Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 38(7): 1484-1491, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38631929

RESUMO

OBJECTIVE: To investigate the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and the mini invasive pulse-power device LiDCOrapid as compared to thermodilution cardiac output (TDCO) as measured by pulmonary artery catheter when assessing cardiac index (CIx) in the setting of elective open abdominal aortic (AA) surgery. DESIGN: A prospective method-comparison study. SETTING: Oulu University Hospital, Finland. PARTICIPANTS: Forty patients undergoing elective open abdominal aortic surgery. INTERVENTIONS: Intraoperative CI measurements were obtained simultaneously with TDCO and the study monitors, resulting in 627 measurement pairs with Starling SV and 497 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS: The Bland-Altman method was used to investigate the agreement among the devices, and four-quadrant plots with error grids were used to assess trending ability. The agreement between TDCO and Starling SV was associated with a bias of 0.18 L/min/m2 (95% confidence interval [CI] = 0.13 to 0.23), wide limits of agreement (LOA = -1.12 to 1.47 L/min/m2), and a percentage error (PE) of 63.7 (95% CI = 52.4-71.0). The agreement between TDCO and LiDCOrapid was associated with a bias of -0.15 L/min/m2 (95% CI = -0.21 to -0.09), wide LOA (-1.56 to 1.37), and a PE of 68.7 (95% CI = 54.9-79.6). The trending ability of neither device was sufficient. CONCLUSION: The CI measurements achieved with Starling SV and LiDCOrapid were not interchangeable with TDCO, and the ability to track changes in CI was poor. These results do not support the use of either study device in monitoring CI during open AA surgery.


Assuntos
Aorta Abdominal , Débito Cardíaco , Monitorização Intraoperatória , Termodiluição , Humanos , Masculino , Feminino , Estudos Prospectivos , Débito Cardíaco/fisiologia , Idoso , Aorta Abdominal/cirurgia , Reprodutibilidade dos Testes , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Pessoa de Meia-Idade , Termodiluição/métodos , Procedimentos Cirúrgicos Vasculares/métodos
2.
J Cardiothorac Vasc Anesth ; 38(2): 423-429, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38114371

RESUMO

OBJECTIVES: The aim of the study was to determine if unresponsive mixed venous oxygen saturation (SvO2) values during early postoperative hours are associated with postoperative organ dysfunction. DESIGN: A single-center retrospective observational study. SETTING: A university hospital. PARTICIPANTS: A total of 6,282 adult patients requiring cardiac surgery who underwent surgery in a University Hospital from 2007 to 2020. INTERVENTIONS: A pulmonary artery catheter was used to gather SvO2 samples after surgery at admission to the intensive care unit (ICU) and 4 hours later. For the analysis, patients were divided into 4 groups according to their SvO2 values. The rate of organ dysfunctions categorized according to the SOFA score was then studied among these subgroups. MEASUREMENTS AND MAIN RESULTS: The crude mortality rate for the cohort at 1 year was 4.3%. Multiple organ dysfunction syndrome (MODS) was present in 33.0% of patients in the early postoperative phase. During the 4-hour initial treatment period, 43% of the 931 patients with low SvO2 on admission responded to goal-directed therapy to increase SvO2 >60%; whereas, in 57% of the 931 patients, the low SvO2 was sustained. According to the adjusted logistic regression analyses, the odds ratio for MODS (4.23 [95% CI 3.41-5.25]), renal- replacement therapy (4.97 [95% CI 3.28-7.52]), time on a ventilator (2.34 [95% CI 2.17-2.52]), and vasoactive-inotropic score >30 (3.62 [95% CI 2.96-4.43]) were the highest in the group with sustained low SvO2. CONCLUSIONS: Patients with SvO2 <60% at ICU admission and 4 hours later had the greatest risk of postoperative MODS. Responsiveness to a goal-directed therapy protocol targeting maintaining or increasing SvO2 ≥60% at and after ICU admission may be beneficial.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigênio , Adulto , Humanos , Estudos Retrospectivos , Insuficiência de Múltiplos Órgãos/diagnóstico , Insuficiência de Múltiplos Órgãos/epidemiologia , Insuficiência de Múltiplos Órgãos/etiologia , Saturação de Oxigênio , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Unidades de Terapia Intensiva
3.
Acta Anaesthesiol Scand ; 67(5): 599-605, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36740457

RESUMO

To determine whether changes in transcranial near-infrared spectroscopy (NIRS) values reflect changes in cardiac index (CI) in adult cardiac surgical patients. Single-center prospective post hoc analysis. University hospital. One hundred and twenty-four adult patients undergoing cardiac surgery. In each patient, several CI measurements were taken, and NIRS values were collected simultaneously. We used a hierarchical linear regression model to assess the association between NIRS values and CI. We calculated a crude model with NIRS as the only factor included, and an adjusted model, where mean arterial pressure, end-tidal CO2 , and oxygen saturation were used as confounding factors. A total of 1301 pairs of NIRS and CI values were collected. The analysis of separate NIRS and CI pairs revealed a poor association, which was not statistically significant when adjusted with the chosen confounders. However, when the changes in NIRS from baseline or from the previous measurement were compared to those of CI, a clinically and statistically significant association between NIRS and CI was observed also in the adjusted model. Compared to the baseline and to the previous measurement, respectively, the regression coefficients with 95% confidence intervals were 0.048 (0.041-0.056) and 0.064 (0.055-0.073) in off-pump coronary artery bypass patients and 0.022 (0.016-0.029) and 0.026 (0.020-0.033) in patients who underwent cardiopulmonary bypass. In an unselected cardiac surgical population, the changes in NIRS values reflect those in CI, especially in off-pump coronary artery bypass patients. In this single-center post hoc analysis of data from a prospectively collected database of cardiac surgery patients, paired measurements of cardiac output and NIRS revealed that while there was a no correlation between individual paired measurements, a small correlation was found in changes in the two measurements from baseline values. This highlights a potential to utilize changes in NIRS from baseline to suggest changes in cardiac output in cardiac surgical populations.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Humanos , Estudos Prospectivos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Monitorização Intraoperatória/métodos , Pressão Arterial , Ponte Cardiopulmonar/métodos , Oxigênio
4.
BMC Anesthesiol ; 23(1): 38, 2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36721097

RESUMO

PURPOSE: Various malignancies with peritoneal carcinomatosis are treated with cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC). The hemodynamic instability resulting from fluid balance alterations during the procedure necessitates reliable hemodynamic monitoring. The aim of the study was to compare the accuracy, precision and trending ability of two less invasive hemodynamic monitors, bioreactance-based Starling SV and pulse power device LiDCOrapid with bolus thermodilution technique with pulmonary artery catheter in the setting of cytoreductive surgery with HIPEC. METHODS: Thirty-one patients scheduled for cytoreductive surgery were recruited. Twenty-three of them proceeded to HIPEC and were included to the study. Altogether 439 and 430 intraoperative bolus thermodilution injections were compared to simultaneous cardiac index readings obtained with Starling SV and LiDCOrapid, respectively. Bland-Altman method, four-quadrant plots and error grids were used to assess the agreement of the devices. RESULTS: Comparing Starling SV with bolus thermodilution, the bias was acceptable (0.13 l min- 1 m- 2, 95% CI 0.05 to 0.20), but the limits of agreement were wide (- 1.55 to 1.71 l min- 1 m- 2) and the percentage error was high (60.0%). Comparing LiDCOrapid with bolus thermodilution, the bias was acceptable (- 0.26 l min- 1 m- 2, 95% CI - 0.34 to - 0.18), but the limits of agreement were wide (- 1.99 to 1.39 l min- 1 m- 2) and the percentage error was high (57.1%). Trending ability was inadequate with both devices. CONCLUSION: Starling SV and LiDCOrapid were not interchangeable with bolus thermodilution technique limiting their usefulness in the setting of cytoreductive surgery with HIPEC.


Assuntos
Líquidos Corporais , Procedimentos Cirúrgicos de Citorredução , Humanos , Quimioterapia Intraperitoneal Hipertérmica , Reprodutibilidade dos Testes , Abdome
5.
BMC Anesthesiol ; 22(1): 322, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261783

RESUMO

BACKGROUND: Low postoperative mixed venous oxygen saturation (SvO2) values have been linked to poor outcomes after cardiac surgery. The present study was designed to assess whether SvO2 values of < 60% at intensive care unit (ICU) admission and 4 h after admission are associated with increased mortality after cardiac surgery. METHODS: During the years 2007-2020, 7046 patients (74.4% male; median age, 68 years [interquartile range, 60-74]) underwent cardiac surgery at an academic medical center in Finland. All patients were monitored with a pulmonary artery catheter. SvO2 values were obtained at ICU admission and 4 h later. Patients were divided into four groups for analyses: SvO2 ≥ 60% at ICU admission and 4 h later; SvO2 ≥ 60% at admission but < 60% at 4 h; SvO2 < 60% at admission but ≥ 60% at 4 h; and SvO2 < 60% at both ICU admission and 4 h later. Kaplan-Meier survival curves, Cox regression models, and receiver operating characteristic curve analysis were used to assess differences among groups in 30-day and 1-year mortality. RESULTS: In the overall cohort, 52.9% underwent coronary artery bypass grafting (CABG), 29.1% valvular surgery, 12.1% combined CABG and valvular procedures, 3.5% surgery of the ascending aorta or aortic dissection, and 2.4% other cardiac surgery. The 1-year crude mortality was 4.3%. The best outcomes were associated with SvO2 ≥ 60% at both ICU admission and 4 h later. Hazard ratios for 1-year mortality were highest among patients with SvO2 < 60% at both ICU admission and 4 h later, regardless of surgical subgroup. CONCLUSION: SvO2 values < 60% at ICU admission and 4 h after admission are associated with increased 30-day and 1-year mortality after cardiac surgery. Goal-directed therapy protocols targeting SvO2 ≥ 60% may be beneficial. Prospective studies are needed to confirm these observational findings.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Saturação de Oxigênio , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Oxigênio , Unidades de Terapia Intensiva
6.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2446-2453, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35027295

RESUMO

OBJECTIVES: Less-invasive and continuous cardiac output monitors recently have been developed to monitor patient hemodynamics. The aim of this study was to compare the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and miniinvasive pulse-power device LiDCOrapid to bolus thermodilution technique with a pulmonary artery catheter (TDCO) when measuring cardiac index in the setting of cardiac surgery with cardiopulmonary bypass (CPB). DESIGN: A prospective method-comparison study. SETTING: Oulu University Hospital, Finland. PARTICIPANTS: Twenty patients undergoing cardiac surgery with CPB. INTERVENTIONS: Cardiac index measurements were obtained simultaneously with TDCO intraoperatively and postoperatively, resulting in 498 measurements with Starling SV and 444 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS: The authors used the Bland-Altman method to investigate the agreement between the devices and four-quadrant plots with error grids to assess the trending ability. The agreement between TDCO and Starling SV was qualified with a bias of 0.43 L/min/m2 (95% confidence interval [CI], 0.37-0.50), wide limits of agreement (LOA, -1.07 to 1.94 L/min/m2), and a percentage error (PE) of 66.3%. The agreement between TDCO and LiDCOrapid was qualified, with a bias of 0.22 L/min/m2 (95% CI 0.16-0.27), wide LOA (-0.93 to 1.43), and a PE of 53.2%. With both devices, trending ability was insufficient. CONCLUSION: The reliability of bioreactance-based Starling SV and pulse-power analyzer LiDCOrapid was not interchangeable with TDCO, thus limiting their usefulness in cardiac surgery with CPB.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Termodiluição , Débito Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar , Humanos , Reprodutibilidade dos Testes , Termodiluição/métodos
7.
J Cardiothorac Vasc Anesth ; 36(7): 1995-2001, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34593310

RESUMO

OBJECTIVE: To determine whether central venous oxygen saturation (ScvO2) measurements could be used interchangeably with mixed venous oxygen saturation (SvO2) measurements in adult cardiac surgery patients. DESIGN: A single-center prospective observational study. SETTING: A university hospital. PARTICIPANTS: Eighty-five adult patients undergoing cardiac surgery. INTERVENTIONS: The study authors compared the oxygen saturations in 590 pairs of venous blood samples drawn from the pulmonary artery catheter (PAC) at three different time points during surgery and four different time points in the intensive care unit. They compared samples obtained from the distal pulmonary artery line (SvO2) to those drawn from the proximal central venous line of the PAC (ScvO2) with the Bland-Altman test and the four-quadrant method. MEASUREMENTS AND MAIN RESULTS: The mean bias between SvO2 and ScvO2 was -1.9 (95% confidence interval [CI], -2.3 to -1.5) and the limits of agreement (LOA) were -11.5 to 7.6 (95% CI, -12.5 to -10.7 and 6.8-8.5, respectively). The percentage error (PE) was 13.2%. Based on the four-quadrant plot, only 50% of the measurement pairs were in agreement, indicating deficient trending ability. CONCLUSION: ScvO2 values showed acceptable accuracy as the mean bias was low. The precision was inadequate; although the PE was acceptable, the LOA were wide. Trending ability was inadequate. The authors cannot recommend the use of ScvO2 values interchangeably with SvO2 measurements in the management of adult cardiac surgery patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Saturação de Oxigênio , Adulto , Humanos , Oximetria , Oxigênio , Troca Gasosa Pulmonar
8.
J Clin Monit Comput ; 36(3): 879-888, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34037919

RESUMO

The pulmonary artery catheter (PAC) is considered the gold standard for cardiac index monitoring. Recently new and less invasive methods to assess cardiac performance have been developed. The aim of our study was to assess the reliability of a non-invasive monitor utilizing bioreactance (Starling SV) and a non-calibrated mini-invasive pulse contour device (FloTrac/EV1000, fourth-generation software) compared to bolus thermodilution technique with PAC (TDCO) during off-pump coronary artery bypass surgery (OPCAB). In this prospective study, 579 simultaneous intra- and postoperative cardiac index measurements obtained with Starling SV, FloTrac/EV1000 and TDCO were compared in 20 patients undergoing OPCAB. The agreement of data was investigated by Bland-Altman plots, while trending ability was assessed by four-quadrant plots with error grids. In comparison with TDCO, Starling SV was associated with a bias of 0.13 L min-1 m-2 (95% confidence interval, 95% CI, 0.07 to 0.18), wide limits of agreement (LOA, - 1.23 to 1.51 L min-1 m-2), a percentage error (PE) of 60.7%, and poor trending ability. In comparison with TDCO, FloTrac was associated with a bias of 0.01 L min-1 m-2 (95% CI - 0.05 to 0.06), wide LOA (- 1.27 to 1.29 L min-1 m-2), a PE of 56.8% and poor trending ability. Both Starling SV and fourth-generation FloTrac showed acceptable mean bias but imprecision due to wide LOA and high PE, and poor trending ability. These findings indicate limited reliability in monitoring cardiac index in patients undergoing OPCAB.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Termodiluição , Débito Cardíaco , Humanos , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Termodiluição/métodos
9.
J Cardiothorac Vasc Anesth ; 36(7): 2031-2034, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34130893

RESUMO

Coagulation factor XII (FXII) is a plasma serine protease that belongs to the contact activation complex responsible for initiating the intrinsic coagulation pathway. FXII deficiency is a rare congenital disorder that is not associated with an increased tendency for bleeding. However, as contact activation is impaired in FXII deficiency, both the celite- and kaolin-initiated activated clotting time (ACT) measurements are prolonged markedly, which poses a challenge for anticoagulation monitoring in patients undergoing cardiac surgery. The authors successfully have used the standard Hemochron Jr. ACT+ test, which is activated by silica and phospholipid in addition to kaolin, to monitor anticoagulation for cardiopulmonary bypass in two patients with severe FXII deficiency. The ACT+ test showed low baseline values, increased adequately in response to heparin, and decreased to baseline after protamine. Importantly, there was no abnormal intra- or postoperative bleeding nor any thrombotic complications. Furthermore, in vitro dose-response ACT+ testing of FXII-deficient blood with increasing heparin concentrations supports the use of ACT+ in FXII deficiency.


Assuntos
Deficiência do Fator XII , Heparina , Anticoagulantes , Ponte Cardiopulmonar , Deficiência do Fator XII/complicações , Deficiência do Fator XII/diagnóstico , Deficiência do Fator XII/cirurgia , Humanos , Caulim , Sistemas Automatizados de Assistência Junto ao Leito , Tempo de Coagulação do Sangue Total
10.
Int J Hyperthermia ; 37(1): 293-300, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32208777

RESUMO

Background and Objectives: Postoperative thromboembolism is a significant cause of prolonged recovery in patients undergoing cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC). Thromboelastography (TEG) can detect hypercoagulable states and predict thromboembolic complications after surgery. This study assessed the impact of CRS and HIPEC on TEG values.Methods: TEG parameters reaction time (R), kinetics time (K), angle (α), maximum amplitude (MA), and lysis percent at 60 min (LY60) were determined preoperatively, and at the end of CRS, during HIPEC, and at the end of the operation using blood samples from 15 HIPEC patients. Platelets, P-TT, and aPTT were also determined before and after CRS.Results: A total of 75 samples were analyzed. During CRS, there was a significant reduction in the mean MA (3.06 mm, p = 0.001). The mean P-TT declined by 32% (p < 0.001) and mean platelets by 55 × 109/L (p < 0.001). During HIPEC, the mean R and K shortened by 1.04 min (p = 0.015) and 0.18 min (p = 0.018), respectively, whereas α increased by 2.48° (p = 0.005).Conclusions: During CRS, both TEG and conventional laboratory tests indicated hypocoagulation. During HIPEC, however, the initiation of coagulation and the kinetics of thrombin formation were accelerated.


Assuntos
Coagulação Sanguínea/fisiologia , Hipertermia Induzida/métodos , Assistência Perioperatória/métodos , Tromboelastografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
11.
Obes Surg ; 28(12): 3943-3949, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30083792

RESUMO

PURPOSE: Obesity causes a prothrombotic state and is known as a predisposing factor for thromboembolic events. In this pilot study, we assessed the impact of surgery for obesity and the subsequent weight loss on blood coagulation using traditional coagulation tests and thromboelastography (TEG). MATERIAL AND METHODS: We studied blood samples from 18 patients receiving bariatric surgery. Besides traditional blood coagulation tests and high-sensitivity C-reactive protein (hsCRP) as a marker of inflammation, the TEG parameters reaction time (R), kinetics time (K), angle (α), maximum amplitude (MA), clot strength (G), and lysis percent at 60 min (LY60) were determined preoperatively and on the first postoperative day and 6 months after surgery. RESULTS: Altogether, 54 samples were analyzed. The median MA (71.3 mm), G (12,403.3 d/sc), and hsCRP (3.5 mg/l) were elevated preoperatively. The median hsCRP further increased on the first day postoperatively, but declined to the normal range 6 months after surgery, while MA and G remained elevated. In traditional coagulation tests, there was an increase in median fibrinogen and D-dimer postoperatively. D-dimer normalized (0.4 mg/l) during the study period, while the fibrinogen level (4.1 g/l) remained above the upper limit of normal. CONCLUSIONS: Measured by TEG, patients receiving bariatric surgery have hemostatic abnormalities indicating hypercoagulation at the 6-month follow-up visit, suggesting an elevated risk for thromboembolic events for at least 6 months after surgery.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Trombofilia/etiologia , Adulto , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio , Fibrinogênio , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/sangue , Projetos Piloto , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/diagnóstico , Tromboelastografia , Trombofilia/sangue , Trombofilia/diagnóstico , Fatores de Tempo
12.
Ann Ital Chir ; 86(3): 258-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26227348

RESUMO

Postoperative stroke after cardiac surgery is often a lethal complication. Herein, we report on a patient who suffered space-occupying ischemic stroke after surgical treatment of type A aortic dissection. He underwent decompressive hemicraniectomy and, despite residual hemianopsia and left side flaccid hemiplegia, survived surgery and was discharged for rehabilitation. This observation suggests that early consultation with a neurosurgeon, intracranial pressure monitoring and, when indicated, decompressive hemicraniectomy should be considered in order to reduce the high mortality rate associated with ischemic stroke after cardiac surgery.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Craniectomia Descompressiva , Acidente Vascular Cerebral/cirurgia , Humanos , Masculino
13.
Basic Clin Pharmacol Toxicol ; 117(3): 156-63, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25626156

RESUMO

Fentanyl is used for pain treatment during pregnancy in human beings and animals. However, fentanyl pharmacokinetics during pregnancy has not been fully established. The aim of this study was to characterize fentanyl pharmacokinetics in pregnant sheep after intravenous and transdermal dosing during surgical procedure performed to ewe and foetus. Pharmacokinetic parameters reported for non-pregnant sheep and nominal transdermal dose rate were utilized for a priori calculation to achieve analgesic fentanyl concentration (0.5-2 ng/ml) in maternal plasma. A total of 20 Aland landrace ewes at 118-127 gestational days were used. In the first protocol, 1 week before surgery, 10 animals received 2 µg/kg fentanyl intravenous bolus, and on the operation day, transdermal fentanyl patches at nominal dose rate of 2 µg/kg/hr were applied to antebrachium, and ewes were then given a 2 µg/kg intravenous bolus followed by an intra-operative 2.5 µg/kg/hr infusion. In the second protocol, 10 animals received fentanyl only as transdermal patches on the operation day and oxycodone for rescue analgesia. The data were analysed with population pharmacokinetic modelling. Intra- and post-operative fentanyl concentrations were similar and slightly lower than the a priori predictions, and elimination and distribution clearances appeared slower during than before or after the surgery. Transdermal patches provided sustained fentanyl absorption for up to 5 days, but the absorption rate was slower than the nominal dose rate and showed a high interindividual variability. Further research is warranted to evaluate the clinical relevance of the observations made in sheep.


Assuntos
Fentanila/farmacocinética , Administração Cutânea , Animais , Relação Dose-Resposta a Droga , Feminino , Fentanila/administração & dosagem , Fentanila/sangue , Infusões Intravenosas , Injeções Intravenosas , Gravidez , Ovinos
14.
Scand Cardiovasc J ; 45(4): 236-46, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21495910

RESUMO

OBJECTIVES: Previous studies have suggested that gastrointestinal integrity is compromised after cardiopulmonary bypass (CPB). We compared the effects of prolonged minimized (MCPB) and conventional CPB (CCPB) on intestinal mucosal integrity by determining mucosal damage, epithelial cell proliferation rate and distribution of tight junction proteins in a porcine model. DESIGN: Fourteen animals were randomly assigned to undergo 240 minutes of mild hypothermic MCPB or CCPB. Ileal and colonic biopsies were obtained prior and at the end of CPB. Mucosal damage was determined under light microscopic evaluation. Immunohistochemistry was used to investigate epithelial expression of Ki-67 as a measure of cell proliferation rate and claudin-1, 2, 3, 4, 5, and 7 as elements of tight junctions. RESULTS: In colonic biopsies, independent of the circuit type used, moderate mucosal damage was observed as indicated by focal epithelial damage, increased epithelial cell proliferation and decreased expression of tight junction protein claudin-4. CONCLUSIONS: Colonic mucosal damage was observed similarly in MCPB and CCPB. Based on these results, the effects of MCPB on intestinal mucosal stability are similar to those of CCPB.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Doenças do Colo/etiologia , Doenças do Íleo/etiologia , Mucosa Intestinal/patologia , Animais , Ponte Cardiopulmonar/métodos , Proliferação de Células , Doenças do Colo/metabolismo , Feminino , Doenças do Íleo/metabolismo , Imuno-Histoquímica , Proteínas de Membrana/metabolismo , Procedimentos Cirúrgicos Minimamente Invasivos , Circulação Esplâncnica/fisiologia , Suínos , Junções Íntimas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA