Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Hand (N Y) ; 18(2): 214-221, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-33834864

RESUMO

BACKGROUND: This study sought to investigate complication rates/perioperative metrics after endoscopic carpal tunnel release (eCTR) via wide-awake, local anesthesia, no tourniquet (WALANT) versus sedation or local anesthesia with a tourniquet. METHODS: Patients aged 18 years or older who underwent an eCTR between April 28, 2018, and December 31, 2019, by 1 of 2 fellowship-trained surgeons at our single institution were retrospectively reviewed. Patients were divided into 3 groups: monitored anesthesia care with tourniquet (MT), local anesthesia with tourniquet (LT), and WALANT. RESULTS: Inclusion criteria were met by 156 cases; 53 (34%) were performed under MT, 25 (16%) under LT, and 78 (50%) under WALANT. The MT group (46.1 ± 9.7) was statistically younger compared with LT (56.3 ± 14.1, P = .007) and WALANT groups (53.5 ± 15.8, P = .008), F(2, 153) = 6.465, P = .002. Wide-awake, local anesthesia, no tourniquet had decreased procedural times (10 minutes, SD: 2) compared with MT (11 minutes, SD: 2) and LT (11 minutes, SD: 2), F(2, 153) = 5.732, P = .004). Trends favored WALANT over MT and LT for average operating room time (20 minutes, SD: 3 vs 32 minutes, SD: 6 vs 23 minutes, SD: 3, respectively, F(2, 153) = 101.1, P < .001), postanesthesia care unit time (12 minutes, SD: 7 vs 1:12 minutes, SD: 26 vs 20 minutes, SD: 22, respectively, F(2, 153) =171.1, P < .001), and door-to-door time (1:37 minutes, SD: 21 vs 2:51 minutes, SD: 40 vs 1:46 minutes, SD: 33, respectively, F(2, 153) = 109.3, P < .001). There were no differences in complication rates. CONCLUSIONS: Our data suggest favorable trends for patients undergoing eCTR via WALANT versus MT versus LT.


Assuntos
Anestesia Local , Síndrome do Túnel Carpal , Humanos , Anestesia Local/métodos , Estudos Retrospectivos , Síndrome do Túnel Carpal/cirurgia , Vigília , Torniquetes
2.
J Hand Surg Am ; 2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-35963796

RESUMO

PURPOSE: Despite their clinical importance in maintaining the stability of the pinch mechanism, injuries of the radial collateral ligament (RCL) of the index finger may be underrecognized and underreported. The purpose of this biomechanical study was to compare the repair of index finger RCL tears with either a standard suture anchor or suture tape augmentation. METHODS: The index fingers from 24 fresh-frozen human cadavers underwent repair of torn RCLs using either a standard suture anchor or suture tape augmentation. Following the repairs, the initial displacement of the repair with a 3-N ulnar deviating load was evaluated. Next, the change in displacement (cyclic deformation) of the repair after 1,000 cycles of 3 N of ulnar deviating force was calculated (displacement of the 1000th cycle - displacement of the first cycle). Finally, the amount of force required to cause clinical failure (30° ulnar deviation) of the repair was determined. RESULTS: Suture tape augmentation repairs displayed significantly less cyclic deformation (0.8 ± 0.5 mm) after cyclic loading than suture anchor repairs (1.8 ± 0.7 mm). There was no significant difference in the force required to cause the clinical failure of the repairs between the suture tape (35.1 ± 18.1 N) and suture anchor (24.5 ± 9.2 N) repairs. CONCLUSIONS: Index finger RCL repair with suture tape augmentation results in decreased deformation with repetitive motion compared with RCL repair alone. CLINICAL RELEVANCE: Suture tape augmentation may allow for early mobilization following index finger RCL repair by acting as a brace that protects the repaired ligament from deforming forces.

3.
Hand (N Y) ; 14(5): 664-668, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-29619888

RESUMO

Background: Osteoarthritis of the proximal interphalangeal (PIP) joint affects a large percentage of the population and can lead to significant functional disability. The purpose of this study is to evaluate the midterm clinical effectiveness of PIP joint arthroplasty for nonrheumatic arthritis. Methods: A single-center retrospective cohort study evaluating preoperative and postoperative objective and subjective measures was conducted. Range of motion (ROM), Disabilities of the Arm, Shoulder and Hand scores, key pinch strength, grip strength, and satisfaction with respect to pain, deformity, function, and strength were measured. Results: Forty-five fingers in 25 patients were followed up for a mean period of 42 months. Preoperative and postoperative mean ROM was equivalent at 59.1° and 59.2°, respectively. Postoperative grip and key pinch strength showed significant improvement and near normalization compared with contralateral extremity. Complication rate was 37% with 20% requiring revision surgery. Patients with diabetes mellitus had higher odds of requiring revision surgery. Pain scores improved from 7.4 to 1.9 on a visual analog scale. Overall satisfaction was high at 84%, and 91% of patients would have the surgery performed again. Conclusions: Silicone arthroplasty for osteoarthritis of the PIP remains a good option for pain relief. Our study presents midterm follow-up data that support significant pain relief, increased grip and key pinch strength, and high satisfaction associated with this implant.


Assuntos
Artroplastia de Substituição de Dedo/instrumentação , Articulações dos Dedos/cirurgia , Prótese Articular , Osteoartrite/cirurgia , Desenho de Prótese , Adulto , Artroplastia de Substituição de Dedo/métodos , Avaliação da Deficiência , Feminino , Articulações dos Dedos/fisiopatologia , Força da Mão , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Medição da Dor , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Silicones , Resultado do Tratamento
5.
Arthroscopy ; 28(9): 1230-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22560485

RESUMO

PURPOSE: To evaluate the effect of entry and exit points of the coracoid tunnel on load to failure and mode of failure, to reduce the incidence of coracoid fractures and acromioclavicular joint repair failures. METHODS: This study investigates 5 tunnel placements based on different entry and exit points in the coracoid process: center-center orientation represents perfect placement of the bone tunnel and served as perfect tunnel placement in our study. Four common errors in drilling were then tested and acted as the experimental groups in our study (medial-center, center-medial, lateral-center, and center-lateral). Using 35 cadaveric shoulders (mean age, 68.0 ± 13.0 years), we tested these 5 tunnel orientations using a single repair technique (cortical button) loaded to failure on an MTS 858 Servohydraulic test system (MTS Systems, Eden Prairie, MN). A control group of 7 cadaveric shoulders without the presence of a coracoid tunnel was also tested to determine the type of fracture pattern that occurred. RESULTS: The coracoids without tunnel drilling fractured in patterns similar to traumatic coracoid injuries. With regard to the 5 tunnel groups, it was found that the loads to failure with center-center and medial-center tunnel placement were significantly higher than those with center-medial, center-lateral, and lateral-center tunnel placement. The failure modes of the former were primarily within the repair constructs, whereas those of the latter were primarily due to bony failure. CONCLUSIONS: Our biomechanical results showed a higher peak load to failure with a center-center or medial-center tunnel orientation, which may lessen the risk of coracoid fracture during drilling with a 6-mm cannulated drill bit. CLINICAL RELEVANCE: Proper trajectory of the drill during formation of a coracoid bone tunnel can help reduce the risk of coracoid process fracture and repair failure.


Assuntos
Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/cirurgia , Fraturas Ósseas/prevenção & controle , Luxações Articulares/cirurgia , Escápula/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Humanos , Pessoa de Meia-Idade , Escápula/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA