored in this paper. The grinding and modification mechanism of IOTs and the combination of filler and SBR matrix were explored by grinding simulation of population balance model, X-ray diffraction analysis, Fourier transform infrared spectroscopy and scanning electron microscopy. The results showed that when grinding IOTs at 2000 r/min for 150 min, the particle size distribution of the resulting G-IOTs was the narrowest, with a D90 value of 4.42 µm. The tensile strength and elongation at break of SBR filled with 120 phr Si69-G-IOT were 14.97 MPa and 596.36%, respectively.

8.
Clin Nucl Med ; 46(1): 8-15, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33234926

RESUMO

PURPOSE: We assessed the prevalence of low bone mineral density (BMD) in oncologic patients undergoing F-FDG PET/CT. PATIENTS AND METHODS: This is a retrospective analysis of 100 patients who underwent F-FDG PET/CT at a single center from October 2015 till May 2016. Quantitative CT (QCT) was used to assess BMD at the lumbar spine (BMDQCT) and femoral necks (BMDCTXA). SUVmax was used to evaluate metabolic activity of the bone marrow. Risk of osteoporosis-related fractures was calculated with femoral neck BMDCTXA and the FRAX algorithm, which was compared against measurements of CT attenuation of the trabecular bone at L1 (L1HU). RESULTS: Osteoporosis and osteopenia were respectively present in 16% and 46% of patients 50 years and older. Bone marrow SUVmax was correlated with BMD at the lumbar spine (ρ = 0.36, P < 0.001). Increased age and low marrow SUVmax were associated with low BMDQCT at the lumbar spine (both P < 0.001), whereas increased age, female sex, and low marrow SUVmax were associated with low BMDCTXA at the femoral necks (P < 0.001, P < 0.001, P = 0.01, respectively). L1HU had an area under the curve of 0.95 (95% confidence interval [CI], 0.90-0.99) for detecting increased risk for osteoporosis-related fracture, with best threshold of 125.8 HU (95% CI, 115.7-144.9) yielding sensitivity of 100% (95% CI, 0.92-1.00), specificity of 0.90 (95% CI, 0.76-0.97), and accuracy of 0.91 (95% CI, 0.79-0.97). CONCLUSIONS: Low BMD is frequent in oncologic patients undergoing F-FDG PET/CT. Decreased F-FDG avidity of the bone marrow correlates with decreased BMD, validating the link between osteoporosis and bone marrow fat. L1HU could be a simple and accurate approach for detecting patients at risk for osteoporosis-related fractures using PET/CTdata.


Assuntos
Densidade Óssea , Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Neoplasias/fisiopatologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Feminino , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
Med Phys ; 48(2): 902-911, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33202055

RESUMO

PURPOSE: To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. ACQUISITION AND VALIDATION METHODS: The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low-dose noncontrast chest scans acquired to screen high-risk patients for pulmonary nodules, and contrast-enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise-insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. DATA FORMAT AND USAGE NOTES: Projection datasets were converted into the previously developed DICOM-CT-PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM-CT-PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive (https://doi.org/10.7937/9npb-2637). POTENTIAL APPLICATIONS: This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task-based diagnostic performance.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Tórax , Tomógrafos Computadorizados
10.
J Ethnopharmacol ; 254: 112713, 2020 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-32109545

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Zoujin pill (ZJP), a medication used to treat gastrointestinal disorders since the 15th Century in China, have been reported to exert anti-depressant effects in various models. STUDY AIM: To assess the effects of ZJP on gastrointestinal function and depressive behavior in rats under chronic unpredictable mild stress (CUMS), and to examine the underlying mechanisms related to brain-gut axis. METHODS: The rats suffered the stressor once daily for 5 weeks. ZJP (0.6 and 1.2 g/kg) and fluoxetine (15 mg/kg) as positive control were administered to the rats through gastric intubation once daily for 5 consecutive weeks. The anti-depression effects were compared by performing sucrose preference tests and open field tests. Gastrointestinal motility was investigated by determining the gastrointestinal transit rate and by electrogastrogram. The serum levels of the gastrointestinal hormone (GAS, MOT, VIP, SP), inflammatory cytokine (IL-1ß, IL-6; , TNFα) and glucagon-like peptide-1 (GLP-1) were assayed by enzyme-linked immunosorbent assay. For monoamine neurotransmitters (NE, 5-HT, DA), the levels were determined by high-performance liquid chromatography and electrochemical detection in conjunction, which was applied on the samples taken from the hypothalamus, hippocampus, and striatum. RESULTS: The depression-like symptoms among rats under CUMS were significantly relieved by ZJP administration (0.6 and 1.2 g/kg). Gastrointestinal motility was also improved by restoring gastric electrical rhythm and promoting gastrointestinal propulsion. The ZJP at 0.6 g/kg dosage obviously up-regulated 5-HT and DA levels in hippocampus. The ZJP at 1.2 g/kg dosage could increase 5-HT and DA levels in hypothalamus, striatum, and hippocampus, while down-regulated the NE level in hypothalamus and hippocampus. ZJP also reversed the alterations in serum gastrointestinal hormones. Furthermore, treatment with ZJP significantly reduced levels of IL-1ß, IL-6 and TNF-α and increased serum GLP-1 compared with the CUMS group. Fluoxetine also exerted similar anti-depressant effects in the absence of effects on gastrointestinal motility and the levels of serum hormone, inflammatory cytokine and GLP-1. CONCLUSION: ZJP imposed anti-depressant and gastrointestinal regulating functions in rats under CUMS, suggesting potential clinical application. .


Assuntos
Antidepressivos/uso terapêutico , Depressão/tratamento farmacológico , Medicamentos de Ervas Chinesas/uso terapêutico , Intestino Delgado/efeitos dos fármacos , Estresse Psicológico/tratamento farmacológico , Animais , Antidepressivos/farmacologia , Comportamento Animal/efeitos dos fármacos , Monoaminas Biogênicas/metabolismo , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Doença Crônica , Citocinas/sangue , Depressão/sangue , Depressão/fisiopatologia , Medicamentos de Ervas Chinesas/farmacologia , Gastrinas/sangue , Trânsito Gastrointestinal/efeitos dos fármacos , Peptídeo 1 Semelhante ao Glucagon/sangue , Intestino Delgado/fisiologia , Masculino , Motilina/sangue , Ratos Sprague-Dawley , Estresse Psicológico/sangue , Estresse Psicológico/fisiopatologia , Substância P/sangue , Peptídeo Intestinal Vasoativo/sangue
11.
Abdom Radiol (NY) ; 45(10): 3361-3368, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31587100

RESUMO

PURPOSE: To compare radiation dose and image quality for abdominal CTs performed on a spectral detector CT (SDCT) and a comparable single-energy conventional CT scanner for patients of different sizes. METHODS: Four semi-anthropomorphic phantoms were scanned on an SDCT (IQon, Philips Healthcare) and a comparable single-energy CT (iCT 256, Philips Healthcare) under matched scan parameters. Image noise and radiation dose were compared. For the HIPAA-compliant, IRB-approved retrospective cohort patient study, radiation dose was compared after adjusting for patient water equivalent diameter. Difference in subjective and objective image quality was assessed on a subset of 50 patients scanned on both scanners by two readers. RESULTS: CTDIvol and noise from SDCT were higher than conventional CT for all phantoms, with a relative difference of 7.8% (range 5.3-14%) for radiation dose and average difference of 9.0% (range 5.5-11%) for noise. 718 SDCT and 937 conventional CT patients were included in the patient study. CTDIvol for SDCT patients tends to be lower for smaller patients (- 2%, 95% confidence interval (- 5%, - 0.2%) for 200 mm water equivalent diameter) and higher for larger patients compared to conventional CT (8%, (6%, 11%) for 400 mm). No difference was seen for subjective image quality, SNR, CNR, or image noise between the two scanners, except for higher image noise in the portal vein and higher signal in the aorta on SDCT. CONCLUSION: Radiation dose for abdominal CT performed on SDCT is similar to the dose on a conventional CT for average size patients, lower for smaller patients, and slightly higher for larger patients. Image quality is similar between the two scanners.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído
12.
Phys Med Biol ; 64(19): 195015, 2019 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-31437824

RESUMO

The dual-energy computed tomography (DECT)-based approach holds promise in reducing the overall uncertainty in proton stopping-power-ratio (SPR) estimation, but cannot be easily implemented with most commercial proton treatment planning systems (TPS). In this study, we revisited the idea of coupling the stoichiometric calibration method with virtual monoenergetic CT datasets (MonoCT) generated by modern DECT scanners, because of its readiness for implementation with the existing TPS. Our objective was to determine the optimal energy of the MonoCT dataset for stoichiometric calibration and estimate the overall uncertainty in SPR estimation at the optimal energy. We performed stoichiometric calibration for MonoCT datasets across the energy range available on a Siemens Force DECT scanner and a Philips IQon DECT scanner in a 10 keV step. We estimated the uncertainties of different sources (imaging, modeling, and inherent uncertainties) for different tissue types (lung, soft, and bone tissues) associated with each energy; these were then combined into a single composite uncertainty for three tumor sites (head-and-neck (HN), lung, and prostate). The optimal energy was eventually selected based on the composite range uncertainty, which turned out to be 160 keV for both DECT scanners. At 160 keV, the total uncertainties (2σ) in SPR estimation were determined to be 3.2%-4.5%, 0.9%, and 1.4%-1.6% for lung, soft, and bony tissues, respectively. These results were comparable to the corresponding values estimated for the DECT approach evaluated in our previous study: 3.8%, 1.2% and 2.0%, for lung, soft, and bony tissues, respectively. The composite range uncertainties (2σ) were estimated as 1.5%, 1.7%, and 1.5% for prostate, lung, and HN, respectively. Our results demonstrated the potential of MonoCT images for reducing proton SPR uncertainty. Further clinical studies are needed to compare this approach with the DECT approach directly on real patient cases.


Assuntos
Osso e Ossos/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Prótons , Tomografia Computadorizada por Raios X , Algoritmos , Calibragem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Incerteza
13.
Med Phys ; 46(5): 2251-2263, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30883827

RESUMO

PURPOSE: Dual-energy CT (DECT) has been shown to have a great potential in reducing the uncertainty in proton stopping power ratio (SPR) estimation, when compared to current standard method - the stoichiometric method based on single-energy CT (SECT). However, a few recent studies indicated that imaging noise may have a substantial impact on the performance of the DECT-based approach, especially at a high noise level. The goal of this study is to quantify the uncertainty in SPR and range estimation caused by noise in the DECT-based approach under various conditions. METHODS: Two widely referred parametric DECT methods were studied: the Hünemohr-Saito (HS) method and the Bourque method. Both methods were calibrated using Gammex tissue substitute inserts scanned on the Siemens Force DECT scanner. An energy pair of 80 and 150 kVp with a tin filter was chosen to maximize the spectral separation. After calibrating the model with the Gammex phantom, CT numbers were synthesized using the density and elemental composition from ICRU 44 human tissues to be used as a reference, in order to evaluate the impact of noise alone while putting aside other sources of uncertainty. Gaussian noise was introduced to the reference CT numbers and its impact was measured with the difference between estimated SPR and its noiseless reference SPR. The uncertainty caused by noise was divided into two independent categories: shift of the mean SPR and variation of SPR. Their overall impact on range uncertainty was evaluated on homogeneous and heterogeneous tissue samples of various water equivalent path lengths (WEPL). RESULTS: Due to the algorithms being nonlinear and/or having hard thresholds in the CT number to SPR mapping, noise in the CT numbers induced a shift in the mean SPR from its noiseless reference SPR. The degree of the mean shift was dependent on the algorithm and tissue type, but its impact on the SPR uncertainty was mostly small compared to the variation. All mean shifts observed in this study were within 0.5% at a noise level of 2%. The ratio of the influence of variation to mean shift was mostly greater than 1, indicating that variation more likely determined the uncertainty caused by noise. Overall, the range uncertainty (95th percentile) caused by noise was within 1.2% and 1.0% for soft and bone tissues, respectively, at 2% noise with 50 voxels. This value can be considered an upper limit as more voxels and lower noise level rapidly decreased the uncertainty. CONCLUSIONS: We have systematically evaluated the impact of noise to the DECT-based SPR estimation and identified under various conditions that the variation caused by noise is the dominant uncertainty-contributing component. We conclude that, based on the noise level and tumor depth, it is important to estimate and include the uncertainty due to noise in estimating the overall range uncertainty before implementing a small margin in the range of 1%.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Prótons , Razão Sinal-Ruído , Distribuição Normal , Tomografia Computadorizada por Raios X , Incerteza
14.
Eur J Radiol ; 105: 125-133, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30017268

RESUMO

PURPOSE: To measure the effect of pseudoenhancement on spectral CT iodine quantification as a function of lesion size, lesion iodine level, background iodine level, helical versus axial scanning, and spectral CT scanner type in a phantom model. MATERIALS AND METHODS: A custom-built water-filled cylindrical phantom contained either six small vials (8 mm diameter) or six large vials (27 mm diameter) of aqueous iopamidol solutions (0, 0.5, 1.0, 2.0, 4.0 and 6.0 mg iodine/mL). The background iodine concentration was 0, 5, or 10 mg iodine/mL. Helical and axial scans were taken on three different dual-energy spectral CT scanners (two image-based and one projection-based) with the scan parameters consistent between the systems. ROIs were used to measure the average iodine concentration of the vials in the 36 individual scans. Linear fits of the true versus measured iodine values were used for pvalue statistical analysis. Having a y-intercept or slope p-value less than 0.05 implied statistically significant iodine quantification errors. RESULTS: Iodine quantification pseudoenhancement effects are inversely proportional to lesion size and lesion enhancement and are directly proportional to background attenuation level. No significant differences between helical and axial scans were observed. 100% and 88% of the slope and y-intercept p-values were below 0.05 for the two image-based systems, while 13% of the slope and y-intercept p-values were below 0.05 for the projection-based system. CONCLUSIONS: Pseudoenhancement can artificially increase spectral CT iodine quantification levels most notably for small low-enhancing lesions (<5.0 mg iodine/mL) surrounded by a high attenuating background (10 mg iodine/mL). In this study we found iodine quantification to be more accurate on projection-based spectral CT systems than image-based systems.


Assuntos
Meios de Contraste , Iodo , Doenças Renais Císticas/diagnóstico por imagem , Relação Dose-Resposta a Droga , Desenho de Equipamento , Humanos , Iopamidol , Rim/diagnóstico por imagem , Modelos Teóricos , Imagens de Fantasmas , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Água
15.
Phys Med Biol ; 63(11): 115007, 2018 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-29722297

RESUMO

Four-dimensional (4D) x-ray cone-beam computed tomography (CBCT) is important for a precise radiation therapy for lung cancer. Due to the repeated use and 4D acquisition over a course of radiotherapy, the radiation dose becomes a concern. Meanwhile, the scatter contamination in CBCT deteriorates image quality for treatment tasks. In this work, we propose the use of a moving blocker (MB) during the 4D CBCT acquisition ('4D MB') and to combine motion-compensated reconstruction to address these two issues simultaneously. In 4D MB CBCT, the moving blocker reduces the x-ray flux passing through the patient and collects the scatter information in the blocked region at the same time. The scatter signal is estimated from the blocked region for correction. Even though the number of projection views and projection data in each view are not complete for conventional reconstruction, 4D reconstruction with a total-variation (TV) constraint and a motion-compensated temporal constraint can utilize both spatial gradient sparsity and temporal correlations among different phases to overcome the missing data problem. The feasibility simulation studies using the 4D NCAT phantom showed that 4D MB with motion-compensated reconstruction with 1/3 imaging dose reduction could produce satisfactory images and achieve 37% improvement on structural similarity (SSIM) index and 55% improvement on root mean square error (RMSE), compared to 4D reconstruction at the regular imaging dose without scatter correction. For the same 4D MB data, 4D reconstruction outperformed 3D TV reconstruction by 28% on SSIM and 34% on RMSE. A study of synthetic patient data also demonstrated the potential of 4D MB to reduce the radiation dose by 1/3 without compromising the image quality. This work paves the way for more comprehensive studies to investigate the dose reduction limit offered by this novel 4D MB method using physical phantom experiments and real patient data based on clinical relevant metrics.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Doses de Radiação , Espalhamento de Radiação
16.
Abdom Radiol (NY) ; 43(11): 3075-3081, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29626256

RESUMO

PURPOSE: To assess the non-inferiority of dual-layer spectral detector CT (SDCT) compared to dual-source dual-energy CT (dsDECT) in discriminating uric acid (UA) from non-UA stones. METHODS: Fifty-seven extracted urinary calculi were placed in a cylindrical phantom in a water bath and scanned on a SDCT scanner (IQon, Philips Healthcare) and second- and third-generation dsDECT scanners (Somatom Flash and Force, Siemens Healthcare) under matched scan parameters. For SDCT data, conventional images and virtual monoenergetic reconstructions were created. A customized 3D growing region segmentation tool was used to segment each stone on a pixel-by-pixel basis for statistical analysis. Median virtual monoenergetic ratios (VMRs) of 40/200, 62/92, and 62/100 for each stone were recorded. For dsDECT data, dual-energy ratio (DER) for each stone was recorded from vendor-specific postprocessing software (Syngo Via) using the Kidney Stones Application. The clinical reference standard of X-ray diffraction analysis was used to assess non-inferiority. Area under the receiver-operating characteristic curve (AUC) was used to assess diagnostic performance of detecting UA stones. RESULTS: Six pure UA, 47 pure calcium-based, 1 pure cystine, and 3 mixed struvite stones were scanned. All pure UA stones were correctly separated from non-UA stones using SDCT and dsDECT (AUC = 1). For UA stones, median VMR was 0.95-0.99 and DER 1.00-1.02. For non-UA stones, median VMR was 1.4-4.1 and DER 1.39-1.69. CONCLUSION: SDCT spectral reconstructions demonstrate similar performance to those of dsDECT in discriminating UA from non-UA stones in a phantom model.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/análise , Cálculos Urinários/química , Cálculos Urinários/diagnóstico por imagem , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Difração de Raios X
17.
AJR Am J Roentgenol ; 205(2): W172-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26204304

RESUMO

OBJECTIVE: The purpose of this article is to assess the effect of radiation dose reduction in dual-energy CT (DECT) on the performance of renal stone characterization using a patient cohort. MATERIALS AND METHODS: CT data from 39 unenhanced DECT examinations performed for stone characterization were retrospectively analyzed in this study. Reduced-dose images were simulated at 75%, 50%, and 25% of the routine dose using a previously validated noise-insertion algorithm. Differentiation between uric acid (UA) and non-UA stones was performed using a fixed cutoff value for the dual-energy ratio. ROC analysis was performed to determine optimal cutoff values and the associated sensitivity and specificity. RESULTS: Of the 206 stones found, 43 were UA and 163 were non-UA. The mean (± SD) volume CT dose index (CTDIvol) was 16.0 ± 4.0 mGy at the 100% dose level. The mean noise in 100-kV images increased from 40.9 ± 6.8 HU at 100% dose to 46.8 ± 8.8 HU, 57.7 ± 12.5 HU, and 85.4 ± 22.9 HU at 75%, 50%, and 25% dose levels, respectively. Using the default cutoff value, for stones 10 mm(3) or larger, the sensitivity/specificity were 100.0%/98.8%, 82.8%/98.8%, and 89.3%/98.7%, at 75%, 50%, and 25% dose levels, respectively. ROC analysis showed varying optimal cutoff values at different dose levels. The sensitivity and specificity improved with use of these optimal cutoff values. Differentiation capability decreased for stones smaller than 10 mm(3). CONCLUSION: At 75% of the 16-mGy routine dose, the sensitivity and specificity for differentiating UA from non-UA stones were minimally affected for stones 10 mm(3) or larger. The use of optimal cutoff values for dual-energy ratio as dose decreased (and noise increased) provided improved performance.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X , Cálculos Urinários/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Ácido Úrico/química
18.
J Comput Assist Tomogr ; 38(3): 398-403, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24651744

RESUMO

OBJECTIVE: To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). METHODS: Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. RESULTS: For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P < 0.001), image noise was significantly lower (both P < 0.001), whereas volume CT dose index was unchanged (both P > 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. CONCLUSION: Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.


Assuntos
Artefatos , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/instrumentação , Neoplasias Colorretais/diagnóstico por imagem , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Transdutores , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Razão Sinal-Ruído
19.
Semin Respir Crit Care Med ; 35(1): 83-90, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24481762

RESUMO

Chest computed tomography (CT) is a useful tool for diagnosing various thoracic conditions and has become the diagnostic imaging modality of choice for many diseases. Recent discussions about the radiation dose from CT have attracted the attention of medical professionals and the general public. This article discusses radiation dose with an emphasis on chest CT and on current techniques for patient dose reduction. Four techniques are discussed in detail, including tube current modulation, automatic exposure control, automatic tube voltage selection, and iterative image reconstruction. Adopting these techniques in routine clinical practice can dramatically reduce radiation dose levels.


Assuntos
Neoplasias Induzidas por Radiação/prevenção & controle , Doenças Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação , Comportamento de Redução do Risco , Tomografia Computadorizada por Raios X/efeitos adversos
20.
Eur Radiol ; 23(5): 1408-14, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23263603

RESUMO

OBJECTIVE: To evaluate the ability of 100/Sn140 kV (Sn, tin filter) dual-energy computed tomography (CT) to differentiate urinary stone types in a patient cohort with a wide range of body sizes. METHODS: Eighty human urinary stones were categorised into four groups (uric acid; cystine; struvite, oxalate and brushite together; and apatite) and imaged in 30-50-cm-wide water tanks using clinical 100/Sn140 kV protocols. The CT number ratio (CTR) between the low- and high-energy images was calculated. Thresholds for differentiating between stone groups were determined using receiver operating characteristics (ROC) analysis. Additionally, 86 stones from 66 patients were characterised using the size-adaptive CTR thresholds determined in the phantom study. RESULTS: In phantoms, the area under the ROC curve for differentiating between stone groups ranged from 0.71 to 1.00, depending on phantom size. In patients, body width ranged from 28.5 to 50.0 cm, and 79.1 % of stones were correctly characterised. Sensitivity and specificity for correctly identifying the stone category were 100 % and 100 % (group 1), 100 % and 95.3 % (group 2), 85.7 % and 60.9 % (group 3), and 52.6 % and 92.5 % (group 4). CONCLUSION: Dual-energy CT can provide in vivo urinary stone characterisation for patients over a wide range of body sizes. KEY POINTS: • Dual-energy CT helps assessment of urinary stone composition in vivo. • 100/Sn140 kV DECT differentiates among four stone types with 79.1 % accuracy. • In vivo diagnostic test achievable in patients with many body sizes.


Assuntos
Tamanho Corporal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Cálculos Urinários/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA