1.
Med Phys ; 33(3): 719-36, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16878575

RESUMO

The Digital Mammography Imaging Screening Trial, conducted by the American College of Radiology Imaging Network, is a clinical trial designed to compare the accuracy of full-field digital mammography (FFDM) versus screen-film mammography in a screening population. Five FFDM systems from four manufacturers (Fischer, Fuji, General Electric, and Lorad) were employed in the study at 35 clinical sites. A core physics team devised and implemented tests to evaluate these systems. A detailed description of physics and quality control tests is presented, including estimates of: mean glandular dose, modulation transfer function (MTF), 2D noise power spectra, and signal-to-noise ratio (SNR). The mean glandular doses for the standard breast ranged from 0.79 to 2.98 mGy, with 1.62 mGy being the average across all units and machine types. For the five systems evaluated, the MTF dropped to 50% at markedly different percentages (22% to 87%) of the Nyquist limit, indicating that factors other than detector element (del) size have an important effect on spatial resolution. Noise power spectra and SNR were measured; however, we found that it was difficult to standardize and compare these between units. For each machine type, the performance as measured by the tests was very consistent, and no predictive benefit was seen for many of the tests during the 2-year period of the trial. It was found that, after verification of proper operation during acceptance testing, if systems failed they generally did so suddenly rather than through gradual deterioration of performance. Because of the relatively short duration of this study further, investigation of the long-term failure characteristics of these systems is advisable.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Algoritmos , Artefatos , Neoplasias da Mama/diagnóstico , Ensaios Clínicos como Assunto , Humanos , Mamografia/instrumentação , Mamografia/normas , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Ecrans Intensificadores para Raios X
2.
Med Phys ; 33(3): 737-52, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16878576

RESUMO

The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Neoplasias da Mama/diagnóstico , Ensaios Clínicos como Assunto , Testes Diagnósticos de Rotina/instrumentação , Testes Diagnósticos de Rotina/métodos , Diretrizes para o Planejamento em Saúde , Humanos , Mamografia/instrumentação , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ecrans Intensificadores para Raios X