Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Int J Hyperthermia ; 40(1): 2255755, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37710404

RESUMO

PURPOSE: To develop a computational model of microwave ablation (MWA) with a thermal accelerant gel and apply the model toward interpreting experimental observations in ex vivo bovine and in vivo porcine liver. METHODS: A 3D coupled electromagnetic-heat transfer model was implemented to characterize thermal profiles within ex vivo bovine and in vivo porcine liver tissue during MWA with the HeatSYNC thermal accelerant. Measured temperature dependent dielectric and thermal properties of the HeatSYNC gel were applied within the model. Simulated extents of MWA zones and transient temperature profiles were compared against experimental measurements in ex vivo bovine liver. Model predictions of thermal profiles under in vivo conditions in porcine liver were used to analyze thermal ablations observed in prior experiments in porcine liver in vivo. RESULTS: Measured electrical conductivity of the HeatSYNC gel was ∼83% higher compared to liver at room temperature, with positive linear temperature dependency, indicating increased microwave absorption within HeatSYNC gel compared to tissue. In ex vivo bovine liver, model predicted ablation zone extents of (31.5 × 36) mm with the HeatSYNC, compared to (32.9 ± 2.6 × 40.2 ± 2.3) mm in experiments (volume differences 4 ± 4.1 cm3). Computational models under in vivo conditions in porcine liver suggest approximating the HeatSYNC gel spreading within liver tissue during ablations as a plausible explanation for larger ablation zones observed in prior in vivo studies. CONCLUSION: Computational models of MWA with thermal accelerants provide insight into the impact of accelerant on MWA, and with further development, could predict ablations with a variety of gel injection sites.


Assuntos
Fígado , Micro-Ondas , Animais , Bovinos , Suínos , Micro-Ondas/uso terapêutico , Fígado/cirurgia , Simulação por Computador , Condutividade Elétrica , Temperatura Alta
2.
Int J Hyperthermia ; 39(1): 664-674, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35465811

RESUMO

Microwave ablation (MWA) is becoming an increasingly important minimally invasive treatment option for localized tumors in many organ systems due to recent advancements in microwave technology that have conferred many advantages over other tumor ablation modalities. Despite these improvements in technology and development of applicators for site-specific tumor applications, the vast majority of commercially available MWA applicators are generally designed to create large-volume, symmetric, ellipsoid or spherically-shaped treatment zones and often lack the consistency, predictability, and spatial control needed to treat tumor targets near critical structures that are vulnerable to inadvertent thermal injury. The relatively new development and ongoing translation of directional microwave ablation (DMWA) technology, however, has the potential to confer an added level of control over the treatment zone shape relative to applicator position, and shows great promise to expand MWA's clinical applicability in treating tumors in challenging locations. This paper presents a review of the industry-standard commercially available MWA technology, its clinical applications, and its limitations when used for minimally-invasive tumor treatment in medical practice followed by discussion of new advancements in experimental directional microwave ablation (DMWA) technology, various techniques and approaches to its use, and examples of how this technology may be used to treat tumors in challenging locations that may otherwise preclude safe treatment by conventional omni-directional MWA devices.


Assuntos
Técnicas de Ablação , Neoplasias , Ablação por Radiofrequência , Técnicas de Ablação/métodos , Humanos , Micro-Ondas/uso terapêutico , Neoplasias/cirurgia
3.
Radiology ; 301(3): 533-540, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34581627

RESUMO

There is currently no consensus regarding preferred clinical outcome measures following image-guided tumor ablation or clear definitions of oncologic end points. This consensus document proposes standardized definitions for a broad range of oncologic outcome measures with recommendations on how to uniformly document, analyze, and report outcomes. The initiative was coordinated by the Society of Interventional Oncology in collaboration with the Definition for the Assessment of Time-to-Event End Points in Cancer Trials, or DATECAN, group. According to predefined criteria, based on experience with clinical trials, an international panel of 62 experts convened. Recommendations were developed using the validated three-step modified Delphi consensus method. Consensus was reached on when to assess outcomes per patient, per session, or per tumor; on starting and ending time and survival time definitions; and on time-to-event end points. Although no consensus was reached on the preferred classification system to report complications, quality of life, and health economics issues, the panel did agree on using the most recent version of a validated patient-reported outcome questionnaire. This article provides a framework of key opinion leader recommendations with the intent to facilitate a clear interpretation of results and standardize worldwide communication. Widespread adoption will improve reproducibility, allow for accurate comparisons, and avoid misinterpretations in the field of interventional oncology research. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Liddell in this issue.


Assuntos
Técnicas de Ablação/métodos , Neoplasias/cirurgia , Consenso , Humanos , Reprodutibilidade dos Testes , Sociedades Médicas
4.
J Vasc Interv Radiol ; 32(7): 1089.e1-1089.e9, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34210477

RESUMO

Musculoskeletal interventions are increasingly used with palliative and curative intent in the multidisciplinary treatment of oncology patients with bone and soft-tissue tumors. There is an unmet need for high-quality evidence to guide broader application and adoption of minimally invasive interventional technologies to treat these patients. Therefore, the Society of Interventional Radiology Foundation and the Society of Interventional Oncology collaborated to convene a research consensus panel to prioritize a research agenda addressing the gaps in the current evidence. This article summarizes the panel's proceedings and recommendations for future basic science and clinical investigation to chart the course for interventional oncology within the musculoskeletal system. Key questions that emerged addressed the effectiveness of ablation within specific patient populations, the effect of combination of ablation with radiotherapy and/or immunotherapy, and the potential of standardization of techniques, including modeling and monitoring, to improve the consistency and predictability of treatment outcomes.


Assuntos
Radiologia Intervencionista , Neoplasias de Tecidos Moles , Consenso , Humanos , Oncologia , Cuidados Paliativos
5.
J Thorac Dis ; 13(12): 6827-6837, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35070367

RESUMO

BACKGROUND: Percutaneous image-guided thermal ablation has an increasing role in the treatment of primary and metastatic lung tumors. Achieving acceptable clinical outcomes requires better tools for pre-procedure prediction of ablation zone size and shape. METHODS: This was a prospective, non-randomized, single-arm, multicenter study conducted by Medtronic (ClinicalTrials.gov ID: NCT02323854). Subjects scheduled for resection of metastatic or primary lung nodules underwent preoperative percutaneous microwave ablation. Ablation zones as measured via CT imaging following ablation immediately and before resection surgically versus predicted ablation zones as prescribed by the investigational system software were compared. This CT scan occurred after the ablation was finished but the antenna still in position. Time (minutes) from antenna placement to removal was 23.7±13.1 (n=14); median: 21.0 (range, 6.0 to 48.0). The definition of the secondary endpoint of complete ablation was 100% non-viable tumor cells based on nicotinamide adenine dinucleotide hydrogen (NADH) staining. Safety endpoints were type, incidence, and severity of adverse events. RESULTS: Fifteen patients (mean age 58.9 years; 67% male; 33% female) were enrolled in the study, 33.3% (5/15) with previous thoracic surgery, 73% (11/15) with metastasis, and 27% (4/15) with primary lung tumors. All underwent percutaneous microwave ablation followed by surgical resection the same day. Complete ablation was detected in 54.4% (6/11), incomplete ablation in 36.4% (4/11), and delayed necrosis in 9.1% (1/11). There were no device-related adverse events. Ablation zone volume was overestimated in all patients. CONCLUSIONS: Histological complete ablation was observed in 55% of subjects. CT scanning less than an hour after ablation and tissue shrinkage may account for the smaller zone of ablation observed compared to predicted by the investigational system software.

6.
J Vasc Interv Radiol ; 31(8): 1357-1364, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32457010

RESUMO

PURPOSE: To determine the effects of a thermal accelerant gel on temperature parameters during microwave liver ablation. MATERIALS AND METHODS: Sixteen consecutive liver ablations were performed in 5 domestic swine under general anesthesia with (n = 8) and without (n = 8) administration of thermal accelerant gel. Ablation zone temperature was assessed by real-time MR thermometry, measured as maximum temperature (Tmax) and the volume of tissue ≥ 60°C (V60). Tissue heating rate, ablation zone shape, and thermal energy deposition using the temperature degree-minutes at 43°C (TDM43) index were also measured. Differences between groups were analyzed using generalized mixed modeling with significance set at P = .05. RESULTS: Mean peak ablation zone temperature was significantly greater with thermal accelerant use (mean Tmax, thermal accelerant: 120.0°C, 95% confidence interval [CI] 113.0°C-126.9°C; mean Tmax, control: 80.3°C, 95% CI 72.7°C-88.0°C; P < .001), and a significantly larger volume of liver tissue achieved or exceeded 60°C when thermal accelerant was administered (mean V60, thermal accelerant: 22.2 cm3; mean V60, control: 15.9 cm3; P < .001). Significantly greater thermal energy deposition was observed during ablations performed with accelerant (mean TDM43, thermal accelerant: 198.4 min, 95% CI 170.7-230.6 min; mean TDM43, control: 82.8 min, 95% CI 80.5-85.1 min; P < .0001). The rate of tissue heating was significantly greater with thermal accelerant use (thermal accelerant: 5.8 min ± 0.4; control: 10.0 min; P < .001), and accelerant gel ablations demonstrated a more spherical temperature distribution (P = .002). CONCLUSIONS: Thermal accelerant use is associated with higher microwave ablation zone temperatures, greater thermal energy deposition, and faster and more spherical tissue heating compared with control ablations.


Assuntos
Técnicas de Ablação , Temperatura Alta , Fígado/cirurgia , Imageamento por Ressonância Magnética , Micro-Ondas , Polímeros Responsivos a Estímulos/administração & dosagem , Cirurgia Assistida por Computador , Termometria , Animais , Géis , Fígado/diagnóstico por imagem , Masculino , Modelos Animais , Sus scrofa
7.
J Vasc Interv Radiol ; 31(7): 1170-1177.e2, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32171539

RESUMO

PURPOSE: To experimentally characterize a microwave (MW) ablation applicator designed to produce directional ablation zones. MATERIALS AND METHODS: Using a 14-gauge, 2.45-GHz side-firing MW ablation applicator, 36 ex vivo bovine liver ablations were performed. Ablations were performed at 60 W, 80 W, and 100 W for 3, 5, and 10 minutes (n = 4 per combination). Ablation zone forward and backward depth and width were measured and directivity was calculated as the ratio of forward to backward depth. Thirteen in vivo ablations were performed in 2 domestic swine with the applicator either inserted into the liver (80 W, 5 min, n = 3; 100 W, 5 min, n = 3; 100 W, 10 min, n = 2) or placed on the surface of the liver with a nontarget tissue placed on the back side of the applicator (80 W, 5 min, n = 5). The animals were immediately euthanized after the procedure; the livers were harvested and sectioned perpendicular to the axis of the applicator. In vivo ablation zones were measured following viability staining and assessed on histopathology. RESULTS: Mean ex vivo ablation forward depth was 8.3-15.5 mm. No backward heating was observed at 60 W, 3-5 minutes; directivity was 4.7-11.0 for the other power and time combinations. In vivo ablation forward depth was 10.3-11.5 mm, and directivity was 11.5-16.1. No visible or microscopic thermal damage to nontarget tissues in direct contact with the back side of the applicator was observed. CONCLUSIONS: The side-firing MW ablation applicator can create directional ablation zones in ex vivo and in vivo tissues.


Assuntos
Técnicas de Ablação/instrumentação , Fígado/cirurgia , Micro-Ondas , Irrigação Terapêutica/instrumentação , Técnicas de Ablação/efeitos adversos , Animais , Bovinos , Desenho de Equipamento , Feminino , Fígado/patologia , Teste de Materiais , Micro-Ondas/efeitos adversos , Modelos Animais , Sus scrofa , Irrigação Terapêutica/efeitos adversos , Sobrevivência de Tecidos
8.
J Thorac Oncol ; 15(7): 1200-1209, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32151777

RESUMO

OBJECTIVE: To assess the safety and local recurrence-free survival in patients after cryoablation for treatment of pulmonary metastases. METHODS: This multicenter, prospective, single-arm, phase 2 study included 128 patients with 224 lung metastases treated with percutaneous cryoablation, with 12 and 24 months of follow-up. The patients were enrolled on the basis of the outlined key inclusion criteria, which include one to six metastases from extrapulmonary cancers with a maximal diameter of 3.5 cm. Time to progression of the index tumor(s), metastatic disease, and overall survival rates were estimated using the Kaplan-Meier method. Complications were captured for 30 days after the procedure, and changes in performance status and quality of life were also evaluated. RESULTS: Median size of metastases was 1.0 plus or minus 0.6 cm (0.2-4.5) with a median number of tumors of 1.0 plus or minus 1.2 cm (one to six). Local recurrence-free response (local tumor efficacy) of the treated tumor was 172 of 202 (85.1%) at 12 months and 139 of 180 (77.2%) at 24 months after the initial treatment. After a second cryoablation treatment for recurrent tumor, secondary local recurrence-free response (local tumor efficacy) was 184 of 202 (91.1%) at 12 months and 152 of 180 (84.4%) at 24 months. Kaplan-Meier estimates of 12- and 24-month overall survival rates were 97.6% (95% confidence interval: 92.6-99.2) and 86.6% (95% confidence interval: 78.7-91.7), respectively. Rate of pneumothorax that required pleural catheter placement was 26% (44/169). There were eight grade 3 complication events in 169 procedures (4.7%) and one (0.6%) grade 4 event. CONCLUSION: Percutaneous cryoablation is a safe and effective treatment for pulmonary metastases.


Assuntos
Criocirurgia , Neoplasias Renais , Neoplasias Pulmonares , Humanos , Neoplasias Renais/cirurgia , Neoplasias Pulmonares/cirurgia , Recidiva Local de Neoplasia/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
9.
J Vasc Interv Radiol ; 31(2): 286-293, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31902554

RESUMO

PURPOSE: To evaluate tumor and ablation zone morphology and densitometry related to tumor recurrence in participants with Stage IA non-small cell lung cancer undergoing radiofrequency ablation in a prospective, multicenter trial. MATERIALS AND METHODS: Forty-five participants (median 76 years old; 25 women; 20 men) from 16 sites were followed for 2 years (December 2006 to November 2010) with computed tomography (CT) densitometry. Imaging findings before and after ablation were recorded, including maximum CT attenuation (in Hounsfield units) at precontrast and 45-, 90-, 180-, and 300-s postcontrast. RESULTS: Every 1-cm increase in the largest axial diameter of the ablation zone at 3-months' follow-up compared to the index tumor reduced the odds of 2-year recurrence by 52% (P = .02). A 1-cm difference performed the best (sensitivity, 0.56; specificity, 0.93; positive likelihood ratio of 8). CT densitometry precontrast and at 45 seconds showed significantly different enhancement patterns in a comparison among pretreated lung cancer (delta = +61.2 HU), tumor recurrence (delta = +57 HU), and treated tumor/ablation zone (delta [change in attenuation] = +16.9 HU), (P < .0001). Densitometry from 45 to 300 s was also different among pretreated tumor (delta = -6.8 HU), recurrence (delta = -11.2 HU), and treated tumor (delta = +12.1 HU; P = .01). Untreated and residual tumor demonstrated washout, whereas treated tumor demonstrated increased attenuation. CONCLUSIONS: An ablation zone ≥1 cm larger than the initial tumor, based on 3-month follow-up imaging, is recommended to decrease odds of recurrence. CT densitometry can delineate tumor versus treatment zones.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/cirurgia , Ablação por Radiofrequência , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Margens de Excisão , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Estados Unidos
10.
J Thorac Imaging ; 34(4): 266-277, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31094898

RESUMO

Interventional oncology and management of thoracic malignancies with ablative techniques are becoming ever more recognized therapeutic options. With increased understanding, development, and utility of the ablative techniques, the indications are expanding and efficacy improving. Lung cancer was among the first indications for lung ablation and remains most challenging with multiple therapeutic options. For inoperable patients, the current literature demonstrates equivalent survivals between ablation, sublobar resection, and stereotactic body radiation. Oligometastatic disease remains the most common indication for lung ablation and is gaining acceptance among the oncology community, as lung ablation provides limited patient downtime, repeatability, and minimal to no loss of respiratory function. Other indications for ablation are being explored, including recurrent mesothelioma, drop metastasis from thymoma, and limited pleural metastasis, with excellent local control of tumor and limited complications. Follow-up after ablation is essential to detect early complications, observe the natural evolution of the ablation zone, and detect recurrence. Standardized imaging follow-up allows for these goals to be achieved and provides a framework for oncology practice. In this article, the role of ablation in the management of thoracic neoplasms and postablation imaging features are reviewed. The radiologists, in particular, thoracic radiologists should be able to identify candidates who can benefit from ablation familiarize themselves with postablation imaging features, and recognize the evolution of the postablation zone and hence detect early recurrence.


Assuntos
Ablação por Cateter/métodos , Neoplasias Pulmonares/cirurgia , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
11.
Radiology ; 291(2): 504-510, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30747590

RESUMO

Background Thermal ablation of cancers may be associated with high rates of local tumor progression. A thermal accelerant gel has been developed to improve the transmission of microwave energy in biologic tissues with the aim of enlarging the thermal ablation zone. Purpose To determine the effects of a thermal accelerant gel on microwave ablation zone volumes in porcine lung and to compare percutaneous and endobronchial delivery methods. Materials and Methods Thirty-two consecutive microwave lung ablations were performed in nine 12-week-old domestic male swine under general anesthesia by using fluoroscopic guidance between September 2017 and April 2018. Experimental ablations were performed following percutaneous injection of thermal accelerant into the lung (n = 16) or after endobronchial injection by using a flexible bronchoscope (n = 8). Control ablations were performed without accelerant gel (n = 8). Lung tissue was explanted after the animals were killed, and ablation zone volumes were calculated as the primary outcome measure by using triphenyltetrazolium chloride vital staining. Differences in treatment volumes were analyzed by generalized mixed modeling. Results Thermal accelerant ablation zone volumes were larger than control ablations (accelerant vs control ablation, 4.3 cm3 [95% confidence interval: 3.4, 5.5] vs 2.1 cm3 [95% confidence interval: 1.4, 2.9], respectively; P < .001). Among ablations with the thermal accelerant, those performed following percutaneous injection had a larger average ablation zone volume than those performed following endobronchial injection (percutaneous vs endobronchial, 4.8 cm3 [95% confidence interval: 3.6, 6.4] vs 3.3 cm3 [95% confidence interval: 2.9, 3.8], respectively; P = .03). Ablation zones created after endobronchial gel injection were more uniform in size distribution (standard error, percutaneous vs endobronchial: 0.13 vs 0.07, respectively; P = .03). Conclusion Use of thermal accelerant results in larger microwave ablation zone volumes in normal porcine lung tissue. Percutaneous thermal accelerant injection leads to a larger ablation zone volume compared with endobronchial injection, whereas a more homogeneous and precise ablation zone size is observed by using the endobronchial approach. © RSNA, 2019 See also the editorial by Goldberg in this issue.


Assuntos
Técnicas de Ablação/métodos , Géis/administração & dosagem , Hipertermia Induzida/métodos , Pulmão/diagnóstico por imagem , Administração Cutânea , Administração por Inalação , Animais , Meios de Contraste/administração & dosagem , Meios de Contraste/química , Fluoroscopia/métodos , Géis/química , Pulmão/cirurgia , Masculino , Micro-Ondas , Cirurgia Assistida por Computador , Sus scrofa , Suínos
12.
J Surg Res ; 232: 1-6, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30463704

RESUMO

BACKGROUND: The purpose of this study is to compare the ablation performance between a synchronous microwave ablation (MWA) system and a commercially available asynchronous system in ex vivo bovine liver and evaluate the efficacy of ablation at varying entrance angles. MATERIALS AND METHODS: Two 915-MHz MWA systems were used in bench top ex vivo bovine livers with various conditions (synchronous versus asynchronous). Using synchronous technology ablations to liver, kidney, or lung at angles of 0, 15, 30, and 90° were evaluated. RESULTS: Synchronous and asynchronous MWA systems created mean ablation zone volumes of 26.4 and 15.8 cm3, 62.9 and 45.4 cm3, 90.8 and 56.4, and 75.7 and 54.8 cm3 with single, double (2 microwave probes in use simultaneous) (2 cm spacing), and triple (three probes in use simultaneously) (2 cm and 3 cm spacing) antennae configurations, respectively; adjusted P-values ≤ 0.006. Ablation defects were similar across all groups when evaluated for entrance angle. Specifically, when comparing 0-degree angle to all other angles, achieved zones of ablation (ZA) were similar (mean ± standard deviation for 0-degree versus all other angles: 8.72 ± 4.84 versus 9.38 ± 4.11 cm2, P = 0.75). The use of the long-tip probe resulted in a statistically significant increase in the achieved ZA when compared to the short tip probe (10.9 ± 4.3 versus 6.5 ± 2.4, respectively; P = 0.01). CONCLUSIONS: Newly developed synchronous microwave technology creates significantly larger ablation zones when compared to an existing asynchronous commercially available system. The angle of approach does not affect the resulting ZA. This is clinically relevant as true 0-degree angle is often difficult to obtain.


Assuntos
Ablação por Cateter/métodos , Micro-Ondas/uso terapêutico , Animais , Suínos
13.
J Vasc Interv Radiol ; 29(9): 1240-1244, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30075976

RESUMO

PURPOSE: To determine diagnostic yield of renal biopsies performed in patients referred for image-guided tumor ablation (IGTA) and the frequency with which biopsy results would have obviated the need for subsequent ablation. MATERIALS AND METHODS: Retrospective review of an internal ablation database of a single institution revealed 401 consecutive percutaneous renal mass IGTAs performed from April 2000 to April 2015. Of 401 ablations, 32 were excluded, yielding 369 ablation events in 342 patients, which represented the study cohort. Patients were subdivided into groups according to whether or not biopsy was performed. Lesions were categorized according to size, malignancy/benignity, and pathology. RESULTS: IGTA was performed with biopsy for 317/369 (85.9%) and without biopsy for 52/369 (14.1%) lesions. Overall diagnostic yield for percutaneous biopsy was 94.3% (299/317). Based on biopsy results, 82.6% (262/317) were classified as malignant or suspicious, 9.5% (30/317) were classified as likely benign, and 2.2% (7/317) were classified as definitively benign. Only definitively benign lesions were designated as obviating the need for IGTA. IGTA was supported by biopsy results in the remaining 97.8% (310/317), including renal cell carcinomas, oncocytic neoplasms, metastases, and nondiagnostic biopsy results. CONCLUSIONS: Biopsy of renal masses with suspicious imaging features rarely (2.2%) obviated the need for IGTA. For patients who have undergone counseling and have elected to forgo active surveillance and surgical options, biopsy can safely be performed concomitantly with ablation.


Assuntos
Técnicas de Ablação , Biópsia , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Tempo para o Tratamento , Técnicas de Ablação/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Carga Tumoral , Procedimentos Desnecessários
14.
Int J Hyperthermia ; 35(1): 62-70, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29807450

RESUMO

PURPOSE: To retrospectively review long-term oncologic outcomes after ultrasound (US)-guided percutaneous microwave ablation (MWA) of T1a renal cell carcinoma (RCC) and to identify the incidence and risk factors that predict local tumor progression (LTP) after MWA of RCC. MATERIALS AND METHODS: The present study was approved by the institutional review board. A total of 162 patients with 171 RCC nodules (mean size, 2.6 ± 0.8 cm; range, 0.6-4.0 cm) were treated by MWA between April 2006 and January 2017. The influence of eight factors (age; sex; longest tumor diameter; tumor number, location and pathology type; ablation power and time) affecting the risk of LTP was assessed. Univariate Kaplan-Meier and Cox proportional hazard models were used for statistical analysis. RESULTS: LTP occurred in five patients (5 tumors) after US-guided percutaneous MWA of stage T1a RCC. The overall occurrence of LTP was 2.9% per tumor and 3.0% per patient with a median follow-up of 45.5 months. Among the 162 patients, there were no instances of LTP-related deaths; however, 20 patients died of other diseases. All patients with LTP survived through follow-up. The survival rate of LTP-free patients at 1, 3 and 5 years were 98.7%, 89.5% and 82.1%, respectively (p = .38). Univariate and multivariate analysis identified tumor location to be the only independent predictor of LTP. CONCLUSIONS: US-guided percutaneous MWA for T1a RCC achieved a relatively low LTP incidence rate. Tumors adjacent to the renal pelvis or bowel increased the potential of LTP occurrence.


Assuntos
Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/diagnóstico por imagem , Ablação por Cateter/métodos , Neoplasias Renais/complicações , Neoplasias Renais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/patologia , Progressão da Doença , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Adulto Jovem
15.
Int J Hyperthermia ; 34(1): 11-18, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28540805

RESUMO

OBJECTIVES: To investigate the effects of a novel caesium-based thermal accelerant (TA) agent on ablation zone volumes following in vivo microwave ablation of porcine liver and skeletal muscle, and to correlate the effects of TA with target organ perfusion. MATERIALS AND METHODS: This prospective study was performed following institutional animal care and use committee approval. Microwave ablation was performed in liver and resting skeletal muscle in eight Sus scrofa domesticus swine following administration of TA at concentrations of 0 mg/mL (control), 100 mg/mL and 250 mg/mL. Treated tissues were explanted and stained with triphenyltetrazolium chloride (TTC) for quantification of ablation zone volumes, which were compared between TA and control conditions. Hematoxylin and eosin (H&E) staining was also performed for histologic analysis. General mixed modelling with a log-normal distribution was used for all quantitative comparisons (p = 0.05). RESULTS: A total of 28 ablations were performed in the liver and 18 in the skeletal muscle. The use of TA significantly increased ablation zone volumes in a dose-dependent manner in both the porcine muscle and liver (p < 0.01). Both the absolute mean ablation zone volume and percentage increase in ablation zone volume were greater in the resting skeletal muscle than in the liver. In one swine, a qualitative mitigation of heat sink effects was observed by TTC and H&E staining. Non-lethal polymorphic ventricular tachycardia was identified in one swine, treated with intravenous amiodarone. CONCLUSIONS: The use of a novel TA agent significantly increased mean ablation zone volumes following microwave ablation using a porcine model. The relationship between TA administration and ablation size was dose-dependent and inversely proportional to the degree of target organ perfusion, and a qualitative reduction in heat-sink effects was observed.


Assuntos
Ablação por Cateter/métodos , Micro-Ondas , Radioterapia Guiada por Imagem/métodos , Animais , Masculino , Modelos Animais , Suínos
16.
Cardiovasc Intervent Radiol ; 40(9): 1401-1407, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28462442

RESUMO

OBJECTIVES: To evaluate the rate of short-term complications associated with microwave ablation of lung tumors located near the heart. METHODS: This HIPAA-compliant study was performed with a waiver for informed consent. Patients who underwent microwave ablation of lung tumors located 10 mm or less from the heart were identified by retrospective chart review. Both primary and metastatic tumors were included. Only tumors directly adjacent to one of the four cardiac chambers were included. All patients were treated in a single session using CT guidance with continuous electrocardiographic monitoring. Rates of new-onset arrhythmia and myocardial infarction (MI) within 90 days of the procedure were quantified, and evidence of cardiac or pericardiac injury was assessed for using post-ablation contrast-enhanced chest CT, electrocardiography (EKG), and-when available-echocardiography. Complications were graded using the Common Terminology Criteria for Adverse Events (CTCAE) system. RESULTS: Ten patients (four males, six females; mean age 73.1 ± 9.5 years) met all inclusion criteria. Mean tumor distance from the heart was 3 mm (range, 0-6 mm). New-onset arrhythmia was not observed during or following any of the microwave ablation treatments, and there were no documented 90-day MI events. CTCAE Grade 1 complications were observed by CT in eight patients, most commonly mild focal pericardial thickening. EKG and echocardiography were normal in all patients. No major complications (CTCAE Grade 3 or greater) were observed. CONCLUSIONS: Microwave ablation of lung tumors located 10 mm or less from the heart appears to have low associated short-term morbidity and may be appropriate in selected patients.


Assuntos
Ablação por Cateter/métodos , Neoplasias Cardíacas/cirurgia , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Theranostics ; 7(4): 1026-1035, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28382173

RESUMO

The primary challenge in thermal ablation of liver tumors (e.g. hepatocellular carcinoma and hepatic colorectal cancer) is the relatively high recurrence rate (~30%) for which incomplete ablation at the periphery of the tumor is the most common reason. In an attempt to overcome this, we have developed a novel thermal accelerant (TA) agent capable of augmenting microwave energy from a distance normally unattainable by a single microwave ablation antenna. This cesium-based block co-polymer compound transforms from a liquid to a gel at body temperature and is intrinsically visible by computed tomography. Using an agarose phantom model, herein we demonstrate that both the rate and magnitude of temperature increase during microwave ablation were significantly greater in the presence of TA when compared with controls. These results suggest robust augmentation of microwave energy, and may translate into larger ablation zone volumes within biologic tissues. Further work using in vivo techniques is necessary to confirm these findings.


Assuntos
Técnicas de Ablação/métodos , Meios de Contraste/administração & dosagem , Hipertermia Induzida/métodos , Micro-Ondas/uso terapêutico , Radioterapia Guiada por Imagem/métodos , Meios de Contraste/química , Neoplasias/radioterapia , Tomografia Computadorizada por Raios X
18.
Eur J Radiol ; 89: 136-139, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267529

RESUMO

PURPOSE: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. MATERIALS AND METHODS: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440mA with 5mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. RESULTS: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p=<0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. CONCLUSION: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.


Assuntos
Técnicas de Ablação/instrumentação , Fígado/diagnóstico por imagem , Neoplasias/diagnóstico por imagem , Técnicas de Ablação/métodos , Algoritmos , Animais , Artefatos , Bovinos , Feminino , Humanos , Neoplasias/cirurgia , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos
19.
J Vasc Interv Radiol ; 28(2): 206-211, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27993505

RESUMO

PURPOSE: To determine the long-term safety and efficacy of microwave (MW) ablation in the treatment of lung tumors at a single academic medical center. MATERIALS AND METHODS: Retrospective review was performed of 108 patients (42 female; mean age, 72.5 y ± 10.3 [standard deviation]) who underwent computed tomography (CT)-guided percutaneous MW ablation for a single lung malignancy. Eighty-two were primary non-small-cell lung cancers and 24 were metastatic tumors (9 colorectal carcinoma, 2 renal-cell carcinoma, 4 sarcoma, 2 lung, and 7 other). Mean maximum tumor diameter was 29.6 mm ± 17.2. Patient clinical and imaging data were reviewed. Statistical analysis was performed by Kaplan-Meier modeling and logistic regression. RESULTS: Odds of primary technical success were 11.1 times higher for tumors < 3 cm vs those > 3 cm (95% confidence interval [CI], 2.97-41.1; P = .0003). For every millimeter increase in original tumor maximal diameter (OMD), the odds of not attaining success increased by 7% (95% CI, 3%-10%; P = .0002). For every millimeter increase in OMD, the odds of complications increased by 3% (95% CI, 0.1%-5%; P = .04). Median time to tumor recurrence was 62 months (95% CI, 29, upper bound not reached; range, 0.2-96.6 mo). Recurrence rates were estimated at 22%, 36%, and 44% at 1, 2, and 3 years, respectively. Recurrence rates were estimated at 31% at 13 months for tumors > 3 cm and 17% for those < 3 cm. Complications included pneumothorax (32%), unplanned hospital admission (28%), pain (20%), infection (7%), and postablation syndrome (4%). CONCLUSIONS: This study further supports the safe and effective use of MW ablation for the treatment of lung tumors.


Assuntos
Técnicas de Ablação , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Nódulo Pulmonar Solitário/cirurgia , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Centros Médicos Acadêmicos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma Pulmonar de Células não Pequenas/secundário , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Micro-Ondas/efeitos adversos , Recidiva Local de Neoplasia , Razão de Chances , Complicações Pós-Operatórias/etiologia , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Rhode Island , Fatores de Risco , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/mortalidade , Nódulo Pulmonar Solitário/patologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
20.
Int J Hyperthermia ; 33(1): 25-33, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27411731

RESUMO

Approximately 30% of early stage lung cancer patients are not surgical candidates due to medical co-morbidities, poor cardiopulmonary function and advanced age. These patients are traditionally offered chemotherapy and radiation, which have shown relatively modest improvements in mortality. For over a decade, percutaneous image-guided ablation has emerged as a safe, cost-effective, minimally invasive treatment alternative for patients who would otherwise not qualify for surgery. Although radiofrequency ablation (RFA) is currently the most extensively studied and widely utilised technique in the treatment of lung malignancies, there is a growing body of evidence that microwave ablation (MWA) has several unique benefits over RFA and cryoablation in the lung. This article reviews our institution's clinical experiences in the treatment of lung malignancies with MWA including patient selection, procedural technique, imaging follow-up, treatment outcomes and comparison of ablation techniques.


Assuntos
Técnicas de Ablação , Hipertermia Induzida , Neoplasias Pulmonares/terapia , Micro-Ondas/uso terapêutico , Humanos , Neoplasias Pulmonares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA