Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 11(9): e006604, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354289

RESUMO

Background Biatrial, extensive, and complex ablation strategies have been published for the treatment of neurally mediated syncope, sinus node dysfunction, and functional atrioventricular block. We have developed a less extensive and more specific approach compared with previously published cardioneuroablation strategies, called cardio-neuromodulation. It is based on tailored vagolysis of the sinoatrial node through partial ablation of the anterior right-ganglionated plexus, preferentially through a right-sided approach. Methods Patients with syncope were enrolled between December 2016 and December 2017. They were assigned to group A if they had a positive head-up tilt test and to group B if they presented with a pause ≥3 seconds. The area to target during cardio-neuromodulation was designed offline on a computed tomographic scan. Slow heart rates and pauses were compared during 24-hour rhythm registration at baseline, at 1-month follow-up, and 6-month follow-up. Syncope burden was assessed before the procedure and at 3- and 6-month follow-up. Results Twenty patients underwent cardio-neuromodulation through a right-sided approach (12 in group A, 8 in group B). The first application of radiofrequency energy led to a P-P interval shortening >120 ms in all 20 patients. After a mean±SD ablation time of 7±4 minutes and mean ablated surface area of 11±6 mm2, the P-P interval shortened by 219±160 ms ( P<0.001). The number of beats <50/min during 24-hour rhythm registration was reduced by a median of 100% at 6-month follow-up ( P<0.001). Syncope burden was reduced by 95% at 6-month follow-up ( P<0.001). Conclusions These data indicate that cardio-neuromodulation, through a right-sided and computed tomographic-guided procedure, is safe, fast, and highly reproducible in preventing inappropriate functional sinus bradycardia and syncope recurrence.


Assuntos
Ablação por Cateter/métodos , Radiografia Intervencionista/métodos , Síndrome do Nó Sinusal/cirurgia , Síncope Vasovagal/etiologia , Tomografia Computadorizada por Raios X , Potenciais de Ação , Adulto , Idoso , Bélgica , Bradicardia/etiologia , Bradicardia/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/fisiopatologia , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatologia , Teste da Mesa Inclinada , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA