Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Transpl Int ; 37: 12445, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962472

RESUMO

While allograft rejection (AR) continues to threaten the success of cardiothoracic transplantation, lack of accurate and repeatable surveillance tools to diagnose AR is a major unmet need in the clinical management of cardiothoracic transplant recipients. Endomyocardial biopsy (EMB) and transbronchial biopsy (TBBx) have been the cornerstone of rejection monitoring since the field's incipience, but both suffer from significant limitations, including poor concordance of biopsy interpretation among pathologists. In recent years, novel molecular tools for AR monitoring have emerged and their performance characteristics have been evaluated in multiple studies. An international working group convened by ESOT has reviewed the existing literature and provides a series of recommendations to guide the use of these biomarkers in clinical practice. While acknowledging some caveats, the group recognized that Gene-expression profiling and donor-derived cell-free DNA (dd-cfDNA) may be used to rule out rejection in heart transplant recipients, but they are not recommended for cardiac allograft vasculopathy screening. Other traditional biomarkers (NT-proBNP, BNP or troponin) do not have sufficient evidence to support their use to diagnose AR. Regarding lung transplant, dd-cfDNA could be used to rule out clinical rejection and infection, but its use to monitor treatment response is not recommended.


Assuntos
Biomarcadores , Rejeição de Enxerto , Transplante de Coração , Transplante de Pulmão , Humanos , Rejeição de Enxerto/diagnóstico , Biomarcadores/sangue , Transplante de Pulmão/efeitos adversos , Consenso , Ácidos Nucleicos Livres/sangue , Biópsia , Europa (Continente) , Sociedades Médicas , Perfilação da Expressão Gênica
2.
Sci Rep ; 14(1): 12212, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806571

RESUMO

A positive family history is a major independent risk factor for atherosclerosis, and genetic variation is an important aspect of cardiovascular disease research. We identified a heterozygous missense variant p.L245P in the MMP10 gene in two families with premature myocardial infarction using whole-exome sequencing. The aim of this study was to investigate the consequences of this variant using in-silico and functional in-vitro assays. Molecular dynamics simulations were used to analyze protein interactions, calculate free binding energy, and measure the volume of the substrate-binding cleft of MMP10-TIMP1 models. The p.L245P variant showed an altered protein surface, different intra- and intermolecular interactions of MMP10-TIMP1, a lower total free binding energy between MMP10-TIMP1, and a volume-minimized substrate-binding cleft of MMP10 compared to the wild-type. For the functional assays, human THP-1 cells were transfected with plasmids containing MMP10 cDNA carrying the p.L245P and wild-type variant and differentiated into macrophages. Macrophage adhesion and migration assays were then conducted, and pro-inflammatory chemokine levels were evaluated. The p.L245P variant led to macrophages that were more adherent, less migratory, and secreted higher levels of the pro-inflammatory chemokines CXCL1 and CXCL8 than wild-type macrophages. Thus, the p.L245P variant in MMP10 may influence the pathogenesis of atherosclerosis in families with premature myocardial infarction by altering protein - protein interactions, macrophage adhesion and migration, and expression of pro-inflammatory chemokines, which may increase plaque rupture. These results could contribute to the development of selective MMP10 inhibitors and reduce the risk of atherosclerosis in families with a history of premature myocardial infarction.


Assuntos
Metaloproteinase 10 da Matriz , Mutação de Sentido Incorreto , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/genética , Metaloproteinase 10 da Matriz/genética , Metaloproteinase 10 da Matriz/metabolismo , Masculino , Feminino , Linhagem , Adulto , Simulação de Dinâmica Molecular , Macrófagos/metabolismo , Células THP-1 , Pessoa de Meia-Idade , Sequenciamento do Exoma , Movimento Celular/genética , Predisposição Genética para Doença , Adesão Celular/genética , Inibidor Tecidual de Metaloproteinase-1
3.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479833

RESUMO

OBJECTIVES: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material. METHODS: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit). The conduits were designed according to the Ozaki method. Their hydrodynamic performance (effective orifice area, mean pressure gradient and leakage volume) were evaluated in a mock circulation loop at different hydrodynamic conditions. RESULTS: Hydrodynamic assessment showed significantly larger effective orifice area of PEPE and PEPR compared to PRPR under all conditions and there were no significant differences between PEPE and PEPR [for condition 2: PEPE 2.43 (2.35-2.54) cm2, PEPR: 2.42 (2.4-2.5) cm2, PRPR: 2.08 (1.97-2.21) cm2, adjusted pairwise comparisons: PEPE versus PEPR: P = 0.80, PEPE versus PRPR: P < 0.001, PEPR versus PRPR: P < 0.001]. Mean pressure gradient was significantly lower for PEPE and PEPR compared with PRPR, whereas no significant differences were seen between PEPE and PEPR. Leakage volume was significantly lower for PEPE and PEPR compared with PRPR under all conditions while leakage was similar between PEPE and PEPR. CONCLUSIONS: Pulmonary graft reconstruction with pericardium cusps showed superior hydrodynamic performance compared with polytetrafluoroethylene cusps. Our results suggest that it could be considered as an alternative substitute for right ventricular outflow tract replacement during the Ross procedure.


Assuntos
Próteses Valvulares Cardíacas , Obstrução do Fluxo Ventricular Externo , Humanos , Polietilenotereftalatos , Prótese Vascular , Desenho de Prótese , Obstrução do Fluxo Ventricular Externo/cirurgia , Politetrafluoretileno , Resultado do Tratamento , Estudos Retrospectivos
4.
Ann Thorac Surg ; 117(3): 517-525, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37625612

RESUMO

BACKGROUND: Aortic valve (AV) repair is an evolving surgical strategy in the treatment of nonelderly adults with aortic regurgitation. We aimed to determine the 1-year outcome after AV repair vs surgical AV replacement (sAVR) using real-world data from the German Aortic Valve Registry. METHODS: A total of 8076 aortic regurgitation patients (mean age, 59.1 ± 15.0 years; 76% men; mean The Society of Thoracic Surgeons score, 1.3 ± 1.1), who underwent AV surgical procedures between 2011 and 2015, were identified from German Aortic Valve Registry. The AV was repaired in 2327 patients (29%), and the remaining 5749 patients (71%) underwent sAVR. A weighted propensity score model, including the variables of age, sex, and The Society of Thoracic Surgeons score, was used to correct for baseline differences between AV repair and sAVR cohorts. The primary end point was 1-year survival after AV repair vs sAVR. Secondary end points were freedom from cardiac events and AV reinterventions. RESULTS: Survival at 1 year was 97.7% (95% CI, 97.0%-98.5%) in the AV repair cohort vs 96.4% (95% CI, 95.9%-96.9%) in the propensity score-weighted sAVR cohort (log-rank P < .001). Cox regression revealed a significant advantage of AV repair vs sAVR (hazard ratio, 0.68; 95% CI, 0.51-0.90; P < .0001) on 1-year survival, which was independent of age. Cardiac event-free survival at 1 year was 85.7% (95% CI, 483.8%-87.7%) in the AV repair group vs 81.7% (95% CI, 80.7%-82.9%) in the sAVR group (log-rank P < .001). AV reintervention was required in 38 AV repair patients (1.6%) compared with 1.6% in the sAVR cohort (P = .59). CONCLUSIONS: AV repair surgery, whenever intraoperatively feasible, is associated with a significantly better 1-year survival and 1-year cardiac event-free survival compared with sAVR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
5.
Sci Rep ; 13(1): 15340, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37714924

RESUMO

Pressure recovery (PR) is essential part of the post stenotic fluid mechanics and depends on the ratio of EOA/AA, the effective aortic valve orifice area (EOA) and aortic cross-sectional area (AA). In patients with advanced ascending aortic aneurysm and mildly diseased aortic valves, the effect of AA on pressure recovery and corresponding functional aortic valve opening area (ELCO) was evaluated before and after valve-sparing surgery (Dacron graft implantation). 66 Patients with ascending aortic aneurysm (mean aortic diameter 57 +/- 10 mm) and aortic valve-sparing surgery (32 reimplantation technique (David), 34 remodeling technique (Yacoub)) were routinely investigated by Doppler echocardiography. Dacron graft with a diameter between 26 and 34 mm were implanted. EOA was significantly declined after surgery (3.4 +/- 0.8 vs. 2.6 +/- 0.9cm2; p < 0.001). Insertion of Dacron prosthesis resulted in a significant reduction of AA (26.7 +/- 10.2 vs. 6.8 +/- 1.1cm2; p < 0.001) with increased ratio of EOA/AA (0.14 +/- 0.05 vs. 0.40 +/- 0.1; p < 0.001) and pressure recovery index (PRI; 0.24 +/- 0.08 vs. 0.44 +/- 0.06; p < 0.0001). Despite reduction of EOA, ELCO (= EOA corrected for PR) increased from 4.0 +/- 1.1 to 5.0 +/- 3.1cm2 (p < 0.01) with reduction in transvalvular LV stroke work (1005 +/- 814 to 351 +/- 407 mmHg × ml, p < 0.001) after surgery. These effects were significantly better in patients with Yacoub technique than with the David operation. The hemodynamic findings demonstrate a valve-vessel interaction almost entirely caused by a marked reduction in the ascending AA with significant PR gain. The greater hemodynamic benefit of the Yacoub technique due to higher EOA values compared to the David technique was evident and may be of clinical relevance.


Assuntos
Aorta Torácica , Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Polietilenotereftalatos , Catéteres , Aorta/diagnóstico por imagem , Aorta/cirurgia
6.
Eur J Cardiothorac Surg ; 64(4)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37773993

RESUMO

OBJECTIVES: Transcatheter heart valves (THVs) are investigated according to International Organization for Standardization requirements using in vitro heart simulators to evaluate hydrodynamic performance. In contrast to surgical valves, a THV's performance heavily depends on the configuration and shape of the aortic anulus. In International Organization for Standardization regulations, there is no detailed definition for the construction of a compartment in which a THV has to be tested. Therefore, the aim of this in vitro study was to compare different in vitro models for functional testing of THVs. METHODS: Porcine aortic conduits (23-mm diameter) were implanted in Dacron prostheses and calcified with double-distilled water and calcification buffer at 37°C over 83 million cycles in a Hi-Cycler (durability testing) mimicking nearly 3 patient-years. Hydrodynamic testing of Evolut PRO 26 mm was performed within 3 models (plexiglass, native conduit and calcified conduit; all 23-mm diameter) at a frequency of 64 bpm and different stroke volumes (55-105 ml). RESULTS: Calcified conduits showed significantly higher mean pressure gradients (MPG) and lower effective orifice areas (EOA) in comparison to native conduits (without THV; P < 0.001). EOA and MPG of Evolut PRO differed depending on the model tested. Calcified conduits resulted in the lowest EOA and highest MPG of the THV compared to plexiglass and the native conduit. Full expansion of the THV was least impaired in the native conduit, while lowest geometric orifice area, lowest minimal internal diameter and highest pin-wheeling index of Evolut PRO were seen in the calcified conduit. CONCLUSIONS: Full expansion and functional performance of the Evolut PRO THV depends on the configuration of the testing compartment in an in vitro setting.

7.
Echocardiography ; 40(10): 1058-1067, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37638407

RESUMO

BACKGROUND: The importance of pulmonary artery pressure recovery (PR) in patients with Ross procedures in whom a homograft substitutes the resected pulmonary valve, is unknown. The aim of the study was to evaluate the occurrence and extent of PR in the pulmonary artery in 65 asymptomatic patients with pulmonary homograft after Ross surgery during rest and exercise. METHODS: Stress echocardiography was performed in 65 pulmonary homograft patients and 31 controls with native pulmonary valves up to 75 W. Right ventricular systolic pressure (RVSP), transvalvular flow, mean pressure gradient (Pmean ), valve resistance, and RV stroke work were determined in the exercise (max. 75 W) and recovery phases in increments of 25 W each. RESULTS: Pulmonary homografts demonstrated significantly elevated Pmean compared to controls at all stages. When considering pressure recovery (absolute and relative PR at rest 3.8 ± 1.8 mm Hg, 42.6 ± 7.2%, respectively) and transvalvular energy loss (EL; at rest 4.5 ± 4.3 mm Hg) the homograft hemodynamics reached the level of controls. In a subgroup of patients with tricuspid regurgitation, resting RVSP was the same in homograft patients and controls (21.3 ± 6.1 vs. 20.4 ± 6.3, p = .62), despite significant different Pmax values. CONCLUSIONS: Ross patients with pulmonary homograft showed systematically increased hemodynamic parameters compared to normal pulmonary valves. These differences were abolished when PR was considered for homograft patients. The equality of RVSP values at rest in both groups shows non-invasive evidence for PR in the pulmonary system after homograft implantation. Therefore, PR appears to be an important measure in calculating the actual hemodynamics in pulmonary homografts.

8.
Radiat Oncol ; 18(1): 88, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37217934

RESUMO

BACKGROUND: In stereotactic radiotherapy, dose is prescribed to an isodose surrounding the planning target volume (PTV). However, the desired dose inhomogeneity inside the PTV leaves the specific dose distribution to the gross tumor volume (GTV) unspecified. A simultaneously integrated boost (SIB) to the GTV could solve this shortcoming. In a retrospective planning study with 20 unresected brain metastases, a SIB approach was tested against the classical prescription. METHODS: For all metastases, the GTV was isotropically enlarged by 3 mm to a PTV. Two plans were generated, one according to the classical 80% concept with 5 times 7 Gy prescribed (on D2%) to the 80% PTV surrounding isodose (with D98%(PTV) ≥ 35 Gy), and the other one following a SIB concept with 5 times 8.5 Gy average GTV dose and with D98%(PTV) ≥ 35 Gy as additional requirement. Plan pairs were compared in terms of homogeneity inside GTV, high dose in PTV rim around GTV, and dose conformity and gradients around PTV using Wilcoxon matched pairs signed rank test. RESULTS: The SIB concept was superior to the classical 80% concept concerning dose homogeneity inside GTV: Heterogeneity index of GTV was in the SIB concept (median 0.0513, range 0.0397-0.0757) significantly (p = 0.001) lower than in the 80% concept (median 0.0894, range 0.0447-0.1872). Dose gradients around PTV were not inferior. The other examined measures were comparable. CONCLUSION: Our stereotactic SIB concept better defines the dose distribution inside PTV and can be considered for clinical use.


Assuntos
Neoplasias Encefálicas , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Estudos de Viabilidade , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário
9.
Zentralbl Chir ; 148(3): 284-292, 2023 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-36167311

RESUMO

In recent years, the use of mechanical support for patients with cardiac or circulatory failure has continuously increased, leading to 3,000 ECLS/ECMO (extracorporeal life support/extracorporeal membrane oxygenation) implantations annually in Germany. Due to the lack of guidelines, there is an urgent need for evidence-based recommendations addressing the central aspects of ECLS/ECMO therapy. In July 2015, the generation of a guideline level S3 according to the standards of the Association of the Scientific Medical Societies in Germany (AWMF) was announced by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS). In a well-structured consensus process, involving experts from Germany, Austria and Switzerland, delegated by 16 scientific societies and the patients' representation, the guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" was created under guidance of the GSTCVS, and published in February 2021. The guideline focuses on clinical aspects of initiation, continuation, weaning and aftercare, herein also addressing structural and economic issues. This article presents an overview on the methodology as well as the final recommendations.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Humanos , Sociedades Científicas , Circulação Extracorpórea , Sociedades Médicas , Alemanha
10.
Physiol Rep ; 10(23): e15432, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36511522

RESUMO

Relevant pressure recovery (PR) has been shown to increase functional stenotic aortic valve orifice area and reduce left ventricular load. However, little is known about the relevance of PR in the pulmonary artery. The study examined the impact of PR using 2D-echocardiography in the pulmonary artery distal to the degenerated homograft in patients after Ross surgery. Ninety-two patients with pulmonary homograft were investigated by Doppler echocardiography (mean time interval after surgery 31 ± 26 months). PR was measured as a function of pulmonary artery diameter determined by computed tomography angiography. Homograft orifice area, valve resistance, and transvalvular stroke work were calculated with and without considering PR. PR decreased as the pulmonary artery diameter increased (r = -0.69, p < 0.001). Mean PR was 41.5 ± 7.1% of the Doppler-derived pressure gradient (Pmax ), which resulted in a markedly increased homograft orifice area (energy loss coefficient index [ELCOI] vs. effective orifice area index [EOAI], 1.3 ± 0.4 cm2 /m2 vs. 0.9 ± 0.4 cm2 /m2 , p < 0.001). PR significantly reduced homograft resistance and transvalvular stroke work (822 ± 433 vs. 349 ± 220 mmHg × ml, p < 0.0001). When PR was considered, the correlations of the parameters used were significantly better, and 11 of 18 patients (61%) in the group with severe homograft stenosis (EOAI <0.6 cm2 /m2 ) could be reclassified as moderate stenosis. Our results showed that the Doppler measurements overestimated the degree of homograft stenosis and thus the right ventricular load, when PR was neglected in the pulmonary artery. Therefore, Doppler measurements that ignore PR can misclassify homograft stenosis and may lead to premature surgery.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Humanos , Constrição Patológica , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler
11.
Clin Res Cardiol ; 111(12): 1387-1395, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36074270

RESUMO

OBJECTIVE: We compared TAVI vs. SAVR in patients with moderate-to-severe chronic kidney disease (eGFR 15-60 ml/min/1.73 m2) for whom both procedures could possibly be considered (age ≤ 80 years, STS-score 4-8). BACKGROUND: According to both ACC/AHA and ESC/EACTS recent guidelines, aortic stenosis may be treated with either transcatheter (TAVI) or surgical (SAVR) aortic valve replacement in a subgroup of patients. A shared therapeutic decision is made by a heart team based on individual factors, including chronic kidney disease (CKD). METHODS: Data from the large nationwide German Aortic Valve Registry were used. A propensity score method was used to select 704 TAVI and 374 SAVR matched patients. Primary endpoint was 1-year survival. Secondary endpoints were clinical complications, including pacemaker implantation, vascular complications, myocardial infarction, bleeding, and the need for new-onset dialysis. RESULTS: One-year survival was similar (HR [95% CI] for TAVI 1.271 [0.795, 2.031], p = 0.316), with no divergence in Kaplan-Meier curves. In spite of post-procedural short-term survival being numerically higher for TAVI patients and 1-year survival being numerically higher for SAVR patients, such differences did not reach statistical significance (96.4% vs. 94.2%, p = 0.199, and 86.2% vs. 81.2%, p = 0.316, respectively). In weighted analyses, pacemaker implantation, vascular complications, and were significantly more common with TAVI; whereas myocardial infarction, bleeding requiring transfusion, and longer ICU-stay and overall hospitalization were higher with SAVR. Temporary dialysis was more common with SAVR (p < 0.0001); however, a probable need for chronic dialysis was rare and similar in both groups. CONCLUSION: Both TAVI and SAVR led to comparable and excellent results in patients with moderate-to-severe CKD in an intermediate-risk population of patients with symptomatic severe aortic stenosis for whom both therapies could possibly be considered.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Infarto do Miocárdio , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fatores de Risco , Sistema de Registros , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Infarto do Miocárdio/etiologia , Resultado do Tratamento
12.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35993864

RESUMO

OBJECTIVES: Selection of a surgical aortic valve (SAV) bioprosthesis model for the treatment of aortic valve disease remains controversial. The aim of this study was to characterize the functional performance of 8 SAV models in a standardized in vitro setting. METHODS: The hydrodynamic performance of 8 SAVs with labelled size 21 mm (Avalus™, Hancock® II, Mosaic® Ultra™, Perimount®, Perimount® Magna Ease, Epic™ Supra, Trifecta™ GT; Freestyle®), was investigated in a pulse duplicator. Transvalvular pressure gradients and effective orifice area (EOA) were recorded. The geometrical orifice area and physical dimensions of the valves were determined, and new functional dimensions were introduced. RESULTS: Mean pressure gradient (MPG) and EOA differed significantly between the analysed SAVs. The Epic presented with the lowest EOA and highest MPG, while the Trifecta showed the highest EOA and the lowest MPG. We introduce a useful way to determine the minimal internal diameter and a new measure termed 'relative orifice area' to characterize a valve's performance. CONCLUSIONS: SAVs showed significant differences in their hydrodynamic performance despite the same label size. This finding was related to the construction of the valves. We introduce a new measure that characterizes the functional performance of a valve model and size for the treatment of an aortic annulus of a specific size. Our data emphasize that SAV selection should carefully be done using an individual patient approach and that future research is necessary to improve the current generation of SAVs.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Desempenho Físico Funcional , Desenho de Prótese
13.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35962722

RESUMO

OBJECTIVES: Aortic valve (AV) repair is an evolving surgical strategy in the treatment of young patients with aortic regurgitation (AR) and/or aortic root aneurysm. We aimed to determine the clinical outcome following AV repair/AV-sparing root surgery using real-world data from the German Aortic Valve Registry. METHODS: A total of 2327 patients with AR (mean age 55.2 ± 15.0 years, 76% men), who underwent AV repair/AV-sparing root surgery between 2011 and 2015 (i.e. 5% of 42 868 AV surgery patients enrolled in the German Aortic Valve Registry during the same period) were included. Study cohort was subdivided according to the technique of AV repair: isolated AV repair without root surgery (group I) (n = 914), AV-sparing root surgery (i.e. reimplantation or remodelling) without cusp repair (group II) (n = 1077) and AV-sparing root surgery (i.e. reimplantation or remodelling) with simultaneous cusp repair (group III) (n = 336). Primary end point was 1-year survival after AV repair/AV-sparing root surgery. Secondary end points were freedom from cardiac adverse events and freedom from AV reinterventions at 1-year follow-up. RESULTS: Thirty-day mortality was 19 (0.8%) in the whole study cohort without significant differences in the 3 subgroups [4 (0.4%) patients in group I vs 14 (1.3%) patients in group II vs 1 (0.3%) patient in group III (P = 0.054)]. Postoperatively, 1445 (74%) patients had no residual AR, 474 (24%) patients had mild AR and 40 (2%) patients had moderate/severe AR at the time of hospital discharge. One-year survival (95% confidence interval) was 97.7% (97.1-98.3) in the whole study cohort and without significant difference among the 3 subgroups. One-year cardiac adverse event-free survival (95% confidence interval) was 85.7% (84.2-87.1) and was similar in all 3 study groups in propensity score-weighted analysis. A total of 38 (1.6%) patients required AV reintervention during a 1-year follow-up, without significant difference among subgroups (P = 0.11). CONCLUSIONS: AV repair/AV-sparing root surgery is performed in 5% of patients requiring AV surgery in Germany. Our data demonstrate very satisfactory periprocedural and 1-year survival and cardiac event-free survival after AV repair surgery. Implementation of specific surgical techniques during the index procedure seems to result in comparable outcomes.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Adulto , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-35895002

RESUMO

OBJECTIVES: We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study. METHODS: Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St. Jude Medical Masters. All prosthetic valves had a labelled size of 21 mm. RESULTS: The Ozaki valve and native aortic valve showed a similar and significantly larger orifice area than all investigated prosthetic valves particularly at high flow rates. There was no significant difference between the Ozaki valve and the native aortic valve. The native aortic valve and Ozaki valve showed a similar increase in orifice area with increasing flow through the valve while prosthetic valves showed a markedly weaker increase. Similarly, the native and Ozaki valve showed a similar increase in mPG with forward flow which was weaker than prosthetic valves. Cusp kinematics were similar between the native and Ozaki valve, whilst prosthetic valves were clearly distinguishable from them. CONCLUSIONS: The Ozaki procedure showed excellent hydrodynamic performance compared to prosthetic valves and showed similar cusp motion characteristics to the native aortic valve. Our results suggest that the Ozaki neocuspidized valve behaves physiologically in many aspects, which may contribute to beneficial clinical outcomes.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Valva Aórtica/cirurgia , Hemodinâmica , Hidrodinâmica , Desenho de Prótese , Suínos
15.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35567484

RESUMO

OBJECTIVES: The aim of this study was to analyse the outcome of patients between 50 and 69 years of age undergoing biological or mechanical aortic valve replacement. METHODS: Data were collected from the German Aortic Valve Registry. Data were analysed regarding baseline characteristics and outcome parameters such as 5-year survival, stroke and reintervention. RESULTS: In total.3046 patients undergoing isolated surgical aortic valve replacement between 2011 and 2012 were investigated and a propensity score matching was performed. Within this period, 2239 patients received a biological prostheses, while 807 patients received a mechanical prosthesis. Mean age in the biological group was 63.07 (±5.11) and 57.34 (±4.67) in the mechanical group (standardized mean difference 1.172). In the overall cohort, there were more female patients in the biological group (32.7% vs 28.4%) and log EuroSCORE I was higher (5.41% vs 4.26%). After propensity matching (610 pairs), there was no difference in the mortality at 5-year follow-up (12.1% biological vs 9.2% mechanical P = 0.05) nor for reoperation/reintervention (2.5% biological vs 2.0% mechanical, P = 0.546). Patients undergoing mechanical aortic valve replacement suffered from a higher stroke rate 3.3% vs 1.5% (P = 0.04) at 5-year follow-up. CONCLUSIONS: Aortic valve replacement with biological or mechanical prostheses showed similar 5-year outcomes for survival and reoperation in a propensity-matched cohort, but significantly increased stroke rate after mechanical aortic valve replacement. This could influence the choice of a mechanical valve in younger patients.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Idoso , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
16.
Transpl Immunol ; 73: 101608, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35490983

RESUMO

BACKGROUND: The major obstacle for long-term survival after successful lung transplantation is the development of bronchiolitis obliterans (BO) which is one phenotype of chronic lung allograft dysfunction (CLAD). Nintedanib has beneficial effects treating neoplastic diseases and idiopathic pulmonary fibrosis by blocking tyrosine kinase receptors. These receptors play an important role in alloimmune-mediated proliferative diseases. The aim of this study was to determine the effect of nintedanib on proliferative airway changes after orthotopic trachea transplantation in mice. METHODS: C57BL/6 mice (H-2b) donor tracheas were orthotopically transplanted into CBA/J mice (H-2k). After transplantation, recipients were daily treated with nintedanib (60 mg/kg; p.o.). Histological and immunofluorescence analysis were performed after 30 days and intragraft gene expression measurements after 14 days of treatment, respectively. RESULTS: Tracheal allografts from mice treated with nintedanib showed significantly less features of chronic rejection than untreated allografts reflected in a higher epithelium/lamina propria ratio (ELR) [ELR: 0.65 ± 0.13 nintedanib vs. 0.50 ± 0.07 untreated controls; p < 0.05] and a reduced submucosal smooth muscle actin (SMA) content [SMA: 1.26% ± 0.78% nintedanib vs. 2.18% ± 1.01% untreated controls; p < 0.01]. Furthermore, lower T cell, macrophage and dendritic cell infiltration was detected in the nintedanib treated grafts. The protein and intragraft mRNA expression of receptor subtypes was considerably decreased in grafts of nintedanib treated mice. The mRNA expression of relevant immune mediators was affected by nintedanib treatment. CONCLUSION: Receptor blocking by nintedanib reduced alloimmune-induced inflammation and chronic airway changes in mouse trachea allografts and might be a promising approach to diminish the development of BO in lung transplants.


Assuntos
Bronquiolite Obliterante , Doença Enxerto-Hospedeiro , Aloenxertos , Animais , Bronquiolite Obliterante/tratamento farmacológico , Bronquiolite Obliterante/patologia , Modelos Animais de Doenças , Rejeição de Enxerto/tratamento farmacológico , Doença Enxerto-Hospedeiro/patologia , Indóis , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , RNA Mensageiro , Traqueia/transplante
17.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35380636

RESUMO

OBJECTIVES: Surgical aortic valve replacement (SAVR) in small annuli carries an elevated risk for the patient-prosthesis mismatch. In this study, we systematically investigated the influence of different implantation techniques including annular enlargement (AE) on the functional result after SAVR in small annuli using a standardized ex vivo model. METHODS: SAVR using the PERIMOUNT Magna Ease® (PME) 21 mm was performed in small porcine aortic roots using 4 implantation techniques: non-everting pledgeted (NE) suture, single interrupted (SI) suture, continuous suture (CS), figure-of-8 (F8) suture, as well as the PME 23 mm after AE using the Nunez method and the NE suture technique (PME23 AE). The effective orifice area (EOA), mean pressure gradient and leakage volume were evaluated using a mock circulation loop in accordance with ISO regulations. RESULTS: Experiments were conducted on 31 porcine aortic roots. PME21 using F8 and PME23 after AE achieved a significantly larger EOA than using NE. PME23 after AE showed a larger EOA than the PME21 using any suture technique, except the F8 [for stroke volume of 74 ml: PME21 NE: 1.68 (1.63-1.72) cm2, PME21 SI: 1.76 (1.68-1.81) cm2 (P = 0.17), PME21 CS: 1.76 (1.65-1.79) cm2 (P = 0.14), PME21 F8: 1.81 (1.70-1.85) cm2 (P = 0.005); PME23 AE: 1.83 (1.73-1.92) cm2 (P < 0.001)]. SI and CS did not result in larger EOA compared with the NE technique. PME21 using SI had a significantly larger leakage volume than using NE and there was no significant difference between other techniques [for stroke volume of 74 ml: PME21 NE: 3.51 (1.85-4.53) ml/stroke, PME21 SI: 6.00 (4.02-7.06) ml/stroke (P < 0.001), PME21 CS: 4.04 (3.60-4.49) ml/stroke (P = 0.10), PME21 F8: 3.16 (1.99-3.62) ml/stroke (P = 0.74), PME23 NE: 2.89 (2.45-4.72) ml/stroke (P = 0.51)]. CONCLUSIONS: The F8 technique with the PME21 achieved a similar EOA as the 1 size larger PME23 using NE after AE. These results suggest that the F8 technique may be an effective surgical modification to improve the haemodynamic result in a small annulus without additional AE.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Animais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Desenho de Prótese , Técnicas de Sutura , Suínos
18.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-35333318

RESUMO

OBJECTIVES: Transcatheter aortic valve-in-valve (ViV) procedures are increasingly performed for the treatment of degenerated surgical aortic valves with a high risk for a redo operation. For an optimal functional result, precise positioning of the transcatheter heart valve (THV) inside the SHV is crucial. The aim of this study was to systematically investigate the impact of implantation depth on the functional result after a ViV procedure in a standardized in vitro setting. METHODS: A THV 23 mm (Evolut PRO) and 3 SHV 21 mm (Perimount Magna Ease, Trifecta and Hancock II) were used for hydrodynamic testing with a constant heartbeat 64/min and a range of 55-105 ml of stroke volume in 5 different positions of the THV. The following parameters were analysed: mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area, minimal internal diameter and pin-wheeling index. RESULTS: MPG and EOA differed significantly regarding the position of the THV in the same SHV. The highest EOA and the lowest MPG were recorded for Evolut PRO with significance for both parameters in Hancock II at 4 vs 5 mm (P < 0.001), in Magna Ease at 2 mm (vs 3 mm and vs 6 mm, P < 0.001) and in Trifecta at 4 mm (vs 5 and 6 mm, P < 0.001). Leaflet coadaptation, minimal internal diameter and maximal geometric orifice area of the same TAV differ regarding the position of the TAV. CONCLUSIONS: The optimal position for hydrodynamic performance of the THV as ViV differs among specific SHV models. The findings may be useful for planning a ViV procedure using the Evolut PRO THV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Hidrodinâmica , Desenho de Prótese , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
20.
Anaesthesist ; 70(11): 942-950, 2021 11.
Artigo em Alemão | MEDLINE | ID: mdl-34665266

RESUMO

In Germany, a remarkable increase regarding the usage of extracorporeal membrane oxygenation (ECMO) and extracorporeal life support (ECLS) systems has been observed in recent years with approximately 3000 ECLS/ECMO implantations annually since 2015. Despite the widespread use of ECLS/ECMO, evidence-based recommendations or guidelines are still lacking regarding indications, contraindications, limitations and management of ECMO/ECLS patients. Therefore in 2015, the German Society of Thoracic and Cardiovascular Surgery (GSTCVS) registered the multidisciplinary S3 guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" to develop evidence-based recommendations for ECMO/ECLS systems according to the requirements of the Association of the Scientific Medical Societies in Germany (AWMF). Although the clinical application of ECMO/ECLS represents the main focus, the presented guideline also addresses structural and economic issues. Experts from 17 German, Austrian and Swiss scientific societies and a patients' organization, guided by the GSTCVS, completed the project in February 2021. In this report, we present a summary of the methodological concept and tables displaying the recommendations for each chapter of the guideline.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque , Circulação Extracorpórea , Alemanha , Humanos , Sistemas de Manutenção da Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA