Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 29(3): 1219-1230, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33389643

RESUMO

BACKGROUND: We hypothesized early post-stress left ventricular ejection fraction reserve (EFR) on solid-state-SPECT is associated with major cardiac adverse events (MACE). METHODS: 151 patients (70 ± 12 years, male 50%) undergoing same-day rest/regadenoson stress 99mTc-sestamibi solid-state SPECT were followed for MACE. Rest imaging was performed in the upright and supine positions. Early stress imaging was started 2 minutes after the regadenoson injection in the supine position and followed by late stress acquisition in the upright position. Total perfusion deficit (TPD) and functional parameters were quantified automatically. EFR, ∆end-diastolic volume (EDV), and end-systolic volume (ESV) were calculated as the difference between stress and rest values in the same position. EFR < 0%, ∆EDV ≥ 5 ml, or ∆ESV ≥ 5 ml was defined as abnormal. RESULTS: During the follow-up (mean 3.2 years), 28 MACE occurred (19%). In Kaplan-Meier analysis, there was a significantly decreased event-free survival in patients with early EFR < 0% (P = 0.004). Similarly, there was a decreased event-free survival in patients with ∆ESV ≥ 5 ml at early stress (P = 0.003). However, EFR, ∆EDV, and ∆ESV at late stress were not associated with MACE-free survival. Cox proportional hazards model adjusting for clinical information and stress TPD demonstrated that EFR, ∆EDV, and ∆ESV at early stress were significantly associated with MACE (P < 0.05 for all). CONCLUSIONS: Reduced early post-stress EFR on vasodilator stress solid-state SPECT is associated with MACE.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Prognóstico , Purinas , Pirazóis , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem
2.
J Nucl Cardiol ; 27(4): 1180-1189, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31087268

RESUMO

BACKGROUND: Upper reference limits for transient ischemic dilation (TID) have not been rigorously established for cadmium-zinc-telluride (CZT) camera systems. We aimed to derive TID limits for common myocardial perfusion imaging protocols utilizing a large, multicenter registry (REFINE SPECT). METHODS: One thousand six hundred and seventy-two patients with low likelihood of coronary artery disease with normal perfusion findings were identified. Images were processed with Quantitative Perfusion SPECT software (Cedars-Sinai Medical Center, Los Angeles, CA). Non-attenuation-corrected, camera-, radiotracer-, and stress protocol-specific TID limits in supine position were derived from 97.5th percentile and mean + 2 standard deviations (SD). Reference limits were compared for different solid-state cameras (D-SPECT vs. Discovery), radiotracers (technetium-99m-sestamibi vs. tetrofosmin), different types of stress (exercise vs. four different vasodilator-based protocols), and different vasodilator-based protocols. RESULTS: TID measurements did not follow Gaussian distribution in six out of eight subgroups. TID limits ranged from 1.18 to 1.52 (97.5th percentile) and 1.18 to 1.39 (mean + 2SD). No difference was noted between D-SPECT and Discovery cameras (P = 0.71) while differences between exercise and vasodilator-based protocols (adenosine, regadenoson, or regadenoson-walk) were noted (all P < 0.05). CONCLUSIONS: We used a multicenter registry to establish camera-, radiotracer-, and protocol-specific upper reference limits of TID for supine position on CZT camera systems. Reference limits did not differ between D-SPECT and Discovery camera.


Assuntos
Câmaras gama , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Cádmio , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Telúrio , Zinco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA