Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Magn Reson Imaging ; 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38679841

RESUMO

BACKGROUND: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET) can change management in a large fraction of patients with biochemically recurrent prostate cancer (BCR). PURPOSE: To investigate the added value of PET to MRI and CT for this patient group, and to explore whether the choice of the PET paired modality (PET/MRI vs. PET/CT) impacts detection rates and clinical management. STUDY TYPE: Retrospective. SUBJECTS: 41 patients with BCR (median age [range]: 68 [55-78]). FIELD STRENGTH/SEQUENCE: 3T, including T1-weighted gradient echo (GRE), T2-weighted turbo spin echo (TSE) and dynamic contrast-enhanced GRE sequences, diffusion-weighted echo-planar imaging, and a T1-weighted TSE spine sequence. In addition to MRI, [18F]PSMA-1007 PET and low-dose CT were acquired on the same day. ASSESSMENT: Images were reported using a five-point Likert scale by two teams each consisting of a radiologist and a nuclear medicine physician. The radiologist performed a reading using CT and MRI data and a joint reading between radiologist and nuclear medicine physician was performed using MRI, CT, and PET from either PET/MRI or PET/CT. Findings were presented to an oncologist to create intended treatment plans. Intrareader and interreader agreement analysis was performed. STATISTICAL TESTS: McNemar test, Cohen's κ, and intraclass correlation coefficients. A P-value <0.05 was considered significant. RESULTS: 7 patients had positive findings on MRI and CT, 22 patients on joint reading with PET/CT, and 18 patients joint reading with PET/MRI. For overall positivity, interreader agreement was poor for MR and CT (κ = 0.36) and almost perfect with addition of PET (PET/CT κ = 0.85, PET/MRI κ = 0.85). The addition of PET from PET/CT and PET/MRI changed intended treatment in 20 and 18 patients, respectively. Between joint readings, intended treatment was different for eight patients. DATA CONCLUSION: The addition of [18F]PSMA-1007 PET/MRI or PET/CT to MRI and CT may increase detection rates, could reduce interreader variability, and may change intended treatment in half of patients with BCR. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
NMR Biomed ; : e5136, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514929

RESUMO

High acceleration factors in radial magnetic resonance fingerprinting (MRF) of the prostate lead to strong streak-like artefacts from flow in the femoral blood vessels, possibly concealing important anatomical information. Region-optimised virtual (ROVir) coils is a beamforming-based framework to create virtual coils that maximise signal in a region of interest while minimising signal in a region of interference. In this study, the potential of removing femoral flow streak artefacts in prostate MRF using ROVir coils is demonstrated in silico and in vivo. The ROVir framework was applied to radial MRF k-space data in an automated pipeline designed to maximise prostate signal while minimising signal from the femoral vessels. The method was tested in 15 asymptomatic volunteers at 3 T. The presence of streaks was visually assessed and measurements of whole prostate T1, T2 and signal-to-noise ratio (SNR) with and without streak correction were examined. In addition, a purpose-built simulation framework in which blood flow through the femoral vessels can be turned on and off was used to quantitatively evaluate ROVir's ability to suppress streaks in radial prostate MRF. In vivo it was shown that removing selected ROVir coils visibly reduces streak-like artefacts from the femoral blood flow, without increasing the reconstruction time. On average, 80% of the prostate SNR was retained. A similar reduction of streaks was also observed in silico, while the quantitative accuracy of T1 and T2 mapping was retained. In conclusion, ROVir coils efficiently suppress streaking artefacts from blood flow in radial MRF of the prostate, thereby improving the visual clarity of the images, without significant sacrifices to acquisition time, reconstruction time and accuracy of quantitative values. This is expected to help enable T1 and T2 mapping of prostate cancer in clinically viable times, aiding differentiation between prostate cancer from noncancer and healthy prostate tissue.

3.
BJU Int ; 133(3): 278-288, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37607322

RESUMO

OBJECTIVES: To compare the performance of currently available biopsy decision support tools incorporating magnetic resonance imaging (MRI) findings in predicting clinically significant prostate cancer (csPCa). PATIENTS AND METHODS: We retrospectively included men who underwent prostate MRI and subsequent targeted and/or systematic prostate biopsies in two large European centres. Available decision support tools were identified by a PubMed search. Performance was assessed by calibration, discrimination, decision curve analysis (DCA) and numbers of biopsies avoided vs csPCa cases missed, before and after recalibration, at risk thresholds of 5%-20%. RESULTS: A total of 940 men were included, 507 (54%) had csPCa. The median (interquartile range) age, prostate-specific antigen (PSA) level, and PSA density (PSAD) were 68 (63-72) years, 9 (7-15) ng/mL, and 0.20 (0.13-0.32) ng/mL2 , respectively. In all, 18 multivariable risk calculators (MRI-RCs) and dichotomous biopsy decision strategies based on MRI findings and PSAD thresholds were assessed. The Van Leeuwen model and the Rotterdam Prostate Cancer Risk Calculator (RPCRC) had the best discriminative ability (area under the receiver operating characteristic curve 0.86) of the MRI-RCs that could be assessed in the whole cohort. DCA showed the highest clinical utility for the Van Leeuwen model, followed by the RPCRC. At the 10% threshold the Van Leeuwen model would avoid 22% of biopsies, missing 1.8% of csPCa, whilst the RPCRC would avoid 20% of biopsies, missing 2.6% of csPCas. These multivariable models outperformed all dichotomous decision strategies based only on MRI-findings and PSAD. CONCLUSIONS: Even in this high-risk cohort, biopsy decision support tools would avoid many prostate biopsies, whilst missing very few csPCa cases. The Van Leeuwen model had the highest clinical utility, followed by the RPCRC. These multivariable MRI-RCs outperformed and should be favoured over decision strategies based only on MRI and PSAD.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estudos Retrospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Próstata/patologia
4.
Insights Imaging ; 14(1): 157, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37749333

RESUMO

BACKGROUND: Prostate segmentation is an essential step in computer-aided detection and diagnosis systems for prostate cancer. Deep learning (DL)-based methods provide good performance for prostate gland and zones segmentation, but little is known about the impact of manual segmentation (that is, label) selection on their performance. In this work, we investigated these effects by obtaining two different expert label-sets for the PROSTATEx I challenge training dataset (n = 198) and using them, in addition to an in-house dataset (n = 233), to assess the effect on segmentation performance. The automatic segmentation method we used was nnU-Net. RESULTS: The selection of training/testing label-set had a significant (p < 0.001) impact on model performance. Furthermore, it was found that model performance was significantly (p < 0.001) higher when the model was trained and tested with the same label-set. Moreover, the results showed that agreement between automatic segmentations was significantly (p < 0.0001) higher than agreement between manual segmentations and that the models were able to outperform the human label-sets used to train them. CONCLUSIONS: We investigated the impact of label-set selection on the performance of a DL-based prostate segmentation model. We found that the use of different sets of manual prostate gland and zone segmentations has a measurable impact on model performance. Nevertheless, DL-based segmentation appeared to have a greater inter-reader agreement than manual segmentation. More thought should be given to the label-set, with a focus on multicenter manual segmentation and agreement on common procedures. CRITICAL RELEVANCE STATEMENT: Label-set selection significantly impacts the performance of a deep learning-based prostate segmentation model. Models using different label-set showed higher agreement than manual segmentations. KEY POINTS: • Label-set selection has a significant impact on the performance of automatic segmentation models. • Deep learning-based models demonstrated true learning rather than simply mimicking the label-set. • Automatic segmentation appears to have a greater inter-reader agreement than manual segmentation.

5.
Front Oncol ; 13: 1220009, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37692851

RESUMO

Introduction: The five-class Dixon-based PET/MR attenuation correction (AC) model, which adds bone information to the four-class model by registering major bones from a bone atlas, has been shown to be error-prone. In this study, we introduce a novel method of accounting for bone in pelvic PET/MR AC by directly predicting the errors in the PET image space caused by the lack of bone in four-class Dixon-based attenuation correction. Methods: A convolutional neural network was trained to predict the four-class AC error map relative to CT-based attenuation correction. Dixon MR images and the four-class attenuation correction µ-map were used as input to the models. CT and PET/MR examinations for 22 patients ([18F]FDG) were used for training and validation, and 17 patients were used for testing (6 [18F]PSMA-1007 and 11 [68Ga]Ga-PSMA-11). A quantitative analysis of PSMA uptake using voxel- and lesion-based error metrics was used to assess performance. Results: In the voxel-based analysis, the proposed model reduced the median root mean squared percentage error from 12.1% and 8.6% for the four- and five-class Dixon-based AC methods, respectively, to 6.2%. The median absolute percentage error in the maximum standardized uptake value (SUVmax) in bone lesions improved from 20.0% and 7.0% for four- and five-class Dixon-based AC methods to 3.8%. Conclusion: The proposed method reduces the voxel-based error and SUVmax errors in bone lesions when compared to the four- and five-class Dixon-based AC models.

6.
MAGMA ; 36(6): 945-956, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37556085

RESUMO

PURPOSE: To evaluate the reproducibility of radiomics features derived via different pre-processing settings from paired T2-weighted imaging (T2WI) prostate lesions acquired within a short interval, to select the setting that yields the highest number of reproducible features, and to evaluate the impact of disease characteristics (i.e., clinical variables) on features reproducibility. MATERIALS AND METHODS: A dataset of 50 patients imaged using T2WI at 2 consecutive examinations was used. The dataset was pre-processed using 48 different settings. A total of 107 radiomics features were extracted from manual delineations of 74 lesions. The inter-scan reproducibility of each feature was measured using the intra-class correlation coefficient (ICC), with ICC values > 0.75 considered good. Statistical differences were assessed using Mann-Whitney U and Kruskal-Wallis tests. RESULTS: The pre-processing parameters strongly influenced the reproducibility of radiomics features of T2WI prostate lesions. The setting that yielded the highest number of features (25 features) with high reproducibility was the relative discretization with a fixed bin number of 64, no signal intensity normalization, and outlier filtering by excluding outliers. Disease characteristics did not significantly impact the reproducibility of radiomics features. CONCLUSION: The reproducibility of T2WI radiomics features was significantly influenced by pre-processing parameters, but not by disease characteristics. The selected pre-processing setting yielded 25 reproducible features.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Humanos , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Estudos Retrospectivos
7.
J Med Imaging (Bellingham) ; 10(2): 024004, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36895761

RESUMO

Purpose: To bypass manual data preprocessing and optimize deep learning performance, we developed and evaluated CROPro, a tool to standardize automated cropping of prostate magnetic resonance (MR) images. Approach: CROPro enables automatic cropping of MR images regardless of patient health status, image size, prostate volume, or pixel spacing. CROPro can crop foreground pixels from a region of interest (e.g., prostate) with different image sizes, pixel spacing, and sampling strategies. Performance was evaluated in the context of clinically significant prostate cancer (csPCa) classification. Transfer learning was used to train five convolutional neural network (CNN) and five vision transformer (ViT) models using different combinations of cropped image sizes ( 64 × 64 , 128 × 128 , and 256 × 256  pixels2), pixel spacing ( 0.2 × 0.2 , 0.3 × 0.3 , 0.4 × 0.4 , and 0.5 × 0.5 mm 2 ), and sampling strategies (center, random, and stride cropping) over the prostate. T2-weighted MR images ( N = 1475 ) from the online available PI-CAI challenge were used to train ( N = 1033 ), validate ( N = 221 ), and test ( N = 221 ) all models. Results: Among CNNs, SqueezeNet with stride cropping (image size: 128 × 128 , pixel spacing: 0.2 × 0.2 mm 2 ) achieved the best classification performance ( 0.678 ± 0.006 ). Among ViTs, ViT-H/14 with random cropping (image size: 64 × 64 and pixel spacing: 0.5 × 0.5 mm 2 ) achieved the best performance ( 0.756 ± 0.009 ). Model performance depended on the cropped area, with optimal size generally larger with center cropping ( ∼ 40 cm 2 ) than random/stride cropping ( ∼ 10 cm 2 ). Conclusion: We found that csPCa classification performance of CNNs and ViTs depends on the cropping settings. We demonstrated that CROPro is well suited to optimize these settings in a standardized manner, which could improve the overall performance of deep learning models.

8.
BJUI Compass ; 3(5): 344-353, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35950035

RESUMO

Objectives: To recalibrate and validate the European Randomized Study of Screening for Prostate Cancer risk calculators (ERSPC RCs) 3/4 and the magnetic resonance imaging (MRI)-ERSPC-RCs to a contemporary Norwegian setting to reduce upfront prostate multiparametric MRI (mpMRI) and prostate biopsies. Patients and Methods: We retrospectively identified and entered all men who underwent prostate mpMRI and subsequent prostate biopsy between January 2016 and March 2017 in a Norwegian centre into a database. mpMRI was reported using PI-RADS v2.0 and clinically significant prostate cancer (csPCa) defined as Gleason ≥ 3 + 4. Probabilities of csPCa and any prostate cancer (PCa) on biopsy were calculated by the ERSPC RCs 3/4 and the MRI-ERSPC-RC and compared with biopsy results. RCs were then recalibrated to account for differences in prevalence between the development and current cohorts (if indicated), and calibration, discrimination and clinical usefulness assessed. Results: Three hundred and three patients were included. The MRI-ERSPC-RCs were perfectly calibrated to our cohort, although the ERSPC RCs 3/4 needed recalibration. Area under the receiver operating curve (AUC) for the ERSPC RCs 3/4 was 0.82 for the discrimination of csPCa and 0.77 for any PCa. The AUC for the MRI-ERSPC-RCs was 0.89 for csPCa and 0.85 for any PCa. Decision curve analysis showed clear net benefit for both the ERSPC RCs 3/4 (>2% risk of csPCa threshold to biopsy) and for the MRI-ERSPC-RCs (>1% risk of csPCa threshold), with a greater net benefit for the MRI-RCs. Using a >10% risk of csPCa or 20% risk of any PCa threshold for the ERSPC RCs 3/4, 15.5% of mpMRIs could be omitted, missing 0.8% of csPCa. Using the MRI-ERSPC-RCs, 23.4% of biopsies could be omitted with the same threshold, missing 0.8% of csPCa. Conclusion: The ERSPC RCs 3/4 and MRI-ERSPC-RCs can considerably reduce both upfront mpMRI and prostate biopsies with little risk of missing csPCa.

9.
Eur Radiol Exp ; 6(1): 35, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35909214

RESUMO

Artificial intelligence (AI) for prostate magnetic resonance imaging (MRI) is starting to play a clinical role for prostate cancer (PCa) patients. AI-assisted reading is feasible, allowing workflow reduction. A total of 3,369 multi-vendor prostate MRI cases are available in open datasets, acquired from 2003 to 2021 in Europe or USA at 3 T (n = 3,018; 89.6%) or 1.5 T (n = 296; 8.8%), 346 cases scanned with endorectal coil (10.3%), 3,023 (89.7%) with phased-array surface coils; 412 collected for anatomical segmentation tasks, 3,096 for PCa detection/classification; for 2,240 cases lesions delineation is available and 56 cases have matching histopathologic images; for 2,620 cases the PSA level is provided; the total size of all open datasets amounts to approximately 253 GB. Of note, quality of annotations provided per dataset highly differ and attention must be paid when using these datasets (e.g., data overlap). Seven grand challenges and commercial applications from eleven vendors are here considered. Few small studies provided prospective validation. More work is needed, in particular validation on large-scale multi-institutional, well-curated public datasets to test general applicability. Moreover, AI needs to be explored for clinical stages other than detection/characterization (e.g., follow-up, prognosis, interventions, and focal treatment).


Assuntos
Próstata , Neoplasias da Próstata , Inteligência Artificial , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Sensibilidade e Especificidade
10.
MAGMA ; 35(4): 573-585, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35150363

RESUMO

OBJECTIVE: Signal intensity normalization is necessary to reduce heterogeneity in T2-weighted (T2W) magnetic resonance imaging (MRI) for quantitative analysis of multicenter data. AutoRef is an automated dual-reference tissue normalization method that normalizes transversal prostate T2W MRI by creating a pseudo-T2 map. The aim of this study was to evaluate the accuracy of pseudo-T2s and multicenter standardization performance for AutoRef with three pairs of reference tissues: fat/muscle (AutoRefF), femoral head/muscle (AutoRefFH) and pelvic bone/muscle (AutoRefPB). MATERIALS AND METHODS: T2s measured by multi-echo spin echo (MESE) were compared to AutoRef pseudo-T2s in the whole prostate (WP) and zones (PZ and TZ/CZ/AFS) for seven asymptomatic volunteers with a paired Wilcoxon signed-rank test. AutoRef normalization was assessed on T2W images from a multicenter evaluation set of 1186 prostate cancer patients. Performance was measured by inter-patient histogram intersections of voxel intensities in the WP before and after normalization in a selected subset of 80 cases. RESULTS: AutoRefFH pseudo-T2s best approached MESE T2s in the volunteer study, with no significant difference shown (WP: p = 0.30, TZ/CZ/AFS: p = 0.22, PZ: p = 0.69). All three AutoRef versions increased inter-patient histogram intersections in the multicenter dataset, with median histogram intersections of 0.505 (original data), 0.738 (AutoRefFH), 0.739 (AutoRefF) and 0.726 (AutoRefPB). DISCUSSION: All AutoRef versions reduced variation in the multicenter data. AutoRefFH pseudo-T2s were closest to experimentally measured T2s.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Masculino , Pelve , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
11.
PLoS One ; 16(5): e0252387, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34043735

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is essential in the detection and staging of prostate cancer. However, improved tools to distinguish between low-risk and high-risk cancer are needed in order to select the appropriate treatment. PURPOSE: To investigate the diagnostic potential of signal fractions estimated from a two-component model using combined T2- and diffusion-weighted imaging (T2-DWI). MATERIAL AND METHODS: 62 patients with prostate cancer and 14 patients with benign prostatic hyperplasia (BPH) underwent combined T2-DWI (TE = 55 and 73 ms, b-values = 50 and 700 s/mm2) following clinical suspicion of cancer, providing a set of 4 measurements per voxel. Cancer was confirmed in post-MRI biopsy, and regions of interest (ROIs) were delineated based on radiology reporting. Signal fractions of the slow component (SFslow) of the proposed two-component model were calculated from a model fit with 2 free parameters, and compared to conventional bi- and mono-exponential apparent diffusion coefficient (ADC) models. RESULTS: All three models showed a significant difference (p<0.0001) between peripheral zone (PZ) tumor and normal tissue ROIs, but not between non-PZ tumor and BPH ROIs. The area under the receiver operating characteristics curve distinguishing tumor from prostate voxels was 0.956, 0.949 and 0.949 for the two-component, bi-exponential and mono-exponential models, respectively. The corresponding Spearman correlation coefficients between tumor values and Gleason Grade Group were fair (0.370, 0.499 and -0.490), but not significant. CONCLUSION: Signal fraction estimates from a two-component model based on combined T2-DWI can differentiate between tumor and normal prostate tissue and show potential for prostate cancer diagnosis. The model performed similarly to conventional diffusion models.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Hiperplasia Prostática/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Humanos , Masculino
12.
Sci Rep ; 11(1): 2085, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33483545

RESUMO

T2-weighted (T2W) MRI provides high spatial resolution and tissue-specific contrast, but it is predominantly used for qualitative evaluation of prostate anatomy and anomalies. This retrospective multicenter study evaluated the potential of T2W image-derived textural features for quantitative assessment of peripheral zone prostate cancer (PCa) aggressiveness. A standardized preoperative multiparametric MRI was performed on 87 PCa patients across 6 institutions. T2W intensity and apparent diffusion coefficient (ADC) histogram, and T2W textural features were computed from tumor volumes annotated based on whole-mount histology. Spearman correlations were used to evaluate association between textural features and PCa grade groups (i.e. 1-5). Feature utility in differentiating and classifying low-(grade group 1) vs. intermediate/high-(grade group ≥ 2) aggressive cancers was evaluated using Mann-Whitney U-tests, and a support vector machine classifier employing "hold-one-institution-out" cross-validation scheme, respectively. Textural features indicating image homogeneity and disorder/complexity correlated significantly (p < 0.05) with PCa grade groups. In the intermediate/high-aggressive cancers, textural homogeneity and disorder/complexity were significantly lower and higher, respectively, compared to the low-aggressive cancers. The mean classification accuracy across the centers was highest for the combined ADC and T2W intensity-textural features (84%) compared to ADC histogram (75%), T2W histogram (72%), T2W textural (72%) features alone or T2W histogram and texture (77%), T2W and ADC histogram (79%) combined. Texture analysis of T2W images provides quantitative information or features that are associated with peripheral zone PCa aggressiveness and can augment their classification.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Máquina de Vetores de Suporte
13.
MAGMA ; 34(2): 309-321, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32737628

RESUMO

OBJECTIVES: To develop and evaluate an automated method for prostate T2-weighted (T2W) image normalization using dual-reference (fat and muscle) tissue. MATERIALS AND METHODS: Transverse T2W images from the publicly available PROMISE12 (N = 80) and PROSTATEx (N = 202) challenge datasets, and an in-house collected dataset (N = 60) were used. Aggregate channel features object detectors were trained to detect reference fat and muscle tissue regions, which were processed and utilized to normalize the 3D images by linear scaling. Mean prostate pseudo T2 values after normalization were compared to literature values. Inter-patient histogram intersections of voxel intensities in the prostate were compared between our approach, the original images, and other commonly used normalization methods. Healthy vs. malignant tissue classification performance was compared before and after normalization. RESULTS: The prostate pseudo T2 values of the three tested datasets (mean ± standard deviation = 78.49 ± 9.42, 79.69 ± 6.34 and 79.29 ± 6.30 ms) corresponded well to T2 values from literature (80 ± 34 ms). Our normalization approach resulted in significantly higher (p < 0.001) inter-patient histogram intersections (median = 0.746) than the original images (median = 0.417) and most other normalization methods. Healthy vs. malignant classification also improved significantly (p < 0.001) in peripheral (AUC 0.826 vs. 0.769) and transition (AUC 0.743 vs. 0.678) zones. CONCLUSION: An automated dual-reference tissue normalization of T2W images could help improve the quantitative assessment of prostate cancer.


Assuntos
Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Humanos , Masculino , Neoplasias da Próstata
14.
Diagnostics (Basel) ; 10(9)2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-32961895

RESUMO

Computer-aided detection and diagnosis (CAD) systems have the potential to improve robustness and efficiency compared to traditional radiological reading of magnetic resonance imaging (MRI). Fully automated segmentation of the prostate is a crucial step of CAD for prostate cancer, but visual inspection is still required to detect poorly segmented cases. The aim of this work was therefore to establish a fully automated quality control (QC) system for prostate segmentation based on T2-weighted MRI. Four different deep learning-based segmentation methods were used to segment the prostate for 585 patients. First order, shape and textural radiomics features were extracted from the segmented prostate masks. A reference quality score (QS) was calculated for each automated segmentation in comparison to a manual segmentation. A least absolute shrinkage and selection operator (LASSO) was trained and optimized on a randomly assigned training dataset (N = 1756, 439 cases from each segmentation method) to build a generalizable linear regression model based on the radiomics features that best estimated the reference QS. Subsequently, the model was used to estimate the QSs for an independent testing dataset (N = 584, 146 cases from each segmentation method). The mean ± standard deviation absolute error between the estimated and reference QSs was 5.47 ± 6.33 on a scale from 0 to 100. In addition, we found a strong correlation between the estimated and reference QSs (rho = 0.70). In conclusion, we developed an automated QC system that may be helpful for evaluating the quality of automated prostate segmentations.

15.
ACS Nano ; 14(7): 7832-7846, 2020 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-32413260

RESUMO

Although the first nanomedicine was clinically approved more than two decades ago, nanoparticles' (NP) in vivo behavior is complex and the immune system's role in their application remains elusive. At present, only passive-targeting nanoformulations have been clinically approved, while more complicated active-targeting strategies typically fail to advance from the early clinical phase stage. This absence of clinical translation is, among others, due to the very limited understanding for in vivo targeting mechanisms. Dynamic in vivo phenomena such as NPs' real-time targeting kinetics and phagocytes' contribution to active NP targeting remain largely unexplored. To better understand in vivo targeting, monitoring NP accumulation and distribution at complementary levels of spatial and temporal resolution is imperative. Here, we integrate in vivo positron emission tomography/computed tomography imaging with intravital microscopy and flow cytometric analyses to study αvß3-integrin-targeted cyclic arginine-glycine-aspartate decorated liposomes and oil-in-water nanoemulsions in tumor mouse models. We observed that ligand-mediated accumulation in cancerous lesions is multifaceted and identified "NP hitchhiking" with phagocytes to contribute considerably to this intricate process. We anticipate that this understanding can facilitate rational improvement of nanomedicine applications and that immune cell-NP interactions can be harnessed to develop clinically viable nanomedicine-based immunotherapies.


Assuntos
Nanopartículas , Neoplasias , Animais , Integrina alfaV , Integrina alfaVbeta3 , Lipídeos , Camundongos , Neoplasias/tratamento farmacológico , Fagócitos
16.
Front Oncol ; 10: 582092, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33425735

RESUMO

OBJECTIVE: Simultaneous PET/MRI combines soft-tissue contrast of MRI with high molecular sensitivity of PET in one session. The aim of this prospective study was to evaluate detection rates of recurrent prostate cancer by 18F-fluciclovine PET/MRI. METHODS: Patients with biochemical recurrence (BCR) or persistently detectable prostate specific antigen (PSA), were examined with simultaneous 18F-fluciclovine PET/MRI. Multiparametric MRI (mpMRI) and PET/MRI were scored on a 3-point scale (1-negative, 2-equivocal, 3-recurrence/metastasis) and detection rates (number of patients with suspicious findings divided by total number of patients) were reported. Detection rates were further stratified based on PSA level, PSA doubling time (PSAdt), primary treatment and inclusion criteria (PSA persistence, European Association of Urology (EAU) Low-Risk BCR and EAU High-Risk BCR). A detailed investigation of lesions with discrepancy between mpMRI and PET/MRI scores was performed to evaluate the incremental value of PET/MRI to mpMRI. The impact of the added PET acquisition on further follow-up and treatment was evaluated retrospectively. RESULTS: Among patients eligible for analysis (n=84), 54 lesions were detected in 38 patients by either mpMRI or PET/MRI. Detection rates were 41.7% for mpMRI and 39.3% for PET/MRI (score 2 and 3 considered positive). There were no significant differences in detection rates for mpMRI versus PET/MRI. Disease detection rates were higher in patients with PSA≥1ng/mL than in patients with lower PSA levels but did not differ between patients with PSAdt above versus below 6 months. Detection rates in patients with primary radiation therapy were higher than in patients with primary surgery. Patients categorized as EAU Low-Risk BCR had a detection rate of 0% both for mpMRI and PET/MRI. For 15 lesions (27.8% of all lesions) there was a discrepancy between mpMRI score and PET/MRI score. Of these, 10 lesions scored as 2-equivocal by mpMRI were changed to a more definite score (n=4 score 1 and n=6 score 3) based on the added PET acquisition. Furthermore, for 4 of 10 patients with discrepancy between mpMRI and PET/MRI scores, the added PET acquisition had affected the treatment choice. CONCLUSION: Combined 18F-fluciclovine PET/MRI can detect lesions suspicious for recurrent prostate cancer in patients with a range of PSA levels. Combined PET/MRI may be useful to select patients for appropriate treatment, but is of limited use at low PSA values or in patients classified as EAU Low-Risk BCR, and the clinical value of 18F-fluciclovine PET/MRI in this study was too low to justify routine clinical use.

17.
J Magn Reson Imaging ; 51(6): 1900-1910, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31794113

RESUMO

BACKGROUND: Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion-weighted magnetic resonance imaging (MRI) with 3 b values. PURPOSE: To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis. STUDY TYPE: Prospective. POPULATION: Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa. SEQUENCE: 3T T2 - and diffusion-weighted MRI with b values: b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm2 (values in brackets were only used for patients). ASSESSMENT: Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy-confirmed cancer and healthy tissue, and between true and false positive radiological findings. STATISTICAL TESTS: Within-subject coefficient of variation (WCV) to assess repeatability and receiver-operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED. RESULTS: The repeatability was acceptable (WCV = 0.2-0.3) for all intermediate b values tested, apart from b = 50 s/mm2 (WCV = 0.3-0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150-250 s/mm2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false-positive findings and true-positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77). DATA CONCLUSION: RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150-250 s/mm2 minimizes the influence of noise and maximizes repeatability. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1900-1910.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata , Biópsia , Humanos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Sensibilidade e Especificidade
18.
PET Clin ; 14(4): 487-498, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31472746
19.
Front Oncol ; 8: 516, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30498693

RESUMO

Purpose: To investigate the associations of metabolite levels derived from magnetic resonance spectroscopic imaging (MRSI) and 18F-fluciclovine positron emission tomography (PET) with prostate tissue characteristics. Methods: In a cohort of 19 high-risk prostate cancer patients that underwent simultaneous PET/MRI, we evaluated the diagnostic performance of MRSI and PET for discrimination of aggressive cancer lesions from healthy tissue and benign lesions. Data analysis comprised calculations of correlations of mean standardized uptake values (SUVmean), maximum SUV (SUVmax), and the MRSI-derived ratio of (total choline + spermine + creatine) to citrate (CSC/C). Whole-mount histopathology was used as gold standard. Results: The results showed a moderate significant correlation between both SUVmean and SUVmax with CSC/C ratio. Conclusions: We demonstrated that the simultaneous acquisition of 18F-fluciclovine PET and MRSI with an integrated PET/MRI system is feasible and a combination of these imaging modalities has potential to improve the diagnostic sensitivity and specificity of prostate cancer lesions.

20.
J Nucl Med ; 59(12): 1913-1917, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29728516

RESUMO

The objective of this study was to evaluate the effect of including bone in Dixon-based attenuation correction for 18F-fluciclovine PET/MRI of primary and recurrent prostate cancer. Methods:18F-fluciclovine PET data from 2 PET/MRI studies-one for staging of high-risk prostate cancer (28 patients) and one for diagnosis of recurrent prostate cancer (81 patients)-were reconstructed with a 4-compartment (reference) and 5-compartment attenuation map. In the latter, continuous linear attenuation coefficients for bone were included by coregistration with an atlas. The SUVmax and mean 50% isocontour SUV (SUViso) of primary, locally recurrent, and metastatic lesions were compared between the 2 reconstruction methods using linear mixed-effects models. In addition, mean SUVs were obtained from bone marrow in the third lumbar vertebra (L3) to investigate the effect of including bone attenuation on lesion-to-bone marrow SUV ratios (SUVRmax and SUVRiso; recurrence study only). The 5-compartment attenuation maps were visually compared with the in-phase Dixon MR images for evaluation of bone registration errors near the lesions. P values of less than 0.05 were considered significant. Results: Sixty-two lesions from 39 patients were evaluated. Bone registration errors were found near 19 (31%) of these lesions. In the remaining 8 primary prostate tumors, 7 locally recurrent lesions, and 28 lymph node metastases without bone registration errors, use of the 5-compartment attenuation map was associated with small but significant increases in SUVmax (2.5%; 95% confidence interval [CI], 2.0%-3.0%; P < 0.001) and SUViso (2.5%; 95% CI, 1.9%-3.0%; P < 0.001), but not SUVRmax (0.2%; 95% CI, -0.5%-0.9%; P = 0.604) and SUVRiso (0.2%; 95% CI -0.6%-1.0%; P = 0.581), in comparison to the 4-compartment attenuation map. Conclusion: The investigated method for atlas-based inclusion of bone in 18F-fluciclovine PET/MRI attenuation correction has only a small effect on the SUVs of soft-tissue prostate cancer lesions, and no effect on their lesion-to-bone marrow SUVRs when using signal from L3 as a reference. The attenuation maps should always be checked for registration artifacts for lesions in or close to the bones.


Assuntos
Osso e Ossos/diagnóstico por imagem , Ácidos Carboxílicos , Ciclobutanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Estudos de Coortes , Radioisótopos de Flúor , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Imagem Multimodal/métodos , Imagem Multimodal/estatística & dados numéricos , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Compostos Radiofarmacêuticos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA