Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36709469

RESUMO

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Assuntos
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedância Elétrica , Estudos Retrospectivos , Fibrilação Ventricular , Desfibriladores Implantáveis
3.
Heart Rhythm ; 19(12): 1958-1964, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35781042

RESUMO

BACKGROUND: The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited. OBJECTIVE: The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors. METHODS: All patients implanted with an S-ICD were enrolled from the multicenter, real-world iSUSI (International SUbcutaneouS Implantable cardioverter defibrillator) Registry. The need for a TV device and its clinical reason, and appropriate and inappropriate device therapies were assessed. Logistic regression with Firth penalization was used to assess the association between baseline and procedural characteristics and the overall need for a subsequent TV device. RESULTS: A total of 1509 patients were enrolled (age 50.8 ± 15.8 years; 76.9% male; 32.0% ischemic; left ventricular ejection fraction 38% [30%-60%]). Over 26.5 [13.4-42.9] months, 155 (10.3%) and 144 (9.3%) patients experienced appropriate and inappropriate device therapies, respectively. Forty-one patients (2.7%) required a TV device (13 bradycardia; 10 need for CRT; 10 inappropriate shocks). Body mass index (BMI) >30 kg/m2 and chronic kidney disease (CKD) were associated with need for a TV device (odds ratio [OR] 2.57 [1.37-4.81], P = .003; and OR 2.67 [1.29-5.54], P = .008, respectively). CONCLUSION: A low rate (2.7%) of conversion from S-ICD to a TV device was observed at follow-up, with need for antibradycardia pacing, ATP, or CRT being the main reasons. BMI >30 kg/m2 and CKD predicted all-cause need for a TV device.


Assuntos
Desfibriladores Implantáveis , Insuficiência Renal Crônica , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Volume Sistólico , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Trifosfato de Adenosina
4.
Hellenic J Cardiol ; 65: 1-7, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35331905

RESUMO

OBJECTIVE: Cryoballoon (CB) and laser-balloon (LB) catheter ablation (CA) has been demonstrated to achieve durable and effective pulmonary vein isolation (PVI). Only one head-to-head comparison with an intermittent rhythm monitor strategy is currently available. The aim of this study was to compare acute and long-term outcomes of CB and LB atrial fibrillation ablation procedures, by using a continuous rhythm monitoring strategy. METHODS: This was a prospective two-arm nonrandomized propensity-matched observational trial that compared the outcomes of atrial fibrillation (AF) ablation using LB and CB techniques. To evaluate AF recurrences, an implantable cardiac monitor (ICM) was implanted before hospital discharge to detect atrial tachyarrhythmia (ATA) recurrences. RESULTS: A total of 110 propensity-matched patients undergoing AF ablation with an LB (n = 55) or with a CB system (n = 55) were enrolled (paroxysmal AF 57.3%). Procedural time (LB: 87 [73-104] vs. CB 90 [70-130] min; p = 0.264) and fluoroscopy time did not differ. No differences in ATA recurrences were observed at 12 months (LB-30.9% vs. CB-29.1% and LB-45.5% vs. CB-38.2%; log-rank 0.539). As for AF burden, the 12-month median was 0 [0-1] vs. 0 [0-3]% (p = 0.127) in the LB and CB groups, respectively. When considering only PeAF patients, the median 12-month ATA burden was 26 [18.5-40.5] vs. 29 [26-35]% (p = 0.919) for the LB and CB patients, respectively. CONCLUSION: In a propensity-matched cohort undergoing AF ablation, arrhythmia outcomes assessed by continuous rhythm monitoring did not differ between LB and CB, with an overall low ATA burden. The only predictor of recurrences was persistent AF. There was no difference in procedure or fluoroscopy time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Lasers , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
Heart Rhythm ; 19(7): 1109-1115, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35257974

RESUMO

BACKGROUND: A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking. OBJECTIVES: The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation. METHODS: Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry. The primary outcome was the comparison of inappropriate shock rate. Complications, freedom from sustained ventricular arrhythmias, and overall and cardiovascular mortality were deemed secondary outcomes. RESULTS: Teenagers + young adults represented 11.0% of the entire cohort. Two propensity-matched groups of 161 patients each were used for the analysis. Median follow-up was 23.1 (13.2-40.5) months. In total, 15.2% patients experienced inappropriate shocks, and 9.3% device-related complications were observed, with no age-related differences in inappropriate shocks (16.1% vs 14.3%; P = .642) and complication rates (9.9% vs 8.7%; P = .701). At univariate analysis, young age was not associated with increased rates of inappropriate shocks (hazard ratio [HR] 1.204 [0.675-2.148]: P = .529). At multivariate analysis, use of the SMART Pass algorithm was associated with a strong reduction in inappropriate shocks (adjusted HR 0.292 [0.161-0.525]; P <.001), whereas arrhythmogenic right ventricular cardiomyopathy (ARVC) was associated with higher rates of inappropriate shocks (adjusted HR 2.380 [1.205-4.697]; P = .012). CONCLUSION: In a large multicenter registry of propensity-matched patients, use of the S-ICD in teenagers/young adults was safe and effective. The rates of inappropriate shocks and complications between cohorts were not significantly different. The only predictor of increased inappropriate shocks was a diagnosis of ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Displasia Arritmogênica Ventricular Direita/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento , Adulto Jovem
6.
J Interv Card Electrophysiol ; 64(2): 273-280, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33683552

RESUMO

BACKGROUND: Catheter-based or surgical procedures in patients with long-standing persistent atrial fibrillation (LSPAF) remain a challenge. As a result, different approaches including hybrid (surgical and endocardial) ablation have been developed. Bachmann's bundle (BB) is a mainly epicardial structure capable of sustaining arrhythmic reentry that could be involved in the development and perpetuation of atrial fibrillation. We investigated the efficacy and safety of an adjunctive BB ablation in LSPAF patients undergoing hybrid ablation. METHODS: In a two-arm non-randomized study, consecutive LSPAF patients undergoing epicardial isolation of pulmonary veins with left atrial posterior wall (box lesion) with (n = 30, BB group) and without additional BB ablation (n = 30, CONV group) were enrolled in the study. All patients underwent an endocardial procedure within 6 weeks post-surgery to assess for potential lesion gaps and additional atrial substrate modification. The primary endpoint was freedom from AF through 12 months of follow-up. RESULTS: The two-staged hybrid ablation was successfully completed in all patients. One-year freedom from atrial arrhythmias recurrence rates was 96.6% in the BB group vs 76.6% in the CONV group (p = 0.025). At procedure completion, 30 (100%) and 17 (56%) patients had a spontaneous cardioversion in BB and CONV group, respectively (p < 0.001). No significant differences in quality of life or complication rates were observed. CONCLUSIONS: This initial experience shows, for the first time, that adjunctive BB ablation in the setting of hybrid ablation for LSPAF is a feasible and effective approach in increasing maintenance of sinus rhythm without increasing complication rates.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Estudo de Prova de Conceito , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 23(9): 1380-1390, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33837418

RESUMO

AIMS: Balloon-based technologies have been developed to simplify catheter ablation of atrial fibrillation (AF), to improve the clinical outcome of the procedure and to achieve durable pulmonary vein isolation (PVI). The objective of this study is to evaluate the safety and efficacy of second-generation laser balloon (LB2) ablation in the treatment of AF using a continuous cardiac rhythm monitoring strategy. Atrial tachyarrhythmias (ATas) recurrences were assessed with implantable cardiac monitors (ICMs) or devices. METHODS AND RESULTS: All patients underwent LB2 ablation procedure. The primary endpoint was the first recurrence of any, >5.5 and >24 h duration ATas after the blanking period (90 days). In-hospital visits were performed at 3, 6, and 12 months. Seventy-three patients (68% male, mean age 59.8 ± 11.3) were included in the study. The average procedure, fluoroscopy, and laser ablation times were 81.5 ± 30.1, 21.5 ± 12.4, and 33.8 ± 9.7, respectively. All PVs were isolated using the LB2 with no need of touch-up using focal catheters. No major complications occurred during or after the procedures. The one-year freedom from recurrences was 66.9% (95% CI: 57.0-76.7%), 81.0% (69.5-88.5%), and 86.8% (76.1-92.9%) considering any, 5.5-h and 24-h cut-off duration, respectively. At 3, 6, and 12 months, any ATas was recorded in 22%, 32%, and 25% of patients, with a ≥5% arrhythmic burden documented in 4%, 5%, and 3%, respectively. Few patients reported AF-related symptoms (7%, 8%, and 5%). CONCLUSION: LB2 ablation is a safe and effective procedure, showing a high freedom from recurrences and low arrhythmic burden as documented by a continuous rhythm monitoring strategy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
Eur Heart J Case Rep ; 4(FI1): 1-6, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33089046

RESUMO

BACKGROUND: Coronavirus disease 2019 (COVID-19) has been associated with myocardial involvement. Among cardiovascular manifestations, cardiac arrhythmias seem to be fairly common, although no specifics are reported in the literature. An increased risk of malignant ventricular arrhythmias and electrical storm (ES) has to be considered. CASE SUMMARY: We describe a 68-year-old patient with a previous history of coronary artery disease and severe left ventricular systolic disfunction, who presented to our emergency department describing cough, dizziness, fever, and shortness of breath. She was diagnosed with COVID-19 pneumonia, confirmed after three nasopharyngeal swabs. Ventricular tachycardia (VT) storm with multiple implantable cardioverter defibrillator (ICD) shocks was the presenting manifestation of cardiac involvement during the COVID-19 clinical course. A substrate-based VT catheter ablation procedure was successfully accomplished using a remote navigation system. The patient recovered from COVID-19 and did not experience further ICD interventions. DISCUSSION: To date, COVID-19 pneumonia associated with a VT storm as the main manifestation of cardiac involvement has never been reported. This case highlights the role of COVID-19 in precipitating ventricular arrhythmias in patients with ischaemic cardiomyopathy who were previously stable.

9.
J Cardiovasc Electrophysiol ; 31(5): 1166-1174, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141116

RESUMO

INTRODUCTION: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs. METHODS: The Italian registry on multipoint left ventricular pacing is a prospective, multicenter registry of patients implanted with MPP-enabled CRT devices. For this analysis, clinical and echocardiographic data were collected through 24 months and compared between patients with (MPP-ON) or without (MPP-OFF) early MPP activation at implant. The total cost of each HFH was estimated with national Italian reimbursement rates. RESULTS: The study included 190 MPP-OFF and 128 MPP-ON patients with similar baseline characteristics. At 1 and 2 years, the MPP-ON group had lower rates of HFH vs MPP-OFF (1-year hazard ratio [HR]: 0.14, P = .0014; 2-year HR: 0.38, P = .009). The finding persisted in a subgroup of patients with consistent MPP activation through follow-up (1-year HR: 0.19; P = .0061; 2-year HR: 0.39, P = .022). Total HFH per-patient costs were lower in the MPP-ON vs the MPP-OFF group at 1 year (€101 ± 50 vs €698 ± 195, P < .001) and 2 years (€366 ± 149 vs €801 ± 203, P = .038). More MPP-ON patients had ≥5% improvement in ejection fraction (76.8% vs 65.4%, P = .025) and clinical composite score (66.7% vs 47.5%, P = .01). CONCLUSIONS: In this multicenter clinical study, early MPP activation was associated with a significant reduction in cumulative HFH and related costs after 1 and 2 years of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Hospitalização/economia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
J Cardiovasc Electrophysiol ; 30(12): 2885-2891, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31661172

RESUMO

BACKGROUND: Multipoint pacing (MPP) may improve clinical outcomes in patients with cardiac resynchronization therapy defibrillators (CRT-D), but its impact on battery longevity in a real-world population has not been investigated in large trials. OBJECTIVE: Compare projected battery longevity in CRT-D patients with and without MPP during long-term follow-up. METHODS: The Italian registry on multipoint left ventricular pacing (IRON-MPP) is a prospective, multicenter registry of patients implanted with MPP-capable CRT-D devices. Projected battery longevity during follow-up was compared for patients with MPP (MPP ON) vs single-site (MPP OFF) left ventricular pacing at CRT-D implantation. A sub-analysis excluded crossover patients with MPP activation or deactivation occurring after implantation. A second sub-analysis excluded patients with a right or left ventricular pacing amplitude >2.5 V. RESULTS: Out of 237 CRT-D patients (71 ± 9 years, 81% male) followed for 1.9 ± 0.8 years, 102 (43%) had MPP ON at implantation. Programmed atrial and ventricular outputs and percentage of pacing were similar between groups. MPP was associated with a 0.44 years reduction in projected battery longevity (P = .03) during long-term follow-up. Results were similar for the first and second sub-analyses, with a 0.57 years (P < .001) and 0.71 years (P < .001) reduction in projected longevity, respectively. CONCLUSION: In this long-term real-world registry, early MPP activation is associated with less than a 1-year reduction in projected battery life compared to single-site biventricular pacing.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica , Falha de Equipamento , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
12.
Europace ; 19(7): 1170-1177, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27189954

RESUMO

AIMS: This registry was created to describe the experience of 76 Italian centres with a large cohort of recipients of multipoint pacing (MPP) capable cardiac resynchronization therapy (CRT) devices. METHODS AND RESULTS: A total of 507 patients in whom these devices had been successfully implanted were enrolled between August 2013 and May 2015. We analysed: (i) current clinical practices for the management of such patients, and (ii) the impact of MPP on heart failure clinical composite response and on the absolute change in ejection fraction (EF) at 6 months. Multipoint pacing was programmed to 'ON' in 46% of patients before discharge. Methods of optimizing MPP programming were most commonly based on either the greatest narrowing of the QRS complex (38%) or the electrical delays between the electrodes (34%). Clinical and echocardiographic follow-up data were evaluated in 232 patients. These patients were divided into two groups according to whether MPP was programmed to 'ON' (n = 94) or 'OFF' (n = 138) at the time of discharge. At 6 months, EF was significantly higher in the MPP group than in the biventricular-pacing group (39.1 ± 9.6 vs. 34.7 ± 7.6%; P < 0.001). Even after adjustments, early MPP activation remained an independent predictor of absolute increase in LVEF of ≥5% (odds ratio 2.5; P = 0.001). At 6 months, an improvement in clinical composite score was recorded in a greater proportion of patients with MPP-ON than in controls (56 vs. 38%; P = 0.009). On comparing optimal MPP and conventional vectors, QRS was also seen to have decreased significantly (P < 0.001). CONCLUSION: This study provides information that is essential in order to deal with the expected increase in the number of patients receiving MPP devices in the coming years. The results revealed different practices among centres, and establishing the optimal programming that can maximize the benefit of MPP remains a challenging issue. Compared with conventional CRT, MPP improved clinical status and resulted in an additional increase in EF. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrial.gov/. Unique identifier: NCT02606071.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Disparidades em Assistência à Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 42(1): 59-66, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25504267

RESUMO

PURPOSE: Small single-center comparative studies suggest improved outcomes in cardiac resynchronization therapy (CRT) patients implanted with a quadripolar left ventricular (LV) lead in comparison with non-quadripolar (bipolar) leads. This study represents the first large multicenter prospective registry comparing implant and 6-month postoperative lead performance following CRT-defibrillator (CRT-D) implantation with quadripolar vs. bipolar leads. METHODS: During a 39-month period, 418 consecutive patients having CRT-D implantation attempts with either a quadripolar (n = 230) or bipolar LV lead (n = 188) were enrolled in the registry. The primary outcome of the study was LV lead failure defined as any abnormality, excluding infection, resulting in surgical lead revision or CRT termination. Additionally, operative and follow-up data were analyzed for significant difference between groups. RESULTS: Baseline characteristics of both groups were similar. In 72.9 % of quadripolar leads versus 65.0 % of bipolar leads, the LV lead successfully engaged the predefined ideal target side branch (p = 0.47). Implant duration and fluoroscopy times were significantly shorter when a quadripolar lead was used (p = 0.007 and p = 0.001, respectively). The primary end point occurred in six patients (2.7 %) in the quadripolar group and in 14 patients (8.0 %) in the bipolar group (p = 0.02). Clinically significant phrenic nerve stimulation (PNS) occurred in 4.6 vs. 14.2 % of quadripolar vs. bipolar patients, respectively (p = 0.002); all PNS were resolved noninvasively through programming in the quadripolar group vs. 84 % in bipolar group (p = 0.75). The use of a bipolar lead was associated with a higher risk of surgical LV lead revision (6.3 vs. 2.3 %; p = 0.057) and a higher incidence of dislodgment (5.7 vs. 2.7 %; p = 0.16). CONCLUSIONS: This multicenter study demonstrates that the use of a quadripolar LV lead results in significantly lower rates of lead-related problems and reduced procedural and fluoroscopic times for biventricular system implantation. This has important implications for LV pacing lead choice.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Insuficiência Cardíaca/prevenção & controle , Duração da Cirurgia , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Análise de Falha de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Itália , Estudos Longitudinais , Masculino , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico
14.
Int J Cardiol ; 168(4): 3968-70, 2013 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-23886532

RESUMO

Whether and to what extent patients with asymptomatic atrial fibrillation (AF) would benefit from catheter ablation has not been investigated. This is the first multicenter prospective study reporting on the outcome of catheter ablation in patients with asymptomatic AF. Consecutive patients (n = 545) referred for AF ablation were prospectively enrolled in a multicenter Italian registry. Of these patients, 54 have asymptomatic AF and composed our patient population. At 24 month follow-up, catheter ablation in asymptomatic AF patients resulted to be as safe and effective as in patients with drug refractory symptomatic AF. Our study provides significant insights on the role of AF ablation in asymptomatic patients. Further studies in much larger cohorts are needed to validate our conclusions.


Assuntos
Doenças Assintomáticas/epidemiologia , Doenças Assintomáticas/terapia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Registros , Idoso , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 37(1): 87-95, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23397247

RESUMO

AIMS: Clinical trials have established that atrial fibrillation (AF) catheter ablation improves symptoms in appropriately selected patients. Confirmation of these results by long-term prospective observational studies is needed. This registry was created to describe the experience of 16 Italian centers with a large cohort of AF patients treated with catheter ablation guided by the NavX 3D mapping system. METHODS: From November 2006 to May 2008, 545 consecutive patients (age 60.4 ± 9.8, 67 % male) with paroxysmal (44 %), persistent (43 %), and long-standing persistent (13 %) AF referred for catheter ablation guided by the NavX system, were included in this registry. For this paper, follow-up was censored at 24 months; however, patients are being followed in the ongoing registry. RESULTS: Before the ablation, 80 % of patients failed to respond to at least one antiarrhythmic drug aimed at rhythm control. Pulmonary vein (PV) isolation guided by a circular mapping catheter was performed in 70 % of patients whereas non potential-guided PV encircling was performed in 30 % of patients. In 67 % of patients, additional left atrial (LA) substrate modification was performed. Image integration was performed in 9.2 % of patients. Considering a 3-month blanking period, after a single-ablation procedure, the patients had 1- and 2-year freedom from AF recurrence of 67.4 and 57.0 % (36.1 % off antiarrhythmic drugs), respectively. Cox regression analysis showed that AF recurrences during blanking (HR 2.1), and previous AF ablation (HR 3.3) were independent predictors of AF recurrences. Major procedure-related complications occurred in 53 patients (9.7 %). In 35 patients (6.7 %), a repeat procedure was performed at a median of 5 months after the initial procedure. CONCLUSIONS: This prospective, multicenter clinical experience provides significant insights into current ablation care of patients with AF. Despite favorable outcomes, real-world complication rates appear higher than previously recognized.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/mortalidade , Imageamento Tridimensional/estatística & dados numéricos , Sistema de Registros , Cirurgia Assistida por Computador/mortalidade , Fibrilação Atrial/diagnóstico , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Imageamento Tridimensional/métodos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Taxa de Sobrevida , Resultado do Tratamento
16.
Ann Thorac Surg ; 95(3): 1081-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23438538

RESUMO

Perforation and migration of pacemaker electrodes into the pleural cavity is a rare event. We report the clinical course and surgical treatment of massive acute hemothorax resulting from intercostal artery laceration, caused by a retained active-fixation pacing lead implanted 10 months earlier.


Assuntos
Bloqueio Atrioventricular/terapia , Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Hemotórax/etiologia , Marca-Passo Artificial/efeitos adversos , Doença Aguda , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Seguimentos , Hemotórax/diagnóstico , Hemotórax/cirurgia , Humanos , Fatores de Tempo , Tomografia Computadorizada por Raios X
17.
Clin Cardiol ; 35(2): 107-10, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22125099

RESUMO

BACKGROUND: The neurally mediated syncope (NMS) is sustained by complex cardiac and vascular reflexes, acting on and amplified by central autonomic loops, resulting in bradycardia and hypotension. HYPOTHESIS: Our aim was to assess whether the pathophysiology of NMS is also related to an abnormal peripheral vasoreactivity. METHODS: We evaluated by ultrasound the flow-mediated vasodilation (FMD) and the nitrate-mediated dilation (NMD) in 17 patients with NMS, induced by drug-free tilt test in 6 subjects and by nitrate-potentiated tilt test in the other 11 cases; the syncope was classified as vasodepressive (VD) in 8 cases, cardioinhibitory (CI) in 7, and mixed in 2. RESULTS: The FMD was not different from controls (10.2 ± 4.5 vs 11.4 ± 3.9, P = ns), with normal recovery times; the NMD was greater in fainting subjects than in controls (26.7 ± 7.3 vs 19.0 ± 3.6, P < 0.05), with higher values in VD than in CI syncope (31.1 ± 7.0 vs 23.1 ± 5.0, P = ns); compared to controls, subjects with NMS showed normal recovery times after FMD but longer recovery times after nitrate administration (13.0 ± 5.6 vs 6.3 ± 0.7 minutes, P < 0.05). CONCLUSIONS: The evaluation of endothelial function supports evidence that NMS is characterized by a marked and sustained endothelial-independent vasodilation, in the presence of a normal FMD; vascular hyperreactivity in response to nitrate administration is particularly overt in vasodepressive syncope and can explain the high rate of responses to nitrate administration during tilt test.


Assuntos
Endotélio Vascular/fisiopatologia , Síncope Vasovagal/fisiopatologia , Vasodilatação/fisiologia , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Teste da Mesa Inclinada , Ultrassonografia
18.
J Interv Card Electrophysiol ; 30(3): 273-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19669397

RESUMO

Atrial tachycardias are relatively common in patients with congenital heart disease. However, complex anomalies involving the heart and the great vessels might compromise the results of the ablation procedure. This report describes a clinical application of the new Cartosound™ module as an adjunctive technology to understand the mechanism of the arrhythmia and to guide successfully the ablation in a complex anatomy. Isthmus-dependent atrial flutter was diagnosed in a patient with complete situs inversus and interruption of the inferior vena cava with azygos continuation. Under these unusual circumstances, Cartosound facilitates interventional navigation within the right atrium and its adjacent structures and minimizes radiation exposure.


Assuntos
Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Veia Ázigos/anormalidades , Ablação por Cateter , Ecocardiografia , Imageamento Tridimensional/métodos , Situs Inversus , Tomografia Computadorizada por Raios X , Veia Cava Inferior/anormalidades , Flutter Atrial/fisiopatologia , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Pessoa de Meia-Idade
19.
J Clin Psychiatry ; 67(11): 1760-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17196057

RESUMO

OBJECTIVE: Major depressive disorder (MDD) is associated with low-grade inflammation, and it is considered a risk factor for coronary artery disease (CAD). CD40 ligand (CD40L) plays an important role in inflammation, platelet activation, and clotting system activation. We investigated soluble CD40L (sCD40L) expression in MDD and assessed whether it may represent a molecular mechanism that links inflammation and a prothrombotic state and whether this condition may be modified by selective serotonin reuptake inhibitor (SSRI) therapy. METHOD: Levels of sCD40L, interleukin-1beta (IL-1beta), interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), soluble P-selectin (sP-selectin), activated factor VII (FVIIa), and prothrombin fragment 1+2 (F1+2) were measured in 46 drug-naïve, first-episode MDD patients without conventional CAD risk factors and in 46 matched healthy controls. Participants were screened between March 2002 and November 2005. Twenty of the 46 MDD patients were then randomly assigned to either sertraline 100 mg/day (N = 10) or citalopram 20 mg/day (N = 10); the aforementioned variables were measured at baseline and after 6 weeks of treatment. RESULTS: Compared with control subjects, MDD patients had higher baseline levels of sCD40L, IL-1beta, IL-6, TNF-alpha, sP-selectin, FVIIa, and F1+2. In the clinical group, sCD40L levels, HAM-D total scores, and proinflammatory markers were strongly intercorrelated. In contrast, there were no significant correlations in the control group. Mood improvement achieved with SSRI therapy was associated with significant reduction in sCD40L, proinflammatory markers, and prothrombotic markers expression. (All p values < .0001.) CONCLUSIONS: This pilot study shows that CD40/ CD40L pathway up-regulation in MDD patients relates increased levels of sCD40L to a prothrombotic state and, preliminarily, indicates that SSRI therapy may significantly reduce sCD40L and CD40L levels associated with proinflammatory and prothrombotic states.


Assuntos
Ligante de CD40/metabolismo , Citalopram/uso terapêutico , Transtorno Depressivo Maior/tratamento farmacológico , Transtorno Depressivo Maior/fisiopatologia , Inflamação/fisiopatologia , Inibidores Seletivos de Recaptação de Serotonina/uso terapêutico , Sertralina/uso terapêutico , Adulto , Biomarcadores/metabolismo , Transtorno Depressivo Maior/complicações , Fator VIIa/metabolismo , Feminino , Humanos , Inflamação/etiologia , Interleucina-1beta/metabolismo , Masculino , Selectina-P/metabolismo , Projetos Piloto , Fator de Necrose Tumoral alfa/metabolismo , Regulação para Cima
20.
Radiol Med ; 107(1-2): 1-10, 2004.
Artigo em Inglês, Italiano | MEDLINE | ID: mdl-15031692

RESUMO

PURPOSE: The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. MATERIALS AND METHODS: An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were "Balanced" Ultrafast Gradient Echo (B-FFE) characterised by a hyper-intense blood signal with multislice multiphase and single slice multiphase acquisitions. RESULTS: In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. CONCLUSIONS: The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.


Assuntos
Cardiopatias/diagnóstico , Valvas Cardíacas/fisiologia , Imageamento por Ressonância Magnética/métodos , Função Ventricular , Adulto , Idoso , Débito Cardíaco , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/fisiopatologia , Diástole , Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/fisiopatologia , Feminino , Cardiopatias/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Cisto Mediastínico/diagnóstico , Cisto Mediastínico/fisiopatologia , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Sensibilidade e Especificidade , Volume Sistólico , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA