Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Khirurgiia (Mosk) ; (7): 38-43, 2014.
Artigo em Russo | MEDLINE | ID: mdl-25146541

RESUMO

The results of risk factors analysis of aerostasis failure in 141 patients are presented in the article. All patients were operated in the A.V. Vishnevskogo Institute of Surgery at the period from January 2009 to December 2010. During statistical analysis it was considered surgeries volume, presence of emphysema, respiratory function etc. Also it was defined the dependence of venting duration in patients with residual pleural cavity and long aerostasis failure.


Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão , Cavidade Pleural , Pneumonectomia , Enfisema Pulmonar/cirurgia , Insuficiência Respiratória , Deiscência da Ferida Operatória , Feminino , Humanos , Pulmão/fisiopatologia , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Cavidade Pleural/fisiopatologia , Cavidade Pleural/cirurgia , Pneumonectomia/efeitos adversos , Pneumonectomia/métodos , Período Pós-Operatório , Ventilação Pulmonar , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/prevenção & controle , Deiscência da Ferida Operatória/etiologia , Deiscência da Ferida Operatória/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
4.
Khirurgiia (Mosk) ; (8): 15-7, 2013.
Artigo em Russo | MEDLINE | ID: mdl-23996033

RESUMO

The article analyzes the results of the endoscopic tracheal stenting of 33 patients with cicatrical stenosis. The patients aged 19-72 years. All patients had the acquired stenosis after intubation and tracheostomy. In 12 cases the procedure was successful, no complications were observed. In 3 cases the endoscopic stentin was the final stage of the treatment. The temporary stenting was effective in 8 cases. Stent migration was observed in 2 patients. The stent exposition ranged 8-90 days.


Assuntos
Broncoscopia/métodos , Cuidados Pré-Operatórios/métodos , Stents , Traqueia , Estenose Traqueal/cirurgia , Adulto , Idoso , Manuseio das Vias Aéreas/métodos , Cicatriz , Dilatação/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/métodos , Traqueia/patologia , Traqueia/fisiopatologia , Traqueia/cirurgia , Estenose Traqueal/etiologia , Estenose Traqueal/fisiopatologia , Resultado do Tratamento
5.
Khirurgiia (Mosk) ; (4): 30-5, 2012.
Artigo em Russo | MEDLINE | ID: mdl-22810342

RESUMO

The experimental study of the durability of the "collagen" suture of the lung, performed with the use of the Ligasure device, was conducted. 17 patients, whom 21 lung resection was performet took part in the study. In the experimental part of the study the average rupture pressure of the collagen plomb was 413±99.4 mm Hg for the intact lung parenchyma and 212±66.7 mm Hg for the emphisematously changed tissue. The prolonged aerostatic insufficiency was registered only in two cases. The Ligasure suturing device proved to be the highly effective and safe for the use in thoracic surgery.


Assuntos
Pneumopatias/cirurgia , Pulmão/cirurgia , Pneumonectomia/instrumentação , Pneumonectomia/métodos , Técnicas de Sutura/instrumentação , Adulto , Colágeno , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Suturas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA