Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nephrol ; 36(9): 2457-2465, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37093492

RESUMO

BACKGROUND: In late 2018, the production of 51Chromium-labelled ethylenediamine tetra-acetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for measuring glomerular filtration rate, was halted. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) has been validated for GFR measurement with a single bolus injection, a procedure not suitable in patients with extracellular compartment hyperhydration. In such cases, a bolus followed by continuous infusion of the tracer is required. The aim of this study was to evaluate whether 99mTc-DTPA with the infusion protocol can replace 51Cr-EDTA for GFR measurement. METHODS: We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously: 51Cr-EDTA and 99mTc-DTPA bolus and continuous infusion were administered concomitantly through the same intravenous route. Over four and a half hours, plasma and urine samples were collected to calculate urinary and plasma clearance. RESULTS: Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of 51Cr-EDTA and 99mTc-DTPA was 52.4 ± 22.5 mL/min and 52.8 ± 22.6 mL/min, respectively (p = 0.47), with a mean bias of 0.39 ± 2.50 mL/min, an accuracy within 10% of 100% (95% CI 100; 100) and a Pearson correlation coefficient of 0.994. Mean plasma clearance of 51Cr-EDTA and 99mTc-DTPA was 54.8 ± 20.9 mL/min and 54.4 ± 20.9 mL/min, respectively (p = 0.61), with a mean bias of - 0.43 ± 3.89 mL/min, an accuracy within 10% of 77% (95% CI 59; 91) and a Pearson correlation coefficient of 0.983. CONCLUSIONS: Urinary and plasma clearance of 99mTc-DTPA can be used with the infusion protocol to measure GFR.


Assuntos
Nefropatias , Pentetato de Tecnécio Tc 99m , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Cromo , Ácido Edético , Taxa de Filtração Glomerular , Ácido Pentético , Estudos Prospectivos , Tecnécio
2.
J Nephrol ; 34(3): 729-737, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33661505

RESUMO

PURPOSE: The production of 51Cr-labelled ethylenediaminetetraacetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of 51Cr-EDTA and 99mTc-DTPA for GFR and extracellular fluid measurement. METHODS: In a multi-centre prospective study, 51Cr-EDTA and 99mTc-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time. RESULTS: Mean age was 52.2 ± 14.5 years, 59% were men. Urinary clearances of 51Cr-EDTA and 99mTc-DTPA were 64.1 ± 27.6 and 66.1 ± 28.0 mL/min, respectively, with a mean bias of 2.00 ± 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R2) of 0.994. Plasma clearances of 51Cr-EDTA and 99mTc-DTPA were 66.1 ± 25.8 and 68.1 ± 26.6 mL/min, respectively, with a mean bias of 1.96 ± 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R2 of 0.985. Distribution volumes were 17.3 ± 4.6 L for 51Cr-EDTA and 16.6 ± 4.6 L for 99mTc-DTPA (R2 0.930). CONCLUSION: The accuracy and precision of 99mTc-DTPA clearance, compared to 51Cr-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to 51Cr-EDTA for GFR measurement.


Assuntos
Pentetato de Tecnécio Tc 99m , Tecnécio , Ácido Edético , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA