Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 25(1): 10, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36793062

RESUMO

BACKGROUND: The use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images. METHODS: LA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking. RESULTS: Compared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias - 13 ml; LOA = + 11, - 37 ml; LAVmax i: bias - 7 ml/m2; LOA = + 7, - 21 ml/m2; LAVmin; bias - 10 ml, LOA: + 9, - 28 ml; LAVmin i: bias - 5 ml/m2, LOA: + 5, - 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, - 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, - 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, - 6 ml/m2; LAVmin: bias - 2 ml; LOA: + 7, - 10 ml; LAVmin i: bias - 1 ml/m2; LOA: + 3, - 5 ml/m2) and LAEF (bias 2%, LOA: + 11, - 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, - 11%; εe: bias 4%, LOA = 15, - 8%; εa: bias 3%, LOA = 14, - 8%) was significantly higher in standard vs. LA-focused images (p < 0.001). CONCLUSION: LA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.


Assuntos
Ecocardiografia , Átrios do Coração , Humanos , Valor Preditivo dos Testes , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA