Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Radiat Prot Dosimetry ; 194(1): 42-56, 2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-33989429

RESUMO

Since 2012, the European Radiation Dosimetry Group (EURADOS) has developed its Strategic Research Agenda (SRA), which contributes to the identification of future research needs in radiation dosimetry in Europe. Continued scientific developments in this field necessitate regular updates and, consequently, this paper summarises the latest revision of the SRA, with input regarding the state of the art and vision for the future contributed by EURADOS Working Groups and through a stakeholder workshop. Five visions define key issues in dosimetry research that are considered important over at least the next decade. They include scientific objectives and developments in (i) updated fundamental dose concepts and quantities, (ii) improved radiation risk estimates deduced from epidemiological cohorts, (iii) efficient dose assessment for radiological emergencies, (iv) integrated personalised dosimetry in medical applications and (v) improved radiation protection of workers and the public. This SRA will be used as a guideline for future activities of EURADOS Working Groups but can also be used as guidance for research in radiation dosimetry by the wider community. It will also be used as input for a general European research roadmap for radiation protection, following similar previous contributions to the European Joint Programme for the Integration of Radiation Protection Research, under the Horizon 2020 programme (CONCERT). The full version of the SRA is available as a EURADOS report (www.eurados.org).


Assuntos
Monitoramento de Radiação , Proteção Radiológica , Europa (Continente) , Humanos , Doses de Radiação , Radiação Ionizante , Radiometria
2.
Radiat Environ Biophys ; 59(3): 357-387, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32372284

RESUMO

This work presents an overview of the applications of retrospective dosimetry techniques in case of incorporation of radionuclides. The fact that internal exposures are characterized by a spatially inhomogeneous irradiation of the body, which is potentially prolonged over large periods and variable over time, is particularly problematic for biological and electron paramagnetic resonance (EPR) dosimetry methods when compared with external exposures. The paper gives initially specific information about internal dosimetry methods, the most common cytogenetic techniques used in biological dosimetry and EPR dosimetry applied to tooth enamel. Based on real-case scenarios, dose estimates obtained from bioassay data as well as with biological and/or EPR dosimetry are compared and critically discussed. In most of the scenarios presented, concomitant external exposures were responsible for the greater portion of the received dose. As no assay is available which can discriminate between radiation of different types and different LETs on the basis of the type of damage induced, it is not possible to infer from these studies specific conclusions valid for incorporated radionuclides alone. The biological dosimetry assays and EPR techniques proved to be most applicable in cases when the radionuclides are almost homogeneously distributed in the body. No compelling evidence was obtained in other cases of extremely inhomogeneous distribution. Retrospective dosimetry needs to be optimized and further developed in order to be able to deal with real exposure cases, where a mixture of both external and internal exposures will be encountered most of the times.


Assuntos
Radiação Ionizante , Radiometria/métodos , Animais , Espectroscopia de Ressonância de Spin Eletrônica , Humanos , Radioisótopos/farmacocinética
3.
Radiat Prot Dosimetry ; 186(1): 78-82, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30806468

RESUMO

The treatment with high doses of ionizing radiation is prescribed for the terminal sterilization of many healthcare products. In order to check the product irradiation, it may be useful to develop suitable detection methods. The aim of this work was to verify the suitability of the thermoluminescence (TL) and electron paramagnetic resonance (EPR) techniques to reveal illegal omission of radiation sterilization in glass used for blood test tubes. In particular, this work reports the results of the analysis performed on two batches of glass tubes provided by the same manufacturer. The results indicated that both TL and EPR techniques could reveal the damage induced by high doses of ionizing radiation in the glass allowing the identification of the tubes which were irradiated at the manufacture stage. The study provided also some information about the chemical composition of the two-batch glass.


Assuntos
Produtos Biológicos/análise , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Vidro/química , Vidro/efeitos da radiação , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Relação Dose-Resposta à Radiação , Humanos , Medições Luminescentes , Radiação Ionizante
4.
Radiat Prot Dosimetry ; 168(2): 223-34, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25752758

RESUMO

Since autumn 2012, the European Radiation Dosimetry Group (EURADOS) has been developing its Strategic Research Agenda (SRA), which is intended to contribute to the identification of future research needs in radiation dosimetry in Europe. The present article summarises-based on input from EURADOS Working Groups (WGs) and Voting Members-five visions in dosimetry and defines key issues in dosimetry research that are considered important for the next decades. The five visions include scientific developments required towards (a) updated fundamental dose concepts and quantities, (b) improved radiation risk estimates deduced from epidemiological cohorts, (c) efficient dose assessment for radiological emergencies, (d) integrated personalised dosimetry in medical applications and (e) improved radiation protection of workers and the public. The SRA of EURADOS will be used as a guideline for future activities of the EURADOS WGs. A detailed version of the SRA can be downloaded as a EURADOS report from the EURADOS website (www.eurados.org).


Assuntos
Pesquisa Biomédica , Monitoramento de Radiação/normas , Proteção Radiológica , Radiação Ionizante , Radiometria/normas , Europa (Continente) , Guias como Assunto , Humanos , Doses de Radiação
5.
Radiat Environ Biophys ; 54(4): 433-44, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26205380

RESUMO

Waterborne radioactive releases into the Techa River from the Mayak Production Association in Russia during 1949-1956 resulted in significant doses to about 30,000 persons who lived in downstream settlements. The residents were exposed to internal and external radiation. Two methods for reconstruction of the external dose are considered in this paper, electron paramagnetic resonance (EPR) measurements of teeth, and fluorescence in situ hybridization (FISH) measurements of chromosome translocations in circulating lymphocytes. The main issue in the application of the EPR and FISH methods for reconstruction of the external dose for the Techa Riverside residents was strontium radioisotopes incorporated in teeth and bones that act as a source of confounding local exposures. In order to estimate and subtract doses from incorporated (89,90)Sr, the EPR and FISH assays were supported by measurements of (90)Sr-body burdens and estimates of (90)Sr concentrations in dental tissues by the luminescence method. The resulting dose estimates derived from EPR to FISH measurements for residents of the upper Techa River were found to be consistent: The mean values vary from 510 to 550 mGy for the villages located close to the site of radioactive release to 130-160 mGy for the more distant villages. The upper bound of individual estimates for both methods is equal to 2.2-2.3 Gy. The EPR- and FISH-based dose estimates were compared with the doses calculated for the donors using the most recent Techa River Dosimetry System (TRDS). The TRDS external dose assessments are based on the data on contamination of the Techa River floodplain, simulation of air kerma above the contaminated soil, age-dependent lifestyles and individual residence histories. For correct comparison, TRDS-based doses were calculated from two sources: external exposure from the contaminated environment and internal exposure from (137)Cs incorporated in donors' soft tissues. It is shown here that the TRDS-based absorbed doses in tooth enamel and muscle are in agreement with EPR- and FISH-based estimates within uncertainty bounds. Basically, this agreement between the estimates has confirmed the validity of external doses calculated with the TRDS.


Assuntos
Esmalte Dentário/química , Espectroscopia de Ressonância de Spin Eletrônica , Hibridização in Situ Fluorescente , Músculo Esquelético/química , Exposição à Radiação/análise , Monitoramento de Radiação , Radioisótopos de Estrôncio/análise , Absorção de Radiação , Idoso , Idoso de 80 Anos ou mais , Bioensaio , Feminino , Humanos , Masculino , Liberação Nociva de Radioativos , Resíduos Radioativos/análise , Reprodutibilidade dos Testes , Federação Russa , Sensibilidade e Especificidade , Poluentes Radioativos da Água/análise , Contagem Corporal Total
6.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25205835

RESUMO

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Emergências , Europa (Continente) , Humanos , Exposição à Radiação/prevenção & controle , Gestão da Segurança/organização & administração
7.
Radiat Prot Dosimetry ; 151(4): 621-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22923244

RESUMO

In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.


Assuntos
Proteção Radiológica , Liberação Nociva de Radioativos , Defesa Civil , Emergências , Europa (Continente) , Humanos , Liberação Nociva de Radioativos/prevenção & controle
8.
Eur Biophys J ; 40(10): 1115-20, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21866359

RESUMO

Structural and functional effects of exposing murine fibroblasts (NIH 3T3) to therapeutic ultrasound at 1 MHz frequency are described. These bioeffects can be attributed to the formation of free radical species by sonolysis of water. When cavitation occurs, dissociation of water vapor into H atoms and OH radicals is observed; these H atoms and OH radicals combine to form H(2), H(2)O(2), and HO(2). The radicals can chemically modify biomolecules, for example enzymes, DNA, and lipids. Generation of free radicals during exposure to ultrasound with or without encapsulated microbubbles (contrast agents) was studied by use of electron paramagnetic resonance with DMPO spin trapping. Recently the potential for possible use of these microbubbles in gene therapy has been investigated, because of the ability of the stabilized microbubbles to release their content when exposed to ultrasound. Structural changes were studied by Fourier-transform infrared spectroscopy, and induction of possible genotoxic damage by exposure of the cells to therapeutic ultrasound at 1 MHz frequency with our experimental device was verified by use of the cytokinesis-block micronucleus assay.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Fibroblastos/efeitos dos fármacos , Fibroblastos/efeitos da radiação , Microbolhas , Som , Espectroscopia de Infravermelho com Transformada de Fourier , Terapia por Ultrassom , Animais , Soluções Tampão , Linhagem Celular , Óxidos N-Cíclicos/química , Citocinese/genética , Fibroblastos/citologia , Terapia Genética/métodos , Radical Hidroxila/química , Radical Hidroxila/metabolismo , Camundongos , Microbolhas/efeitos adversos , Testes para Micronúcleos , Células NIH 3T3 , Fosfatos/química , Som/efeitos adversos , Detecção de Spin , Terapia por Ultrassom/efeitos adversos
9.
Radiat Prot Dosimetry ; 147(4): 573-92, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21183550

RESUMO

The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements.


Assuntos
Monitoramento de Radiação , Radiação Ionizante , Radiometria/métodos , Carga Corporal (Radioterapia) , Humanos , Doses de Radiação , Estudos Retrospectivos , Medição de Risco
10.
Appl Radiat Isot ; 62(2): 261-5, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15607459

RESUMO

A pilot program of postal dosimetry intercomparison among 16 Italian Radiotherapy Centers was performed using the ISS Alanine/EPR dosimetry as a transfer system. Dosimeters were irradiated at 10 Gy with high-energy photon beams, both in reference condition in a water phantom and in an anthropomorphic phantom during the simulated treatment of rectum cancer. Intercomparison design along with alanine performances analyzing the different contributions to the combined uncertainty in dose assessment are reported. Main results of the pilot intercomparison, terminated in 2002, are also presented.


Assuntos
Alanina/química , Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Radiometria/normas , Radioterapia/normas , Carga Corporal (Radioterapia) , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Espectroscopia de Ressonância de Spin Eletrônica/normas , Itália , Medicina Nuclear/normas , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde/normas , Doses de Radiação , Monitoramento de Radiação , Radiometria/instrumentação , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Radiat Prot Dosimetry ; 110(1-4): 437-42, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353687

RESUMO

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident absorbed dose, analyzed results show the EPR potentiality and complementarity with regular criticality techniques.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Raios gama , Nêutrons , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Radiometria/métodos , Medição de Risco/métodos , Carga Corporal (Radioterapia) , Espectroscopia de Ressonância de Spin Eletrônica/normas , França , Humanos , Reatores Nucleares , Variações Dependentes do Observador , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Proteção Radiológica/normas , Radiometria/normas , Padrões de Referência , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Medição de Risco/normas , Fatores de Risco , Gestão da Segurança/métodos , Sensibilidade e Especificidade
12.
Acta Paediatr ; 88(7): 693-702, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10447122

RESUMO

Knowledge and awareness of physicians and the general public concerning the risks of prenatal exposure to ionizing radiation are important when developing a correct attitude to ionizing radiation. This is particularly important in the justification of medical diagnostic exposure of pregnant women and in case of possible accidents. The present paper reviews the most recent data on the effects of prenatal exposure to ionizing radiation reported in the scientific literature and in documents of international organizations dealing with this subject. Potentially significant exposure for women of childbearing age in medical diagnostics, working conditions and environmental contamination following the Chernobyl accident are reported. Some examples of doses associated with medical exposure in the course of diagnostic examinations with X-rays and radiopharmaceuticals, and occupational exposure in workplaces are given. Lastly, the regulatory aspects of the European Union directives and the Italian legislation on medical and occupational exposure of women during pregnancy or in reproductive age are reviewed.


Assuntos
Feto/efeitos da radiação , Efeitos Tardios da Exposição Pré-Natal , Proteção Radiológica , Relação Dose-Resposta à Radiação , Feminino , Doenças Fetais/etiologia , Humanos , Itália , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/legislação & jurisprudência , Gravidez , Proteção Radiológica/legislação & jurisprudência , Liberação Nociva de Radioativos , Fatores de Risco , Trabalho
13.
Med Phys ; 24(3): 447-53, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9089596

RESUMO

An analysis of some of the properties of the ESR-alanine dosimetry in therapeutic proton beams is reported. Thin alanine-based detectors (1 and 2 mm thick pellets and 0.25 mm thick films) were tested in a clinical 62 MeV proton beam. The response of the alanine detectors in unmodulated and modulated proton beams was studied in tissue equivalent phantoms. The dose assessed by alanine was compared to the dose provided by a Markus parallel plate ionization chamber, used for reference dosimetry. Experiments in the 5-250 Gy dose range showed linearity of alanine dose response and no significant differences in the alanine response per unit dose to gammas and protons. Agreement within the experimental uncertainties was found between the alanine and the Markus chamber depth dose curves, including the Bragg peak region.


Assuntos
Alanina/efeitos da radiação , Terapia com Prótons , Radiometria/métodos , Fenômenos Biofísicos , Biofísica , Relação Dose-Resposta à Radiação , Espectroscopia de Ressonância de Spin Eletrônica , Estudos de Avaliação como Assunto , Humanos , Imagens de Fantasmas , Radioterapia de Alta Energia , Tecnologia Radiológica , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA