Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur J Vasc Endovasc Surg ; 66(6): 849-854, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37659740

RESUMO

OBJECTIVE: Inflow arterial aneurysms are a rare but serious complication after long term arteriovenous fistulae (AVF), probably due to arterial wall remodelling after an increase in flow and shear stress, and kidney transplantation with immunosuppressive therapy. This study aimed to describe the outcomes of surgical treatment and long term follow up in a large cohort. METHODS: This prospective cohort study collected data from patients with a true inflow artery aneurysm after AVF creation that was surgically repaired between 2010 and 2022. Anastomotic and infected aneurysms or post-puncture pseudoaneurysms were excluded. Demographic data, access characteristics, symptoms, treatment strategies, and long term follow up were recorded; patency was estimated using Kaplan-Meier survival analysis. RESULTS: During the study period, 28 patients (64% men, mean age 60.1 years) were treated surgically for aneurysmal degeneration of the axillary or brachial (n = 23) or radial (n = 5) artery after an AVF (10 distal, 18 proximal) performed a mean of 18.3 ± SD 7.9 years previously. Most AVFs were ligated or thrombosed, while all patients except one had previously received kidney transplants. Most of the cases (n = 18) were symptomatic: 13 with pain or swelling, four with distal embolisation, and one rupture. They were repaired by aneurysm partial excision and graft interposition (11 great saphenous vein, six ipsilateral basilic vein, three cephalic vein, and two PTFE graft), ligation (n = 3), or direct end to end anastomosis (n = 3). No major complications occurred before discharge, after a mean hospital stay of 2.4 days. After a mean follow up of 4.8 ± 3.3 years, three cases presented complications: two recurrent proximal brachial aneurysms were repaired with an additional proximal interposition graft (one with further late infected pseudoaneurysm) and an asymptomatic post-traumatic graft thrombosis. Five year primary and secondary patency was 84% and 96%, respectively. CONCLUSION: Aneurysmal degeneration of the inflow artery is an unusual complication during long term follow up of AVFs. Aneurysm excision and, in general, autogenous graft interposition using the saphenous or ipsilateral arm vein is a safe and effective strategy.


Assuntos
Aneurisma , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Diálise Renal/efeitos adversos , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Artérias/cirurgia , Veia Safena/cirurgia , Grau de Desobstrução Vascular , Estudos Retrospectivos , Artéria Braquial/cirurgia
2.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33978975

RESUMO

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Diálise Renal/instrumentação , Idoso , Idoso de 80 Anos ou mais , alfa-Globulinas/análise , Creatinina/sangue , Feminino , Hemodiafiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/sangue , Orosomucoide/análise , Segurança do Paciente , Prolactina/sangue , Estudos Prospectivos , Diálise Renal/métodos , Resultado do Tratamento , Ureia/sangue , Microglobulina beta-2/sangue
3.
J Vasc Access ; 22(3): 370-379, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32691665

RESUMO

INTRODUCTION: The surface of tunnelled cuffed catheters provides an optimal environment for the development of biofilms, which have recently been described as conditioning films because of the presence of adherent biological materials. These biofilms are associated with infection and thrombosis and potentially increase patients' inflammatory response. These complications could be reduced by the use of locking solutions. OBJECTIVE: To analyse biofilm formation, using confocal and electron microscopy, in tunnelled cuffed catheters locked with three different solutions and to determine the relationship between these solutions and inflammatory response. STUDY DESIGN: This prospective study included 35 haemodialysis patients with tunnelled cuffed catheter removal for non-infection-related reasons. The participants were divided into three groups according to the lock solution used: (1) heparin 1: 5000 IU; (2) citrate 4%; and (3) taurolidine 1.35%, citrate 4% and heparin 500 IU (taurolock); in the latter group, 25,000 IU taurolidine-urokinase was used in the last weekly session. All tunnelled cuffed catheters were cultured, and the inner surface was evaluated with confocal and electron microscopy. The inflammatory profile of included patients was determined at tunnelled cuffed catheter removal. RESULTS: There were no differences in clinical or demographic variables between the three subgroups. Biofilm thickness was lower in the taurolidine group than in the citrate 4% and heparin groups (28.85 ± 6.86 vs 49.99 ± 16.56 vs 56.2 ± 15.67 µm, respectively; p < 0.001), as was biofilm volume (1.01 ±1.18 vs 3.7 ± 2.15 vs 5.55 ±2.44, µm3, respectively; p < 0.001). The mean interleukin-6 value was 39%, which was 50% lower than in the citrate and heparin groups, but without significance differences. CONCLUSION: Our results show that biofilms were found in all tunnelled cuffed catheters, but the thickness and volume were significantly lower in tunnelled cuffed catheters locked with taurolidine solution. Therefore, the type of locking solution used in tunnelled cuffed catheters should maintain tunnelled cuffed catheter sterility and prevent catheter-related bloodstream infections. No significant difference was observed in the inflammatory profile according to the type of locking solution.


Assuntos
Anti-Infecciosos/administração & dosagem , Anticoagulantes/administração & dosagem , Biofilmes/efeitos dos fármacos , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres de Demora , Ácido Cítrico/administração & dosagem , Heparina/administração & dosagem , Inflamação/prevenção & controle , Diálise Renal/instrumentação , Taurina/análogos & derivados , Tiadiazinas/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos/efeitos adversos , Anticoagulantes/efeitos adversos , Biofilmes/crescimento & desenvolvimento , Infecções Relacionadas a Cateter/diagnóstico , Infecções Relacionadas a Cateter/microbiologia , Ácido Cítrico/efeitos adversos , Desenho de Equipamento , Feminino , Heparina/efeitos adversos , Humanos , Inflamação/sangue , Inflamação/etiologia , Mediadores da Inflamação/sangue , Interleucina-6/sangue , Masculino , Microscopia Confocal , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Diálise Renal/efeitos adversos , Propriedades de Superfície , Taurina/administração & dosagem , Taurina/efeitos adversos , Tiadiazinas/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
4.
Blood Purif ; 50(4-5): 531-538, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33352569

RESUMO

INTRODUCTION: COVID-19 is a highly contagious disease that has easily spread worldwide. Outpatient maintenance hemodialysis seems to entail an increased risk of contagion, and previous reports inform of increased mortality among this population. METHODS: We retrospectively analyzed clinical and laboratory parameters, outcomes, and management once discharged of CKD-5D patients infected with SARS-CoV-2 from our health area. RESULTS: Out of the 429 CKD-5D population, 36 were diagnosed with SARS-CoV-2 infection (8%): 34 on in-center hemodialysis and 2 on peritoneal dialysis. Five were asymptomatic. The most common symptom was fever (70%), followed by dyspnea and cough. History of cardiovascular disease and elevation of LDH and C-reactive protein during admission were associated with higher mortality. Thirteen patients died (36%), 8 patients were admitted to an ICU, and survival was low (38%) among the latter. The mean time to death was 12 days. Most discharged patients got negative rRT-PCR in nasopharyngeal swabs within 26 days of diagnosis. However, there is a portion of cured patients that continue to have positive results even more than 2 months after the initial presentation. CONCLUSIONS: Patients on dialysis have an increased mortality risk if infected with SARS-CoV-2. Preventive measures have proven useful. Thus, proper ones, such as universal screening of the population and isolation when required, need to be generalized. Better de-isolation criteria are necessary to ensure an appropriate use of public health resources.


Assuntos
COVID-19/epidemiologia , Isolamento de Pacientes , Insuficiência Renal Crônica/epidemiologia , SARS-CoV-2 , Assistência ao Convalescente , Idoso , Idoso de 80 Anos ou mais , Infecções Assintomáticas/epidemiologia , COVID-19/diagnóstico , COVID-19/prevenção & controle , COVID-19/transmissão , Teste para COVID-19 , Doenças Cardiovasculares/epidemiologia , Comorbidade , Diabetes Mellitus/epidemiologia , Dislipidemias/epidemiologia , Feminino , Febre/etiologia , Mortalidade Hospitalar , Humanos , Hospedeiro Imunocomprometido , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal , Prevalência , Prognóstico , Diálise Renal , Insuficiência Renal Crônica/terapia , Índice de Gravidade de Doença , Fumar/epidemiologia , Espanha/epidemiologia , Sobreviventes
5.
Artif Organs ; 44(10): E448-E458, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32279348

RESUMO

The aim of the study was to compare expanded hemodialysis (HDx) with hemodiafiltration (HDF) at different infusion flows to identify the main determinants, namely blood flow (Qb), replacement volume, infusion flow (Qi), ultrafiltration flow (Quf ), filtration fraction (FF), and the point at which the effectiveness of HDF equals or exceeds that of HDx. We conducted a prospective, single-center study in 12 patients. Each patient underwent 12 dialysis sessions: six sessions with Qb 350 and six with Qb 400 mL/min; with each Qb, one session was with HDx and five sessions were with FX80 (one in HD, and four with Qi 50, 75, 90/100 mL/min or autosubstitution in postdilution HDF). The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually and the global removal score (GRS) was calculated. The mean replacement volume with Qb 350 mL/min was 13.77 ± 0.92 L with Qi 50 mL/min, 20.75 ± 1.17 L with Qi 75, 23.83 ± 1.92 L with Qi 90, and 27.51 ± 2.77 L with autosubstitution. Similar results were obtained with Qb 400 mL/min, and the results were only slightly higher with Qi 100 mL/min or in autosubstitution. The GRS was positively correlated with replacement volume with Qb 350 (R2  = 0.583) and with Qb 400 (R2  = 0.584); with Quf with Qb 350 (R2  = 0.556) and with Qb 400 (R2  = 0.604); and also with FF with Qb 350 (R2  = 0.556) and with Qb 400 mL/min (R2  = 0.603). The minimum convective volume in HDF from which it is possible to overcome the efficacy of HDx was 19.2 L with Qb 350 and 17.6 L with Qb 400 mL/min. The cut-off point of Quf at which HDF exceeded the effectiveness of HDx was 80.6 mL/min with Qb 350 and 74.1 mL/min with Qb 400 mL/min. The cut-off point at which FF in HDF exceeded the effectiveness of the HDx was 23.0% with Qb 350 and 18.6% with Qb 400 mL/min. In conclusion, this study confirms the superiority of postdilution HDF over HDx when replacement volume, convective volume, Quf , or FF exceeds certain values. Increasing the Qb in postdilution HDF manages to increase the convective dose and more easily overcome the HDx.


Assuntos
Hemodiafiltração/estatística & dados numéricos , Falência Renal Crônica/terapia , Diálise Renal/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/urina , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
6.
Blood Purif ; 49(4): 400-408, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31865336

RESUMO

BACKGROUND: The biocompatibility of dialysis membranes is a determining factor in avoiding chronic microinflammation in patients under haemodialysis. Lower biocompatibility has been related to increased inflammatory status, which is known to be associated with cardiovascular events. Classically, cellulose membranes have been considered bioincompatible. A new-generation of asymmetric cellulose triacetate (CTA) membranes allows the performance of high convective transport techniques, but there have been no studies of their biocompatibility. The aim of the present study was to analyze and compare the biocompatibility characteristics of 4 membranes, including CTA, in online hemodiafiltration (OL-HDF) patients. METHODS: We included 15 patients in -OL-HDF. After a 2-week washout period with helixone membrane, each patient was treated with the 4 membranes (polyamide, polynephron, helixone and CTA) for 4 weeks in a randomized order. The other dialysis parameters were kept stable throughout the study. We studied changes in markers of the activation of the complement system, monocytes, platelets, and adhesion molecules with the 4 membranes, as well as inflammatory parameters. RESULTS: Biocompatibility was similar among the membranes. There were no sustained differences in complement activation, measured by C3a and C5a levels, or in platelet activation, determined by levels of P-selectin and platelet-derived microparticles (CD41a+). No differences were observed in activated monocyte levels (CD14+/CD16+) or in plasma levels of interleukin (IL)-1, IL-6, IL-10 or high-sensitivity C-reactive protein, although tumour necrosis factor-α levels decreased when the patients were dialyzed with CTA. No significant differences were found in markers of endothelial damage, assessed by levels of plasminogen activator inhibitor-1 and adhesion molecules (intercellular adhesion molecule-1 and vascular cell adhesion molecule-1). CONCLUSION: The 4 membranes evaluated in this study in stable patients on OL-HDF, including the new-generation CTA, show similar biocompatibility with the methods applied.


Assuntos
Materiais Biocompatíveis/química , Hemodiafiltração/instrumentação , Teste de Materiais , Membranas Artificiais , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis/efeitos adversos , Celulose/efeitos adversos , Celulose/análogos & derivados , Celulose/química , Ativação do Complemento , Feminino , Humanos , Interleucinas/sangue , Masculino , Pessoa de Meia-Idade , Ativação Plaquetária
7.
Artif Organs ; 43(10): 1014-1021, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31038748

RESUMO

Most high-flux dialyzers can be used in both hemodialysis (HD) and online hemodiafiltration (OL-HDF). However, some of these dialyzers have higher permeability and should not be prescribed for OL-HDF to avoid high albumin losses. The aim of this study was to compare the safety and efficacy of a currently used dialyzer in HD and OL-HDF with those of several other high permeability dialyzers which should only be used in HD. A prospective, single-center study was carried out in 21 patients. Each patient underwent 5 dialysis sessions with routine dialysis parameters: 2 sessions with Helixone (HD and postdilution OL-HDF) and 1 session each with steam sterilized polyphenylene, polymethylmethacrylate (PMMA), and medium cut-off (MCO) dialyzers in HD treatment. The removal ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. A proportional part of the dialysate was collected to quantify the loss of various solutes, including albumin. Urea and creatinine RRs with the Helixone-HDF and MCO dialyzers were higher than with the other 3 dialyzers in HD. The ß2 -microglobulin, myoglobin and prolactin RRs with Helixone-HDF treatment were significantly higher than those obtained with all 4 dialyzers in HD treatment. The ß2 -microglobulin value obtained with the MCO dialyzer was also higher than that obtained with the other 3 dialyzers in HD treatment. The myoglobin RR with MCO was higher than those obtained with Helixone and PMMA in HD treatment. The prolactin RR with Helixone-HD was significantly lower than those obtained in the other 4 study sessions. The α1 -microglobulin and α1 - acid glycoprotein RRs with Helixone-HDF were significantly higher than those obtained with Helixone and PMMA in HD treatment. The albumin loss varied from 0.54 g with Helixone-HD to 3.3 g with polyphenylene. The global removal score values ((UreaRR + ß2 -microglobulinRR + myoglobinRR + prolactinRR + α1 -microglobulinRR + α1 -acid glycoproteinRR - albuminRR )/6) were 43.7% with Helixone-HD, 47.7% with PMMA, 54% with polyphenylene, 54.8% with MCO and 59.6% with Helixone-HDF, with significant differences. In conclusion, this study confirms the superiority of OL-HDF over HD with the high-flux dialyzers that allow both treatments. Although new dialyzers with high permeability can only be used in HD, they are in an intermediate position and some are very close to OL-HDF.


Assuntos
Hemodiafiltração/instrumentação , Falência Renal Crônica/terapia , Idoso , alfa-Globulinas/isolamento & purificação , Soluções para Diálise/uso terapêutico , Feminino , Hemodiafiltração/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/isolamento & purificação , Permeabilidade , Prolactina/isolamento & purificação , Estudos Prospectivos , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Albumina Sérica/isolamento & purificação , Ureia/isolamento & purificação , Microglobulina beta-2/isolamento & purificação
8.
Blood Purif ; 48(2): 106-114, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30699421

RESUMO

BACKGROUND: Etelcalcetide is a novel second-generation calcimimetic that, because of its intravenous administration, could improve treatment adherence in secondary hyperparathyroidism (SHPT). The aim of this study was to evaluate the effectiveness of etelcalcetide compared with that of cinacalcet in controlling SHPT in patients under hemodialysis. METHODS: A prospective observational study was performed in 29 patients with SHPT under hemodialysis who switched from cinacalcet to etelcalcetide with a follow-up of 6 months. A survey was conducted of adherence to the oral calcimimetic. The primary end-point of the study was to assess whether etelcalcetide was more effective than cinacalcet in controlling SHPT. RESULTS: After the switch of treatment, none of the patients developed clinical intolerance or new adverse effects. Etelcalcetide was more effective than cinacalcet in controlling intact parathyroid hormone (iPTH), with an overall decrease in iPTH levels that was significant from the second month. Average calcium levels remained within the normal range, with a higher percentage of hypocalcemia with etelcalcetide (6.9 vs. 13.8%), which was asymptomatic in all cases. Patients who were nonadherent to cinacalcet (38%) showed a significant reduction in calcium and iPTH during follow-up with etelcalcetide. The adherent group (62%) also showed a trend to lower iPTH levels reaching statistical significance after 5 months of follow-up. The dose conversion factor for the switch from cinacalcet to etelcalcetide was etelcalcetide/session = 0.111*mg cinacalcet/day + 0.96, R2 = 0.57. CONCLUSIONS: Etelcalcetide was more effective than cinacalcet in this patient population, especially in the nonadherent subgroup, leading to better SHPT control without adverse effects.


Assuntos
Hormônios e Agentes Reguladores de Cálcio/uso terapêutico , Cinacalcete/uso terapêutico , Hiperparatireoidismo Secundário/tratamento farmacológico , Peptídeos/uso terapêutico , Administração Intravenosa , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Cálcio/sangue , Hormônios e Agentes Reguladores de Cálcio/administração & dosagem , Cinacalcete/administração & dosagem , Feminino , Humanos , Hiperparatireoidismo Secundário/sangue , Hiperparatireoidismo Secundário/terapia , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Peptídeos/administração & dosagem , Estudos Prospectivos , Diálise Renal , Adulto Jovem
9.
J Vasc Access ; 20(2): 195-201, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30117363

RESUMO

INTRODUCTION:: Ambulatory surgery is associated with lower costs, but there is lack of evidence of the safety for ambulatory vascular access surgery. The objective of this study is to substantiate the safety and effectiveness of performing vascular access surgery in an ambulatory setting. METHODS:: A review of our prospectively maintained database including all vascular access open surgeries (creations and repairs) performed by our Vascular Access Unit between 2013 and 2017 was compiled. Patient comorbidities, surgery details, hospital admission conditions, and 1-week and 1-month follow-up patency and complications (death, infection, bleeding, and readmission/reintervention) were scrutinized. RESULTS:: In the last 5 years, 1414 vascular access procedures were performed (67.8% access creations, 32.2% previous access repairs) in 1012 patients. Most surgeries were performed under local anesthesia (59.2%) or axillary plexus block (38.4%) and mainly in an ambulatory setting, without overnight hospital stays (90.9%). During the first postoperative week follow-up, 9 cases (0.6%) needed readmission or reintervention; significant infection materialized in 11 (0.8%) and 10 cases (0.7%) showed noteworthy hematoma or bleeding, only three (0.2%) requiring reintervention. The primary composite endpoint of 24-h death and 1 week readmission, reintervention, infection, or bleeding was 1.9% (27 cases); 1-month access failure was 6.2%. After univariate analysis, ambulatory settings were not related to higher rates of complications or readmissions. CONCLUSION:: Arteriovenous access surgery can be safely performed in an ambulatory setting, in spite of complex cases, comorbidities, or the increasing implementation of axillary plexus blocks. Surgical results and patency are good, and complications necessitating readmission remain very low.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/métodos , Derivação Arteriovenosa Cirúrgica/métodos , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Procedimentos Cirúrgicos Ambulatórios/mortalidade , Anestesia Local , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/mortalidade , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso , Segurança do Paciente , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
Nefrologia ; 37 Suppl 1: 1-191, 2017 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29248052

RESUMO

Vascular access for haemodialysis is key in renal patients both due to its associated morbidity and mortality and due to its impact on quality of life. The process, from the creation and maintenance of vascular access to the treatment of its complications, represents a challenge when it comes to decision-making, due to the complexity of the existing disease and the diversity of the specialities involved. With a view to finding a common approach, the Spanish Multidisciplinary Group on Vascular Access (GEMAV), which includes experts from the five scientific societies involved (nephrology [S.E.N.], vascular surgery [SEACV], vascular and interventional radiology [SERAM-SERVEI], infectious diseases [SEIMC] and nephrology nursing [SEDEN]), along with the methodological support of the Cochrane Center, has updated the Guidelines on Vascular Access for Haemodialysis, published in 2005. These guidelines maintain a similar structure, in that they review the evidence without compromising the educational aspects. However, on one hand, they provide an update to methodology development following the guidelines of the GRADE system in order to translate this systematic review of evidence into recommendations that facilitate decision-making in routine clinical practice, and, on the other hand, the guidelines establish quality indicators which make it possible to monitor the quality of healthcare.


Assuntos
Derivação Arteriovenosa Cirúrgica/normas , Diálise Renal/métodos , Dispositivos de Acesso Vascular/normas , Aneurisma/etiologia , Aneurisma/cirurgia , Angioplastia/métodos , Antibioticoprofilaxia/normas , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Cateterismo Periférico/normas , Tomada de Decisão Clínica , Constrição Patológica , Falha de Equipamento , Medicina Baseada em Evidências , Humanos , Controle de Infecções , Agulhas , Exame Físico , Reologia , Espanha , Trombose/etiologia , Trombose/prevenção & controle , Trombose/terapia , Dispositivos de Acesso Vascular/efeitos adversos
11.
Cardiovasc Intervent Radiol ; 40(2): 252-259, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27896413

RESUMO

PURPOSE: To evaluate the efficacy and safety of the hydrodynamic thrombectomy catheter (AngioJet DVX) in the salvage of thrombosed hemodialysis vascular grafts. MATERIALS AND METHODS: A retrospective study was designed, including all patients with occluded arteriovenous grafts treated with the AngioJet system between 2007 and 2014 in our institution. Outcomes included technical success, clinical success, complications, and primary and secondary patencies. Procedural success was defined as angiographic confirmation of flow restoration, the presence of a pulsatile thrill along the graft, and successful resumption of at least one hemodialysis session. Primary and secondary patencies after first AVG thrombectomy were calculated with Kaplan-Meier curves. Cox regression was used to determine prognostic factors of primary patency after every thrombectomy episode. RESULTS: A total of 149 thrombectomies were performed in 68 grafts. After thrombectomy, endovascular treatment of one or more stenosis was performed in all cases. Technical success was 93% and clinical success was 86%. Complications occurred in 7 thrombectomies, most of them were minor except for one anastomosis rupture requiring surgery. Primary and secondary patencies were 52, 41, and 23 and 76, 68, and 57% at 3, 6 and 12 months, respectively. Independent prognostic factors of poor patency after every thrombectomy episode were the presence of residual thrombus (OR 1.831, P = 0.008) and time from last thrombosis (less than 1 month; and OR 7.116, P < 0.001). CONCLUSION: Percutaneous mechanical thrombectomy with AngioJet is a safe technique with a high-clinical success rate. The presence of residual thrombus after thrombectomy and early re-occlusions are related to poorer results.


Assuntos
Procedimentos Endovasculares/métodos , Oclusão de Enxerto Vascular/cirurgia , Diálise Renal/instrumentação , Trombectomia/instrumentação , Trombectomia/métodos , Idoso , Catéteres , Feminino , Humanos , Hidrodinâmica , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
Hemodial Int ; 20(2): 306-14, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26486682

RESUMO

Exercises after arteriovenous fistula (AVF) creation may help to improve maturation; however, their usefulness has only been examined in indirect, non-comparative studies or small trials. Between June 2013 and November 2014, we included all ambulatory patients with stages 5-5D chronic kidney disease who were candidates for the creation of a native AVF in our center. After surgery, all patients were randomized to an exercise group or a control group with single-blind control. At 1 month postoperatively, clinical maturation (expert nurse inspection) and ultrasonographic maturation (flow >500 mL/min, venous diameter >5 mm and depth <6 mm) were assessed in all patients. A total of 72 patients were randomized, 3 were lost to follow-up, and 69 were finally analyzed. The mean age was 66.8 years (standard deviation 13.8), 70.0% were men, and 65.2% were in pre-dialysis. After surgery (42.0% had distal AVF), the patients were randomized (31 controls, 38 exercise group). At 1 month after surgery, global clinical and ultrasonographic maturation was assessed in 88.4% and 78.3% of AVF, respectively (kappa = 0.539). Non-significant differences in clinical or ultrasonographic maturation were seen between exercise and control group (94.7% vs. 80.6%, P = 0.069; 81.6% vs. 74.2%, P = 0.459). A stepwise logistic regression was performed to control previously analyzed asymmetrically distributed confounding factors (AVF localization), revealing that the exercise group showed greater clinical, but not ultrasonographic, maturation (odds ratio [OR] 5.861, 95% confidence interval: 1.006-34.146 and OR 2.403, 0.66-8.754). A postoperative controlled exercise program after AVF creation seems to increase 1-month clinical AVF maturation in distal accesses. Furthermore, exercise programs should be taken into account, especially in distal accesses.


Assuntos
Fístula Arteriovenosa/reabilitação , Derivação Arteriovenosa Cirúrgica/reabilitação , Exercício Físico/fisiologia , Diálise Renal/efeitos adversos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Insuficiência Renal Crônica
13.
Antimicrob Agents Chemother ; 58(7): 4180-4, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24820084

RESUMO

Mortality and morbidity are significantly higher among patients with dialysis catheters, which has been associated with chronic activation of the immune system. We hypothesized that bacteria colonizing the catheter lumen trigger an inflammatory response. We aimed to evaluate the inflammatory profile of hemodialysis patients before and after locking catheters with an antimicrobial lock solution. High-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6), IL-10, and tumor necrosis factor alpha (TNF-α) were measured in serum, and levels of mRNA gene expression of IL-6, IL-10, and TNF-α were analyzed in peripheral blood mononuclear cells (PBMC). Samples were obtained at baseline and again after 3 months' use of taurolidine-citrate-heparin lock solution (TCHLS) in 31 hemodialysis patients. The rate of catheter-related bloodstream infections (CRBSI) was 1.08 per 1,000 catheter-days in the heparin period and 0.04 in the TCHLS period (P = 0.023). Compared with the baseline data, serum levels of hs-CRP and IL-6 showed median percent reductions of 18.1% and 25.2%, respectively (P < 0.01), without significant changes in TNF-α or IL-10 levels. Regarding cytokine gene expression in PBMC, the median mRNA expression levels of TNF-α and IL-6 decreased by 20% (P < 0.05) and 19.7% (P = 0.01), respectively, without changes in IL-10 expression levels. The use of TCHLS to maintain the catheter lumen sterility significantly reduces the incidence of CRBSI and improves the inflammatory profile in hemodialysis patients with tunneled catheters. Further studies are needed to evaluate the potential beneficial effects on clinical outcomes.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateteres Venosos Centrais/microbiologia , Ácido Cítrico/uso terapêutico , Heparina/uso terapêutico , Taurina/análogos & derivados , Tiadiazinas/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Anticoagulantes , Proteína C-Reativa/análise , Infecções Relacionadas a Cateter/tratamento farmacológico , Feminino , Humanos , Inflamação/tratamento farmacológico , Inflamação/prevenção & controle , Interleucina-10/sangue , Interleucina-10/genética , Interleucina-6/sangue , Interleucina-6/genética , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/biossíntese , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Diálise Renal/mortalidade , Taurina/uso terapêutico , Fator de Necrose Tumoral alfa/sangue , Fator de Necrose Tumoral alfa/genética
14.
Nefrologia ; 34(2): 235-42, 2014.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-24658200

RESUMO

OBJECTIVE: Steal syndrome is a severe complication of vascular access. Our aim is to present the initial results of a simple and effective treatment: the interposition of a prosthetic segment in the juxta-anastomotic vein. METHOD: Between 2009 and 2012, 14 patients (57 % male, average age 71) with severe steal syndrome due to vascular access (stages II-IV), following a clinical and systematic echographic study and a selective angiographic study, were treated through the interposition of a 6 mm segment of PTFE in the juxta-anastomotic vein, in addition to selective patch repair of arterial stenosis (2 cases) or ligature of useless venous collaterals (8 cases). Local or regional anaesthesia was used and outpatient care was given in all cases. RESULTS: There was 100 % technical success. The pre- and post-operative echographical study showed a reduction of post-operative access flow by 39 % and an increase of radial artery flow by 477 %. Ischaemic symptoms were resolved in 12 patients (86 %); the other two patients required additional procedures due to persistent ischaemic symptoms. There was a post-operative venous rupture, which required a definitive ligation. No patient suffered amputations, nor were there losses or access thrombosis during the follow-up. The primary and primary-assisted patencies free of new ischemic symptoms were 78 % and 78 % at 12 months, and 62 % and 78 % at 24 months. CONCLUSIONS: The interposition of a prosthetic segment in the juxta-anastomotic vein is a simple, quick and effective technique in the treatment of vascular steal syndrome, with promising results at the 2 year follow-up.


Assuntos
Dispositivos de Acesso Vascular/efeitos adversos , Doenças Vasculares/etiologia , Doenças Vasculares/cirurgia , Idoso , Anastomose Cirúrgica , Prótese Vascular , Feminino , Humanos , Masculino , Estudos Prospectivos , Síndrome , Procedimentos Cirúrgicos Vasculares/métodos , Veias/cirurgia
15.
Blood Purif ; 28(3): 268-74, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19684394

RESUMO

As a change from Diapes to polyphenylene membrane in the mid-dilution filter has recently been developed, the aim of this study was to compare mid-dilution using this new dialyzer versus pre- and postdilution. The prospective study included 20 patients who underwent 4 hemodiafiltration (HDF) sessions: 1.7 m(2) polyphenylene and predilution infusion flow (Qi) 200 ml/min, 1.7 m(2) and postdilution Qi 100 ml/min, 1.9 and 2.2 m(2) mid-dilution both with Qi 200 ml/ min. The urea and creatinine reduction ratios were slightly higher in postdilution. The beta(2)-microglobulin (85.8%), myoglobin (73.6%), prolactin (67.8%) and retinol-binding protein (29.2%) reduction ratios with 1.9 m(2) mid-dilution, which was similar to 2.2 m(2) mid-dilution, were significantly higher than with the post- and predilution modes. Mid-dilution appears to be a good HDF alternative that allows a better removal of larger molecules than postdilution and, mainly, predilution. Mid-dilution using 1.9 or 2.2 m(2) dialyzers, at the same convective volume, showed a similar removal.


Assuntos
Hemodiafiltração/métodos , Hemodiluição/métodos , Membranas Artificiais , Adulto , Idoso , Idoso de 80 Anos ou mais , Proteínas Sanguíneas/análise , Creatinina/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ureia/sangue
16.
Nephron Clin Pract ; 112(3): c164-70, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19390217

RESUMO

BACKGROUND/AIM: Cystatin C (Cys C) is an endogenous marker of glomerular filtration rate (GFR) unaffected by body composition. The aim of the present study was to assess the utility of Cys C-based GFR prediction equations (Hoek, Larsson and Stevens) and creatinine (modification of diet in renal disease-isotope dilution mass spectrometry--MDRD-IDMS, and Cockcroft-Gault--CG) compared with 51Cr-EDTA. METHODS: This study was carried out in 40 Caucasian older patients with advanced age (> or = 60) and chronic kidney disease stages 3-4. To assess the utility of prediction equations in relation to body composition, we measured lean mass (LM) with densitometry (DXA). Pearson's, Bland-Altman and Lin's coefficient (Rc) were used to study accuracy and precision. RESULTS: 51Cr-EDTA was 36.9 +/- 9.2 ml/min/1.73 m2 (22-60). Cys C levels were 2.2 +/- 0.8 mg/l (r = 0.085; p = 0.662 LM) and creatinine 2.8 +/- 1.1 mg/dl (r = 0.427; p = 0.021 LM). The most accurate equations were the Hoek, Larsson and Stevens formulae, with a bias of -0.2 (Rc 0.48), -2.9 (Rc 0.44) and 2.6 ml/min/1.73 m2 (Rc 0.58). The biases obtained with MDRD-IDMS and CG were -14.6 (Rc 0.35) and -12.5 (Rc 0.40). All correlations among biases obtained with creatinine-based formulae and LM were negative and statistically significant (p < 0.05). CONCLUSIONS: The results show superiority of Cys C-based GFR formulae over the MDRD-IDMS and CG equations. This significant underestimation obtained with conventional prediction equations was directly related to the influence of LM.


Assuntos
Algoritmos , Cistatina C/urina , Diagnóstico por Computador/métodos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/urina , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/urina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA