1.
Sci Rep ; 14(1): 1224, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38216583

RESUMO

RadioLab is an Italian project, addressed to school-age people, and designed for the dissemination of scientific culture on the theme of environmental radioactivity, with particular regards to the importance of knowledge of radon gas exposure. The project is a nationwide initiative promoted by the National Institute of Nuclear Physics- INFN. First tool used by the project, and of immediate impact to assess the public awareness on radon, is the administration of the survey "do you know the radon gas?". In the survey, together with the knowledge of radon and of its sources, information on personal, cultural and territorial details regarding the interviewees are also taken. Reasonably, the survey invests not only young people, but also their relatives, school workers and, gradually, the public. The survey is administrated during exhibitions or outreach events devoted to schools, but also open to the public. The survey is in dual form: printed and online. The online mode clearly leads RadioLab project even outside the school environment. Based on the results of the survey, several statistical analyses have been performed and many conclusions are drawn about the knowledge of the population on the radon risk. The RadioLab benefit and the requirement to carry on the project goals, spreading awareness of environmental radioactivity from radon, emerge. The dataset involves all twenty Italian regions and consists of 28,612 entries covering the 5-year period 2018-2022.

2.
Phys Med Biol ; 61(4): 1634-49, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26836274

RESUMO

The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-the-art CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 µm)(3) CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Humanos , Tomografia Computadorizada por Raios X/métodos
3.
Radiat Prot Dosimetry ; 114(1-3): 350-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933135

RESUMO

A simulator for X-ray images is presented based on a virtual X-ray source and a virtual human body obtained from tomographic slices. In the simulator it is possible to modify the tube potential, the anodic current, the exposure time, the filtration and some geometric parameters such as source-skin distance, orientation and field size. The virtual body consists of a three-dimensional voxel matrix in which CT numbers for each point of the body are stored. The interactions of X rays passing through the body are evaluated using the pencil beam technique. The image is obtained by computing the dose absorbed by the detector and converting it into optical density using a proper response function. The image spatial resolution is limited by the voxel size. The influence of each parameter on the image quality can be observed interactively. The dose absorbed in each point of the body is an important parameter obtained as output of the simulator.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Raios X , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Modelos Anatômicos , Modelos Estatísticos , Método de Monte Carlo , Doses de Radiação , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Tomógrafos Computadorizados