Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
CoDAS ; 36(2): e20220261, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534251

RESUMO

ABSTRACT Purpose The inter-aural time difference (ITD) and inter-aural level difference (ILD) are important acoustic cues for horizontal localization and spatial release from masking. These cues are encoded based on inter-aural comparisons of tonotopically matched binaural inputs. Therefore, binaural coherence or the interaural spectro-temporal similarity is a pre-requisite for encoding ITD and ILD. The modulation depth of envelope is an important envelope characteristic that helps in encoding the envelope-ITD. However, inter-aural difference in modulation depth can result in reduced binaural coherence and poor representation of binaural cues as in the case with reverberation, noise and compression in cochlear implants and hearing aids. This study investigated the effect of inter-aural modulation depth difference on the ITD thresholds for an amplitude-modulated noise in normal hearing young adults. Methods An amplitude modulated high pass filtered noise with varying modulation depth differences was presented sequentially through headphones. In one ear, the modulation depth was retained at 90% and in the other ear it varied from 90% to 50%. The ITD thresholds for modulation frequencies of 8 Hz and 16 Hz were estimated as a function of the inter-aural modulation depth difference. Results The Friedman test findings revealed a statistically significant increase in the ITD threshold with an increase in the inter-aural modulation depth difference for 8 Hz and 16 Hz. Conclusion The results indicate that the inter-aural differences in the modulation depth negatively impact ITD perception for an amplitude-modulated high pass filtered noise.

2.
Eur Arch Otorhinolaryngol ; 280(7): 3209-3217, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36695909

RESUMO

PURPOSE: Inter-aural insertion depth difference (IEDD) in bilateral cochlear implant (BiCI) with continuous interleaved sampling (CIS) processing is known to reduce the recognition of speech in noise and spatial release from masking (SRM). However, the independent channel selection in the 'n-of-m' sound coding strategy might have a different effect on speech recognition and SRM when compared to the effects of IEDD in CIS-based findings. This study aimed to investigate the effect of bilateral 'n-of-m' processing strategy and interaural electrode insertion depth difference on speech recognition in noise and SRM under conditions that simulated bilateral cochlear implant listening. METHODS: Five young adults with normal hearing sensitivity participated in the study. The target sentences were spatially filtered to originate from 0° and the masker was spatially filtered at 0°, 15°, 37.5°, and 90° using the Oldenburg head-related transfer function database for behind the ear microphone. A 22-channel sine wave vocoder processing based on 'n-of-m' processing was applied to the spatialized target-masker mixture, in each ear. The perceptual experiment involved a test of speech recognition in noise under one co-located condition (target and masker at 0°) and three spatially separated conditions (target at 0°, masker at 15°, 37.5°, or 90° to the right ear). RESULTS: The results were analyzed using a three-way repeated measure analysis of variance (ANOVA). The effect of interaural insertion depth difference (F (2,8) = 3.145, p = 0.098, ɳ2 = 0.007) and spatial separation between target and masker (F (3,12) = 1.239, p = 0.339, ɳ2 = 0.004) on speech recognition in noise was not significant. CONCLUSIONS: Speech recognition in noise and SRM were not affected by IEDD ≤ 3 mm. Bilateral 'n-of-m' processing resulted in reduced speech recognition in noise and SRM.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto Jovem , Humanos , Implante Coclear/métodos , Percepção Auditiva , Ruído , Mascaramento Perceptivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA