Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 118: 103208, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38211462

RESUMO

PURPOSE: Machine learning (ML) models have been demonstrated to be beneficial for optimizing the workload of patient-specific quality assurance (PSQA). Implementing them in clinical routine frequently requires third-party applications beyond the treatment planning system (TPS), slowing down the workflow. To address this issue, a PSQA outcomes predictive model was carefully selected and validated before being fully integrated into the TPS. MATERIALS AND METHODS: Nine ML algorithms were evaluated using cross-validation. The learning database was built by calculating complexity metrics (CM) and binarizing PSQA results into "pass"/"fail" classes for 1767 VMAT arcs. The predictive performance was evaluated using area under the ROC curve (AUROC), sensitivity, and specificity. The ML model was integrated into the TPS via a C# script. Script-guided reoptimization impact on PSQA and dosimetric results was evaluated on ten VMAT plans with "fail"-predicted arcs. Workload reduction potential was also assessed. RESULTS: The selected model exhibited an AUROC of 0.88, with a sensitivity and specificity exceeding 50 % and 90 %, respectively. The script-guided reoptimization of the ten evaluated plans led to an average improvement of 1.4 ± 0.9 percentage points in PSQA results, while preserving the quality of the dose distribution. A yearly savings of about 140 h with the use of the script was estimated. CONCLUSIONS: The proposed script is a valuable complementary tool for PSQA measurement. It was efficiently integrated into the clinical workflow to enhance PSQA outcomes and reduce PSQA workload by decreasing the risk of failing QA and thereby, the need for repeated replanning and measurements.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Garantia da Qualidade dos Cuidados de Saúde/métodos , Aprendizado de Máquina
2.
Phys Med ; 96: 18-31, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35202917

RESUMO

PURPOSE: The aim of this study was to implement a clinically deliverable VMAT planning technique dedicated to advanced breast cancer, and to predict failed QA using a machine learning (ML) model to optimize the QA workload. METHODS: For three planning methods (2A: 2-partial arc, 2AS: 2-partial arc with splitting, 4A: 4-partial arc), dosimetric results were compared with patient-specific QA performed with the electronic portal imaging device of the linac. A dataset was built with the pass/fail status of the plans and complexity metrics. It was divided into training and testing sets. An ML metamodel combining predictions from six base classifiers was trained on the training set to predict plans as 'pass' or 'fail'. The predictive performances were evaluated using the unseen data of the testing set. RESULTS: The dosimetric comparison highlighted that 4A was the highest dosimetric performant method but also the poorest performant in the QA process. 2AS spared the best heart, but provided the highest dose to the contralateral breast and lowest node coverage. 2A provides a dosimetric compromise between organ at risk sparing and PTV coverage with satisfactory QA results. The metamodel had a median predictive sensitivity of 73% and a median specificity of 91%. CONCLUSIONS: The 2A method was selected to calculate clinically deliverable VMAT plans; however, the 2AS method was maintained when the heart was of particular importance and breath-hold techniques were not applicable. The metamodel provides promising predictive performance, and it is intended to be improved as a larger dataset becomes available.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Feminino , Humanos , Órgãos em Risco , Técnicas de Planejamento , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Aprendizado de Máquina Supervisionado
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA