Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ophthalmic Plast Reconstr Surg ; 40(3): 331-335, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38624153

RESUMO

PURPOSE: Pilot studies suggest that waiting 15 minutes after a subcutaneous tranexamic acid injection is associated with decreased intraoperative bleeding and postoperative ecchymosis in eyelid surgery. The outcomes of commencing eyelid surgery immediately after injection without a waiting period remain unexplored. METHODS: This prospective, randomized, multicenter, double-masked, controlled study examined bilateral symmetric upper and/or lower lid blepharoplasty or ptosis repair. Patients received tranexamic acid in 1 eyelid and control in the contralateral eyelid. The surgeon recorded the side with more intraoperative bleeding. Two masked graders evaluated periocular ecchymosis at postoperative day 0 and postoperative week 1 (POW 1) with a 5-point scale. At POW 1, patients reported subjective grading of bruising as increased on 1 side or similar on both sides. Results were analyzed with Wilcoxon signed-rank and sign tests. RESULTS: Of 130 patients, there was less eyelid ecchymosis on the tranexamic side at postoperative day 0 ( p = 0.001) and POW 1 ( p < 0.001). By surgery type, the 69 levator advancement surgeries had significantly less ecchymosis at postoperative day 0 ( p < 0.001) and POW 1 ( p = 0.001), while upper eyelid blepharoplasty, combined upper and lower lid blepharoplasty, and conjunctivomullerectomy trended toward significance. Of 68 patients reporting a POW 1 grading, 69% reported less bruising on the tranexamic side ( p < 0.001). Intraoperative bleeding was not significantly different between sides ( p = 0.930). CONCLUSIONS: Without a postinjection waiting period, subcutaneous tranexamic acid for eyelid surgery significantly decreased postoperative ecchymosis on postoperative day 0 and POW 1 but did not affect intraoperative bleeding. Subcutaneous tranexamic acid was not associated with any complications.


Assuntos
Antifibrinolíticos , Blefaroplastia , Blefaroptose , Equimose , Pálpebras , Hemorragia Pós-Operatória , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/administração & dosagem , Antifibrinolíticos/administração & dosagem , Estudos Prospectivos , Método Duplo-Cego , Blefaroplastia/métodos , Blefaroplastia/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/prevenção & controle , Hemorragia Pós-Operatória/diagnóstico , Hemorragia Pós-Operatória/etiologia , Idoso , Pálpebras/cirurgia , Equimose/etiologia , Equimose/prevenção & controle , Equimose/diagnóstico , Blefaroptose/cirurgia , Adulto , Perda Sanguínea Cirúrgica/prevenção & controle
2.
J Acad Ophthalmol (2017) ; 15(2): e144-e153, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37564162

RESUMO

Purpose Compare postoperative outcomes in cataract surgery between eyes with standard drop regimen versus dropless protocol by residents. Design Retrospective cohort study between April 1, 2018 and March 31, 2020. Methods The study was performed at Lyndon B. Johnson General Hospital in Houston, Harris County, Texas. A total of 547 eyes (234 dropless vs. 313 standard) with phacoemulsification cataract surgery and minimum of 1-month follow-up with best-corrected visual acuity (BCVA) were included. Dropless received 40 mg sub-Tenon's triamcinolone and intracameral moxifloxacin. Patients were followed at postoperative day 1 (POD1), week 1 (POW1), and month 1 (POM1). Postoperative rate of BCVA better than 20/40 (Good vision) and rate of complications were compared between groups. Results Good vision on POM1 in dropless (77.8%) was noninferior to standard (75.1%, p = 0.80). Complication rate in dropless (28.6%) was noninferior to standard (24.0%, p = 0.13). Intraocular pressure (IOP) elevation on POD1 ( p = 0.041) and anterior chamber (AC) cells on POW1 and POM1 ( p < 0.001) were more frequent in dropless. Mean spherical equivalent at POM1 was better in dropless (-0.37 D [±0.81 D]) compared with standard (-0.61D [±0.77 D], p = 0.001). Early posterior capsular opacification (early PCO) was more frequent in dropless ( p = 0.042). Conclusions Postoperative rate of BCVA better than 20/40 and rate of postoperative complications were noninferior, although dropless had higher rates of AC inflammation, IOP elevation, and early PCO.

3.
Science ; 356(6338): 608-616, 2017 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-28495746

RESUMO

Multiple human diseases ensue from a hereditary or acquired deficiency of iron-transporting protein function that diminishes transmembrane iron flux in distinct sites and directions. Because other iron-transport proteins remain active, labile iron gradients build up across the corresponding protein-deficient membranes. Here we report that a small-molecule natural product, hinokitiol, can harness such gradients to restore iron transport into, within, and/or out of cells. The same compound promotes gut iron absorption in DMT1-deficient rats and ferroportin-deficient mice, as well as hemoglobinization in DMT1- and mitoferrin-deficient zebrafish. These findings illuminate a general mechanistic framework for small molecule-mediated site- and direction-selective restoration of iron transport. They also suggest that small molecules that partially mimic the function of missing protein transporters of iron, and possibly other ions, may have potential in treating human diseases.


Assuntos
Ferro/metabolismo , Animais , Células CACO-2 , Absorção Gastrointestinal , Hemoglobinas/metabolismo , Humanos , Proteínas de Ligação ao Ferro/metabolismo , Monoterpenos/metabolismo , Ratos , Saccharomyces cerevisiae/metabolismo , Tropolona/análogos & derivados , Tropolona/metabolismo
4.
Med Phys ; 43(2): 727-33, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26843236

RESUMO

PURPOSE: The CyberKnife M6 (CK-M6) Series introduced a multileaf collimator (MLC) for extending its capability from stereotactic radiosurgery/stereotactic radiotherapy (SBRT) to conventionally fractionated radiotherapy. This work is to investigate the dosimetric quality of plans that are generated using MLC-shaped beams on the CK-M6, as well as their delivery time, via comparisons with the intensity modulated radiotherapy plans that were clinically used on a Varian Linac for treating hepatic lesions. METHODS: Nine patient cases were selected and divided into three groups with three patients in each group: (1) the group-one patients were treated conventionally (25 fractions); (2) the group-two patients were treated with SBRT-like hypofractionation (5 fractions); and (3) the group-three patients were treated similar to group-one patients, but with two planning target volumes (PTVs) and two different prescription dose levels correspondingly. The clinically used plans were generated on the eclipse treatment planning system (TPS) and delivered on a Varian Linac (E-V plans). The multiplan (MP) TPS was used to replan these clinical cases with the MLC as the beam device for the CK-M6 (C-M plans). After plans were normalized to the same PTV dose coverage, comparisons between the C-M and E-V plans were performed based on D(99%) (percentage of prescription dose received by 99% of the PTV), D(0.1cm(3)) (the percentage of prescription dose to 0.1 cm(3) of the PTV), and doses received by critical structures. Then, the delivery times for the C-M plans will be obtained, which are the MP TPS generated estimations assuming having an imaging interval of 60 s. RESULTS: The difference in D(99%) between C-M and E-V plans is +0.6% on average (+ or - indicating a higher or lower dose from C-M plans than from E-V plans) with a range from -4.1% to +3.8%, and the difference in D(0.1cm(3)) was -1.0% on average with a range from -5.1% to +2.9%. The PTV conformity index (CI) for the C-M plans ranges from 1.07 to 1.29 with a mean of 1.19, slightly inferior to the E-V plans, in which the CI ranges from 1.00 to 1.15 with a mean of 1.07. Accounting for all nine patients in three groups, 45% of the critical structures received a lower mean dose for the C-M plans as compared with the E-V plans, and similarly, 48% received a lower maximum dose. Furthermore, the average difference of the mean critical structure dose between the C-M and E-V plans over all critical structures for all patients showed only +2.10% relative to the prescription dose and the similar comparison finds the average difference of the maximum critical structure dose of only +1.24%. The estimated delivery times for the C-M plans on the CK-M6 range from 18 to 24 minutes while they are from 7 to 13.7 min for the E-V plans on the Varian Linac. CONCLUSIONS: For treating hepatic lesions, for the C-M plans that are comparable to E-V plans in quality, the times needed to deliver these C-M plans on the CK-M6 are longer than the delivery time for the E-V plans on the Varian Linac, but may be clinically acceptable.


Assuntos
Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Radiocirurgia/instrumentação , Robótica , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Aceleradores de Partículas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA