1.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635286

RESUMO

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Estudos de Viabilidade , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Meios de Contraste , Aortografia
2.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635287

RESUMO

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Sistema de Registros , Humanos , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Endoleak/etiologia , Fatores de Tempo , Resultado do Tratamento , Idoso de 80 Anos ou mais , Stents , Estudos Retrospectivos , Fatores de Risco , Rotulagem de Produtos , Correção Endovascular de Aneurisma
3.
J Vasc Surg Cases Innov Tech ; 8(4): 638-645, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35873717

RESUMO

Objective: To report methodology and first-year results of a new educational project called Televascular Games," which took place during coronavirus disease 2019 pandemic. Methods: Complex aneurysmal aortic disease was discussed during a 2-hour competition webinar, according to three modalities. (1) Planning case competition (PCC): Two to four preoperative computed tomography angiography (CTA) scans of an already performed selected case were submitted for the competition. CTA scans were uploaded anonymously, without any reference to the center or the surgeon who performed the case. The competitor had to prepare a presentation of how he or she would have diagnosed, sized, planned, treated, and followed up the case, of the medical therapy and of the bail-out maneuvers. (2) Challenging case competition (CCC): The competitor elaborates a presentation of an already treated case concerning an aortic topic and discusses sizing, planning, treatment, possible bail-out maneuvers and obtained results. For the CCC and PCC, the competitors with the best score were preselected to present and discuss their plan during the webinars. (3) Quiz competition: Two to six CTA scans of already performed selected aortic cases were submitted for the competition. A quiz with multiple choice questions was answered by the competitors. The top four competitors were selected for the webinars and then they discussed the cases during the webinar. Finally, at the end of the case discussion, the effective case resolution and follow-up were shown. A final winner was voted via televoting, based on six preestablished criteria. The project was endorsed by different national and international societies. Results: Between October 2020 and December 2021, there were 12 Italian and 1 international webinars with 1695 participants overall (mean, 130; range, 86-177). Competitors were 54 years of age (mean, 27 years; range, 22-38 years). Two editions were CCCs, two quiz competitions, and nine PCCs. The reliability of the interobserver sizing of competitors was κ = 0.43 and κ = 0.62 for the proximal and distal sealing measurements respectively and very good (κ = 0.88-0.95) in the evaluation of orientation of the vessels, presence of angulations, calcifications, and thrombus. The sizing discrepancy resulted in a significant variability of the planning (κ = 0.45). The project ranked 9.6 on a 10-point rating scale by all the participants and competitors. Conclusions: The formula of gaming and collegial discussion of aortic cases herein reported has proved valid and attractive during coronavirus disease 2019 pandemic period. The variability of the results on sizing and planning suggested to confer with a second opinion, especially for less experienced surgeons.

4.
Vascular ; 30(6): 1058-1068, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35199611

RESUMO

OBJECTIVE: Recent guidelines recognize the role of chimney endovascular aneurysm repair (ChEVAR) in the treatment of complex aortic disorders. The optimal configuration and number of visceral vessels that can be incorporated is still controversial. We aim to review outcomes from a multi-institutional decade-long experience with ChEVAR. METHODS: Patients undergoing ChEVAR with multiple (≥2) chimney branches were selected from a prospectively maintained database at the two academic university hospitals. All patients were poorly suited for fenestrated or branched endograft repair (F/BEVAR) and deemed poor-risk for open surgery. RESULTS: Forty-nine multiple ChEVAR were performed in 44 men and 5 women, with complete outcome data at a mean follow-up of 18 months. Overall, 2 patients died during follow-up (4%) with no aneurysm-related mortality and two ruptures after ChEVAR (4.1%) due to a type Ib endoleak from iliac limb pullout and persistent gutter-flow, both repaired with endovascular means. No stroke or spinal cord ischemia was noted during the follow-up period. Reintervention was undertaken in eight patients (16.3%) with five reinterventions for persistent gutter-flow and four chimney graft-associated. Three-vessel ChEVAR was performed in 16 patients, with two-vessel ChEVAR in 33 patients for a total of 114 chimney branches (mean 2.3 chimneys per patient). There were 21 superior mesenteric artery (SMA), 45 right renal, 46 left renal artery (LRA), and two accessory LRA chimneys placed. Antegrade configuration of chimney branches was chosen in 43 patients (88%). There were no significant differences between three-vessel and two-vessel ChEVAR upon univariate analysis in aneurysm size (65.6 vs 60.5 mm; p = 0.059), iliac diameter (7.3 vs 7.1 mm; p = 0.85), or endograft oversizing (30 vs 32.5%; p = 0.43). Three-vessel ChEVAR was associated with a larger aneurysm neck diameter (28.4 vs 25.0 mm; p = 0.021), shorter native infrarenal neck (0.5 vs 3.37 mm; p = 0.002) as well as longer seal zone (36.33 vs 22.67 mm; p = 0.005) compared with two-vessel ChEVAR. At follow-up, there were no significant differences in gutter area between three-vessel and two-vessel ChEVAR (18.9 vs 15.7 mm3; p = 0.73) nor the rate of persistent gutter-flow (12.5 vs 9.1%; p = 0.71). CONCLUSION: Reintervention to multiple chimney grafts and for persistent gutter-flow is higher compared to single chimneys and demands close surveillance. However, based upon this combined transantlantic experience, we believe multiple ChEVAR provides a reasonable and safe option for complex aortic aneurysm repair when open or custom endografts are not available or indicated based on their Instructions For use, even when triple chimney grafts are required. The optimal configuration for multiple ChEVAR still warrants further study, although theoretical preliminary advantages may exist for a combination of antegrade and retrograde chimneys.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos
5.
Rev Cardiovasc Med ; 22(4): 1641-1647, 2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957806

RESUMO

Late open conversion in our center has been reviewed in the past 8 years, comparing 1997-2011 (first period group A) with 2012-2020 (second period group B). A retrospective analysis of patients treated at our centre by standard EVAR for infrarenal aortic aneurysm requiring late open conversion between January 1997 and February 2020 was performed. All stent grafts were implanted according to their current IFU all patients. The data concerning intra and postoperative complications were collected. Post-operative evaluated data include: ICU (Intensive Care Unit) stay, major peri-operative (<30 days) complications, in hospital mortality, length of hospital stay, 30-days mortality, and mid-term outcomes. Between January 2012 and February 2020 (group B), in our institution 8 patients previously treated by stent graft with endoleak underwent open surgery. The incidence of conversions and the 30-day mortality rate were compared with that of previous years, from January 1997 to December 2011 (group A). 481 patients submitted to EVAR in a second part of the analysis have been considered, 8 patients underwent late open conversion (1.7%) (Group B) due to endoleak. Among January 1997 and December 2011 overall 268 EVAR were performed; during this first study period, surgical conversion had been performed in 14 patients (5.2%) (Group A). The average time from EVAR to open conversion was four years (range 12-88 months) in Group B, and it was 30 months (range 1-82 months) in Group A. In most cases, in both group A and group B the proximal aortic cross-clamping were infrarenal. After the emergent procedure in Group B (12.5%), we have observed a death, whereas three patients died in Group A in urgent situations (21.4%). The more frequent indication for open surgery is the Endoleak type 1 and migration in the two considered periods. Adherence with current IFU and the technical progress in endoprosthesis design maintain lower rate incidence. In most cases, open surgery for prostheses that require explantation can be performed with infrarenal clamping. Partial removal of the endoprosthesis in selected cases makes open conversion easier and appears durable. The results are unfair by numerous comorbidities; in both periods, urgent graft removal seems to elevate both mortality and morbidity, compared to elective surgery.


Assuntos
Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
6.
Ann Vasc Surg ; 75: 455-460, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33826956

RESUMO

BACKGROUND: The post-implantation syndrome may occur shortly after endovascular aneurysm repair in patients treated for abdominal aortic aneurysm. Different types of biomaterials may provoke varying inflammatory responses in patients receiving different endografts. The purpose of this article is to evaluate the PIS after EVAR and the influence of different types of device fabric. METHODS: All patients submitted to elective AAA endovascular repair at our institution from January 2014 to December 2019 were enrolled. The PIS was defined by a body temperature of >38°C and WBC >12'000/µl without any evidence of an infection during (48h) the observation period. RESULTS: Three hundred and sixty-seven patients (89% males) were enrolled in this study and post-implantation syndrome occurred in 41 cases (11.2%). The incidence of PIS was significantly higher (P< 0.001) in patients treated with polyester stent grafts (39/201, 19,4%) compared to patients with PTFE stent grafts (2/166, 1,2%). CRP was related to the presence of PIS with a cut-off values of 109.31 mg/dL (P = 0.0052). The median in-hospital stay considering the polyester group was 6,2 days, while in the PTFE group it was 5,6 days (P = 0.04). CONCLUSIONS: The postoperative inflammatory response after EVAR seems significantly higher by using polyester stent graft compared to PTFE devices. CRP could be a useful biomarker in defining PIS. Multi-center studies are necessary to confirm these data.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Poliésteres , Stents , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Fatores de Tempo , Resultado do Tratamento
7.
Ann Vasc Surg ; 75: 397-405, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33556526

RESUMO

BACKGROUND: Durability of low-profile branched aortic stent-grafts (LPSG) in the treatment of patients with thoracoabdominal aortic aneurysms (TAAA) remains unclear. Objective of this study is to compare the outcomes of LPSG with standard profile branched aortic stent-grafts (SPSG). METHODS: Between January 2016 and January 2020, 225 consecutive patients with TAAA were treated by branched endovascular aortic repair (BEVAR). Twenty-four patients who were treated with a LPSG were compared to 24 patients who received SPSG as a control group. Control patients were selected according to aneurysm size (maximum aneurysm diameter) and extension (Crawford classification) as well as availability of adequate preoperative and postoperative CT-angiograms at 24 months. The primary endpoint was ongoing clinical success defined as successful implantation and freedom from aneurysm- or procedure-related death, secondary intervention, type I or III endoleak, infection, thrombosis, aneurysm expansion or rupture and conversion. Secondary endpoints were radiological changes of the branched endograft (migration, shortening, scoliosis, lordosis, and fracture). RESULTS: After a median follow-up of 22.6 (LPSG) and 26.2 months (SPSG), no significant difference was found in terms of technical success (100% in both groups), late mortality (4.2% vs 0%), aneurysm diameter increase (4.2% in both groups) and reinterventions (25% vs 37.5%). Infection, thrombosis, aneurysm expansion or rupture and conversion were not observed. Radiological analysis of aortic graft remodeling showed no fracture and no significant migration, shortening, scoliosis and lordosis of the LPSG (6.1 mm, 7.5 mm, 12.8° and 6.1°) compared to SPSG (3.9 mm, 5.1 mm, 7.9° and 5.6°) after 2 years. CONCLUSION: The clinical and radiological findings of the present study showed no increased mortality and complications for the matched patients who underwent treatment with low-profile vs standard-profile BEVAR. This study provides preliminary evidence of safety and efficacy of low-profile branched endografts in patients with demanding iliac access vessels.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aortografia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Eur J Vasc Endovasc Surg ; 61(4): 591-602, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33573913

RESUMO

OBJECTIVE: The aim was to identify predictors of adequate pre-operative sizing and planning for chimney endovascular aortic repair (ChEVAR) in order to reduce the incidence of persistent type Ia endoleaks (IaELs) without influencing chimney graft (CG) patency. METHODS: Consecutive patients who underwent ChEVAR between January 2009 and December 2017 at a single centre were evaluated retrospectively. Included were patients treated with one device combination (Medtronic Endurant mated with Getinge Advanta V12/iCast) and placement of single or double CG. The freedom from IaEL related re-interventions and primary CG patency was estimated by measuring aortic stent graft oversizing (OS), total neck length (TNL), and a composite parameter (L-OS: TNL [mm] + OS [%]). RESULTS: Seventy-three patients who underwent placement of 101 CGs (45 single, 28 double) met the inclusion criteria. The median radiological follow up was 25.5 (interquartile range [IQR] 12-48) months. Freedom from IaEL related re-intervention was achieved in 94.6% with a median OS of 38.5% (IQR 30%-44%, p = .004), TNL 19 mm (16-25 mm, p = .62), and L-OS 59 (51-65, p = .018). Primary CG patency was achieved in 95% of the cases with a median OS of 36% (29%-42%, p = .008), TNL 19 mm (15.5-26 mm, p = .91), and L-OS 57 (50-64, p = .005). By using the receiver operating characteristic curve, an optimal cut off to prevent IaEL related re-interventions was identified by an OS of 30% (p < .001; L-OS 55, p = .006) and to avoid CG stenosis/occlusions by OS 42% (p < .001; L-OS 65, p < .001). In multivariable analysis, aortic endograft OS was the only independent parameter preventive for IaEL related re-intervention (odds ratio, 0.78; 95% confidence interval, 0.61-0.99). CONCLUSION: With the Endurant-Advanta V12/iCast combination, an aortic stent graft OS of at least 30% (range 30%-42%) should be used to avoid type Ia endoleaks and likewise to ensure CG patency.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
J Vasc Surg ; 73(2): 433-442, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32473338

RESUMO

OBJECTIVE: In the treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes, chimney endovascular aneurysm repair (CHEVAR) represents an alternative technique for urgent cases. The aim of the study was to evaluate the outcomes of CHEVAR in the elective setting. METHODS: We performed a retrospective analysis of prospectively collected records of 165 consecutive asymptomatic CHEVAR patients who were treated between March 2009 and January 2018 with the Endurant stent graft (Medtronic, Santa Rosa, Calif). A total of 244 chimney grafts (CGs) were implanted. The primary end point was clinical success, defined as freedom from procedure-related mortality, persistent type IA endoleak, occlusion or high-grade stenosis (>70%) of CGs, and any chimney technique-related secondary procedure for the entire follow-up period. Secondary clinical success included patients with successful treatment of a primary end point with a secondary endovascular procedure. RESULTS: All 244 targeted chimney vessels were successfully cannulated. Total perioperative morbidity was 7.8% (n = 13), including 3 (1.8%) cases of bowel ischemia, 1 (0.6%) patient with renal ischemia, and 1 patient (0.6%) with stroke. Median follow-up was 25.5 ± 2.2 months. Both 30-day and follow-up procedure-related mortality rates were 1.8% (n = 3). Primary and secondary freedom from persistent type IA endoleak rates were 96.4% (n = 159) and 99.4% (n = 164), respectively. Primary and secondary CG patency rates were 92.2% (n = 225) and 95.9% (n = 234), respectively. The rate of reinterventions related to the chimney technique was 10.9% (n = 18), and 83.3% of them were performed by endovascular means. The estimated cumulative primary patency and freedom from persistent type IA endoleak were 87.5% and 95.3%, respectively, and the primary and secondary clinical successes rates at midterm were 80.3% and 87.5%, respectively. CONCLUSIONS: The elective use of CHEVAR with the Endurant stent graft in our series showed favorable midterm clinical results, which are similar to the published results of other total endovascular modalities. A prospective randomized trial of elective treatment of pararenal abdominal aortic aneurysms and aortic pathologic processes with current endovascular options is needed to assess the value of CHEVAR in the elective setting.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Comorbidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
J Vasc Surg ; 73(6): 1942-1949, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33259893

RESUMO

OBJECTIVE: The early and short-term efficacy of the snorkel/chimney technique for endovascular aortic aneurysm repair (ch-EVAR) have been previously reported. However, long-term ch-EVAR performance, vessel patency, and patient survival remain unknown. Our study evaluated the late outcomes to identify possible predictors of failure within the PERICLES (performance of the chimney technique for the treatment of complex aortic pathologies) registry. METHODS: Clinical and radiographic data from patients who had undergone ch-EVAR from 2008 to 2014 in the PERICLES registry were updated with an extension of the follow-up. Regression models were used to evaluate the relevant anatomic and operative characteristics as factors influencing the late results. We focused on patients with ≥30 months of follow-up (mean, 46.6 months; range, 30-120 months). RESULTS: A total of 517 patients from the initial PERICLES registry were included in the present analysis, from which the mean follow-up was updated from 17.1 months to 28.2 months (range, 1-120 months). All-cause mortality at the latest follow-up was 25.5% (n = 132), with an estimated patient survival of 87.6%, 74.4%, and 66.1% at 1, 3, and 5 years, respectively. A subgroup of 244 patients with 387 chimney grafts placed (335 renal arteries, 42 superior mesenteric arteries, 10 celiac arteries) and follow-up for ≥30 months was used to analyze specific anatomic and device predictors of adverse events. In the subgroup, the technical success was 88.9%, and the primary patency was 94%, 92.8%, 92%, and 90.5% at 2.5, 3, 4, and 5 years, respectively. The mean aneurysm sac regression was 7.8 ± 11.4 mm (P < .0001). Chimney graft occlusion had occurred in 24 target vessels (6.2%). Late open conversion was required in 5 patients for endograft infection in 2, persistent type Ia endoleak in 2, and endotension in 1 patient. The absence of an infrarenal neck (odds ratio, 2.86; 95% confidence interval, 1.32-6.19; P = .007) was significantly associated with long-term device-related complications. A sealing zone diameter >30 mm was significantly associated with persistent or late type Ia endoleak (odds ratio, 4.86; 95% confidence interval, 1.42-16.59; P = .012). CONCLUSIONS: The present analysis of the PERICLES registry has provided the missing long-term experience for the ch-EVAR technique, showing favorable results with more than one half of the patients surviving for >5 years and a chimney graft branch vessel patency of 92%. The absence of an infrarenal neck and treatment with a sealing zone diameter >30 mm were the main anatomic long-term limits of the technique, requiring adequate preoperative planning and determination of the appropriate indication.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
11.
J Endovasc Ther ; 27(6): 902-909, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32813593

RESUMO

PURPOSE: To analyze the overall performance of flexible nitinol stents used to line chimney grafts (CGs) during chimney endovascular aneurysm repair (chEVAR) of pararenal pathologies. MATERIALS AND METHODS: A retrospective review was conducted of all 116 elective patients (mean age 74.3±7.2 years; 103 men) who underwent chEVAR with balloon-expandable Advanta V12/iCAST CGs in combination with the Endurant stent-graft between January 2009 and December 2017 at a single center. CG lining with a nitinol stent was electively performed in 43 target vessels of 32 patients. The Kaplan-Meier method was used to estimate the primary outcomes of CG patency and freedom from reintervention (FFR) at the patient level and according to the use of a stent to line the CG. Estimates are reported with the 95% confidence interval (CI). Adjusted odds ratios (ORs) were calculated to identify any confounding effect between the presence/absence of a stent lining or according to the number of CGs. RESULTS: The mean radiological follow-up was 27.3 months (range 22.1-32.6). During this time, 8 CGs (4.7%) became occluded, 6 of them were lined with stents. Restoration of patency was possible in 3 of the 4 occluded stents that were associated with symptoms. First-year primary patency estimates were 96.9% (95% CI 92.5% to 100%) for the unlined group vs 77.1% (95% CI 58% to 95.3%; p=0.001) for the lined group, while FFR was 87.6% (95% CI 79.9% to 95.2%) vs 83.4% (95% CI 68.1% to 98.6%; p=0.82), respectively. Lining represented an independent risk factor for CG occlusion (OR 9.9, p=0.006). CONCLUSION: CG lining performed mainly in angulated renal arteries during chEVAR was significantly associated with CG occlusion. These findings highlight the importance of not having the distal part of the CG impinge on the angulated segment of the target vessel.


Assuntos
Aneurisma , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Renal , Stents , Idoso , Idoso de 80 Anos ou mais , Ligas , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Estudos Retrospectivos , Fatores de Risco , Aço Inoxidável , Resultado do Tratamento
12.
Ann Vasc Surg ; 62: 365-374, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31560939

RESUMO

BACKGROUND: The aim of this study is to assess our experience and mid-term outcomes using Jetstream atherectomy system for treatment of femoropopliteal artery disease (FPAD). METHODS: Data of 30 patients with FPAD treated at our center between 2013 and 2016 were analyzed. Two subgroups of patients were identified: Group A included patients (n = 18) with de novo lesions; Group B (n = 12) included those with in-stent restenosis. The primary study end points assessed were technical success, perioperative mortality, and major adverse event (MAE) rate at 30 days (distal embolization, major amputation, and target lesion revascularization). Other outcomes measured were survival, primary, and secondary patency, and freedom from amputation at 1 and 3 years of follow-up, respectively. RESULTS: Technical success was 100% for both groups. The MAE rate was 8.7%. No distal filter was adopted during intervention. Angioplasty was associated with 93.3% of cases (93.3% vs. 100%; P = 0.15), drug-eluting balloon (DEB) in 12 cases (22.2% vs. 66.6%; P = 0.008), drug-eluting stent and bare metal implantation in 1 (5.6% vs. 0%; P = 1) and 4 cases (11.1% vs. 16.7%; P = 1), respectively. The cumulative primary and secondary patency rates were 75.1% and 95.5% at 1 year, and 70.4% and 84.8% at 3 years of follow-up, respectively. The survival and freedom from amputation were 96.4% and 85.8% at 1 and 3 years of follow-up, respectively. The freedom from target lesion revascularization was 91.7% and 83.4% at 1 and 3 years from intervention. CONCLUSIONS: The use of the Jetstream appears to be safe and feasible with no distal embolization and low rate perioperative complications. Moreover, encouraging outcomes were observed when atherectomy was associated to DEB angioplasty.


Assuntos
Angioplastia com Balão , Aterectomia/instrumentação , Artéria Femoral , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Aterectomia/efeitos adversos , Aterectomia/mortalidade , Materiais Revestidos Biocompatíveis , Bases de Dados Factuais , Stents Farmacológicos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Itália , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Intervalo Livre de Progressão , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular
14.
J Endovasc Ther ; 25(4): 492-498, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29911481

RESUMO

PURPOSE: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). METHODS: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). Overall, 70 visceral vessels were targeted for revascularization. RESULTS: Technical success was achieved in 35 (89.7%) cases; 3 persistent type Ia endoleaks and 1 chimney graft occlusion were detected within the first 30 days. Thirty-day mortality was 2.6%. Two other deaths (not aneurysm related) occurred during a mean follow-up of 21.9 months (0.23-71.3). Primary patency of the chimney grafts was 94.3% at 36 months. In a subgroup analysis comparing Endurant to other stent-grafts, no significant differences were observed regarding persistent endoleak [1/20 (5%) vs 2/19 (11%), p=0.6] or reintervention [1/20 (5%) vs 0/19 (0%)]. CONCLUSION: The present series demonstrates that chEVAR in the treatment of post-EVAR type Ia endoleaks has satisfactory results independent of the abdominal and chimney graft combinations. Midterm results show that chEVAR is an effective method for treating type Ia endoleaks.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
Ann Vasc Surg ; 46: 285-298, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28739452

RESUMO

BACKGROUND: Large gutters after chimney procedures are one of the main causes of type I endoleak (EL-I). This study aims to evaluate a new tailored planning named "Over-SIRIX," based on Osirix Imaging Software, to choose the correct main graft oversizing in order to minimize EL-I incidence. METHODS: From 2008 to 2015, 34 patients were treated with parallel grafts for aortic arch diseases at our institution. The study included 22 patients with single stent and antegrade flow configuration; they were divided into 2 groups (PRE- and POST-"Over-SIRIX"). "Over-SIRIX" was carried out in the retrospective group (PRE-"Over-SIRIX"), and it was used to plan the endovascular procedure in the prospective group (POST-"Over-SIRIX"). Through the multiplanar reconstruction (MPR) of the preoperative computed tomography angiography (CTA), the proximal neck of the chimney grafts was studied. Stent and endograft configurations were drawn in order to minimize the "gutters." To obtain the ideal main graft sizing (I-Size), a formula was used by adding the custom sizing (C-Size) to the disease oversizing (D-Over). The same MPR imaging was evaluated on postoperative CTA to study gutters area and presence of EL-I. RESULTS: The mean I-Size was 41.67 mm that was equivalent to an ideal oversizing of 19.3% (range 10-28%). The gutters area decreased from 7.3 to 1.7 mm2 (PRE/POST) and EL-I rate from 28.5% to 0% (PRE/POST). Gutters area bigger than 7.5 mm2 and planning made without "Over-SIRIX" were significantly associated (P < 0.05) to EL-I. CONCLUSIONS: "Over-SIRIX" appears to be a feasible method to customize planning during chimney technique, reducing the risk of EL-I which is significantly related to the presence and size of the gutters.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Cidade de Roma , Resultado do Tratamento
16.
J Cardiovasc Surg (Torino) ; 58(3): 422-430, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24769531

RESUMO

BACKGROUND: To report our single-center experience in the endovascular treatment of juxtarenal aorto-iliac occlusions. METHODS: Between December 2008 and December 2012, 13 patients with total juxtarenal aorto-iliac occlusion, considered at high risk for open revascularization, were treated by endovascular means at our Department. Inclusion criteria were severe intermittent claudication, rest pain and distal tissue loss. Antegrade recanalization from percutaneous brachial access and retrograde angioplasty and stenting from percutaneous or surgical femoral accesses were performed. The renal arteries (RAs) were protected using filters or balloons. Aorto-iliac bare-metal stents were deployed in all patients. RESULTS: No death was registered. Technical success was 100%. In 11 patients (84.6%) the Ankle-Brachial Index increased to 0.9-1. Renal arteries were involved in 7 cases (53.8%): 3 chimney stent grafts deployment, 2 aorto-iliac stent fenestrations and 2 aorto-iliac stents placement above the renal arteries without renal function impairment. Complication rate was 38.5%: 2 cases of thrombus dislodgement into the RAs, 1 distal artery embolization, 1 common iliac artery rupture and 1 pseudo-aneurysm. All complications were treated percutaneously, except for the distal embolization treated surgically. The patient with iliac artery rupture underwent acute renal insufficiency requiring temporary dialysis after hemorrhagic shock because of retroperitoneal hematoma. Mean follow-up was 18 months (range 6-30 months). The primary and secondary patency was respectively 92.3% and 100%. CONCLUSION: Endovascular recanalization of juxtarenal aorto-iliac occlusion in selected patients is feasible and safe, with good early and mid-term results and should be considered in high risk patients.


Assuntos
Angioplastia , Implante de Prótese Vascular , Claudicação Intermitente/cirurgia , Síndrome de Leriche/cirurgia , Adulto , Idoso , Angioplastia/efeitos adversos , Angioplastia/instrumentação , Índice Tornozelo-Braço , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Síndrome de Leriche/diagnóstico por imagem , Síndrome de Leriche/fisiopatologia , Masculino , Metais , Pessoa de Meia-Idade , Fatores de Risco , Cidade de Roma , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
J Endovasc Ther ; 23(2): 267-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26802612

RESUMO

PURPOSE: To evaluate the outcomes of carotid artery stenting (CAS) with Wallstents in a single-center experience. METHODS: From January 2003 to December 2013, 1000 carotid artery lesions were treated with Carotid Wallstents under cerebral protection in 877 patients (mean age 71.7 ± 8 years; 621 men). Indications for treatment were de novo lesions (>70% asymptomatic and >60% symptomatic); stenoses following carotid endarterectomy, radiation, or neck surgery; contralateral laryngeal nerve palsy; and high surgical risk. All the patients underwent duplex ultrasound and clinical evaluation during follow-up; radiography was performed when fracture or stent migration was suggested by ultrasound. RESULTS: Procedure success was achieved in 99.3% of patients. Major and minor 30-day adverse events occurred in 2.1% of patients, including stroke (1.8%: 1.3% minor, 0.5% major), myocardial infarction (0.1%), and death (0.2%). Plaque morphology, nature of stenosis, and symptomatic status were significantly associated with the risk of postoperative neurologic events. Restenosis occurred in 3.2% at a mean 45.5-month follow-up and was significantly associated with diabetes, smoking, symptomatic stenosis, de novo stenosis, and calcification (plaque III/IV). No fracture or migration was registered during follow-up. CONCLUSION: CAS is a valid method for treating carotid artery disease, with very low rates of major adverse events and neurologic complications. The Carotid Wallstent seems to have excellent results, even with complex plaque morphology, and a low incidence of restenosis at follow-up.


Assuntos
Angioplastia/instrumentação , Estenose das Carótidas/terapia , Vasos Coronários , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Angiografia por Tomografia Computadorizada , Vasos Coronários/diagnóstico por imagem , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica , Desenho de Prótese , Recidiva , Fatores de Risco , Cidade de Roma , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
18.
Ann Thorac Surg ; 101(6): 2224-30, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26794885

RESUMO

BACKGROUND: To study the performance of the chimney technique in the treatment of aortic arch pathologic conditions. METHODS: We retrospectively evaluated the clinical and procedural outcome data of patients undergoing endovascular treatment in the aortic arch by use of the chimney technique at four European centers between June 2002 and December 2014. The primary endpoint was technical success. The secondary endpoints were type I endoleak, 30-day mortality, stroke, primary patency of the chimney graft, and freedom from reintervention. RESULTS: Ninety-five patients were included in the study. The underlying pathologic conditions were degenerative aneurysm (n = 45, 47.4%), type B aortic dissection (n = 30, 31.6%), dissecting aneurysm (n = 6, 6.5%), penetrating atherosclerotic ulcer (n = 5, 5.3%), type I endoleak after previous thoracic endovascular aortic repair (n = 6, 6.3%), and aortic embolic disease (n = 3, 3.2%). Twenty-one patients (22%) underwent arch-branch debranching before chimney graft implantation. The majority of patients were treated electively (n = 49, 51.6%). Forty-six patients (48.4%) underwent urgent placement of chimney grafts because of their symptoms (n = 25) or rupture (n = 21). Technical success was 89.5%. The 30-day mortality was 9.5% (9 patients). No aorta-related death was observed. A type Ia endoleak occurred in 10 patients (10.5%) intraoperatively, resolving spontaneously within the first 30 days in 50% of these cases. Major stroke was diagnosed in 2 patients (2%). Primary patency of the chimney grafts was 98%, and 5 patients (5.2%) required a reintervention. CONCLUSIONS: The chimney technique in the aortic arch proved highly and predictably successful, with a low rate of reinterventions.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Sistema de Registros , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Doenças da Aorta/patologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Estudos de Coortes , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Procedimentos Cirúrgicos Eletivos/métodos , Tratamento de Emergência/métodos , Tratamento de Emergência/mortalidade , Endoleak/fisiopatologia , Endoleak/cirurgia , Procedimentos Endovasculares/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento , Adulto Jovem
19.
J Vasc Surg ; 62(6): 1437-41, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26386510

RESUMO

OBJECTIVE: The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. METHODS: Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal access, whenever possible), the technique consisted of performing a banding of the neck with Teflon (DuPont, Wilmington, Del), a sacotomy to remove the thrombus or the hygroma, or both, and then suturing all of the feeding vessels that were found. Proximal and distal fenestrations were performed to avoid sac repressurization. RESULTS: The semiconversion was performed after a mean of 74 months after the initial EVAR. The mean aneurysm size at the time of the EVAR was 6.0 cm (range, 5.0-9.5 cm), and the mean aneurysm size at the time of the semiconversion was 7.7 cm (range, 5.5-11.5 cm). The overall aneurysm size increase was 38%, and the average growth rate was 8.2% per year. One patient had a stable aneurysm size but was treated because of an emergency condition. Technical success was 100%, with resolution of the endoleak and no perioperative deaths. Four cardiac deaths were registered at 12, 26, 30, and 60 months (mean follow-up, 42 months; range, 1-80 months). CONCLUSIONS: Graft salvage appears to be a valid option compared with open repair when considering treatment of persistent type II endoleak. This case series shows that semiconversion is a safe and effective treatment for otherwise untreatable type II endoleak.


Assuntos
Implante de Prótese Vascular , Conversão para Cirurgia Aberta/métodos , Endoleak/cirurgia , Endoleak/epidemiologia , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Seleção de Pacientes
20.
J Vasc Interv Radiol ; 26(6): 842-54, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25887934

RESUMO

PURPOSE: To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. MATERIALS AND METHODS: Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with hemodynamic stability, and ch-EVAR was used in unstable cases. The study included 34 consecutive patients. Primary outcomes measured were perioperative mortality and morbidity, renal function impairment (RFI), target vessel patency, and survival at mean follow-up. RESULTS: In the CM f-EVAR group (7 of 34 patients; 20.6%), an intraoperative type III endoleak (1 of 7 patients; 14%) sealed spontaneously. At 8.9 months of follow-up, 1 (1 of 7 patients; 14%) death and 1 (1 of 7 patients; 14%) episode of transient RFI were documented. Visceral vessel patency rate was 95.2%. In the HM f-EVAR group (4 of 34 patients; 11.7%) and the combination of HM f-EVAR and ch-EVAR group (3 of 34 patients; 8.8%), no complications were observed at 17.3 months of follow-up. In the ch-EVAR group (20 of 34 patients; 58.8%), visceral patency was 95% at 30.9 months of follow-up. Two cases of transient RFI and 2 cases of permanent RFI were registered (2 of 20 patients; 10%). One asymptomatic renal artery branch occlusion was observed at 11 months of follow-up. No endoleaks were documented. CONCLUSIONS: Endovascular aneurysm repair techniques including CM f-EVAR, HM f-EVAR or HM f-EVAR in combination with ch-EVAR, and ch-EVAR are valid tools to maintain blood flow in visceral arteries during treatment of complex aortic aneurysms. The proposed interventional protocol based on clinical presentation was feasible in all cases.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Vísceras/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA