Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Thorac Cardiovasc Surg ; 157(1): 234-243.e9, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30557941

RESUMO

OBJECTIVE: To use novel statistical methods for analyzing the effect of lesion set on (long-standing) persistent atrial fibrillation (AF) in the Cardiothoracic Surgical Trials Network trial of surgical ablation during mitral valve surgery (MVS). METHODS: Two hundred sixty such patients were randomized to MVS + surgical ablation or MVS alone. Ablation was randomized between pulmonary vein isolation and biatrial maze. During 12 months postsurgery, 228 patients (88%) submitted 7949 transtelephonic monitoring (TTM) recordings, analyzed for AF, atrial flutter (AFL), or atrial tachycardia (AT). As previously reported, more ablation than MVS-alone patients were free of AF or AF/AFL at 6 and 12 months (63% vs 29%; P < .001) by 72-hour Holter monitoring, without evident difference between lesion sets (for which the trial was underpowered). RESULTS: Estimated freedom from AF/AFL/AT on any transmission trended higher after biatrial maze than pulmonary vein isolation (odds ratio, 2.31; 95% confidence interval, 0.95-5.65; P = .07) 3 to 12 months postsurgery; estimated AF/AFL/AT load (ie, proportion of TTM strips recording AF/AFL/AT) was similar (odds ratio, 0.90; 95% confidence interval, 0.57-1.43; P = .6). Within 12 months, estimated prevalence of AF/AFL/AT by TTM was 58% after MVS alone, and 36% versus 23% after pulmonary vein isolation versus biatrial maze (P < .02). CONCLUSIONS: Statistical modeling using TTM recordings after MVS in patients with (long-standing) persistent AF suggests that a biatrial maze is associated with lower AF/AFL/AT prevalence, but not a lower load, compared with pulmonary vein isolation. The discrepancy between AF/AFL/AT prevalence assessed at 2 time points by Holter monitoring versus weekly TTM suggests the need for a confirmatory trial, reassessment of definitions for failure after ablation, and validation of statistical methods for assessing atrial rhythms longitudinally.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Valva Mitral/cirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Flutter Atrial/etiologia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Prevalência , Telemetria , Resultado do Tratamento
2.
Stat Methods Med Res ; 27(1): 126-141, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-26740575

RESUMO

Atrial fibrillation is an arrhythmic disorder where the electrical signals of the heart become irregular. The probability of atrial fibrillation (binary response) is often time varying in a structured fashion, as is the influence of associated risk factors. A generalized nonlinear mixed effects model is presented to estimate the time-related probability of atrial fibrillation using a temporal decomposition approach to reveal the pattern of the probability of atrial fibrillation and their determinants. This methodology generalizes to patient-specific analysis of longitudinal binary data with possibly time-varying effects of covariates and with different patient-specific random effects influencing different temporal phases. The motivation and application of this model is illustrated using longitudinally measured atrial fibrillation data obtained through weekly trans-telephonic monitoring from an NIH sponsored clinical trial being conducted by the Cardiothoracic Surgery Clinical Trials Network.


Assuntos
Técnicas de Ablação , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Dinâmica não Linear , Humanos , Medição de Risco/estatística & dados numéricos
3.
J Thorac Cardiovasc Surg ; 155(2): 461-469.e4, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29042101

RESUMO

BACKGROUND: Bicuspid aortic valves (BAV) are associated with incompletely characterized aortopathy. Our objectives were to identify distinct patterns of aortopathy using machine-learning methods and characterize their association with valve morphology and patient characteristics. METHODS: We analyzed preoperative 3-dimensional computed tomography reconstructions for 656 patients with BAV undergoing ascending aorta surgery between January 2002 and January 2014. Unsupervised partitioning around medoids was used to cluster aortic dimensions. Group differences were identified using polytomous random forest analysis. RESULTS: Three distinct aneurysm phenotypes were identified: root (n = 83; 13%), with predominant dilatation at sinuses of Valsalva; ascending (n = 364; 55%), with supracoronary enlargement rarely extending past the brachiocephalic artery; and arch (n = 209; 32%), with aortic arch dilatation. The arch phenotype had the greatest association with right-noncoronary cusp fusion: 29%, versus 13% for ascending and 15% for root phenotypes (P < .0001). Severe valve regurgitation was most prevalent in root phenotype (57%), followed by ascending (34%) and arch phenotypes (25%; P < .0001). Aortic stenosis was most prevalent in arch phenotype (62%), followed by ascending (50%) and root phenotypes (28%; P < .0001). Patient age increased as the extent of aneurysm became more distal (root, 49 years; ascending, 53 years; arch, 57 years; P < .0001), and root phenotype was associated with greater male predominance compared with ascending and arch phenotypes (94%, 76%, and 70%, respectively; P < .0001). Phenotypes were visually recognizable with 94% accuracy. CONCLUSIONS: Three distinct phenotypes of bicuspid valve-associated aortopathy were identified using machine-learning methodology. Patient characteristics and valvular dysfunction vary by phenotype, suggesting that the location of aortic pathology may be related to the underlying pathophysiology of this disease.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/anormalidades , Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Diagnóstico por Computador/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Aprendizado de Máquina , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Seio Aórtico/diagnóstico por imagem , Adulto , Idoso , Aorta Torácica/fisiopatologia , Aneurisma Aórtico/classificação , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos Transversais , Feminino , Doenças das Valvas Cardíacas/classificação , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão , Fenótipo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Seio Aórtico/fisiopatologia
4.
Biom J ; 59(2): 331-343, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27983754

RESUMO

Atrial fibrillation (AF) is an abnormal heart rhythm characterized by rapid and irregular heartbeat, with or without perceivable symptoms. In clinical practice, the electrocardiogram (ECG) is often used for diagnosis of AF. Since the AF often arrives as recurrent episodes of varying frequency and duration and only the episodes that occur at the time of ECG can be detected, the AF is often underdiagnosed when a limited number of repeated ECGs are used. In studies evaluating the efficacy of AF ablation surgery, each patient undergoes multiple ECGs and the AF status at the time of ECG is recorded. The objective of this paper is to estimate the marginal proportions of patients with or without AF in a population, which are important measures of the efficacy of the treatment. The underdiagnosis problem is addressed by a three-class mixture regression model in which a patient's probability of having no AF, paroxysmal AF, and permanent AF is modeled by auxiliary baseline covariates in a nested logistic regression. A binomial regression model is specified conditional on a subject being in the paroxysmal AF group. The model parameters are estimated by the Expectation-Maximization (EM) algorithm. These parameters are themselves nuisance parameters for the purpose of this research, but the estimators of the marginal proportions of interest can be expressed as functions of the data and these nuisance parameters and their variances can be estimated by the sandwich method. We examine the performance of the proposed methodology in simulations and two real data applications.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Biometria/métodos , Modelos Logísticos , Fibrilação Atrial/cirurgia , Ablação por Cateter , Simulação por Computador , Eletrocardiografia , Humanos , Prevalência
5.
J Thorac Cardiovasc Surg ; 152(3): 756-761.e5, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27530636

RESUMO

OBJECTIVES: To (1) assess the continuous distribution of the percentage of residual primary cancer in resection specimens after induction therapy for locally advanced esophageal adenocarcinoma, (2) determine the effects of residual primary cancer on survival after esophagectomy, (3) ascertain interplay between residual primary cancer and classical classifications of response to induction therapy (ypTNM), and (4) identify predictors of residual primary cancer. METHODS: From January 2006 to November 2012, 188 patients (78%) underwent accelerated chemoradiotherapy, and 52 patients (22%) underwent chemotherapy alone followed by esophagectomy for adenocarcinoma. Mean age was 61 ± 9.2 years, and 89% were male. Residual primary cancer, assessed as the percentage of residual primary cancer cells in resection specimens, was quantified histologically by a gastrointestinal pathologist. Random Forest technology was used for data analysis. RESULTS: Twenty-five specimens (10%) had no residual primary cancer (ypT0), 79 (33%) had 1% to 25% residual cancer, 91 (38%) had 26% to 75%, and 45 (19%) had >75%. Survival was worse with increasing residual primary cancer, plateauing at 75%. Greater residual primary cancer was associated with worse survival across the spectrum of higher ypTN. Higher ypT, larger number of positive nodes, and use of induction chemotherapy rather than induction chemoradiotherapy were associated with greater residual primary cancer. CONCLUSIONS: Less residual primary cancer in response to preoperative therapy is associated with a linear increase in survival after esophagectomy for locally advanced esophageal adenocarcinoma; however, survival is poorer than for resected early-stage cancers. Therefore, for patients with poor prognostic indicators, including higher percentage of residual primary cancer, the role of adjuvant therapy needs to be further examined in an attempt to improve survival.


Assuntos
Adenocarcinoma/patologia , Adenocarcinoma/terapia , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/terapia , Neoplasia Residual/patologia , Quimiorradioterapia , Terapia Combinada , Esofagectomia , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estadiamento de Neoplasias , Prognóstico , Taxa de Sobrevida
6.
J Thorac Cardiovasc Surg ; 152(3): 773-780.e14, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27215927

RESUMO

OBJECTIVES: Introduction of hybrid techniques, such as transapical transcatheter aortic valve replacement (TA-TAVR), requires skills that a heart team must master to achieve technical efficiency: the technical performance learning curve. To date, the learning curve for TA-TAVR remains unknown. We therefore evaluated the rate at which technical performance improved, assessed change in occurrence of adverse events in relation to technical performance, and determined whether adverse events after TA-TAVR were linked to acquiring technical performance efficiency (the learning curve). METHODS: From April 2007 to February 2012, 1100 patients, average age 85.0 ± 6.4 years, underwent TA-TAVR in the PARTNER-I trial. Learning curves were defined by institution-specific patient sequence number using nonlinear mixed modeling. RESULTS: Mean procedure time decreased from 131 to 116 minutes within 30 cases (P = .06) and device success increased to 90% by case 45 (P = .0007). Within 30 days, 354 patients experienced a major adverse event (stroke in 29, death in 96), with possibly decreased complications over time (P âˆ¼ .08). Although longer procedure time was associated with more adverse events (P < .0001), these events were associated with change in patient risk profile, not the technical performance learning curve (P = .8). CONCLUSIONS: The learning curve for TA-TAVR was 30 to 45 procedures performed, and technical efficiency was achieved without compromising patient safety. Although fewer patients are now undergoing TAVR via nontransfemoral access, understanding TA-TAVR learning curves and their relationship with outcomes is important as the field moves toward next-generation devices, such as those to replace the mitral valve, delivered via the left ventricular apex.


Assuntos
Estenose da Valva Aórtica/cirurgia , Competência Clínica , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/educação , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Duração da Cirurgia , Segurança do Paciente , Complicações Pós-Operatórias , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 87(1): 154-62, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26256280

RESUMO

OBJECTIVES: To assess technical performance learning curves of teams performing transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: TF-TAVR is a new procedure for treating severe aortic stenosis. The number of cases required for procedural efficiency is unknown. METHODS: In the PARTNER-I trial, 1,521 patients underwent TF-TAVR from 4/2007-2/2012. Learning curve analysis of technical performance metrics was performed using institution-specific patient sequence number, interval between procedures, and institutional trial entry date. Learning curve characteristics were assessed using semi-parametric and parametric mixed-effects models. RESULTS: As patient sequence number increased, average procedure time decreased from 154 to 85 minutes (P < 0.0001), and fluoroscopy time from 28 to 20 minutes (P < 0.0001). Procedure time plateaued at an average of 83 minutes (range 52-140). Procedure time plateau was dynamic during the course of the trial, averaging 25 cases (range 21-52) by its end. The later institutions enrolled in the trial, the shorter the initial procedure time. During the trial, percutaneous rather than surgical access increased from 7.9% to 69%. CONCLUSIONS: Technical performance learning curves exist for TF-TAVR; procedural efficiency increased with experience, with concomitant decreases in radiation and contrast media exposure. The number of cases needed to achieve efficiency decreased progressively, with optimal procedural performance reached after approximately 25 cases for late-entering institutions. Knowledge and experience accumulated by early TF-TAVR institutions were disseminated, shortening the learning curve of late-entering institutions. Technological advances resulting from learning during the trial moved the field from initial conservative surgical cut-down to percutaneous access for most patients. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Educação de Pós-Graduação em Medicina/normas , Próteses Valvulares Cardíacas , Curva de Aprendizado , Substituição da Valva Aórtica Transcateter/educação , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral , Humanos , Masculino , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos
8.
J Thorac Cardiovasc Surg ; 150(3): 557-68.e11, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26238287

RESUMO

OBJECTIVES: The study objectives were to (1) compare the safety of high-risk surgical aortic valve replacement in the Placement of Aortic Transcatheter Valves (PARTNER) I trial with Society of Thoracic Surgeons national benchmarks; (2) reference intermediate-term survival to that of the US population; and (3) identify subsets of patients for whom aortic valve replacement may be futile, with no survival benefit compared with therapy without aortic valve replacement. METHODS: From May 2007 to October 2009, 699 patients with high surgical risk, aged 84 ± 6.3 years, were randomized in PARTNER-IA; 313 patients underwent surgical aortic valve replacement. Median follow-up was 2.8 years. Survival for therapy without aortic valve replacement used 181 PARTNER-IB patients. RESULTS: Operative mortality was 10.5% (expected 9.3%), stroke 2.6% (expected 3.5%), renal failure 5.8% (expected 12%), sternal wound infection 0.64% (expected 0.33%), and prolonged length of stay 26% (expected 18%). However, calibration of observed events in this relatively small sample was poor. Survival at 1, 2, 3, and 4 years was 75%, 68%, 57%, and 44%, respectively, lower than 90%, 81%, 73%, and 65%, respectively, in the US population, but higher than 53%, 32%, 21%, and 14%, respectively, in patients without aortic valve replacement. Risk factors for death included smaller body mass index, lower albumin, history of cancer, and prosthesis-patient mismatch. Within this high-risk aortic valve replacement group, only the 8% of patients with the poorest risk profiles had estimated 1-year survival less than that of similar patients treated without aortic valve replacement. CONCLUSIONS: PARTNER selection criteria for surgical aortic valve replacement, with a few caveats, may be more appropriate, realistic indications for surgery than those of the past, reflecting contemporary surgical management of severe aortic stenosis in high-risk patients at experienced sites.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Alocação de Recursos para a Atenção à Saúde , Implante de Prótese de Valva Cardíaca , Seleção de Pacientes , Avaliação de Processos em Cuidados de Saúde , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Benchmarking , Feminino , Alocação de Recursos para a Atenção à Saúde/normas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/normas , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Futilidade Médica , Complicações Pós-Operatórias/mortalidade , Avaliação de Processos em Cuidados de Saúde/normas , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
9.
Ann Thorac Surg ; 100(3): 785-92; discussion 793, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26242213

RESUMO

BACKGROUND: This study describes short-term and mid-term outcomes of nonagenarian patients undergoing transfemoral or transapical transcatheter aortic valve replacement (TAVR) in the Placement of Aortic Transcatheter Valve (PARTNER)-I trial. METHODS: From April 2007 to February 2012, 531 nonagenarians, mean age 93 ± 2.1 years, underwent TAVR with a balloon-expandable prosthesis in the PARTNER-I trial: 329 through transfemoral (TF-TAVR) and 202 transapical (TA-TAVR) access. Clinical events were adjudicated and echocardiographic results analyzed in a core laboratory. Quality of life (QoL) data were obtained up to 1 year post-TAVR. Time-varying all-cause mortality was referenced to that of an age-sex-race-matched US population. RESULTS: For TF-TAVR, post-procedure 30-day stroke risk was 3.6%; major adverse events occurred in 35% of patients; 30-day paravalvular leak was greater than moderate in 1.4%; median post-procedure length of stay (LOS) was 5 days. Thirty-day mortality was 4.0% and 3-year mortality 48% (44% for the matched population). By 6 months, most QoL measures had stabilized at a level considerably better than baseline, with Kansas City Cardiomyopathy Questionnaire (KCCQ) 72 ± 21. For TA-TAVR, post-procedure 30-day stroke risk was 2.0%; major adverse events 32%; 30-day paravalvular leak was greater than moderate in 0.61%; and median post-procedure LOS was 8 days. Thirty-day mortality was 12% and 3-year mortality 54% (42% for the matched population); KCCQ was 73 ± 23. CONCLUSIONS: A TAVR can be performed in nonagenarians with acceptable short- and mid-term outcomes. Although TF- and TA-TAVR outcomes are not directly comparable, TA-TAVR appears to carry a higher risk of early death without a difference in intermediate-term mortality. Age alone should not preclude referral for TAVR in nonagenarians.


Assuntos
Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
Ann Thorac Surg ; 100(5): 1666-73; discussion 1673-4, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26209494

RESUMO

BACKGROUND: Data regarding the risk of aortic dissection in patients with bicuspid aortic valve and large ascending aortic diameter are limited, and appropriate timing of prophylactic ascending aortic replacement lacks consensus. Thus our objectives were to determine the risk of aortic dissection based on initial cross-sectional imaging data and clinical variables and to isolate predictors of aortic intervention in those initially prescribed serial surveillance imaging. METHODS: From January 1995 to January 2014, 1,181 patients with bicuspid aortic valve underwent cross-sectional computed tomography (CT) or magnetic resonance imaging (MRI) to ascertain sinus or tubular ascending aortic diameter greater than or equal to 4.7 cm. Random Forest classification was used to identify risk factors for aortic dissection, and among patients undergoing surveillance, time-related analysis was used to identify risk factors for aortic intervention. RESULTS: Prevalence of type A dissection that was detected by imaging or was found at operation or on follow-up was 5.3% (n = 63). Probability of type A dissection increased gradually at a sinus diameter of 5.0 cm--from 4.1% to 13% at 7.2 cm--and then increased steeply at an ascending aortic diameter of 5.3 cm--from 3.8% to 35% at 8.4 cm--corresponding to a cross-sectional area to height ratio of 10 cm(2)/m for sinuses of Valsalva and 13 cm(2)/m for the tubular ascending aorta. Cross-sectional area to height ratio was the best predictor of type A dissection (area under the curve [AUC] = 0.73). CONCLUSIONS: Early prophylactic ascending aortic replacement in patients with bicuspid aortic valve should be considered at high-volume aortic centers to reduce the high risk of preventable type A dissection in those with aortas larger than approximately 5.0 cm or with a cross-sectional area to height ratio greater than approximately 10 cm(2)/m.


Assuntos
Aneurisma da Aorta Torácica/etiologia , Dissecção Aórtica/etiologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Medição de Risco/métodos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/epidemiologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/epidemiologia , Doença da Válvula Aórtica Bicúspide , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA