Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Struct Heart ; 7(4): 100179, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520135

RESUMO

Background: The long-term outcomes of patients undergoing functional assessment of coronary lesions with fractional flow reserve (FFR) while awaiting transcatheter aortic valve implantation (TAVI) are unknown. Data on the safety of intracoronary adenosine use in this setting are scarce. The objectives of this study were to describe (1) the long-term outcomes based on the coronary artery disease (CAD) assessment strategy used and (2) the safety of intracoronary adenosine in patients with severe aortic stenosis (AS). Methods: 1023 patients with severe AS awaiting TAVI were included. Patients were classified according to their CAD assessment strategy: angiography guided or FFR guided. Patients were further subdivided according to the decision to proceed with percutaneous coronary intervention (PCI): angiography-guided PCI (375/1023), angiography-guided no-PCI (549/1023), FFR-guided PCI (50/1023), and FFR-guided no-PCI (49/1023). Patients were followed up for the occurrence of major adverse cardiac and cerebrovascular events (MACCEs). Results: At a mean follow-up of 33.7 months, we observed no significant differences in terms of major adverse cardiovascular and cerebrovascular events (MACCE) in the angiography-guided group (42.4%) compared with the FFR-guided group (37.4%) (p = 0.333). When comparing outcomes of the FFR-guided no-PCI group (32.7%) with the angiography-guided PCI group (46.4%), no significant difference was noted (p = 0.999). Following intracoronary adenosine, a single adverse event occurred. Conclusions: In this population, intracoronary adenosine is safe and well tolerated. We found no significant benefit to an FFR-guided strategy compared with an angiography-guided strategy with respect to MACCEs. Although clinically compelling, avoiding the procedural risks of PCI by deferring the intervention in functionally insignificant lesions failed to show a statistically significant benefit.

2.
Pacing Clin Electrophysiol ; 46(7): 639-644, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37196145

RESUMO

INTRODUCTION: Superior vena cava (SVC) tear is the most lethal complication during transvenous lead extraction (TLE) with a mortality rate as high as 50%. Treatment involves aggressive attempts to maintain cardiac output and immediate sternotomy to localize and repair the vascular tear. Occlusion balloons have been developed to provisionally occlude the lacerated SVC and to provide hemodynamic stability allowing time for surgery. In case of mediastinal hematoma without hemodynamic instability, the strategy remains unclear. METHODS AND RESULTS: We describe two cases of SVC tear during TLE. The first case was a 60-year-old man who presented with a right ventricular single-chamber defibrillator lead fracture and innominate vein stenosis. The RV lead was removed using a laser sheath causing a mediastinal hematoma with no active bleeding during surgical exploration few hours later. The second case was a 28-year-old man that presented with a right atrial (RA) lead fracture and RV lead insulation failure in a dual-chamber defibrillator (ICD). CONCLUSION: Both the RA and RV leads were removed with mechanical sheaths, and a mediastinal hematoma was medically managed.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Veia Cava Superior/cirurgia , Marca-Passo Artificial/efeitos adversos , Átrios do Coração/cirurgia , Hematoma , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos
3.
J Thorac Cardiovasc Surg ; 165(3): 1010-1019.e5, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-33840473

RESUMO

OBJECTIVES: The effectiveness of a multidisciplinary heart team in the management of patients with severe symptomatic aortic stenosis is unknown. This study evaluated the impact of a heart team on the outcomes of surgical aortic valve replacement in octogenarians. METHODS: Between May 2007 and January 2016, 528 patients aged 80 years or more were referred to our institutional heart team for a transcatheter aortic valve replacement. Among these, 101 were redirected to surgical aortic valve replacement (heart team group). These patients were compared with a surgical aortic valve replacement cohort (n = 506) without prior heart team screening (non-heart team group), taken from the same time period. Propensity score matching with bootstrap analysis was performed; 76 heart team patients were matched to 76 non-heart team patients. Early and late outcomes including survival and readmission for cardiovascular causes were compared. RESULTS: Matched subgroups were largely comparable; congestive heart failure and echocardiographic pulmonary hypertension were more prevalent in the heart team group. In-hospital mortality was significantly lower in the matched heart team group (0% vs 6.0%, bootstrap mean difference 6.0%, 95% confidence interval, 2.2-9.8). The risk of stroke, low cardiac output state, reexploration for bleeding, pneumonia, and prolonged ventilation was also significantly lower in the heart team group. There was no significant between-group difference regarding late survival (hazard ratio, 0.86, 95% confidence interval, 0.55-1.33, P = .49) or readmission for cardiovascular reasons (hazard ratio, 0.70, 95% confidence interval, 0.41-1.20, P = .19). CONCLUSIONS: Preoperative multidisciplinary assessment of octogenarians by a heart team was associated with lower in-hospital mortality and adverse events after surgical aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Octogenários , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco
5.
Semin Thorac Cardiovasc Surg ; 35(3): 457-464, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35430352

RESUMO

Aortic pseudoaneurysms after acute Type A aortic dissection (ATAAD) repair have been reported as high as 10-24% and surgical treatment is usually recommended. The objective of this article is to examine the safety and efficacy of a conservative approach to aortic pseudoaneurysm and to compare this approach to standard surgical treatment. We retrospectively examined 39 patients who had an aortic pseudoaneurysm after ATAAD surgery in order to examine outcomes (baseline characteristics, presentation and freedom from aortic events and mortality). We initially identified 31 patients treated conservatively (CT). After close follow up, 5 of them were operated so 13 patients were treated surgically (ST) and analyzed at a long-term follow-up while 26 were in the conservative group. Mean follow- - up of the whole cohort was 7.9 ± 5.9 years. The freedom from aortic-related mortality at 1, 5, and 10 years was 100%, 83.3% and 72.9% for the ST group and 95.8%, 77.3%, and 77.3% for the CT group (P = 0.35). A conservative approach to aortic pseudoaneurysms could be justified in asymptomatic patients. A close follow-up by a dedicated aortic clinic is mandatory so that patients are referred for surgery when necessary.

6.
J Card Surg ; 37(10): 3178-3187, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35870159

RESUMO

OBJECTIVES: With the extended indications of transcatheter aortic valve (TAV) replacement (TAVR) to lower-risk patients, there is an increasing number of patients requiring surgical explantation of failed TAV. We sought to describe macroscopic and microscopic features of surgically explanted percutaneous aortic valve prostheses. METHODS: Preoperative and surgical characteristic of patients undergoing surgical explantation of TAV were retrospectively analyzed from 2007 to 2020. Surgical and pathologic features of these valves, and outcomes of the surgical valve replacement were described. RESULTS: Out of 1764 patients who underwent a TAVR procedure, 21 were operated for TAV failure. Isolated or combined indications for surgery included: significant paravalvular leak (n = 15), delayed prosthesis migration (n = 5), significant increase of trans-TAV gradients (n = 6), and endocarditis (n = 3). Mean time elapsed between TAVR and explantations was 674.9 ± 803.9 days. Macroscopic lesions found on explanted percutaneous valves were severe adhesions to the aorta (n = 10), calcifications (n = 7), leaflet thrombosis (n = 4), and vegetations (n = 3). Except for patients with endocarditis, one or more pathological lesions were found in 15 patients. Pathology analyses on these valves showed fibro-calcific degenerations (n = 12), pannus formation (n = 9), and chronic inflammation (n = 3). One patient (4.8%) died after surgical explantation, and 13 (61.9%) had concomitant procedures. The survival rate at 1 year was 94.4%. CONCLUSIONS: Microscopic findings of fibro-calcific leaflet degeneration, and pannus formation in addition to macroscopic calcification and thrombosis present early, (within a mean of 2 years) after TAVR. Further investigation with a higher number of patients and echocardiographic follow-up is warranted.


Assuntos
Estenose da Valva Aórtica , Calcinose , Endocardite , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Calcinose/patologia , Endocardite/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35639725

RESUMO

OBJECTIVES: Sutureless aortic valve replacement (SU-SAVR) has been associated with higher rates of permanent pacemaker (PPM) compared with conventionally implanted aortic bioprostheses. The purpose of this study was to determine the incidence, predictors and mid-term prognostic impact of PPM after Perceval (Livanova, London, UK) SU-SAVR in low-risk patients. METHODS: A total of 400 consecutive low-risk (EuroSCORE II < 4%) patients without prior pacemaker who underwent surgical aortic valve replacement with the Perceval prosthesis from 2013 to 2019 in 2 centres were included. Baseline, clinical and electrocardiographic parameters, procedural characteristics and follow-up data were collected. RESULTS: PPM was required in 36 (9%) patients after SU-SAVR, with a median time between the procedure and PPM implantation of 7.5 (4.5-10.5) days. Older age and prior right bundle branch block (RBBB) were associated with an increased risk of PPM (P < 0.05 for all), but only baseline RBBB was found to be an independent predictor of new PPM requirement (odds ratio: 2.60, 95% confidence interval: 1.15-5.81; P = 0.022). At a median follow-up of 3.4 (2.3-4.5) years, there were no differences between groups in mortality (PPM: 36%, no PPM: 22%, P = 0.105) or heart failure rehospitalization (PPM: 25%, no PPM: 21%, P = 0.839). CONCLUSIONS: About 1 out of 10 low-risk patients with aortic stenosis undergoing SU-SAVR with the Perceval prosthesis required PPM implantation. Prior RBBB determined an increased risk (close to 3-fold) of PPM following the procedure. PPM was not associated with a higher risk of clinical events at 3-year follow-up.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Bloqueio de Ramo/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Prognóstico , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Struct Heart ; 6(6): 100106, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37288124

RESUMO

Background: Transcatheter valve-in-valve replacement (ViV-TAVR) has emerged as an alternative to redo-surgical aortic valve replacement (Redo-SAVR) for the treatment of failed surgical aortic bioprostheses. However, the benefit of ViV-TAVR compared with Redo-SAVR remains debated with regard to short-term hemodynamic results and short- and long-term clinical outcomes. Objective: This study aimed to compare short-term hemodynamic performance and long-term clinical outcomes of ViV-TAVR vs. Redo-SAVR in patients treated for surgical aortic bioprosthetic valve failure. Methods: We retrospectively analyzed the data prospectively collected in 184 patients who underwent Redo-SAVR or ViV-TAVR. Transthoracic echocardiography was performed before and after the procedure and analyzed in an echocardiography core laboratory using the new Valve Academic Research Consortium-3 criteria. An inverse probability of treatment weighting was used to compare the outcomes between both procedures. Results: ViV-TAVR showed lower rate of intended hemodynamic performance (39.2% vs. 67.7%, p < 0.001) at 30 days, which was essentially driven by a higher rate (56.2% vs. 28.8%, p = 0.001) of high residual gradient (mean transvalvular gradient ≥20 mm Hg). Despite a trend for higher 30-day mortality in the Redo-SAVR vs. ViV-TAVR group (8.7% vs. 2.5%, odds ratio [95% CI]: 3.70 [0.77-17.6]; p = 0.10), the long-term mortality was significantly lower (24.2% vs. 50.1% at 8 years; hazard ratio [95% CI]: 0.48 [0.26-0.91]; p = 0.03) in the Redo-SAVR group. After inverse probability of treatment weighting analysis, Redo-SAVR remained significantly associated with reduced long-term mortality compared with ViV-TAVR (hazard ratio [95% CI]: 0.32 [0.22-0.46]; p < 0.001). Conclusions: ViV-TAVR was associated with a lower rate of intended hemodynamic performance and numerically lower mortality at 30 days but higher rates of long-term mortality compared with Redo-SAVR.

9.
J Thorac Cardiovasc Surg ; 163(1): 69-77, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32387164

RESUMO

OBJECTIVES: The femoral artery is the preferred vascular access to perform transcatheter aortic valve replacement (TAVR). However, the optimal alternative approach has not been elucidated in patients who are not candidates for a transfemoral (TF) access. The objective of this study was to compare the outcomes of TAVR performed by the transcarotid (TC) compared with the TF approach. METHODS: This was a single-center study that included 526 consecutive patients who underwent TAVR between 2015 and 2019. TC-TAVR was performed in 127 and TF-TAVR in 399 patients. Postprocedural and 30-day clinical events were evaluated according to main access (TC vs TF) using a multivariate logistic regression model. One-year survival and freedom from neurological events were also evaluated. RESULTS: The prevalence of diabetes, chronic obstructive pulmonary disease, coronary artery disease, and peripheral vascular disease was higher in the TC group. In-hospital mortality (3.2% vs 2.0%, adjusted odds ratio, 1.83; 95% confidence interval, 0.47-7.15; P = .39), and 30-day stroke (2.4% vs 3.3%; odds ratio, 0.84; 95% confidence interval, 0.21-3.41; P = .81), were similar between groups as were other outcomes: procedural success (98.4% vs 97.0%; P = .52), 30-day cumulative mortality (4.8% vs 2.8%; P = .26), major vascular complication (2.4% vs 4.5%; P = .25), and major/life-threatening bleeding (4.7% vs 6.0%; P = .41) (TC vs TF, respectively). No differences were found among groups regarding survival or neurological events at 1-year follow-up. CONCLUSIONS: The TC approach is a safe alternate-access strategy for TAVR, and is associated with similar outcomes compared with TF-TAVR, despite a higher disease burden in TC patients.


Assuntos
Estenose da Valva Aórtica , Artérias Carótidas/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral/cirurgia , Hemorragia , Complicações Pós-Operatórias , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Canadá/epidemiologia , Feminino , Hemorragia/diagnóstico , Hemorragia/epidemiologia , Hemorragia/etiologia , Mortalidade Hospitalar , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Risco Ajustado/métodos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
10.
JACC Cardiovasc Interv ; 14(22): 2490-2499, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34794656

RESUMO

OBJECTIVES: The aim of this study was to compare, in a cohort of patients with complex coronary artery disease (CAD) and severe aortic stenosis (AS), the clinical outcomes associated with transfemoral transcatheter aortic valve replacement (TAVR) (plus percutaneous coronary intervention [PCI]) versus surgical aortic valve replacement (SAVR) (plus coronary artery bypass grafting [CABG]). BACKGROUND: Patients with complex CAD were excluded from the main randomized trials comparing TAVR with SAVR, and no data exist comparing TAVR + PCI vs SAVR + CABG in such patients. METHODS: A multicenter study was conducted including consecutive patients with severe AS and complex CAD (SYNTAX [Synergy Between PCI with Taxus and Cardiac Surgery] score >22 or unprotected left main disease). A 1:1 propensity-matched analysis was performed to account for unbalanced covariates. The rates of major adverse cardiac and cerebrovascular events (MACCE), including all-cause mortality, nonprocedural myocardial infarction, need for new coronary revascularization, and stroke, were evaluated. RESULTS: A total of 800 patients (598 undergoing SAVR + CABG and 202 undergoing transfemoral TAVR + PCI) were included, and after propensity matching, a total of 156 pairs of patients were generated. After a median follow-up period of 3 years (interquartile range: 1-6 years), there were no significant differences between groups for MACCE (HR for transfemoral TAVR vs SAVR: 1.33; 95% CI: 0.89-1.98), all-cause mortality (HR: 1.25; 95% CI: 0.81-1.94), myocardial infarction (HR: 1.16; 95% CI: 0.41-3.27), and stroke (HR: 0.42; 95% CI: 0.13-1.32), but there was a higher rate of new coronary revascularization in the TAVR + PCI group (HR: 5.38; 95% CI: 1.73-16.7). CONCLUSIONS: In patients with severe AS and complex CAD, TAVR + PCI and SAVR + CABG were associated with similar rates of MACCE after a median follow-up period of 3 years, but TAVR + PCI recipients exhibited a higher risk for repeat coronary revascularization. Future trials are warranted.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Ann Thorac Surg ; 111(5): 1601-1606, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32950489

RESUMO

BACKGROUND: The impact of novel alternative access and valve type on radiation exposure during transcatheter aortic valve replacement (TAVR) has not yet been evaluated. This study sought to determine the impact of a transarterial approach and prosthesis type on physician and patient exposure to radiation during TAVR. METHODS: This was a prospective study including 140 consecutive patients undergoing TAVR by transfemoral (n = 102) or transcarotid (TC) (n = 38) access at 2 centers. Implanted valves were the self-expanding Evolut R/PRO system (Medtronic, Minneapolis, MN; n = 38) and the balloon-expandable SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA; n = 102). The primary endpoint was first operator radiation exposure. The secondary endpoint was patient radiation exposure. RESULTS: First operator radiation exposure was 4-fold greater during TC TAVR (P < .001). The use of a self-expanding valve was associated with a longer x-ray time (P = .015) and a 2-fold greater first operator radiation dose (P = .018). Patient radiation dose was not significantly affected by arterial approach (P = .055) or valve type (P = .095). After adjustment for potential confounders, the TC approach remained associated with a 174.8% (95% confidence interval, 80.6-318.3, P < .001) increase in first operator radiation dose, whereas the use of a self-expanding valve no longer influenced the first operator dose (P = .630). CONCLUSIONS: TC access and the use of a self-expanding valve were associated with a 4- and 2-fold greater first operator radiation exposure during TAVR procedures, respectively. Unlike the arterial approach, the effect of bioprosthesis type on radiation exposure was mainly related to x-ray time and was no longer significant after adjustment.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Exposição à Radiação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas , Feminino , Artéria Femoral , Humanos , Masculino , Exposição Ocupacional , Segurança do Paciente , Estudos Prospectivos , Desenho de Prótese
12.
Ann Thorac Surg ; 111(3): 951-957, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32710845

RESUMO

BACKGROUND: Transcarotid transcatheter aortic valve replacement (TAVR) recipients may be exposed to a higher ipsilateral subclinical cerebral ischemic burden compared with the contralateral hemisphere. We sought (1) to compare the cerebral ischemic burden of the 2 hemispheres after transcarotid TAVR, as evaluated by diffusion weighted-magnetic resonance imaging (DW-MRI), and (2) to identify the factors associated with ipsilateral ischemic burden. METHODS: This prospective study included 52 patients undergoing transcarotid TAVR, followed by a DW-MRI examination. All DW-MRIs were analyzed offline by a radiologist blinded to the clinical data. RESULTS: TAVR was performed through the left (n = 50) or right (n = 2) carotid artery. Procedural success was achieved in all patients, carotid dissection requiring patch closure occurred in 1 patient, and there were no periprocedural stroke events. At least 1 cerebral ischemic lesion was identified in the ipsilateral and contralateral hemisphere in 84.6% and 63.5% of patients, respectively (P = .005), and the number of ischemic lesions per patient was higher in the ipsilateral vs the contralateral hemisphere (2 [interquartile range, 1-5] vs 1 [interquartile range, 0-3], P = .005). The lesion volume (per lesion) and the average lesion volume (per patient) did not differ between the 2 hemispheres. A larger sheath/catheter size (≥18F vs ≤16F) was associated with a higher ipsilateral ischemic burden (P = .026). CONCLUSIONS: Carotid artery access for TAVR was associated with a higher number of cerebral ischemic lesions in the ipsilateral (vs contralateral) cerebral hemisphere. The use of a larger sheath/delivery system (≥18F) was associated with an increased ipsilateral ischemic burden.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Isquemia Encefálica/complicações , Embolia Intracraniana/etiologia , Complicações Pós-Operatórias , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Incidência , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/epidemiologia , Masculino , Estudos Prospectivos , Quebeque/epidemiologia , Fatores de Risco , Fatores de Tempo
13.
J Invasive Cardiol ; 32(6): E151-E157, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32479417

RESUMO

BACKGROUND: Many patients referred for a MitraClip intervention are finally refused for this intervention, and data are very scarce on their outcomes. Our study sought to determine the characteristics and outcomes of patients who are referred to a mitral valve clinic and are finally denied from a percutaneous mitral edge-to-edge repair. METHODS: A total of 210 patients referred to our clinic for severe mitral regurgitation were retrospectively analyzed. Fifty-seven patients underwent a MitraClip procedure. For exploratory purposes, a propensity-matched cohort comparing the patients accepted for a MitraClip procedure and those refused for any mitral intervention was analyzed. RESULTS: Among the 153 patients who were refused for MitraClip, 46% had functional MR, 42% had degenerative MR, and 11% had mixed disease. Reasons for denial included unfavorable anatomy, patient refusal, mitral valve surgery referral, cardiac resynchronization therapy, other advanced heart failure therapies, and palliative care. After a mean follow-up of 13 months, 50% were in New York Heart Association class I or II, 63% had less than severe MR, and mortality rate was 29%. In the propensity-matched cohort, there was no difference in symptoms improvement, but there was less overall mortality (P=.01), cardiovascular mortality (P<.01) and severe MR (P<.01) in the MitraClip group. CONCLUSIONS: A multidisciplinary heart team evaluation for complex MR patients can be useful not solely for selecting the ideal MitraClip eligible patients, but also to select the best treatment strategy in each individualized context.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Encaminhamento e Consulta , Estudos Retrospectivos , Resultado do Tratamento
14.
J Interv Cardiol ; 2019: 3579671, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772527

RESUMO

OBJECTIVES: To report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves. BACKGROUND: Coronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges. METHODS: Over 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods. RESULTS: Neither CAs-nor PCIs-performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values. CONCLUSIONS: Performance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence.


Assuntos
Valvuloplastia com Balão , Angiografia Coronária , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Doses de Radiação
15.
Can J Cardiol ; 35(10): 1419.e17-1419.e20, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31601415

RESUMO

We report a patient with severe aortic stenosis with an extremely high calcium score who underwent a transfemoral transcatheter aortic valve replacement with an Evolut R (Medtronic, Minneapolis, MN) and needed a valve-in-valve approach with a SAPIEN 3 (Edwards Lifesciences, Irvine, CA) to treat significant paravalvular leak. Interestingly, the closure time with adenosine diphosphate, assessed using the Platelet Function Analyzer 100 (Siemens Healthcare Diagnostics, Los Angeles, CA), measured after each important step of this complex procedure, correlated very well with the severity of the paravalvular leak.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Difosfato de Adenosina/sangue , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Feminino , Humanos , Índice de Gravidade de Doença , Fatores de Tempo
16.
Circulation ; 139(23): 2685-2702, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31157994

RESUMO

The presence of a small aortic annulus poses a considerable challenge in the management of patients with severe aortic stenosis, especially in elderly women, where it is a very frequent finding. The optimal approach for treating these patients remains controversial, and several surgical strategies such as aortic root enlargement, supra-annular stented prosthetic valves, stentless bioprosthesis, and sutureless bioprostheses have been proposed to improve valve hemodynamics and clinical outcomes. More recently, transcatheter aortic valve replacement has emerged as a valid alternative for the treatment of aortic stenosis and excellent valve hemodynamic results have been observed among patients with a small aortic annulus. The purpose of this review is to provide an overview of the current definition, prevalence, and clinical impact of small aortic annulus in patients with aortic stenosis, and evaluate the different therapeutic strategies currently available to improve valve hemodynamics and outcomes in this population.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos sem Sutura , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Procedimentos Cirúrgicos sem Sutura/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
Psychoneuroendocrinology ; 106: 102-110, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30965200

RESUMO

17ß-Estradiol (E2) is a potent neuromodulator capable of producing changes in inhibitory synaptic transmission by either changing pre-synaptic GABA release or post-synaptic GABAA receptor function. Physiologically, E2 is important for energy homeostasis, influencing food consumption, body weight, adipose tissue metabolism and energy expenditure. E2 may influence energy homeostasis through estrogen receptor-rich regions such as the oval bed nucleus of the stria-terminalis (ovBNST). However, the neurophysiological effects of estradiol within the ovBNST remain largely unknown. Understanding how E2 affects inhibitory transmission may elucidate the ovBNST's contribution to energy homeostasis. Here, using brain slice electrophysiology, we saw that E2 produced a long-term potentiation (LTP) of GABAA synaptic transmission (LTPGABA) in the ovBNST in male rats. E2 acted on estrogen receptors α and G-protein coupled estrogen receptors (GPER), involved protein kinase activation and required an intact endocannabinoid system. The effects of E2 in males were sensitive to 24 h of food deprivation. In females, E2 was 100-fold more potent at producing LTPGABA ovBNST compared to male rats and involved all three known subtypes of estrogen receptors (ERα, ERß, and GPER). These results demonstrate that E2 is a potent neuromodulator of inhibitory synaptic transmission within the ovBNST of both sexes to potentially regulate energy homeostasis.


Assuntos
Estradiol/metabolismo , Núcleos Septais/efeitos dos fármacos , Transmissão Sináptica/fisiologia , Animais , Receptor alfa de Estrogênio/metabolismo , Estrogênios/metabolismo , Feminino , Hipocampo/metabolismo , Potenciação de Longa Duração/efeitos dos fármacos , Masculino , Neurônios/metabolismo , Ratos , Ratos Long-Evans , Receptores de Estrogênio/metabolismo , Caracteres Sexuais
19.
Circ Cardiovasc Interv ; 11(11): e006388, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30571205

RESUMO

Background The optimal access for patients undergoing transcatheter aortic valve replacement (TAVR) who are not candidates for a transfemoral approach has not been elucidated. The purpose of this study was to compare the safety, feasibility, and early clinical outcomes of transcarotid TAVR compared with thoracic approaches. Methods and Results From a multicenter consecutive cohort of 329 alternative-access TAVR patients (2012-2017), we identified 101 patients who underwent transcarotid TAVR and 228 patients who underwent a transapical or transaortic TAVR. Preprocedural success and 30-day clinical outcomes were compared using multivariable propensity score analysis to account for between-group differences in baseline characteristics. All transcarotid cases were performed under general anesthesia, mainly using the left common carotid artery (97%). Propensity-matched groups had similar rates of 30-day all-cause mortality (2.1% versus 4.6%; P=0.37), stroke (2.1% versus 3.5%; P=0.67; transcarotid versus transapical/transaortic, respectively), new pacemaker implantation, and major vascular complications. Transcarotid TAVR was associated with significantly less new-onset atrial fibrillation (3.2% versus 19.0%; P=0.002), major or life-threatening bleeding (4.3% versus 19.9%; P=0.002), acute kidney injury (none versus 12.1%; P=0.002), and shorter median length of hospital stay (6 versus 8 days; P<0.001). Conclusions Transcarotid vascular access for TAVR is safe and feasible and is associated with encouraging short-term clinical outcomes. Our data suggest a clinical benefit of transcarotid TAVR with respect to atrial fibrillation, major bleeding, acute kidney injury, and length of stay compared with the more invasive transapical or transaortic strategies. Randomized studies are required to ascertain whether transcarotid TAVR yields equivalent results to other alternative vascular access routes.


Assuntos
Aorta , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Artéria Carótida Primitiva , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Canadá/epidemiologia , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , França/epidemiologia , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
20.
Circ Cardiovasc Interv ; 11(9): e007038, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354588

RESUMO

BACKGROUND: Data on long-term outcomes after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) are scarce. The objective of this study was to determine the long-term clinical outcomes and structural valve degeneration (SVD) over time in patients undergoing ViV-TAVR. METHODS AND RESULTS: Consecutive patients undergoing ViV-TAVR in 9 centers between 2009 and 2015 were included. Patients were followed yearly, and clinical and echocardiography data were collected prospectively. SVD was defined as subclinical (increase >10 mm Hg in mean transvalvular gradient+decrease >0.3 cm2 in valve area or new-onset mild or moderate aortic regurgitation) and clinically relevant (increase >20 mm Hg in mean transvalvular gradient+decrease >0.6 cm2 in valve area or new-onset moderate-to-severe aortic regurgitation). A total of 116 patients (mean age, 76±11 years; 64.7% male; mean Society of Thoracic Surgeons score, 8.0±5.1%) were included. Balloon- and self-expandable valves were used in 47.9% and 52.1% of patients, respectively, and 30-day mortality was 6.9%. At a median follow-up of 3 years (range, 2-7 years), 30 patients (25.9%) had died, 20 of them (17.2%) from cardiovascular causes. Average mean transvalvular gradients remained stable up to 5-year follow-up ( P=0.92), but clinically relevant SVD occurred in 3/99 patients (3.0%), and 15/99 patients (15.1%) had subclinical SVD. One patient with SVD had redo ViV-TAVR. CONCLUSIONS: About one-fourth of ViV-TAVR recipients had died after a median follow-up of 3 years. Overall valve hemodynamics remained stable over time and clinically relevant SVD was infrequent, but 1 out of 10 patients exhibited some degree of SVD.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler em Cores , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA