Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Niger J Surg ; 23(2): 81-85, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29089729

RESUMO

INTRODUCTION: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography-guided (CT-guided) biopsy, thoracoscopy or video-assisted thoracoscopy, and bronchoscopy. CT-guided percutaneous lung biopsy was first reported in 1976. AIM OF STUDY: The aim of the study is to report our experience with CT-guided transthoracic biopsy. MATERIALS AND METHODS: Patients with clinical and radiological evidence of intrathoracic mass were counseled and consent obtained for the procedure. They were positioned in the gantry, either supine or prone. A scout scan of the entire chest was taken at 5 mm intervals. The procedure was carried out by the consultants and senior registrar. Following visualization of the lesion, its position in terms of depth and distance from the midline was measured with the machine in centimeter to determine the point of insertion of the trucut needle (14-18-G). The presumed site of the lesion was indicated with a metallic object held in place with two to three strips of plasters after cleaning the site with Povidone-iodine. After insertion, repeat scans were performed to confirm that the needle was within the mass. A minimum of 3 core cuts was taken to be certain that the samples were representative. The results were analyzed by the determination of means and percentages. RESULTS: Twenty-six patients underwent this procedure between 2011 and 2015. There were 15 males and 11 females (M:F = 1.4:1). The age range was between 30 and 99 years with a mean of 55 years. Histological diagnosis was obtained in 24 of the patients giving sensitivity of 92.3%. There were 3 mild complications giving a rate of 11.5%. The complications included a case of mild hemoptysis and two patients who had mild pneumothoraces which did not require tube thoracostomy. CONCLUSION: CT-guided biopsy is a reliable procedure for obtaining deep-seated intrathoracic biopsies with high sensitivity and minimal complication rate.

2.
Niger J Surg ; 20(1): 16-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24665196

RESUMO

INTRODUCTION: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or 'holder' of this device specific to their design. AIM: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. MATERIALS AND METHODS: A sheet of iron measuring 1.9 cm (width) × 0.1 cm (thickness) was used to design the holder circular main frame. Another sheet measuring 2 cm (width) × 0.6 cm (thickness) × 24 cm (length) was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O'clock positions. The stem of the T consist of a 0.6 cm (thickness) × 13 cm (length) rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter) made of 0.4 cm iron rod. RESULT: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm). Its advantages include (i) affordability, (ii) materials are locally accessible, (iii) versatility (iv) reproducibility. The disadvantages include, (i) it requires some time to fit, (ii) caution is required in fitting the oxygenator to avoid breakage, (iii) a spanner is required to lock the latch. CONCLUSION: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to meet the unforeseen challenges.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA