Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Healthc Technol Lett ; 11(2-3): 101-107, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638490

RESUMO

Recent research studies reported that the employment of wearable augmented reality (AR) systems such as head-mounted displays for the in situ visualisation of ultrasound (US) images can improve the outcomes of US-guided biopsies through reduced procedure completion times and improved accuracy. Here, the authors continue in the direction of recent developments and present the first AR system for guiding an in-depth tumour enucleation procedure under US guidance. The system features an innovative visualisation modality with cutting trajectories that 'sink' into the tissue according to the depth reached by the electric scalpel, tracked in real-time, and a virtual-to-virtual alignment between the scalpel's tip and the trajectory. The system has high accuracy in estimating the scalpel's tip position (mean depth error of 0.4 mm and mean radial error of 1.34 mm). Furthermore, we demonstrated with a preliminary user study that our system allowed us to successfully guide an in-depth tumour enucleation procedure (i.e. preserving the safety margin around the lesion).

2.
IEEE J Transl Eng Health Med ; 12: 258-267, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410181

RESUMO

Achieving and maintaining proper image registration accuracy is an open challenge of image-guided surgery. This work explores and assesses the efficacy of a registration sanity check method for augmented reality-guided navigation (AR-RSC), based on the visual inspection of virtual 3D models of landmarks. We analyze the AR-RSC sensitivity and specificity by recruiting 36 subjects to assess the registration accuracy of a set of 114 AR images generated from camera images acquired during an AR-guided orthognathic intervention. Translational or rotational errors of known magnitude up to ±1.5 mm/±15.5°, were artificially added to the image set in order to simulate different registration errors. This study analyses the performance of AR-RSC when varying (1) the virtual models selected for misalignment evaluation (e. g., the model of brackets, incisor teeth, and gingival margins in our experiment), (2) the type (translation/rotation) of registration error, and (3) the level of user experience in using AR technologies. Results show that: 1) the sensitivity and specificity of the AR-RSC depends on the virtual models (globally, a median true positive rate of up to 79.2% was reached with brackets, and a median true negative rate of up to 64.3% with incisor teeth), 2) there are error components that are more difficult to identify visually, 3) the level of user experience does not affect the method. In conclusion, the proposed AR-RSC, tested also in the operating room, could represent an efficient method to monitor and optimize the registration accuracy during the intervention, but special attention should be paid to the selection of the AR data chosen for the visual inspection of the registration accuracy.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Salas Cirúrgicas , Imagens de Fantasmas
3.
Healthcare (Basel) ; 11(19)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37830669

RESUMO

Giant Cell Tumor of Bone is a benign tumor with high local aggressive expansion, which, in rare cases, spreads metastasis. Surgical treatment, which often consists of wide curettage to reduce recurrence risk, can lower the quality of life for those affected. Along with aggressive surgery, adjuvant intraoperative techniques have been implemented such as PMMA and cryotherapy. One of the most widely used cryotherapy techniques involves the use of probes to generate ice balls, which have been scientifically shown to have various impacts on the tumor. Although this has been acknowledged, no one has yet tested a way to accurately plan the positioning of cryotherapy probes before surgery, according to the research conducted by the authors. CRIO2AR is a randomized clinical prospective ongoing study by which it will be experimented via preoperative planning of ice probes placement using AR and 3D printing technologies. By studying a single clinical case with these technologies, the surgeon gains better awareness of patient's anatomy and tumor localization. Preliminary results are shown in the article. The first results are confirming that these technologies are applicable in clinical practice. Secondly, preoperative planning is proving to be reliable, easily replicable, and useful for the surgeon.

4.
Bioengineering (Basel) ; 10(5)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37237631

RESUMO

This study aims to critically analyse the workflow of the in situ bioprinting procedure, presenting a simulated neurosurgical case study, based on a real traumatic event, for collecting quantitative data in support of this innovative approach. After a traumatic event involving the head, bone fragments may have to be removed and a replacement implant placed through a highly demanding surgical procedure in terms of surgeon dexterity. A promising alternative to the current surgical technique is the use of a robotic arm to deposit the biomaterials directly onto the damaged site of the patient following a planned curved surface, which can be designed pre-operatively. Here we achieved an accurate planning-patient registration through pre-operative fiducial markers positioned around the surgical area, reconstructed starting from computed tomography images. Exploiting the availability of multiple degrees of freedom for the regeneration of complex and also overhanging parts typical of anatomical defects, in this work the robotic platform IMAGObot was used to regenerate a cranial defect on a patient-specific phantom. The in situ bioprinting process was then successfully performed showing the great potential of this innovative technology in the field of cranial surgery. In particular, the accuracy of the deposition process was quantified, as well as the duration of the whole procedure was compared to a standard surgical practice. Further investigations include a biological characterisation over time of the printed construct as well as an in vitro and in vivo analysis of the proposed approach, to better analyse the biomaterial performances in terms of osteo-integration with the native tissue.

5.
Sensors (Basel) ; 23(6)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36991751

RESUMO

The adoption of extended reality solutions is growing rapidly in the healthcare world. Augmented reality (AR) and virtual reality (VR) interfaces can bring advantages in various medical-health sectors; it is thus not surprising that the medical MR market is among the fastest-growing ones. The present study reports on a comparison between two of the most popular MR head-mounted displays, Magic Leap 1 and Microsoft HoloLens 2, for the visualization of 3D medical imaging data. We evaluate the functionalities and performance of both devices through a user-study in which surgeons and residents assessed the visualization of 3D computer-generated anatomical models. The digital content is obtained through a dedicated medical imaging suite (Verima imaging suite) developed by the Italian start-up company (Witapp s.r.l.). According to our performance analysis in terms of frame rate, there are no significant differences between the two devices. The surgical staff expressed a clear preference for Magic Leap 1, particularly for the better visualization quality and the ease of interaction with the 3D virtual content. Nonetheless, even though the results of the questionnaire were slightly more positive for Magic Leap 1, the spatial understanding of the 3D anatomical model in terms of depth relations and spatial arrangement was positively evaluated for both devices.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Realidade Virtual , Humanos , Simulação por Computador , Cirurgia Assistida por Computador/métodos , Imageamento Tridimensional
6.
IEEE Trans Robot ; 39(6): 4500-4519, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38249319

RESUMO

Aortic valve surgery is the preferred procedure for replacing a damaged valve with an artificial one. The ValveTech robotic platform comprises a flexible articulated manipulator and surgical interface supporting the effective delivery of an artificial valve by teleoperation and endoscopic vision. This article presents our recent work on force-perceptive, safe, semiautonomous navigation of the ValveTech platform prior to valve implantation. First, we present a force observer that transfers forces from the manipulator body and tip to a haptic interface. Second, we demonstrate how hybrid forward/inverse mechanics, together with endoscopic visual servoing, lead to autonomous valve positioning. Benchtop experiments and an artificial phantom quantify the performance of the developed robot controller and navigator. Valves can be autonomously delivered with a 2.0±0.5 mm position error and a minimal misalignment of 3.4±0.9°. The hybrid force/shape observer (FSO) algorithm was able to predict distributed external forces on the articulated manipulator body with an average error of 0.09 N. FSO can also estimate loads on the tip with an average accuracy of 3.3%. The presented system can lead to better patient care, delivery outcome, and surgeon comfort during aortic valve surgery, without requiring sensorization of the robot tip, and therefore obviating miniaturization constraints.

7.
Artigo em Inglês | MEDLINE | ID: mdl-35627884

RESUMO

In recent years, huge progress has been made in the management of brain tumors, due to the availability of imaging devices, which provide fundamental anatomical and pathological information not only for diagnostic purposes [...].


Assuntos
Realidade Aumentada , Neoplasias Encefálicas , Cirurgia Assistida por Computador , Neoplasias Encefálicas/diagnóstico por imagem , Previsões , Humanos
8.
IEEE Trans Vis Comput Graph ; 28(3): 1608-1618, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-32881688

RESUMO

Egocentric augmented reality (AR) interfaces are quickly becoming a key asset for assisting high precision activities in the peripersonal space in several application fields. In these applications, accurate and robust registration of computer-generated information to the real scene is hard to achieve with traditional Optical See-Through (OST) displays given that it relies on the accurate calibration of the combined eye-display projection model. The calibration is required to efficiently estimate the projection parameters of the pinhole model that encapsulate the optical features of the display and whose values vary according to the position of the user's eye. In this article, we describe an approach that prevents any parallax-related AR misregistration at a pre-defined working distance in OST displays with infinity focus; our strategy relies on the use of a magnifier placed in front of the OST display, and features a proper parameterization of the virtual rendering camera achieved through a dedicated calibration procedure that accounts for the contribution of the magnifier. We model the registration error due to the viewpoint parallax outside the ideal working distance. Finally, we validate our strategy on a OST display, and we show that sub-millimetric registration accuracy can be achieved for working distances of ±100 mm around the focal length of the magnifier.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Calibragem , Gráficos por Computador , Espaço Pessoal , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador
9.
Artigo em Inglês | MEDLINE | ID: mdl-34639256

RESUMO

BACKGROUND: This report discusses the utility of a wearable augmented reality platform in neurosurgery for parasagittal and convexity en plaque meningiomas with bone flap removal and custom-made cranioplasty. METHODS: A real patient with en plaque cranial vault meningioma with diffuse and extensive dural involvement, extracranial extension into the calvarium, and homogeneous contrast enhancement on gadolinium-enhanced T1-weighted MRI, was selected for this case study. A patient-specific manikin was designed starting with the segmentation of the patient's preoperative MRI images to simulate a craniotomy procedure. Surgical planning was performed according to the segmented anatomy, and customized bone flaps were designed accordingly. During the surgical simulation stage, the VOSTARS head-mounted display was used to accurately display the planned craniotomy trajectory over the manikin skull. The precision of the craniotomy was assessed based on the evaluation of previously prepared custom-made bone flaps. RESULTS: A bone flap with a radius 0.5 mm smaller than the radius of an ideal craniotomy fitted perfectly over the performed craniotomy, demonstrating an error of less than ±1 mm in the task execution. The results of this laboratory-based experiment suggest that the proposed augmented reality platform helps in simulating convexity en plaque meningioma resection and custom-made cranioplasty, as carefully planned in the preoperative phase. CONCLUSIONS: Augmented reality head-mounted displays have the potential to be a useful adjunct in tumor surgical resection, cranial vault lesion craniotomy and also skull base surgery, but more study with large series is needed.


Assuntos
Realidade Aumentada , Neoplasias Meníngeas , Meningioma , Craniotomia , Humanos , Laboratórios , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/cirurgia , Meningioma/diagnóstico por imagem , Meningioma/cirurgia
10.
Bioengineering (Basel) ; 8(10)2021 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-34677204

RESUMO

Augmented Reality (AR) headsets have become the most ergonomic and efficient visualization devices to support complex manual tasks performed under direct vision. Their ability to provide hands-free interaction with the augmented scene makes them perfect for manual procedures such as surgery. This study demonstrates the reliability of an AR head-mounted display (HMD), conceived for surgical guidance, in navigating in-depth high-precision manual tasks guided by a 3D ultrasound imaging system. The integration between the AR visualization system and the ultrasound imaging system provides the surgeon with real-time intra-operative information on unexposed soft tissues that are spatially registered with the surrounding anatomic structures. The efficacy of the AR guiding system was quantitatively assessed with an in vitro study simulating a biopsy intervention aimed at determining the level of accuracy achievable. In the experiments, 10 subjects were asked to perform the biopsy on four spherical lesions of decreasing sizes (10, 7, 5, and 3 mm). The experimental results showed that 80% of the subjects were able to successfully perform the biopsy on the 5 mm lesion, with a 2.5 mm system accuracy. The results confirmed that the proposed integrated system can be used for navigation during in-depth high-precision manual tasks.

11.
Sensors (Basel) ; 21(13)2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34209748

RESUMO

Cryosurgery is a technique of growing popularity involving tissue ablation under controlled freezing. Technological advancement of devices along with surgical technique improvements have turned cryosurgery from an experimental to an established option for treating several diseases. However, cryosurgery is still limited by inaccurate planning based primarily on 2D visualization of the patient's preoperative images. Several works have been aimed at modelling cryoablation through heat transfer simulations; however, most software applications do not meet some key requirements for clinical routine use, such as high computational speed and user-friendliness. This work aims to develop an intuitive platform for anatomical understanding and pre-operative planning by integrating the information content of radiological images and cryoprobe specifications either in a 3D virtual environment (desktop application) or in a hybrid simulator, which exploits the potential of the 3D printing and augmented reality functionalities of Microsoft HoloLens. The proposed platform was preliminarily validated for the retrospective planning/simulation of two surgical cases. Results suggest that the platform is easy and quick to learn and could be used in clinical practice to improve anatomical understanding, to make surgical planning easier than the traditional method, and to strengthen the memorization of surgical planning.


Assuntos
Realidade Aumentada , Criocirurgia , Simulação por Computador , Humanos , Estudos Retrospectivos , Software
12.
Ann Biomed Eng ; 49(9): 2590-2605, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34297263

RESUMO

Today, neuronavigation is widely used in daily clinical routine to perform safe and efficient surgery. Augmented reality (AR) interfaces can provide anatomical models and preoperative planning contextually blended with the real surgical scenario, overcoming the limitations of traditional neuronavigators. This study aims to demonstrate the reliability of a new-concept AR headset in navigating complex craniotomies. Moreover, we aim to prove the efficacy of a patient-specific template-based methodology for fast, non-invasive, and fully automatic planning-to-patient registration. The AR platform navigation performance was assessed with an in-vitro study whose goal was twofold: to measure the real-to-virtual 3D target visualization error (TVE), and assess the navigation accuracy through a user study involving 10 subjects in tracing a complex craniotomy. The feasibility of the template-based registration was preliminarily tested on a volunteer. The TVE mean and standard deviation were 1.3 and 0.6 mm. The results of the user study, over 30 traced craniotomies, showed that 97% of the trajectory length was traced within an error margin of 1.5 mm, and 92% within a margin of 1 mm. The in-vivo test confirmed the feasibility and reliability of the patient-specific template for registration. The proposed AR headset allows ergonomic and intuitive fruition of preoperative planning, and it can represent a valid option to support neurosurgical tasks.


Assuntos
Realidade Aumentada , Craniotomia/métodos , Neurocirurgia/métodos , Dispositivos Eletrônicos Vestíveis , Adulto , Craniotomia/instrumentação , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neurocirurgia/instrumentação , Imagens de Fantasmas , Crânio/diagnóstico por imagem , Crânio/cirurgia
13.
IEEE Trans Biomed Eng ; 68(4): 1238-1249, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32931426

RESUMO

OBJECTIVE: Aortic valve disease is the most common heart disease in the elderly calling for replacement with an artificial valve. The presented surgical robot aims to provide a highly controllable instrument for efficient delivery of an artificial valve by the help of integrated endoscopic vision. METHODS: A robot (called ValveTech), intended for minimally invasive surgery (MIS) and consisting of a flexible cable driven manipulator, a passive arm, and a control unit has been designed and prototyped. The flexible manipulator has several features (e.g., stabilizing flaps, tiny cameras, dexterous introducer and custom cartridge) to help the proper valve placement. It provides 5 degrees of freedom for reaching the operative site via mini-thoracotomy; it adjusts the valve and expands it at the optimal position. The robot was evaluated by ten cardiac surgeons following a real surgical scenario in artificial chest simulator with an aortic mockup. Moreover, after each delivery, the expanded valve was evaluated objectively in comparison with the ideal position. RESULTS: The robot performances were evaluated positively by surgeons. The trials resulted in faster delivery and an average misalignment distance of 3.8 mm along the aorta axis; 16.3 degrees rotational angle around aorta axis and 8.8 degrees misalignment of the valve commissure plane to the ideal plane were measured. CONCLUSION: The trials successfully proved the proposed system for valve delivery under endoscopic vision. SIGNIFICANCE: The ValveTech robot can be an alternative solution for minimally invasive aortic valve surgery and improve the quality of the operation both for surgeons and patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos Robóticos , Robótica , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Resultado do Tratamento
14.
J Clin Med ; 9(11)2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33167432

RESUMO

BACKGROUND: In the context of guided surgery, augmented reality (AR) represents a groundbreaking improvement. The Video and Optical See-Through Augmented Reality Surgical System (VOSTARS) is a new AR wearable head-mounted display (HMD), recently developed as an advanced navigation tool for maxillofacial and plastic surgery and other non-endoscopic surgeries. In this study, we report results of phantom tests with VOSTARS aimed to evaluate its feasibility and accuracy in performing maxillofacial surgical tasks. METHODS: An early prototype of VOSTARS was used. Le Fort 1 osteotomy was selected as the experimental task to be performed under VOSTARS guidance. A dedicated set-up was prepared, including the design of a maxillofacial phantom, an ad hoc tracker anchored to the occlusal splint, and cutting templates for accuracy assessment. Both qualitative and quantitative assessments were carried out. RESULTS: VOSTARS, used in combination with the designed maxilla tracker, showed excellent tracking robustness under operating room lighting. Accuracy tests showed that 100% of Le Fort 1 trajectories were traced with an accuracy of ±1.0 mm, and on average, 88% of the trajectory's length was within ±0.5 mm accuracy. CONCLUSIONS: Our preliminary results suggest that the VOSTARS system can be a feasible and accurate solution for guiding maxillofacial surgical tasks, paving the way to its validation in clinical trials and for a wide spectrum of maxillofacial applications.

15.
Sensors (Basel) ; 20(6)2020 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-32183212

RESUMO

Augmented reality (AR) Head-Mounted Displays (HMDs) are emerging as the most efficient output medium to support manual tasks performed under direct vision. Despite that, technological and human-factor limitations still hinder their routine use for aiding high-precision manual tasks in the peripersonal space. To overcome such limitations, in this work, we show the results of a user study aimed to validate qualitatively and quantitatively a recently developed AR platform specifically conceived for guiding complex 3D trajectory tracing tasks. The AR platform comprises a new-concept AR video see-through (VST) HMD and a dedicated software framework for the effective deployment of the AR application. In the experiments, the subjects were asked to perform 3D trajectory tracing tasks on 3D-printed replica of planar structures or more elaborated bony anatomies. The accuracy of the trajectories traced by the subjects was evaluated by using templates designed ad hoc to match the surface of the phantoms. The quantitative results suggest that the AR platform could be used to guide high-precision tasks: on average more than 94% of the traced trajectories stayed within an error margin lower than 1 mm. The results confirm that the proposed AR platform will boost the profitable adoption of AR HMDs to guide high precision manual tasks in the peripersonal space.


Assuntos
Realidade Aumentada , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Dispositivos Eletrônicos Vestíveis , Gráficos por Computador , Humanos , Cirurgia Assistida por Computador/tendências , Interface Usuário-Computador , Gravação em Vídeo
17.
J Healthc Eng ; 2019: 5613931, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31316742

RESUMO

Aortic valve replacement is the only definitive treatment for aortic stenosis, a highly prevalent condition in elderly population. Minimally invasive surgery brought numerous benefits to this intervention, and robotics recently provided additional improvements in terms of telemanipulation, motion scaling, and smaller incisions. Difficulties in obtaining a clear and wide field of vision is a major challenge in minimally invasive aortic valve surgery: surgeon orientates with difficulty because of lack of direct view and limited spaces. This work focuses on the development of a computer vision methodology, for a three-eyed endoscopic vision system, to ease minimally invasive instrument guidance during aortic valve surgery. Specifically, it presents an efficient image stitching method to improve spatial awareness and overcome the orientation problems which arise when cameras are decentralized with respect to the main axis of the aorta and are nonparallel oriented. The proposed approach was tested for the navigation of an innovative robotic system for minimally invasive valve surgery. Based on the specific geometry of the setup and the intrinsic parameters of the three cameras, we estimate the proper plane-induced homographic transformation that merges the views of the operatory site plane into a single stitched image. To evaluate the deviation from the image correct alignment, we performed quantitative tests by stitching a chessboard pattern. The tests showed a minimum error with respect to the image size of 0.46 ± 0.15% measured at the homography distance of 40 mm and a maximum error of 6.09 ± 0.23% at the maximum offset of 10 mm. Three experienced surgeons in aortic valve replacement by mini-sternotomy and mini-thoracotomy performed experimental tests based on the comparison of navigation and orientation capabilities in a silicone aorta with and without stitched image. The tests showed that the stitched image allows for good orientation and navigation within the aorta, and furthermore, it provides more safety while releasing the valve than driving from the three separate views. The average processing time for the stitching of three views into one image is 12.6 ms, proving that the method is not computationally expensive, thus leaving space for further real-time processing.


Assuntos
Endoscópios , Endoscopia , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Valva Aórtica/cirurgia , Endoscopia/instrumentação , Endoscopia/métodos , Desenho de Equipamento , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Esternotomia/métodos , Toracotomia/métodos
18.
Int Urogynecol J ; 30(5): 725-731, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-29959466

RESUMO

BACKGROUND: Minimally-invasive sacrocolpopexy is the gold standard procedure for advanced apical prolapse. Nonetheless, sacrocolpopexy has potential serious complications leading many surgeons to avoid this excellent surgical procedure. To overcome these limitations, preoperative planning with 3D models of the female pelvis is proposed. The aim of the study is to evaluate the feasibility of pelvic anatomy reconstruction with the ITK-SNAP software and highlight its potential benefits in this intervention. METHODS: Thirty patient-specific 3D models of the female pelvis were created using ITK-SNAP and the EndoCAS Segmentation Pipeline extension for image segmentation: contrast-enhanced computed tomography (CE-CT) data sets of women who underwent examinations for reasons other than prolapse were used. The distances of pelvic structures from the sacral promontory were standardised and measured, and correlations among these distances were evaluated with Spearman's correlation coefficient. RESULTS: Pelvic anatomy reconstruction was feasible for all CE-CT data sets. A statistically significant correlation was found between the distances of the cava bifurcation and common iliac vessels from the sacral promontory. An area for proximal mesh attachment was defined: it is free from the passage of iliac vessels in 97.5% of cases. A significant statistical correlation was found between the distances of the midpoint of the bispinous diameter and the uterine cervix from the sacral promontory; a process of linear regression showed that the latter measure can be estimated by multiplying the first one by 0.86. CONCLUSIONS: Pre-surgical 3D reconstructions of the female pelvis using ITK-SNAP could help achieve widespread use of sacrocolpopexy: further comparative studies are needed to evaluate the outcomes with and without their use.


Assuntos
Imageamento Tridimensional/instrumentação , Pelve/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Feminino , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Humanos , Imageamento Tridimensional/normas , Laparoscopia/efeitos adversos , Prolapso de Órgão Pélvico/cirurgia , Período Pré-Operatório
19.
J Healthc Eng ; 2018: 5435097, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30515284

RESUMO

Orthopaedic simulators are popular in innovative surgical training programs, where trainees gain procedural experience in a safe and controlled environment. Recent studies suggest that an ideal simulator should combine haptic, visual, and audio technology to create an immersive training environment. This article explores the potentialities of mixed-reality using the HoloLens to develop a hybrid training system for orthopaedic open surgery. Hip arthroplasty, one of the most common orthopaedic procedures, was chosen as a benchmark to evaluate the proposed system. Patient-specific anatomical 3D models were extracted from a patient computed tomography to implement the virtual content and to fabricate the physical components of the simulator. Rapid prototyping was used to create synthetic bones. The Vuforia SDK was utilized to register virtual and physical contents. The Unity3D game engine was employed to develop the software allowing interactions with the virtual content using head movements, gestures, and voice commands. Quantitative tests were performed to estimate the accuracy of the system by evaluating the perceived position of augmented reality targets. Mean and maximum errors matched the requirements of the target application. Qualitative tests were carried out to evaluate workload and usability of the HoloLens for our orthopaedic simulator, considering visual and audio perception and interaction and ergonomics issues. The perceived overall workload was low, and the self-assessed performance was considered satisfactory. Visual and audio perception and gesture and voice interactions obtained a positive feedback. Postural discomfort and visual fatigue obtained a nonnegative evaluation for a simulation session of 40 minutes. These results encourage using mixed-reality to implement a hybrid simulator for orthopaedic open surgery. An optimal design of the simulation tasks and equipment setup is required to minimize the user discomfort. Future works will include Face Validity, Content Validity, and Construct Validity to complete the assessment of the hip arthroplasty simulator.


Assuntos
Informática Médica/métodos , Equipamentos Ortopédicos , Procedimentos Ortopédicos , Simulação de Paciente , Acetábulo/fisiologia , Adulto , Artroplastia de Quadril/métodos , Calibragem , Competência Clínica , Simulação por Computador , Feminino , Humanos , Imageamento Tridimensional , Masculino , Modelos Anatômicos , Software , Interface Usuário-Computador
20.
Updates Surg ; 70(3): 407-413, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30121846

RESUMO

In non-urban scenarios: rural areas or small cities, there is often a limited access to specialistic healthcare due to the inherent challenges associated with recruitment, retention, and access to healthcare professionals. Telemedicine is an economical and effective way to address this problem. In this research, we developed a framework for real-time communication during ultrasound examination that combines interaction via standard video conference protocols and basic AR functionalities (commercial) and a custom-developed application. The tele-ultrasonographic platform has been installed in a rural hospital in the Tuscan Apennines, and was tested on 12 patients. The study explores the utility of the system from the local and remote clinician perspectives. The results obtained provide valuable insight: the platform and the telemedicine paradigm can reduce the costs related to the necessity to move critical patients when there is a need for a specialist second opinion. Moreover, the possibility of having an expert guiding and commenting on the fly the diagnostic examination has also a didactic power, and thus allows the local less specialized clinicians to grow in competencies over time.


Assuntos
Encaminhamento e Consulta , Consulta Remota , Ultrassonografia/métodos , Humanos , Consulta Remota/instrumentação , Consulta Remota/métodos , Ultrassonografia/instrumentação , Comunicação por Videoconferência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA