Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Cardiol Young ; 34(2): 387-394, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37462049

RESUMO

BACKGROUND: Patients with unbalanced common atrioventricular canal can be difficult to manage. Surgical planning often depends on pre-operative echocardiographic measurements. We aimed to determine the added utility of cardiac MRI in predicting successful biventricular repair in common atrioventricular canal. METHODS: We conducted a retrospective cohort study of children with common atrioventricular canal who underwent MRI prior to repair. Associations between MRI and echocardiographic measures and surgical outcome were tested using logistic regression, and models were compared using area under the receiver operator characteristic curve. RESULTS: We included 28 patients (median age at MRI: 5.2 months). The optimal MRI model included the novel end-diastolic volume index (using the ratio of left ventricular end-diastolic volume to total end-diastolic volume) and the left ventricle-right ventricle angle in diastole (area under the curve 0.83, p = 0.041). End-diastolic volume index ≤ 0.18 and left ventricle-right ventricle angle in diastole ≤ 72° yield a sensitivity of 83% and specificity of 81% for successful biventricular repair. The optimal multimodality model included the end-diastolic volume index and the echocardiographic atrioventricular valve index with an area under the curve of 0.87 (p = 0.026). CONCLUSIONS: Cardiac MRI can successfully predict successful biventricular repair in patients with unbalanced common atrioventricular canal utilising the end-diastolic volume index alone or in combination with the MRI left ventricle-right ventricle angle in diastole or the echocardiographic atrioventricular valve index. A prospective cardiac MRI study is warranted to better define the multimodality characteristic predictive of successful biventricular surgery.


Assuntos
Defeitos dos Septos Cardíacos , Criança , Humanos , Lactente , Estudos Retrospectivos , Defeitos dos Septos Cardíacos/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
2.
Ann Thorac Surg ; 115(6): 1486-1492, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35988737

RESUMO

BACKGROUND: Single ventricle (SV) patients undergo multiple surgeries with subsequent changes in anatomy and hemodynamics. There are little cardiac magnetic resonance (CMR) data on serial changes in these patients. This study aimed to assess longitudinal changes of SV anatomy and hemodynamics in a large cohort. METHODS: Anatomy and flow in SV patients with serial CMRs performed between 2008 and 2019 at a single institution were retrospectively reviewed. Mixed-effects linear regression was used to estimate changes over time at 3 to 9 months, 1 to 5 years, and >5 years after Fontan. RESULTS: A total of 119 patients were included (51% with hypoplastic left heart syndrome; 77% underwent extracardiac Fontan). A total of 88 patients had 3 serial CMRs. Indexed right superior vena cava, inferior vena cava, neoaortic valve, and descending aorta area decreased over time (beta = -0.19, -0.44, and -0.23, respectively; P < .01), as did indexed right superior vena cava, neoaorta and native aorta, and descending aorta flow (beta = -0.49, -0.53, and -0.59, respectively; P < .0001). Inferior vena cava flow and its contribution to total caval flow increased (beta = 0.33; P < .0001). Indexed right and left pulmonary artery flow did not change; however, indexed left pulmonary artery area decreased (beta = -0.16; P = .0014) with time. Systemic-to-pulmonary collateral flow remained unchanged before and early after Fontan (beta = -0.54; P = .42) but decreased with time from Fontan (beta = -0.22; P < .0001). CONCLUSIONS: In this cohort of longitudinally followed SV patients, there are significant trends in vascular size and flow over time from Fontan. These findings can be used as a framework to interpret serial CMR data in the SV and noninvasively identify deviations from expected patterns before the development of clinical symptoms.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Coração Univentricular , Humanos , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Estudos Retrospectivos , Hemodinâmica , Artéria Pulmonar/cirurgia , Cardiopatias Congênitas/cirurgia
3.
Ann Thorac Surg ; 114(3): 841-847, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35120878

RESUMO

BACKGROUND: Despite favorable short-term outcomes, Fontan palliation is associated with comorbidities and diminished quality of life (QOL) in the years after completion. We hypothesized that poor Fontan hemodynamics and ventricular function are associated with worse QOL. METHODS: This was a single-center study of Fontan survivors aged more than 12 years. Subjects completed a cardiac magnetic resonance scan and QOL questionnaire. Cardiac magnetic resonance-derived variables included Fontan geometry, and hemodynamics. Computational fluid dynamics simulations quantified power loss, pressure drop, and total cavopulmonary connection resistance across the Fontan. Quality of life was assessed by completion of the Pediatric Quality of Life Inventory. Longitudinal and cross-sectional comparisons were made between cardiac magnetic resonance and computational fluid dynamics parameters with patient-reported QOL. RESULTS: We studied 77 Fontan patients, median age 19.7 years (interquartile range, 17.1 to 23.6), median time from Fontan completion 16 years (interquartile range, 13 to 20). Longitudinal data were available for 48 patients; median time between cardiac magnetic resonance and QOL was 8.1 years (interquartile range, 7 to 9.4). Median patient-reported Pediatric Quality of Life Inventory total score was 80 (interquartile range, 67.4 to 88). Greater power loss and smaller left pulmonary artery diameter at baseline were associated with worse QOL at follow-up. Greater pressure drop was associated with worse QOL at the same time point. CONCLUSIONS: For Fontan survivors, measures of computational fluid dynamics hemodynamics and geometry are associated with worse QOL. Interventional strategies targeted at optimizing the Fontan may improve QOL.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adolescente , Adulto , Criança , Estudos Transversais , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Artéria Pulmonar/cirurgia , Qualidade de Vida , Adulto Jovem
4.
J Thorac Cardiovasc Surg ; 163(3): 1205-1207, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34429193
6.
Cardiovasc Eng Technol ; 12(6): 618-630, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34114202

RESUMO

BACKGROUND: Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE: This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.


Assuntos
Sistema Cardiovascular , Técnica de Fontan , Cardiopatias Congênitas , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Modelos Cardiovasculares
7.
Semin Thorac Cardiovasc Surg ; 33(3): 816-823, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33662555

RESUMO

This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Pulmão , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia
8.
J Thorac Cardiovasc Surg ; 162(6): 1813-1822.e3, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33785214

RESUMO

OBJECTIVE: We sought to evaluate contractile function in single-ventricle patients before and after imposition of Fontan physiology. METHODS: Single right ventricle (SRV; n = 38) and single left ventricle (SLV; n = 11) patients underwent cardiac magnetic resonance imaging pre and post Fontan operation. Global radial strain (GRS), global circumferential strain (GCS), and global longitudinal strain were measured along with ejection fraction (EF) and atrioventricular valve regurgitation (AVVR). RESULTS: Age at cardiac magnetic resonance imaging before the Fontan operation was 3.1 ± 1.3 years and after the Fontan procedure was 5.8 ± 2.7 years. There were no significant EF differences between SRV and SLV patients before and after the Fontan procedure, and EF did not deteriorate significantly after the Fontan operation. GRS was significantly lower for SRV patients than for SLV patients before (24.3% vs 32.1%; P = .048) and after (21.8% vs 29.7%; P = .045) the Fontan procedure. GRS and GCS of the SRV patients deteriorated significantly after the Fontan operation (GRS, P = .01; GCS, P = .009). Strains showed positive correlations before and after the Fontan operation with positive correlations among each strain. Within all patients, strains correlated positively with EF. Strains and EF negatively correlated with AVVR (GRS P = .03, r = -0.22; GCS P = .03, r = -0.23; EF P < .001, r = -0.37). CONCLUSIONS: Strains were lower for SRV than for SLV patients before and after the Fontan operation and deteriorated after the Fontan operation. Our study suggests that strain measures might detect ventricular deterioration earlier than EF. Because strains before and after the Fontan operation were positively correlated, and negatively correlated with AVVR, the early institution of myocardial protective therapy including AVVR management, especially for SRV patients, might have benefit.


Assuntos
Técnica de Fontan , Coração Univentricular/fisiopatologia , Coração Univentricular/cirurgia , Função Ventricular , Fenômenos Biomecânicos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Volume Sistólico
9.
Semin Ultrasound CT MR ; 41(5): 442-450, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32980091

RESUMO

The Fontan operation or the total cavopulmonary connection is a palliative surgery for single ventricle congenital heart disease where the systemic venous return circumvents a pumping chamber and flows directly into the pulmonary circuit. With surgical and medical advances, there has been improvement in life expectancy of these patients, however, it has also resulted in unique complications from the physiology that requires diligent surveillance. A critical component relies on optimal imaging for diagnosis and treatment of these complications. This article describes the normal anatomy of the Fontan circulation, current imaging modalities and techniques, and frequently encountered complications seen when imaging the patients who have undergone Fontan palliation.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Criança , Diagnóstico por Imagem/métodos , Feminino , Coração/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Cuidados Paliativos/métodos , Resultado do Tratamento , Adulto Jovem
10.
Ann Biomed Eng ; 48(8): 2204-2217, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32372365

RESUMO

The Fontan procedure is a common palliative surgery for congenital single ventricle patients. In silico and in vitro patient-specific modeling approaches are widely utilized to investigate potential improvements of Fontan hemodynamics that are related to long-term complications. However, there is a lack of consensus regarding the use of non-Newtonian rheology, warranting a systematic investigation. This study conducted in silico patient-specific modeling for twelve Fontan patients, using a Newtonian and a non-Newtonian model for each patient. Differences were quantified by examining clinically relevant metrics: indexed power loss (iPL), indexed viscous dissipation rate (iVDR), hepatic flow distribution (HFD), and regions of low wall shear stress (AWSS). Four sets of "non-Newtonian importance factors" were calculated to explore their effectiveness in identifying the non-Newtonian effect. No statistical differences were observed in iPL, iVDR, and HFD between the two models at the population-level, but large inter-patient variations exist. Significant differences were detected regarding AWSS, and its correlations with non-Newtonian importance factors were discussed. Additionally, simulations using the non-Newtonian model were computationally faster than those using the Newtonian model. These findings distinguish good importance factors for identifying non-Newtonian rheology and encourage the use of a non-Newtonian model to assess Fontan hemodynamics.


Assuntos
Técnica de Fontan , Hidrodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos
11.
Pediatr Cardiol ; 41(5): 1021-1030, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32377893

RESUMO

Apicocaval juxtaposition (ACJ) is a rare form of viscerocardiac malpositions in association with single-ventricle congenital heart defects. The Fontan surgery is the common palliation, and possible surgical options include ipsilateral, contralateral, and intra-atrial conduits. Concerns include lower hemodynamic performances or risks of conduit compression by the cardiac mass. This study investigates the hemodynamics and clinical outcomes of ACJ patients and potential surgical improvements. Ten consecutive ACJ patients were included, along with a reference cohort of ten non-ACJ patients. Magnetic resonance images were acquired at 6 ± 0.6 year follow-up for anatomical analysis and hemodynamic assessments using computational fluid dynamics. Metrics of interest are deformation index (DI), indexed power loss (iPL), and hepatic flow distribution (HFDoff). A "virtual" surgery was performed to explore potential hemodynamic improvements using a straightened conduit. DI for ACJ patients fell within the DI range of non-ACJ patients. Contralateral conduits had insignificantly higher iPL (0.070 [0.032,0.137]) than ipsilateral conduits (0.041 [0.013,0.095]) and non-ACJ conduits (0.034 [0.011,0.061]). HFDoff was similar for the ipsilateral (21 [12,35]), contralateral (26 [7,41]), and non-ACJ Fontan conduits (17 [0,48]). Virtual surgery demonstrated that a straightened conduit reduced HFDoff and iPL for the contralateral and ipsilateral conduits, potentially leading to improved clinical outcomes. In this limited sample, the hemodynamic performance of ACJ patients was not significantly different from their non-ACJ counterparts. The use of a straightened conduit option could potentially improve patient outcomes. Additionally, the fear of significant compression of conduits for ACJ patients was unsupported.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Artéria Pulmonar/patologia , Artéria Pulmonar/cirurgia
12.
Ann Thorac Surg ; 109(2): 574-582, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31518584

RESUMO

BACKGROUND: Little is known of baseline anatomic, hemodynamic, and fluid dynamic cardiac magnetic resonance data in single-ventricle patients immediately after Fontan. A comparison from that time point to the teen years can demonstrate clinical course, potentially predict future events, and may shed some light regarding how to optimize outcome. This cross-sectional study is meant to characterize these variables from just after Fontan to the teenage years. METHODS: The anatomy, flows, and computational fluid dynamic modeling of 22 patients 3 to 9 months after Fontan (age 3 ± 1.1 years) and 25 teens (age 16 ± 1.8 years) were compared. Significance was defined as P less than .05. RESULTS: The percentage of Fontan pathway stenosis was greater with cardiac index and fenestration flow while caval return was lower in teens than in younger patients (for Fontan pathway stenosis, 43% vs 21%, P = .009); however, hepatic flow distribution was more evenly distributed in older patients. Pulmonary artery size kept up with somatic growth. In the teen group, indexed power loss (R = .39), percentage of Fontan pathway stenosis (R = .62), and particle resident time (R = .42) deteriorated as time from Fontan increased (P < .04 for all). CONCLUSIONS: There are mostly aspects of deterioration with a few bright spots of stability in anatomy, blood flow, and fluid dynamic variables in Fontan patients from the postoperative period to the teenage years. Most notably, Fontan pathway stenosis increases with decreasing flows while pulmonary artery size and hepatic flow distribution remain stable or improved. These data may be aid in designing improved Fontan reconstruction to optimize clinical outcome and to understand future complications.


Assuntos
Técnica de Fontan , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Coração Univentricular/cirurgia , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Período Pós-Operatório , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
J Thorac Cardiovasc Surg ; 159(2): 652-661, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31399233

RESUMO

OBJECTIVE: The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. METHODS: Ten Fontan patients with commercially available Y-graft connections and serial postoperative cardiac magnetic resonance data were included in this study. Patient-specific computational fluid dynamics simulations were used to estimate HFD and energy losses. Y-graft performance was compared with 3 extracardiac conduit Fontan groups (n = 10 for each) whose follow-up times straddle the Y-graft time points. RESULTS: Y-graft HFD became significantly more balanced over time (deviation from 50% decreased from 18% ± 14% to 8% ± 8%; P = .015). Total cavopulmonary connection resistance did not significantly change. Y-grafts at 3-year follow-up showed more balanced HFD than the extracardiac conduit groups at both the earlier and later follow-up times. Total cavopulmonary connection resistance was not significantly different between any Y-graft or extracardiac conduit group. CONCLUSIONS: Y-grafts showed significantly more balanced HFD over a 3-year follow-up without an increase in total cavopulmonary connection resistance, and therefore may be a valuable option for Fontan completion. Additional follow-up data at longer follow-up times are still needed to thoroughly characterize the potential advantages of Y-graft use.


Assuntos
Prótese Vascular , Técnica de Fontan , Hemodinâmica/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Técnica de Fontan/efeitos adversos , Técnica de Fontan/instrumentação , Técnica de Fontan/métodos , Técnica de Fontan/estatística & dados numéricos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Desenho de Prótese , Artéria Pulmonar/fisiologia , Artéria Pulmonar/cirurgia , Adulto Jovem
14.
Ann Thorac Surg ; 109(6): 1904-1911, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31734244

RESUMO

BACKGROUND: Liver fibrosis is a serious complication of single ventricle Fontan survivors. Its causes are of great interest, and potential solutions to halt or delay progression are needed. The purpose of this study is to investigate if prior hemodynamics and anatomy can predict liver fibrosis severity in these patients. METHODS: Twenty-one Fontan patients with cardiac magnetic resonance (CMR) data obtained greater than 1 year before liver biopsy data were included. Computational fluid dynamic simulations were performed to quantify total cavopulmonary connection (TCPC) flow dynamics using patient-specific anatomies and blood flow waveforms reconstructed from CMR data. Collagen deposition (a measure of liver fibrosis) was quantified by digital image analysis of Sirius red-stained slides. Statistical analyses were performed to investigate potential relationships between Fontan hemodynamics and liver fibrosis. RESULTS: With an average time of 6.7 ± 2.9 years (range, 2-11 years) between CMR and biopsy, TCPC resistance and left pulmonary artery stenosis showed significant, positive correlations with magnitude of liver fibrosis (r = 0.54, P = .026; and r = 0.55, P = .028, respectively). The change in inferior vena cava flow rate over time also showed a significant positive correlation with magnitude of liver fibrosis (r = 0.91, P = .001). CONCLUSIONS: TCPC resistance, left pulmonary artery stenosis, and increased inferior vena cava flow are positively associated with liver fibrosis after Fontan operation and hold promise as important predictors of hepatic decline. These findings encourage preprocedural planning and interventional strategies to improve TCPC performance and reduce vessel stenosis. Further investigation is warranted to design the ideal Fontan circulation and optimize flow dynamics to reduce the risk of liver fibrosis.


Assuntos
Técnica de Fontan/efeitos adversos , Previsões , Cardiopatias Congênitas/diagnóstico , Cirrose Hepática/diagnóstico , Fígado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias , Adolescente , Biópsia , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Cirrose Hepática/etiologia , Masculino , Período Pré-Operatório , Adulto Jovem
15.
J Cardiovasc Transl Res ; 13(4): 640-647, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31732919

RESUMO

Fontan surgical planning ranks proposed surgical options according to their hemodynamics assessed by computational fluid dynamic (CFD) modeling. CFD commonly utilizes blood flow acquired under breath-holding (BH) conditions. Ignoring the free-breathing (FB) effect on blood flow waveforms may impact the ranking of surgical options. This study investigates such a potential impact by including ten Fontan patients who had blood flow acquisitions under both BH and FB conditions. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. These options were ranked based on clinically relevant hemodynamic metrics: power loss (PL) and hepatic flow distribution (HFD). No difference was found in the ranking of options between using FB and BH flow acquisitions. The findings indicated that decision-making is not affected by the types of flow acquisition for Fontan surgical planning.


Assuntos
Tomada de Decisão Clínica , Diagnóstico por Computador , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Adolescente , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Reoperação , Mecânica Respiratória , Estudos Retrospectivos , Adulto Jovem
16.
Radiology ; 293(3): 554-564, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31638489

RESUMO

Background Ferumoxytol is approved for use in the treatment of iron deficiency anemia, but it can serve as an alternative to gadolinium-based contrast agents. On the basis of postmarketing surveillance data, the Food and Drug Administration issued a black box warning regarding the risks of rare but serious acute hypersensitivity reactions during fast high-dose injection (510 mg iron in 17 seconds) for therapeutic use. Whereas single-center safety data for diagnostic use have been positive, multicenter data are lacking. Purpose To report multicenter safety data for off-label diagnostic ferumoxytol use. Materials and Methods The multicenter ferumoxytol MRI registry was established as an open-label nonrandomized surveillance databank without industry involvement. Each center monitored all ferumoxytol administrations, classified adverse events (AEs) using the National Cancer Institute Common Terminology Criteria for Adverse Events (grade 1-5), and assessed the relationship of AEs to ferumoxytol administration. AEs related to or possibly related to ferumoxytol injection were considered adverse reactions. The core laboratory adjudicated the AEs and classified them with the American College of Radiology (ACR) classification. Analysis of variance was used to compare vital signs. Results Between January 2003 and October 2018, 3215 patients (median age, 58 years; range, 1 day to 96 years; 1897 male patients) received 4240 ferumoxytol injections for MRI. Ferumoxytol dose ranged from 1 to 11 mg per kilogram of body weight (≤510 mg iron; rate ≤45 mg iron/sec). There were no systematic changes in vital signs after ferumoxytol administration (P > .05). No severe, life-threatening, or fatal AEs occurred. Eighty-three (1.9%) of 4240 AEs were related or possibly related to ferumoxytol infusions (75 mild [1.8%], eight moderate [0.2%]). Thirty-one AEs were classified as allergiclike reactions using ACR criteria but were consistent with minor infusion reactions observed with parenteral iron. Conclusion Diagnostic ferumoxytol use was well tolerated, associated with no serious adverse events, and implicated in few adverse reactions. Registry results indicate a positive safety profile for ferumoxytol use in MRI. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Meios de Contraste/efeitos adversos , Óxido Ferroso-Férrico/efeitos adversos , Imageamento por Ressonância Magnética , Uso Off-Label , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Sistema de Registros
17.
J Thorac Cardiovasc Surg ; 157(3): 1146-1155, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31264966

RESUMO

OBJECTIVE: Fontan surgical planning is an image-based, collaborative effort, which is hypothesized to result in improved patient outcomes. A common motivation for Fontan surgical planning is the progression (or concern for progression) of pulmonary arteriovenous malformations. The purpose of this study was to evaluate the accuracy of surgical planning predictions, specifically hepatic flow distribution (HFD), a known factor in pulmonary arteriovenous malformation progression, and identify methodological improvements needed to increase prediction accuracy. METHODS: Twelve single-ventricle patients who were enrolled in a surgical planning protocol for Fontan surgery with pre- and postoperative cardiac imaging were included in this study. Computational fluid dynamics were used to compare HFD in the surgical planning prediction and actual postoperative conditions. RESULTS: Overall, HFD prediction error was 17 ± 13%. This error was similar between surgery types (15 ± 18% and 18 ± 10% for revisions vs Fontan completions respectively; P = .73), but was significantly lower (6 ± 7%; P = .05) for hepatic to azygous shunts. Y-grafts and extracardiac conduits showed a strong correlation between prediction error and discrepancies in graft insertion points (r = 0.99; P < .001). Improving postoperative anatomy prediction significantly reduced overall HFD prediction error to 9 ± 6% (P = .03). CONCLUSIONS: Although Fontan surgical planning can offer accurate HFD predictions for specific graft types, methodological improvements are needed to increase overall accuracy. Specifically, improving postoperative anatomy prediction was shown to be an important target for future work. Future efforts and refinements to the surgical planning process will benefit from an improved understanding of the current state and will rely heavily on increased follow-up data.


Assuntos
Tomada de Decisão Clínica , Técnicas de Apoio para a Decisão , Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Circulação Hepática , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Técnica de Fontan/efeitos adversos , Georgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Humanos , Hidrodinâmica , Lactente , Masculino , Modelos Cardiovasculares , Seleção de Pacientes , Philadelphia , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Ann Thorac Surg ; 108(2): 574-580, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30959013

RESUMO

BACKGROUND: Patients with single ventricle (SV) may often undergo aortic reconstruction that creates a stiff large vessel, increasing afterload and affecting exercise performance. The objective of this study was to determine the relationship of pulse wave velocity (PWV) and distensibility in reconstructed and normal aortic arches after Fontan with exercise variables. METHODS: PWV and distensibility of the descending aorta at the level of the diaphragm (DAo) were calculated with real-time exercise cardiac magnetic resonance in 48 patients with SV after Fontan (18 after aortic reconstruction; 30 without aortic reconstruction) and compared with metabolic exercise stress test variables. RESULTS: PWV was greater in the reconstructed group than in the non-reconstructed group (median 4.4 m/s [range: 2.3 to 9.8 m/s] versus 3.6 [range: 2.6 to 6.3 m/s], respectively, p = 0.003). Statistically significant inverse correlations were found between PWV and end-diastolic, end-systolic, and stroke volumes at rest and at exercise in the reconstructed group. In addition, inverse correlations also existed in the reconstructed group between distensibility of the DAo and the exercise variables such as peak oxygen pulse (R = 0.56, p = 0.02), peak oxygen consumption (R = 0.63, p = 0.008), oxygen consumption at ventilatory anaerobic threshold (R = 0.48, p = 0.04), and peak work (R = 0.54, p = 0.02). Similar correlations were not seen in patients with non-reconstructed aortas. CONCLUSIONS: Patients with SV with reconstructed aortas have increased aortic stiffness, increasing afterload on the ventricle. Native DAo stiffness distal to the reconstruction is inversely correlated with exercise performance, presumably to decrease impedance mismatch to maintain homogeneity of the aortic wall. This information suggests a possible mechanism for decreased exercise performance in patients with SV with aortic reconstructions.


Assuntos
Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Volume Cardíaco/fisiologia , Exercício Físico/fisiologia , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/fisiopatologia , Rigidez Vascular/fisiologia , Adolescente , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Teste de Esforço , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/métodos , Adulto Jovem
19.
Radiology ; 291(3): 774-780, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30938628

RESUMO

Background The Fontan operation is performed for surgical palliation of single ventricle physiology. This operation is usually preceded by a superior cavopulmonary connection (SCPC); lymphatic abnormalities after SCPC may be demonstrated at MRI and prior to the Fontan operation. Purpose To determine if the degree of neck and thoracic lymphatic abnormalities at T2-weighted MRI in patients after superior cavopulmonary connection (SCPC) correlated with surgical outcomes from the Fontan procedure. Materials and Methods Patients for whom SCPC was performed for palliation of single ventricle disease who underwent chest MRI between July 2012 and May 2015 at a single institution were retrospectively reviewed. T2-weighted images were scored as lymphatic type 1 (little or no T2 mediastinal and supraclavicular signal) to type 4 (T2 signal into both the mediastinum and the lung parenchyma). Fontan takedown, duration of post-Fontan hospitalization and pleural effusion, postoperative plastic bronchitis, need for transplant, and mortality were tabulated. The relationship between lymphatic type and clinical outcomes was evaluated by using analysis of variance (ANOVA), the Kruskal-Wallis H test, and the Fisher exact test. Results A total of 83 patients (mean age, 7.9 years ± 2.6) were evaluated. Among these 83 patients, 53 (64%) were classified with type 1 or 2 lymphatic abnormalities, 17 (20%) with type 3, and 12 (16%) with type 4. The rate of failure of Fontan completion was higher in patients with type 4 than in type 1 or 2 (54% vs 2%, respectively; P = .004). Need for cardiac transplant (one of 13 [8%]) and death (three of 13 [23%]) occurred only in type 4. Median postoperative length of stay was longer for patients with type 4 than for those with types 1 or 2 (29 days vs 9 days, respectively; P < .01). Conclusion Greater MRI-based severity of lymphatic abnormalities in patients prior to planned Fontan procedure was associated with failure of Fontan completion and longer postoperative stay. © RSNA, 2019 Online supplemental material is available for this article.


Assuntos
Técnica de Fontan , Anormalidades Linfáticas/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Criança , Pré-Escolar , Técnica de Fontan/efeitos adversos , Técnica de Fontan/mortalidade , Técnica de Fontan/estatística & dados numéricos , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Humanos , Tempo de Internação , Anormalidades Linfáticas/etiologia , Sistema Linfático/diagnóstico por imagem , Sistema Linfático/patologia , Imageamento por Ressonância Magnética , Pescoço/diagnóstico por imagem , Pescoço/patologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tórax/diagnóstico por imagem , Tórax/patologia , Resultado do Tratamento
20.
J Pediatr Hematol Oncol ; 41(1): e47-e50, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30080754

RESUMO

An open-label, pilot study was conducted to evaluate deferasirox/deferiprone combination chelation therapy in adult patients with transfusion-dependent thalassemia and severe iron overload. Enrollment proved difficult. Nine patients (median age, 27.4 y; ferritin, 4965 ng/mL; liver iron concentration, 28.5 mg/g dry weight; cardiac T2*, 13.3 ms) received treatment. Two were withdrawn for treatment-related adverse effects. Arthralgia (4 patients) and gastrointestinal symptoms (5 patients) were common; no episodes of neutropenia/agranulocytosis occurred. Adherence difficulties were common. Of 6 patients with 12 to 18 months follow-up, 3 showed improvement in cardiac T2* and 2 in liver iron. Combination oral chelation may be effective but adverse effects and adherence challenges may limit efficacy.


Assuntos
Transfusão de Sangue , Deferasirox/administração & dosagem , Deferiprona/administração & dosagem , Sobrecarga de Ferro/tratamento farmacológico , Talassemia/terapia , Adulto , Deferasirox/efeitos adversos , Deferiprona/efeitos adversos , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Sobrecarga de Ferro/etiologia , Masculino , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA