Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Abdom Radiol (NY) ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38763936

RESUMO

Ultrasound (US) is the imaging modality of choice for evaluation of superficial palpable lesions. A large proportion of these lesions have characteristic sonographic appearance and can be confidently diagnosed with US without the need for biopsy or other intervention. The Society of Radiologists in Ultrasound (SRU) recently published a Consensus Conference Statement on superficial soft tissue masses. The goal of this manuscript is (a) to serve as a sonographic pictorial review for palpable lesions based on the SRU statement, (b) present the typical sonographic features of palpable lesions that can be confidently diagnosed with US, and (c) provide an overview of other palpable lesions with a framework to interpret the US studies and advise on appropriate further management.

2.
Radiology ; 311(2): e232369, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805727

RESUMO

The American College of Radiology Liver Imaging Reporting and Data System (LI-RADS) standardizes the imaging technique, reporting lexicon, disease categorization, and management for patients with or at risk for hepatocellular carcinoma (HCC). LI-RADS encompasses HCC surveillance with US; HCC diagnosis with CT, MRI, or contrast-enhanced US (CEUS); and treatment response assessment (TRA) with CT or MRI. LI-RADS was recently expanded to include CEUS TRA after nonradiation locoregional therapy or surgical resection. This report provides an overview of LI-RADS CEUS Nonradiation TRA v2024, including a lexicon of imaging findings, techniques, and imaging criteria for posttreatment tumor viability assessment. LI-RADS CEUS Nonradiation TRA v2024 takes into consideration differences in the CEUS appearance of viable tumor and posttreatment changes within and in close proximity to a treated lesion. Due to the high sensitivity of CEUS to vascular flow, posttreatment reactive changes commonly manifest as areas of abnormal perilesional enhancement without washout, especially in the first 3 months after treatment. To improve the accuracy of CEUS for nonradiation TRA, different diagnostic criteria are used to evaluate tumor viability within and outside of the treated lesion margin. Broader criteria for intralesional enhancement increase sensitivity for tumor viability detection. Stricter criteria for perilesional enhancement limit miscategorization of posttreatment reactive changes as viable tumor. Finally, the TRA algorithm reconciles intralesional and perilesional tumor viability assessment and assigns a single LI-RADS treatment response (LR-TR) category: LR-TR nonviable, LR-TR equivocal, or LR-TR viable.


Assuntos
Carcinoma Hepatocelular , Meios de Contraste , Neoplasias Hepáticas , Ultrassonografia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Ultrassonografia/métodos , Sistemas de Informação em Radiologia , Fígado/diagnóstico por imagem , Resultado do Tratamento
3.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548928

RESUMO

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos de Coortes , Meios de Contraste , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Europa (Continente) , América do Norte , Sensibilidade e Especificidade
4.
Ultrasound Q ; 40(1): 1-19, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37918119

RESUMO

ABSTRACT: Percutaneous core-needle biopsy (PCNB) plays a growing and essential role in many medical specialties. Proper and effective use of various PCNB devices requires basic understanding of how they function. Current literature lacks a detailed overview and illustration of needle function and design differences, a potentially valuable reference for users ranging from early trainees to experts who are less familiar with certain devices. This pictorial aims to provide such an overview, using diagrams and magnified photographs to illustrate the intricate components of these devices. Following a brief historical review of biopsy needle technology for context, we emphasize distinctions in design between 2 major classes of PCNB devices (side- and end-cutting devices), focusing on practical implications for how each device is most effectively used. We believe a nuanced understanding of biopsy device function sheds light on certain lingering ambiguities in biopsy practice, such as the optimal needle gauge in organ biopsy, the benefits and risks associated with coaxial technique, the impact of needle selection and technique on bleeding, and the risk of unsuccessful sampling. In a subsequent pictorial, we will draw on the concepts presented here to illustrate examples of biopsy needle failure and how unrecognized needle failure can be an important and often preventable cause of increased biopsy risk and lower tissue yield.


Assuntos
Biópsia Guiada por Imagem , Agulhas , Nitrobenzenos , Humanos , Biópsia com Agulha de Grande Calibre , Biópsia
5.
Laryngoscope ; 134(4): 1792-1801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37772838

RESUMO

OBJECTIVES: The paralaryngeal muscles are thought to be hyperfunctional with phonation in patients with primary muscle tension dysphonia (pMTD). However, objective, quantitative tools to assess paralaryngeal movement patterns lack. The objectives of this study were to (1) validate the use of optical flow to characterize paralaryngeal movement patterns with phonation, (2) characterize phonatory optical flow velocities and variability of the paralaryngeal muscles before and after a vocal load challenge, and (3) compare phonatory optical flow measures to standard laryngoscopic, acoustic, and self-perceptual assessments. METHODS: Phonatory movement velocities and variability of the paralaryngeal muscles at vocal onsets and offsets were quantified from ultrasound videos and optical flow methods across 42 subjects with and without a diagnosis of pMTD, before and after a vocal load challenge. Severity of laryngoscopic mediolateral supraglottic compression, acoustic perturbation, and ratings of vocal effort and discomfort were also obtained at both time points. RESULTS: There were no significant differences in optical flow measures of the paralaryngeal muscles with phonation between patients with pMTD and controls. Patients with pMTD had significantly more supraglottic compression, higher acoustic perturbations, and higher vocal effort and vocal tract discomfort ratings. Vocal load had a significant effect on vocal effort and discomfort but not on supraglottic compression, acoustics, or optical flow measures of the paralaryngeal muscles. CONCLUSION: Optical flow methods can be used to study paralaryngeal muscle movement velocity and variability patterns during vocal productions, although the role of the paralaryngeal in pMTD diagnostics (e.g., vocal hyperfunction) remains suspect. LEVEL OF EVIDENCE: 2 Laryngoscope, 134:1792-1801, 2024.


Assuntos
Disfonia , Fluxo Óptico , Humanos , Disfonia/diagnóstico , Fonação/fisiologia , Laringoscopia , Músculos
6.
Med Ultrason ; 2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38150695

RESUMO

Diagnosing rare hematological malignancies in the liver is often challenging owing to their infrequency, and confirmation generally necessitates histological examination. Due to the rarity of these lesions, there are limited data concerning their appearance on ultrasound and, specifically, contrast-enhanced ultrasound. In this review, we describe the pathological and ultrasound features of several hematological malignant liver lesions, including lymphoma of the liver and chloroma. Furthermore, two specific forms of liver lymphoma are described: mucosa-associated lymphoid tissue (MALT) lymphoma andplasmacytoma of the liver.

7.
Radiographics ; 43(8): e230032, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37498784

RESUMO

Pelvic organ prolapse (POP) and stress urinary incontinence (SUI) are two common disorders that affect the anterior compartment of the pelvic floor in women. These can be treated conservatively or surgically. Among patients treated surgically, a substantial number present with pain, recurrent POP or SUI, or other conditions that warrant additional interventions. In many of these cases, imaging is key to identifying and characterizing the type of procedure performed, locating synthetic materials that may have been placed, and characterizing complications. Imaging may be particularly helpful when prior surgical records are not available or a comprehensive physical examination is not possible. US and MRI are the most commonly used modalities for such patients, although radiopaque surgical materials may be visible at voiding cystourethrography and CT. The authors summarize commonly used surgical treatment options for patients with SUI and POP, review imaging techniques for evaluation of such patients, and describe the normal imaging appearance and complications of pelvic floor surgical repair procedures in the anterior compartment of the pelvis. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Prolapso de Órgão Pélvico , Procedimentos de Cirurgia Plástica , Incontinência Urinária por Estresse , Humanos , Feminino , Diafragma da Pelve/diagnóstico por imagem , Diafragma da Pelve/cirurgia , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/cirurgia , Incontinência Urinária por Estresse/diagnóstico por imagem , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/complicações , Imagem Multimodal
9.
Radiographics ; 43(1): e220066, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36427260

RESUMO

The use of standardized terms in assessing and reporting disease processes has well-established benefits, such as clear communication between radiologists and other health care providers, improved diagnostic accuracy and reproducibility, and the enhancement and facilitation of research. Recently, the Liver Imaging Reporting and Data System (LI-RADS) Steering Committee released a universal liver imaging lexicon. The current version of the lexicon includes 81 vetted and precisely defined terms that are relevant to acquisition of images using all major liver imaging modalities and contrast agents, as well as lesion- and organ-level features. Most terms in the lexicon are applicable to all patients undergoing imaging of the liver, and only a minority of the terms are strictly intended to be used for patients with high risk factors for hepatocellular carcinoma. This pictorial atlas familiarizes readers with the liver imaging lexicon and includes discussion of general concepts, providing sample definitions, schematics, and clinical examples for a subset of the terms in the liver imaging lexicon. The authors discuss general, technical, and imaging feature terms used commonly in liver imaging, with the goal of illustrating their use for clinical and research applications. Work of the U.S. Government published under an exclusive license with the RSNA. Online supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Reprodutibilidade dos Testes , Neoplasias Hepáticas/diagnóstico por imagem , Diagnóstico por Imagem
11.
Surg Oncol Clin N Am ; 31(4): 707-719, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36243503

RESUMO

Contrast-enhanced intraoperative ultrasound (CE-IOUS) is a relatively new but valuable tool that is increasingly used as an adjunct to computed tomography, MRI, and IOUS for patients undergoing liver surgery. CE-IOUS has an important role in 2 main settings: the discrimination of indeterminate lesions detected in cirrhotic livers by conventional IOUS and in the detection of colorectal liver metastasis that may be overlooked by other imaging modalities. The intraoperative nature of the imaging and interpretation allows for CE-IOUS to directly affect surgical decision-making that may importantly affect patient outcomes.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Meios de Contraste , Hepatectomia , Humanos , Cuidados Intraoperatórios/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia
12.
Radiol Clin North Am ; 60(5): 717-730, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35989040

RESUMO

Contrast-enhanced ultrasound (CEUS) is increasingly performed for focal liver lesion evaluation because of its high safety profile and ability to yield a definitive diagnosis in many patients, obviating multiphase CT or MRI. CEUS uses specific ultrasound contrast agents (UCAs) that are exceedingly safe, without the risk of renal or liver toxicity. UCAs are cleared rapidly from the body, allowing for multiple injections during a single examination, with no potential for deposition in the patient. This review highlights the performance of CEUS for liver lesion evaluation and illustrates the imaging appearance of common liver lesions in children and adults.


Assuntos
Neoplasias Hepáticas , Abdome/patologia , Adulto , Criança , Meios de Contraste , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Ultrassonografia/métodos
13.
Radiology ; 305(2): 277-289, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35787200

RESUMO

Gallbladder polyps (also known as polypoid lesions of the gallbladder) are a common incidental finding. The vast majority of gallbladder polyps smaller than 10 mm are not true neoplastic polyps but are benign cholesterol polyps with no inherent risk of malignancy. In addition, recent studies have shown that the overall risk of gallbladder cancer is not increased in patients with small gallbladder polyps, calling into question the rationale for frequent and prolonged follow-up of these common lesions. In 2021, a Society of Radiologists in Ultrasound, or SRU, consensus conference was convened to provide recommendations for the management of incidentally detected gallbladder polyps at US. See also the editorial by Sidhu and Rafailidis in this issue.


Assuntos
Doenças da Vesícula Biliar , Neoplasias da Vesícula Biliar , Neoplasias Gastrointestinais , Pólipos , Humanos , Doenças da Vesícula Biliar/diagnóstico por imagem , Pólipos/diagnóstico por imagem , Pólipos/patologia , Neoplasias da Vesícula Biliar/diagnóstico por imagem , Neoplasias da Vesícula Biliar/patologia , Radiologistas
16.
Eur Radiol ; 32(9): 6291-6301, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389052

RESUMO

Liver imaging plays a vital role in the management of patients at risk for hepatocellular carcinoma (HCC); however, progress in the field is challenged by nonuniform and inconsistent terminology in the published literature. The Steering Committee of the American College of Radiology (ACR)'s Liver Imaging Reporting And Data System (LI-RADS), in conjunction with the LI-RADS Lexicon Writing Group and the LI-RADS International Working Group, present this consensus document to establish a single universal liver imaging lexicon. The lexicon is intended for use in research, education, and clinical care of patients at risk for HCC (i.e., the LI-RADS population) and in the general population (i.e., even when LI-RADS algorithms are not applicable). We anticipate that the universal adoption of this lexicon will provide research, educational, and clinical benefits. KEY POINTS: •To standardize terminology, we encourage authors of research and educational materials on liver imaging to use the standardized LI-RADS Lexicon. •We encourage reviewers to promote the use of the standardized LI-RADS Lexicon for publications on liver imaging. •We encourage radiologists to use the standardized LI-RADS Lexicon for liver imaging in clinical care.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
17.
AJR Am J Roentgenol ; 219(3): 445-452, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35383486

RESUMO

BACKGROUND. The American College of Radiology Ultrasound LI-RADS includes the visualization score as a subjective measure of examination quality and the expected level of sensitivity. Whether a single suboptimal visualization score warrants a change in surveillance strategy is unknown. OBJECTIVE. The purpose of this study is to determine the relative stability of visualization scores on serial surveillance ultrasound examinations in patients at risk for HCC. METHODS. This retrospective study included patients at risk for HCC who underwent at least two HCC surveillance ultrasound examinations at one of three institutions between January 2017 and November 2020. The frequencies of the score remaining unchanged after variable numbers of preceding examinations with the given score were determined. A mixed-effects logistic model was fitted to identify factors associated with a repeat score of C (denoting severe limitations) versus a change to score A (indicating no or minimal limitations) or score B (denoting moderate limitations). RESULTS. A total of 3169 patients underwent at least two ultrasound examinations, yielding a total of 9602 examinations. A total of 8030 examinations (83.6%) were assigned score A; 1378 (14.4%), score B; and 194 (2.0%), score C. The frequency of score A was 88%, 91%, and 93% after one, two, and three consecutive prior examinations with score A, respectively. The frequency of score B was 45%, 48%, and 55% after one, two, and three consecutive prior examinations with score B. The frequency of score C was 42%, 67%, and 80% after one, two, and three consecutive prior examinations with score C. Among 109 examinations with score C in 91 patients with an available follow-up examination, no factor (including age, sex, severe steatosis, advanced cirrhosis, ascites, body mass index, and a change in the ultrasound machine, sonographer, or radiologist) was significantly associated with repeat score C (all p > .05). Although not statistically significant, presence of severe steatosis and presence of advanced cirrhosis had the highest odds ratios (2.88 and 2.38, respectively) for repeat score C in multivariable analysis. CONCLUSION. Only 42% of patients with visualization score C on a single surveillance examinations have score C on follow-up examinations; however, after two or more score C examinations, the chance of future score C substantially increases. CLINICAL IMPACT. The findings may inform decisions regarding alternative surveillance strategies in patients with visualization score C on ultrasound. This decision should consider the number of previous examinations with score C.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Humanos , Cirrose Hepática , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia/métodos
18.
Ultrasound Q ; 38(2): 133-141, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35362690

RESUMO

ABSTRACT: Hemangioma is the most common benign liver tumor and is frequently encountered as an incidental finding on imaging. The classic enhancement pattern of hemangioma is diagnostic on contrast-enhanced ultrasound (CEUS), and it follows the same pattern of enhancement on computed tomography and magnetic resonance imaging. However, there is a subset of hemangiomas that demonstrate atypical enhancement patterns on CEUS. The ability to recognize the different enhancement patterns and discern when additional imaging or biopsy may be necessary is essential to accurately interpret an atypical hemangioma on CEUS. This article reviews various enhancement patterns of hemangioma on CEUS to avoid pitfalls in characterization of focal liver lesions on CEUS.


Assuntos
Hemangioma , Neoplasias Hepáticas , Meios de Contraste , Hemangioma/diagnóstico por imagem , Hemangioma/patologia , Humanos , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Ultrassonografia/métodos
19.
Ultrasound Q ; 38(2): 96-102, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35221317

RESUMO

ABSTRACT: Gallbladder polyps (GPs) are a common incidental finding on ultrasound; however, important differences in recommended management exist among professional society guidelines.An electronic survey was sent to 189 fellows of the Society of Radiologists in Ultrasound. Main outcomes included preferences and current practice patterns for evaluation, management, and surveillance of GPs as well as personal lifetime experience with gallbladder sonography and GPs.A total of 64 subjects (34%) with experience in gallbladder sonography completed the study. The estimated combined total number of gallbladder scans seen by the responders was 3,071,880. None of fellows had ever seen a pedunculated GP <1 cm detected on ultrasound that was proven to be malignant at the time of detection or during subsequent follow-up. All of the fellows used size as a feature to stratify recommendations. The median size threshold currently used by Society of Radiologists in Ultrasound fellows for recommending ultrasound follow-up was 6 mm, and their preferred threshold was 7 mm. The median size threshold for recommending surgical consultation was 10 mm, and the preferred threshold was 10 mm. Wall thickening and shape were considered important factors by 76% and 67% of respondents, respectively.Society of Radiologists in Ultrasound fellows tend to provide recommendations most similar to the American College of Radiology and Canadian Association of Radiology guidelines for management of GPs. Many would prefer guidelines that result in fewer recommendations for follow-up and surgical consultation. Despite a substantial combined experience, this survey did not uncover any case of a small GP that was malignant.


Assuntos
Vesícula Biliar , Pólipos , Canadá , Vesícula Biliar/diagnóstico por imagem , Humanos , Achados Incidentais , Radiologistas , Inquéritos e Questionários
20.
Aliment Pharmacol Ther ; 55(6): 683-690, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35170052

RESUMO

BACKGROUND: Ultrasound visualisation is limited in approximately 20% of patients with cirrhosis undergoing hepatocellular carcinoma (HCC) surveillance; however, it is unknown if impaired visualisation directly impacts test performance. We aimed to evaluate the association between ultrasound visualisation and surveillance test performance. METHODS: We performed a retrospective cohort study among patients with cirrhosis, with or without HCC, who underwent ultrasound-based surveillance at two large health systems between July 2016 and July 2019. Ultrasound visualisation assessment was recorded by interpreting radiologists using the ultrasound LI-RADS Visualisation score. We performed logistic regression analyses to evaluate the association between ultrasound visualisation and diagnostic test performance. We assessed sensitivity for HCC detection among ultrasounds performed in the year prior to HCC diagnoses and specificity using ultrasounds in those without HCC. RESULTS: Among 186 patients with HCC, severely limited visualisation (Vis Score C) on ultrasound prior to HCC diagnosis was associated with increased odds of false-negative results, that is lower sensitivity (OR 7.94, 95% CI 1.23-51.16) in multivariable analysis. Ultrasound sensitivity with visualisation scores A or B exceeded 75%, compared to only 27.3% with visualisation score C. Among 2052 cirrhosis patients without HCC, moderate visualisation limitations (Vis score B) were associated with increased odds of false-positive results (OR 1.60, 1.13-2.27), although specificity exceeded 95% across all visualisation scores. CONCLUSIONS: Impaired ultrasound visualisation is associated with worse surveillance test performance. Alternative blood-based biomarkers and imaging strategies are needed for patients at risk for ultrasound-based surveillance failure.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/etiologia , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/etiologia , Estudos Retrospectivos , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA