Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 78(15): 1541-1549, 2021 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-34620412

RESUMO

The need for a quantitative and operator-independent assessment of coronary microvascular function is increasingly recognized. We propose the theoretical framework of microvascular resistance reserve (MRR) as an index specific for the microvasculature, independent of autoregulation and myocardial mass, and based on operator-independent measurements of absolute values of coronary flow and pressure. In its general form, MRR equals coronary flow reserve (CFR) divided by fractional flow reserve (FFR) corrected for driving pressures. In 30 arteries, pressure, temperature, and flow velocity measurements were obtained simultaneously at baseline (BL), during infusion of saline at 10 mL/min (rest) and 20 mL/min (hyperemia). A strong correlation was found between continuous thermodilution-derived MRR and Doppler MRR (r = 0.88; 95% confidence interval: 0.72-0.93; P < 0.001). MRR was independent from the epicardial resistance, the lower the FFR value, the greater the difference between MRR and CFR. Therefore, MRR is proposed as a specific, quantitative, and operator-independent metric to quantify coronary microvascular dysfunction.


Assuntos
Circulação Coronária , Microcirculação , Idoso , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Termodiluição , Resistência Vascular
2.
J Interv Cardiol ; 2020: 5024971, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33293902

RESUMO

During the last two decades, there has been a sharp increase in both interest and knowledge about the coronary microcirculation. Since these small vessels are not visible by the human eye, physiologic measurements should be used to characterize their function. The invasive methods presently used (coronary flow reserve (CFR) and index of microvascular resistance (IMR)) are operator-dependent and mandate the use of adenosine to induce hyperemia. In recent years, a new thermodilution-based method for measurement of absolute coronary blood flow and microvascular resistance has been proposed and initial procedural problems have been overcome. Presently, the technique is easy to perform using the Rayflow infusion catheter and the Coroventis software. The method is accurate, reproducible, and completely operator-independent. This method has been validated noninvasively against the current golden standard for flow assessment: Positron Emission Tomography-Computed Tomography (PET-CT). In addition, absolute flow and resistance measurements have proved to be safe, both periprocedurally and at long-term follow-up. With an increasing number of studies being performed, this method has great potential for better understanding and quantification of microvascular disease.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Microcirculação , Isquemia Miocárdica/diagnóstico , Termodiluição/métodos , Humanos , Reprodutibilidade dos Testes , Resistência Vascular
3.
J Am Heart Assoc ; 9(9): e015669, 2020 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-32316813

RESUMO

Background This study aimed to investigate longitudinal physiological changes in the recanalized coronary chronic total occlusion (CTO) vessel and its dependent myocardium after successful percutaneous coronary intervention (PCI). Methods and Results In this pilot study, 25 patients scheduled for elective CTO PCI with viable myocardium and angiographically visible collaterals were included. Absolute coronary blood flow and absolute microvascular resistance were measured invasively using continuous thermodilution. Measurements were performed immediately after successful CTO PCI and at short-term follow-up. In a subgroup of patients, physiological measurements were performed at the predominant donor vessel before CTO PCI, immediately afterwards, and at follow-up. Absolute coronary blood flow in the recanalized CTO artery increased from 148±53 mL/min immediately after PCI to 221±77 mL/min at follow-up (P<0.001). In agreement, absolute resistance in the myocardial territory perfused by the CTO artery, decreased from 545±255 Wood units immediately after the procedure to 387±128 Wood units at follow-up (P=0.014). There were no significant changes in the absolute coronary blood flow and resistance in the predominant donor between baseline and follow-up. Positive remodeling of the distal CTO vessel with an increase in lumen diameter was observed. Conclusions After successful CTO PCI, blood flow in the recanalized artery and microvascular function of the dependent myocardium are not immediately normal but recover over time.


Assuntos
Circulação Coronária , Oclusão Coronária/terapia , Vasos Coronários/fisiopatologia , Microcirculação , Intervenção Coronária Percutânea , Resistência Vascular , Idoso , Velocidade do Fluxo Sanguíneo , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Inglaterra , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Projetos Piloto , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA