Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Magn Reson Imaging ; 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38240395

RESUMO

BACKGROUND: Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. It offers a non-invasive alternative to the current reference standard of kidney biopsy. PURPOSE: To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in the first 3-months post-transplantation. STUDY TYPE: Prospective. SUBJECTS: 32 transplant recipients (54 ± 17 years, 20 females), divided into two groups according to estimated glomerular filtration rate (eGFR) at 3-months post-transplantation: inferior graft function (IGF; eGFR<45 mL/min/1.73 m2 , n = 10) and superior graft function (SGF; eGFR ≥ 45 mL/min/1.73 m2 , n = 22). Further categorization was based on the need for hemodialysis (C1) and decrease in s-creatinine (C2) at 1-week post-transplantation: delayed-graft-function (DGF: n = 4 C1, n = 10 C2) and early graft-function (EGF: n = 28 C1, n = 22 C2). FIELD STRENGTH/SEQUENCE: 3-T, pseudo-continuous arterial spin labeling, T1-mapping, and diffusion-weighted imaging. ASSESSMENT: Multiparametric MRI was evaluated at 1-week in all patients and 3-months after transplantation in 28 patients. Renal blood flow (RBF), diffusion coefficients (ADC, ΔADC, D, ∆ $$ \Delta $$ D, D*, flowing fraction f), T1 and ∆ $$ \Delta $$ T1 were calculated in cortex and medulla. The diagnostic and prognostic value of these parameters, obtained at 3-months and 1-week post-transplantation, respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF. STATISTICAL TESTS: Logistic regression, receiver-operating-characteristics, area-under-the-curve (AUC), confidence intervals (CIs), analysis-of-variance, t-test, Wilcoxon-Mann-Whitney test, Fisher's exact test, Pearson's correlation. P-value<0.05 was considered significant. RESULTS: DGF patients exhibited significantly lower cortical RBF and f and higher D*. The diagnostic value of MRI for detecting DGF was excellent (AUC = 100%). Significant differences between patients with IGF and SGF were found in RBF, ∆T1 , and ∆D. Multiparametric MRI showed higher diagnostic (AUC = 95.32%; CI: 88%-100%) and prognostic (AUC = 97.47%, CI: 92%-100%) values for detecting IGF than eGFR (AUC = 89.50%, CI: 79%-100%). DATA CONCLUSION: Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yielding better results compared to eGFR measurements. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

2.
J Magn Reson Imaging ; 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37915245

RESUMO

BACKGROUND: There is a lack of automated tools for the segmentation and quantification of neuromelanin (NM) and iron in the nigrosome-1 (N1). Existing tools evaluate the N1 sign, i.e., the presence or absence of the "swallow-tail" in iron-sensitive MRI, or globally analyze the MRI signal in an area containing the N1, without providing a volumetric delineation. PURPOSE: Present an automated method to segment the N1 and quantify differences in N1's NM and iron content between Parkinson's disease (PD) patients and healthy controls (HCs). Study whether N1 degeneration is clinically related to PD and could be used as a biomarker of the disease. STUDY TYPE: Prospective. SUBJECTS: Seventy-one PD (65.3 ± 10.3 years old, 34 female/37 male); 30 HC (62.7 ± 7.8 years old, 17 female/13 male). FIELD STRENGTH/SEQUENCE: 3 T Anatomical T1-weighted MPRAGE, NM-MRI T1-weighted gradient with magnetization transfer, susceptibility-weighted imaging (SWI). ASSESSMENT: N1 was automatically segmented in SWI images using a multi-image atlas, populated with healthy N1 structures manually annotated by a neurologist. Relative NM and iron content were quantified and their diagnostic performance assessed and compared with the substantia nigra pars compacta (SNc). The association between image parameters and clinically relevant variables was studied. STATISTICAL TESTS: Nonparametric tests were used (Mann-Whitney's U, chi-square, and Friedman tests) at P = 0.05. RESULTS: N1's relative NM content decreased and relative iron content increased in PD patients compared with HCs (NM-CRHC = 22.55 ± 1.49; NM-CRPD = 19.79 ± 1.92; NM-nVolHC = 2.69 × 10-5 ± 1.02 × 10-5 ; NM-nVolPD = 1.18 × 10-5 ± 0.96 × 10-5 ; Iron-CRHC = 10.51 ± 2.64; Iron-CRPD = 19.35 ± 7.88; Iron-nVolHC = 0.72 × 10-5 ± 0.81 × 10-5 ; Iron-nVolPD = 2.82 × 10-5 ± 2.04 × 10-5 ). Binary logistic regression analyses combining N1 and SNc image parameters yielded a top AUC = 0.955. Significant correlation was found between most N1 parameters and both disease duration (ρNM-CR = -0.31; ρiron-CR = 0.43; ρiron-nVol = 0.46) and the motor status (ρNM-nVol = -0.27; ρiron-CR = 0.33; ρiron-nVol = 0.28), suggesting NM reduction along with iron accumulation in N1 as the disease progresses. DATA CONCLUSION: This method provides a fully automatic N1 segmentation, and the analyses performed reveal that N1 relative NM and iron quantification improves diagnostic performance and suggest a relative NM reduction along with a relative iron accumulation in N1 as the disease progresses. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.

3.
J Magn Reson Imaging ; 57(6): 1676-1695, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36912262

RESUMO

Preoperative clinical MRI protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this second part, we review magnetic resonance spectroscopy (MRS), chemical exchange saturation transfer (CEST), susceptibility-weighted imaging (SWI), MRI-PET, MR elastography (MRE), and MR-based radiomics applications. The first part of this review addresses dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) MRI, arterial spin labeling (ASL), diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting (MRF). EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Encefálicas , Glioma , Imageamento por Ressonância Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Meios de Contraste , Glioma/diagnóstico por imagem , Glioma/cirurgia , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Período Pré-Operatório
4.
NMR Biomed ; : e4938, 2023 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-36967637

RESUMO

Resection control in brain tumor surgery can be achieved in real time with intraoperative MRI (iMRI). Arterial spin labeling (ASL), a technique that measures cerebral blood flow (CBF) non-invasively without the use of intravenous contrast agents, can be performed intraoperatively, providing morpho-physiological information. This study aimed to evaluate the feasibility, image quality and potential to depict residual tumor of a pseudo-continuous ASL (PCASL) sequence at 3 T. Seventeen patients with brain tumors, primary (16) or metastatic (1), undergoing resection surgery with iMRI monitoring, were prospectively recruited (nine men, age 56 ± 16.6 years). A PCASL sequence with long labeling duration (3000 ms) and postlabeling delay (2000 ms) was added to the conventional protocol, which consisted of pre- and postcontrast 3D T1 -weighted (T1w) images, optional 3D-FLAIR, and diffusion. Three observers independently assessed the image quality (four-point scale) of PCASL-derived CBF maps. In those with diagnostic quality (Scores 2-4) they evaluated the presence of residual tumor using the conventional sequences first, and the CBF maps afterwards (three-point scale). Inter-observer agreement for image quality and the presence of residual tumor was assessed using Fleiss kappa statistics. The intraoperative CBF ratio of the surgical margins (i.e., perilesional CBF values normalized to contralateral gray matter CBF) was compared with preoperative CBF ratio within the tumor (Wilcoxon's test). Diagnostic ASL image quality was observed in 94.1% of patients (interobserver Fleiss κ = 0.76). PCASL showed additional foci suggestive of high-grade residual component in three patients, and a hyperperfused area extending outside the enhancing component in one patient. Interobserver agreement was almost perfect in the evaluation of residual tumor with the conventional sequences (Fleiss κ = 0.92) and substantial for PCASL (Fleiss κ = 0.80). No significant differences were found between pre and intraoperative CBF ratios (p = 0.578) in patients with residual tumor (n = 7). iMRI-PCASL perfusion is feasible at 3 T and is useful for the intraoperative assessment of residual tumor, providing in some cases additional information to the conventional sequences.

5.
J Magn Reson Imaging ; 57(6): 1655-1675, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36866773

RESUMO

Preoperative clinical magnetic resonance imaging (MRI) protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation or lack thereof. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this first part, we discuss dynamic susceptibility contrast and dynamic contrast-enhanced MRI, arterial spin labeling, diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting. The second part of this review addresses magnetic resonance spectroscopy, chemical exchange saturation transfer, susceptibility-weighted imaging, MRI-PET, MR elastography, and MR-based radiomics applications. Evidence Level: 3 Technical Efficacy: Stage 2.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Imageamento por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Glioma/cirurgia , Glioma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Espectroscopia de Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética
6.
J Magn Reson Imaging ; 58(1): 147-156, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36218288

RESUMO

BACKGROUND: In patients with suspected coronary artery disease (CAD), myocardial perfusion is assessed under rest and pharmacological stress to identify ischemia. Splenic switch-off, defined as the stress to rest splenic perfusion attenuation in response to adenosine, has been proposed as an indicator of stress adequacy. Its occurrence has been previously assessed in first-pass perfusion images, but the use of noncontrast techniques would be highly beneficial. PURPOSE: To explore the ability of pseudo-continuous arterial spin labeling (PCASL) to identify splenic switch-off in patients with suspected CAD. STUDY TYPE: Prospective. POPULATION: Five healthy volunteers (age 24.8 ± 3.8 years) and 32 patients (age 66.4 ± 8.2 years) with suspected CAD. FIELD STRENGTH/SEQUENCE: A 1.5-T/PCASL (spin-echo) and first-pass imaging (gradient-echo). ASSESSMENT: In healthy subjects, multi-delay PCASL data (500-2000 msec) were acquired to quantify splenic blood flow (SBF) and determine the adequate postlabeling delay (PLD) for single-delay acquisitions (PLD > arterial transit time). In patients, single-delay PCASL (1200 msec) and first-pass perfusion images were acquired under rest and adenosine conditions. PCASL data were used to compute SBF maps and SBF stress-to-rest ratios. Three observers classified patients into "switch-off" and "failed switch-off" groups by visually comparing rest-stress perfusion data acquired with PCASL and first-pass, independently. First-pass categories were used as reference to evaluate the accuracy of quantitative classification. STATISTICAL TESTS: Wilcoxon signed-rank, Pearson correlation, kappa, percentage agreement, Generalized Linear Mixed Model, Mann-Whitney, Pearson Chi-squared, receiver operating characteristic, area-under-the-curve (AUC) and confusion matrix. SIGNIFICANCE: P value < 0.05. RESULTS: A total of 27 patients (84.4%) experienced splenic switch-off according to first-pass categories. Comparison of PCASL-derived SBF maps during stress and rest allowed assessment of splenic switch-off, reflected in a reduction of SBF values during stress. SBF stress-to-rest ratios showed a 97% accuracy (sensitivity = 80%, specificity = 100%, AUC = 85.2%). DATA CONCLUSION: This study could demonstrate the feasibility of PCASL to identify splenic switch-off during adenosine perfusion MRI, both by qualitative and quantitative assessments. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: 2.


Assuntos
Adenosina , Imageamento por Ressonância Magnética , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Marcadores de Spin , Imageamento por Ressonância Magnética/métodos , Perfusão
7.
Nutrients ; 14(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36079742

RESUMO

Background: Matrix metalloproteinase-10 (MMP-10) levels increase progressively starting from early diabetic kidney disease (DKD) stages. Vitamin D3 (vitD3) deficit is associated with a higher risk of diabetic microangiopathy. Reduced MMP-10 expression has been observed after exposure to vitD3. Aim: to assess how vitD3 status is related to MMP-10 levels in patients with Type 2 diabetes (T2D). Methods: 256 patients with T2D were included in this cross-sectional study. Demographic, clinical and serum MMP-10 and 25-hydroxyvitamin D3 (25(OH)D3) levels were collected from each patient. The association between MMP-10 and (25(OH)D3) levels was assessed using a correlation analysis and fitting a multivariate linear regression model. Results: Serum MMP-10 levels were inversely correlated with circulating 25(OH)D3 (rho = −0.25; p < 0.001). In the subgroup analysis this correlation was significant in patients with DKD (rho = −0.28; p = 0.001) and in subjects with vitD3 deficit (rho = −0.24; p = 0.005). In the regression model adjusted for kidney function, body adiposity, smoking and vitD supplementation MMP-10 levels were 68.7 pg/mL lower in patients with 25(OH)D3 > 20 ng/mL, with respect to ≤20 ng/mL (p = 0.006). Conclusions: vitD3 repletion status is an independent predictor of MMP-10 levels in T2D patients. Perhaps, high 25(OH)D3 values should be targeted in these patients in order to prevent vascular complications.


Assuntos
Calcifediol , Diabetes Mellitus Tipo 2 , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Humanos , Metaloproteinase 10 da Matriz , Vitamina D/análogos & derivados , Vitaminas
8.
NMR Biomed ; 32(5): e4077, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30811728

RESUMO

The aim of this study was to improve the scan efficiency of ASL in the myocardium. Free breathing FAIR-ASL scans with different TRs were compared, while keeping the acquisition time constant. Scans were named by the trigger pulse that started each acquisition: every two (TP1), four (TP2) and six (TP3) cardiac cycles. TP2 offered the best alternative with a coefficient of variation of 17.15% intrasession and 36.85% intersession. Mean MBF increased by 0.22 ± 0.41 ml/g/min with mild stress.


Arterial spin labeling (ASL) offers a noninvasive and repeatable measurement of tissue blood flow, but its application in the human heart is still challenging. The aim of this study was to improve the scan efficiency of flow-sensitive alternating inversion recovery (FAIR) ASL using a single inversion time. First, by evaluating a free breathing acquisition without navigators. Second, by shortening TR to acquire more ASL pairs. A FAIR ASL with balanced steady state free precession (bSSFP) readout was implemented at 3 T and tested in 14 healthy volunteers. Three cardiac-triggered ASL scans with different TRs were compared while maintaining a constant acquisition time. These scans were named by the trigger pulse (TP) that started each acquisition: every two (TP1), four (TP2) and six (TP3) cardiac cycles. Two studies were performed on different days to assess the reproducibility of TP2 and TP3 scans. Perfusion response during passive leg raising was also evaluated. Student t-test and nonparametric equivalent were computed for perfusion differences. Bland-Altman and coefficient of variation (CV) were calculated for the reproducibility assessment. Mean myocardial blood flow (MBF) values measured at rest were: 1.47 ± 0.91 ml/g/min (TP1), 1.95 ± 0.93 ml/g/min (TP2) and 1.94 ± 1.41 ml/g/min (TP3). Intrasession CV was 17.15% (TP2) and 24.17% (TP3) and intersession CV was 36.86% (TP2) and 18.38% (TP3). Mean MBF was found to increase with passive stress by 0.22 ± 0.41 ml/g/min for TP2 (P = 0.037). Mean MBF values were consistent with the literature, although in the high end of the normal range. The lower MBF values measured in TP1 scans are attributable to saturation of blood outside the slice because of shorter TR. Free breathing FAIR cardiac ASL without navigators is feasible. A TR of approximately four seconds (TP2) offers the best alternative with similar mean ASL and tSNR than longer TR acquisitions.


Assuntos
Artérias/metabolismo , Miocárdio/metabolismo , Respiração , Marcadores de Spin , Adulto , Simulação por Computador , Circulação Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
9.
J Magn Reson Imaging ; 46(6): 1810-1817, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28383796

RESUMO

PURPOSE: To investigate whether arterial spin labeling (ASL) MRI could detect renal hemodynamic impairment in diabetes mellitus (DM) along different stages of chronic kidney disease (CKD). MATERIALS AND METHODS: Three Tesla (3T) ASL-MRI was performed to evaluate renal blood flow (RBF) in 91 subjects (46 healthy volunteers and 45 type 2 diabetic patients). Patients were classified according to their estimated glomerular filtration rate (eGFR) as group I (eGFR > 60 mL/min/1.73 m2 ), group II (60 ≥ eGFR>30 mL/min/1.73 m2 ), or group III (eGFR ≤ 30 mL/min/1.73 m2 ), to determine differences depending on renal function. Studies were performed at 3T using a 12-channel flexible body array combined with the spine array coil as receiver. RESULTS: A 28% reduction in cortical RBF was seen in diabetics in comparison with healthy controls (185.79 [54.60] versus 258.83 [37.96] mL/min/100 g, P < 3 × 10-6 ). Differences were also seen between controls and diabetic patients despite normal eGFR and absence of overt albuminuria (RBF [mL/min/100 g]: controls=258.83 [37.96], group I=208.89 [58.83], P = 0.0018; eGFR [mL/min/1.73 m2 ]: controls = 95.50 [12.60], group I = 82.00 [20.76], P > 0.05; albumin-creatinine ratio [mg/g]: controls = 3.50 [4.45], group I = 17.50 [21.20], P > 0.05). A marked decrease in RBF was noted a long with progression of diabetic nephropathy (DN) through the five stages of CKD (χ2 = 43.58; P = 1.85 × 10-9 ). Strong correlation (r = 0.62; P = 4 × 10-10 ) was obtained between RBF and GFR estimated by cystatin C. CONCLUSION: ASL-MRI is able to quantify early renal perfusion impairment in DM, as well as changes according to different CKD stages of DN. In addition, we demonstrated a correlation of RBF quantified by ASL and GFR estimated by cystatin C. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1810-1817.


Assuntos
Nefropatias Diabéticas/diagnóstico por imagem , Nefropatias Diabéticas/fisiopatologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Rim/diagnóstico por imagem , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Circulação Renal/fisiologia , Reprodutibilidade dos Testes , Marcadores de Spin
10.
Arch Neurol ; 66(2): 262-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19204166

RESUMO

BACKGROUND: In rare cases, adults with normal or almost normal cognition may have giant brain ventricles surrounded by a sliver of brain. Because the usual flow of cerebrospinal fluid (CSF) is interrupted in these individuals, they may develop alternative CSF pathways to preserve brain function. OBJECTIVE: To describe novel morphologic autopsy findings in a patient with chronic giant hydrocephalus that suggest the existence of alternative CSF draining pathways. DESIGN: Case report. SETTING: Autopsy study. PATIENT: A 48-year-old man with chronic compensated hydrocephalus associated with a Dandy-Walker malformation. MAIN OUTCOME MEASURE: Autopsy findings. RESULTS: We observed microscopic structures on the ventricular wall that may facilitate CSF resorption. Their histologic appearance, reminiscent of pacchionian granulations, showed the opposite relation in regard to CSF/blood compartments: whereas the core of a pacchionian granulation contains CSF and the granulation is bathed in blood of the venous sinus, the core of the ventricular granulation in our patient contained venules, with the granulation bathed in ventricular CSF. CONCLUSIONS: These previously unreported (to our knowledge) ventricular wall granulations may facilitate draining of CSF into the venous system when CSF outflow from the ventricular system is occluded. The presence of these ventricular structures illustrates biologic adaptation to anomalous conditions and successful compensation.


Assuntos
Ventrículos Cerebrais/patologia , Ventrículos Cerebrais/fisiopatologia , Líquido Cefalorraquidiano/fisiologia , Síndrome de Dandy-Walker/complicações , Hidrocefalia/patologia , Hidrocefalia/fisiopatologia , Adaptação Fisiológica/fisiologia , Adulto , Pressão do Líquido Cefalorraquidiano/fisiologia , Derivações do Líquido Cefalorraquidiano/efeitos adversos , Doença Crônica , Epêndima/citologia , Epêndima/fisiologia , Contaminação de Equipamentos , Evolução Fatal , Feminino , Tecido de Granulação/patologia , Tecido de Granulação/fisiopatologia , Humanos , Hidrocefalia/etiologia , Imageamento por Ressonância Magnética , Masculino , Meningites Bacterianas , Pessoa de Meia-Idade , Vênulas/citologia , Vênulas/fisiologia
11.
J Cereb Blood Flow Metab ; 27(4): 839-49, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16969383

RESUMO

Quantification of water permeability can improve the accuracy of perfusion measurements obtained with arterial spin labeling (ASL) methods, and may provide clinically relevant information regarding the functional status of the microvasculature. The amount of labeled water in the vascular and tissue compartments in an ASL experiment can be estimated based on their distinct diffusion characteristics, and in turn, water permeability determined from the relative vascular and tissue contributions. In the present study, a hybrid magnetic resonance imaging technique was introduced by marrying a continuous ASL method with a twice-refocused spin-echo diffusion sequence. Series of diffusion-weighted ASL signals were acquired with systematically varied b values. The signals were modeled with fast and slow decaying components that were associated with the vascular and tissue compartments, respectively. The relative amount of labeled water in the tissue compartment increased from 61% to 74% and to 86% when the postlabeling delay time was increased from 0.8 to 1.2 and to 1.5 secs. With a b value of 50 secs/mm2, the capillary contribution (fast component) of the ASL signal could be effectively minimized. Using the single-pass approximation model, the water permeability of gray matter in the human brain was estimated based on the derived relative water fractions in the tissue and microvasculature. The potential for in vivo magnetic resonance mapping of water permeability was showed using two diffusion weighted ASL measurements with b=0 and 50 secs/mm2 in both healthy subjects and a case of brain tumor.


Assuntos
Água Corporal/fisiologia , Química Encefálica/fisiologia , Circulação Cerebrovascular/fisiologia , Adulto , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Simulação por Computador , Interpretação Estatística de Dados , Difusão , Imagem de Difusão por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Modelos Neurológicos , Oligodendroglioma/metabolismo , Oligodendroglioma/patologia , Perfusão , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA