Ultrasound Q ; 40(3)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38958999

RESUMO

ABSTRACT: The objective of the study was to use a deep learning model to differentiate between benign and malignant sentinel lymph nodes (SLNs) in patients with breast cancer compared to radiologists' assessments.Seventy-nine women with breast cancer were enrolled and underwent lymphosonography and contrast-enhanced ultrasound (CEUS) examination after subcutaneous injection of ultrasound contrast agent around their tumor to identify SLNs. Google AutoML was used to develop image classification model. Grayscale and CEUS images acquired during the ultrasound examination were uploaded with a data distribution of 80% for training/20% for testing. The performance metric used was area under precision/recall curve (AuPRC). In addition, 3 radiologists assessed SLNs as normal or abnormal based on a clinical established classification. Two-hundred seventeen SLNs were divided in 2 for model development; model 1 included all SLNs and model 2 had an equal number of benign and malignant SLNs. Validation results model 1 AuPRC 0.84 (grayscale)/0.91 (CEUS) and model 2 AuPRC 0.91 (grayscale)/0.87 (CEUS). The comparison between artificial intelligence (AI) and readers' showed statistical significant differences between all models and ultrasound modes; model 1 grayscale AI versus readers, P = 0.047, and model 1 CEUS AI versus readers, P < 0.001. Model 2 r grayscale AI versus readers, P = 0.032, and model 2 CEUS AI versus readers, P = 0.041.The interreader agreement overall result showed κ values of 0.20 for grayscale and 0.17 for CEUS.In conclusion, AutoML showed improved diagnostic performance in balance volume datasets. Radiologist performance was not influenced by the dataset's distribution.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Linfonodo Sentinela , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Linfonodo Sentinela/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Adulto , Radiologistas/estatística & dados numéricos , Ultrassonografia Mamária/métodos , Meios de Contraste , Metástase Linfática/diagnóstico por imagem , Ultrassonografia/métodos , Biópsia de Linfonodo Sentinela/métodos , Mama/diagnóstico por imagem , Reprodutibilidade dos Testes
2.
Artigo em Inglês | MEDLINE | ID: mdl-38750641

RESUMO

BACKGROUND: The liver is the most common organ injured in blunt abdominal trauma and makes up roughly 5% of all trauma admissions. Current treatments are invasive and resource-intensive, which may delay care. We aim to develop and validate a contrast-enhanced ultrasound (CEUS)guided noninvasive tool to treat liver lacerations at the bedside. METHODS: Two 1.8 MHz high-intensity focused ultrasound (HIFU) elements were coupled to a C1-6 diagnostic ultrasound probe and a Logiq E10 scanner (GE HealthCare) utilizing a custom enclosure for co-registered imaging and ablation. A phantom was created from polyacrylamide gel combined with thermochromic ink whose color changes above biological ablative temperatures (60 °C). The HIFU wave was focused approximately 0.5 cm below the surface utilizing a 50% duty cycle generating 11.9 MPa for 20, 30, 40, 50, and 60s. Experiments were repeated on ex vivo chicken livers in a water bath. Finally, the livers of 4 live swine underwent up to 6 CEUS-guided treatments using parameters optimized from in vitro work. RESULTS: Treatment of the phantom between 20-60s, produced ablation sizes from 0.016 to 0.4 cm 3 . The relationship between time and size was exponential (R 2 = 0.992). Ablation areas were also well visualized on with ultrasound imaging. The ex vivo liver ablation size at 20s was 0.37 cm 3 , at 30s was 0.66 cm 3 , and at 100 s was 5.0 cm 3 . For the in-vivo swine experiments, the average ablation area measured 2.0x0.75 cm with a maximum of 3.5x1.5 cm. CEUS was utilized with the contrast agent Definity (Lantheus) for identification of lacerations as well as immediate post operative evaluation of therapy. CONCLUSION: These experiments demonstrate the feasibility of CEUS guided transdermal HIFU ablation and the time-dependent size of ablation. This work warrants future investigations into using ultrasound to detect active bleeding and HIFU to coagulate grade III and IV liver laceration. STUDY TYPE: Therapeutic/care management.

3.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548928

RESUMO

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos de Coortes , Meios de Contraste , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Europa (Continente) , América do Norte , Sensibilidade e Especificidade
4.
Ultrasound Med Biol ; 50(3): 394-398, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38123378

RESUMO

OBJECTIVE: The aim of the work described here was to assess uterine fibroid vascularity using contrast-enhanced ultrasound (CEUS) as compared with magnetic resonance imaging (MRI). METHODS: Forty women diagnosed with symptomatic uterine fibroids scheduled for uterine artery embolization (UAE) were enrolled in this institutional review board-approved study. Before UAE, participants underwent CEUS examination with an Aplio i800 scanner (Canon Medical Systems, Tustin, CA, USA) with curvilinear array (8C1). CEUS was performed using 2.0 mL of the ultrasound contrast agent Lumason (Bracco, Milan, Italy) administered intravenously. Digital CEUS clips were acquired and randomized offline, and fibroids were characterized as hyper- or hypovascular. MRI was used as reference standard for fibroid vascularity and compared with CEUS. Results were analyzed using McNemar's test. RESULTS: Forty participants were enrolled in the trial. One patient did not proceed with the UAE procedure and one patient refused pre-procedure MRI because of claustrophobia. Therefore, 38 participants underwent CEUS and MRI examinations before UAE. Hypervascular fibroids were seen on MRI and CEUS in 24 and 26 participants, respectively. Hypovascular fibroids were seen with MRI and CEUS in 14 and 12 participants, respectively. Fibroids characterized as hypovascular in two participants by MRI were characterized as hypervascular by CEUS. CEUS and MRI findings were similar in 36 of 38 participants, corresponding to an accuracy of 95% (p = 0.62). CONCLUSION: Contrast-enhanced ultrasound can accurately assess uterine fibroid vascularity, serving as a potential alternative to MRI in determination of the vascularity of uterine fibroids.


Assuntos
Leiomioma , Neoplasias Uterinas , Feminino , Humanos , Leiomioma/diagnóstico por imagem , Leiomioma/irrigação sanguínea , Imageamento por Ressonância Magnética , Resultado do Tratamento , Ultrassonografia , Neoplasias Uterinas/irrigação sanguínea
5.
Endosc Ultrasound ; 12(4): 362-368, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795347

RESUMO

Objectives: The objective of this pilot study was to compare the performance of contrast-enhanced EUS (CE-EUS)-guided fine-needle aspiration (FNA) with EUS-FNA for lymph node (LN) staging in esophageal cancer. Methods: Thirty-seven subjects with esophageal cancer undergoing EUS staging were enrolled, and 30 completed this institutional review board-approved study. A Prosound F75 US system (Hitachi Medical Systems, Tokyo, Japan) with harmonic contrast imaging software and GF-UCT180 curvilinear endoscope (Olympus, Tokyo, Japan) was utilized. All LNs identified by standard EUS were first noted. Sonazoid (dose: 1 mL; GE Healthcare, Oslo, Norway) was administered peritumorally, and all enhanced LNs were recorded. Fine-needle aspiration was performed on LNs considered suspicious by EUS alone, as well as LNs enhanced on CE-EUS. Performance of each modality was compared using FNA cytology as reference standard. Results: A total of 132 LNs were detected with EUS, of which 59 showed enhancement on CE-EUS. Fifty-three LNs underwent FNA, and 22 LNs were determined to be malignant. Among the latter, 10 were considered suspicious by EUS, whereas the other 12 LNs underwent FNA only because of CE-EUS enhancement. Contrast-enhanced EUS showed enhancement in 19 of the 22 malignant LNs. The rate of metastatic node identification from EUS was 45% (10/22), and it was 86% (19/22; P = 0.008) for CE-EUS. Eight subjects (8/30 [27% of study total]) had nodal status upgraded by the addition of CE-EUS, which influenced LN staging and clinical management. Conclusions: Fine-needle aspiration of LNs identified by CE-EUS may increase metastasis positive rate by ruling out LNs not associated with the tumor drainage pattern. In addition, CE-EUS seems to identify more metastatic LNs that would not be biopsied under the standard EUS criteria.

6.
Radiology ; 309(1): e230727, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37847138

RESUMO

Background Contrast-enhanced (CE) US has been studied for use in the detection of residual viable hepatocellular carcinoma (HCC) after locoregional therapy, but multicenter data are lacking. Purpose To compare two-dimensional (2D) and three-dimensional (3D) CE US diagnostic performance with that of CE MRI or CT, the current clinical standard, in the detection of residual viable HCC after transarterial chemoembolization (TACE) in a prospective multicenter trial. Materials and Methods Participants aged at least 21 years with US-visible HCC scheduled for TACE were consecutively enrolled at one of three participating academic medical centers from May 2016 to March 2022. Each underwent baseline 2D and 3D CE US before TACE, 2D and 3D CE US 1-2 weeks and/or 4-6 weeks after TACE, and CE MRI or CT 4-6 weeks after TACE. CE US and CE MRI or CT were evaluated by three fellowship-trained radiologists for the presence or absence of viable tumors and were compared with reference standards of pathology (18%), angiography on re-treatment after identification of residual disease at 1-2-month follow-up imaging (31%), 4-8-month CE MRI or CT (42%), or short-term (approximately 1-2 months) CE MRI or CT if clinically decompensated and estimated viability was greater than 50% at imaging (9%). Diagnostic performance criteria, including sensitivity and specificity, were obtained for each modality and time point with generalized estimating equation analysis. Results A total of 132 participants were included (mean age, 64 years ± 7 [SD], 87 male). Sensitivity of 2D CE US 4-6 weeks after TACE was 91% (95% CI: 84, 95), which was higher than that of CE MRI or CT (68%; 95% CI: 58, 76; P < .001). Sensitivity of 3D CE US 4-6 weeks after TACE was 89% (95% CI: 81, 94), which was higher than that of CE MRI or CT (P < .001), with no evidence of a difference from 2D CE US (P = .22). CE MRI or CT had 85% (95% CI: 76, 91) specificity, higher than that of 4-6-week 2D and 3D CE US (70% [95% CI: 56, 80] and 67% [95% CI: 53, 78], respectively; P = .046 and P = .023, respectively). No evidence of differences in any diagnostic criteria were observed between 1-2-week and 4-6-week 2D CE US (P > .21). Conclusion The 2D and 3D CE US examinations 4-6 weeks after TACE revealed higher sensitivity in the detection of residual HCC than CE MRI or CT, albeit with lower specificity. Importantly, CE US performance was independent of follow-up time. Clinical trial registration no. NCT02764801 © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem , Adulto
7.
Acad Radiol ; 30 Suppl 2: S211-S219, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37330354

RESUMO

RATIONALE AND OBJECTIVES: To monitor fibroid microvascularity using contrast-enhanced ultrasound (CEUS) and a new high-sensitive Doppler mode (SMI) for assessment of uterine artery embolization (UAE) outcomes. MATERIALS AND METHODS: Forty women with symptomatic uterine fibroids scheduled for UAE were enrolled in this Institutional Review Board-approved study. Subjects underwent three examinations (day 0, 15, and 90 post-UAE) with Color Doppler (CDI), power Doppler (PDI), color and monochrome SMI (cSMI and mSMI), and CEUS imaging of the fibroids. Clips were assessed by two radiologists classifying fibroids based on their vascularity. Fibroid fractional vascularity (FV; % of enhanced pixels within the fibroid) and flow intensity (as mean brightness level of the enhanced pixels) were quantified. Results were analyzed using repeated measures ANOVA and nonparametric Wilcoxon sign rank tests. Inter-reader agreement was assessed with κ-values. RESULTS: There was overall agreement between readers for all imaging modalities and examination times (P = .25; κ = 0.70). The FV analysis showed statistically significant differences between CEUS and the Doppler imaging modes (CDI, PDI, cSMI, and mSMI) for the three examination times were compared (P < .0001). The comparison using CDI, PDI, and cSMI showed no statistically significant difference (P = .53). The flow intensity analysis comparison between the Doppler imaging modes (CDI, PDI, cSMI and mSMI) and examination times showed statistically significant differences between all the Doppler imaging modalities (P = .02), except for the 90days post-UAE (P = .34). When the comparison was made for CDI, PDI, and cSMI there was no statistically significant differences (P < .47). CONCLUSION: CEUS and SMI can accurately evaluate fibroid microvascularity, and therefore, can be a noninvasive and accurate method for monitoring outcomes following UAE treatment.


Assuntos
Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Humanos , Feminino , Ultrassonografia , Ultrassonografia Doppler/métodos , Leiomioma/diagnóstico por imagem , Leiomioma/terapia , Neoplasias Uterinas/diagnóstico por imagem , Neoplasias Uterinas/terapia , Resultado do Tratamento
8.
J Breast Cancer ; 26(3): 286-291, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37272244

RESUMO

Approximately 15%-25% of breast lymphatic drainage passes through the internal thoracic (internal mammary) lymphatic system, draining the inner quadrants of the breast. This study aimed to use lymphosonography to identify sentinel lymph nodes (SLNs) in the axillary and internal thoracic lymphatic systems in patients with breast cancer. Seventy-nine patients received subcutaneous ultrasound contrast agent injections around the tumor. Lymphosonography was used to identify SLNs. In 14 of the 79 patients (17.7%), the tumor was located in the inner quadrant of the breast. Lymphosonography identified 217 SLNs in 79 patients, averaging 2.7 SLNs per patient. The 217 identified SLNs in the 79 patients were located in the axillary lymphatic system; none were located in the internal thoracic (internal mammary) lymphatic system, although it was expected in two to four patients (i.e., 4-11 SLNs). These results implied that SLNs associated with breast cancer are predominantly located in the axillary lymphatic system.

9.
Pharmaceutics ; 15(4)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37111787

RESUMO

Tumor hypoxia (oxygen deficiency) is a major contributor to radiotherapy resistance. Ultrasound-sensitive microbubbles containing oxygen have been explored as a mechanism for overcoming tumor hypoxia locally prior to radiotherapy. Previously, our group demonstrated the ability to encapsulate and deliver a pharmacological inhibitor of tumor mitochondrial respiration (lonidamine (LND)), which resulted in ultrasound-sensitive microbubbles loaded with O2 and LND providing prolonged oxygenation relative to oxygenated microbubbles alone. This follow-up study aimed to evaluate the therapeutic response to radiation following the administration of oxygen microbubbles combined with tumor mitochondrial respiration inhibitors in a head and neck squamous cell carcinoma (HNSCC) tumor model. The influences of different radiation dose rates and treatment combinations were also explored. The results demonstrated that the co-delivery of O2 and LND successfully sensitized HNSCC tumors to radiation, and this was also enhanced with oral metformin, significantly slowing tumor growth relative to unsensitized controls (p < 0.01). Microbubble sensitization was also shown to improve overall animal survival. Importantly, effects were found to be radiation dose-rate-dependent, reflecting the transient nature of tumor oxygenation.

10.
J Ultrasound Med ; 42(8): 1747-1756, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36807314

RESUMO

OBJECTIVES: Current diagnosis of nonalcoholic fatty liver disease (NAFLD) relies on biopsy or MR-based fat quantification. This prospective study explored the use of ultrasound with artificial intelligence for the detection of NAFLD. METHODS: One hundred and twenty subjects with clinical suspicion of NAFLD and 10 healthy volunteers consented to participate in this institutional review board-approved study. Subjects were categorized as NAFLD and non-NAFLD according to MR proton density fat fraction (PDFF) findings. Ultrasound images from 10 different locations in the right and left hepatic lobes were collected following a standard protocol. MRI-based liver fat quantification was used as the reference standard with >6.4% indicative of NAFLD. A supervised machine learning model was developed for assessment of NAFLD. To validate model performance, a balanced testing dataset of 24 subjects was used. Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy with 95% confidence interval were calculated. RESULTS: A total of 1119 images from 106 participants was used for model development. The internal evaluation achieved an average precision of 0.941, recall of 88.2%, and precision of 89.0%. In the testing set AutoML achieved a sensitivity of 72.2% (63.1%-80.1%), specificity of 94.6% (88.7%-98.0%), positive predictive value (PPV) of 93.1% (86.0%-96.7%), negative predictive value of 77.3% (71.6%-82.1%), and accuracy of 83.4% (77.9%-88.0%). The average agreement for an individual subject was 92%. CONCLUSIONS: An ultrasound-based machine learning model for identification of NAFLD showed high specificity and PPV in this prospective trial. This approach may in the future be used as an inexpensive and noninvasive screening tool for identifying NAFLD in high-risk patients.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Inteligência Artificial , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Aprendizado de Máquina
11.
JACC Cardiovasc Imaging ; 16(2): 224-235, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36648035

RESUMO

BACKGROUND: Noninvasive and accurate assessment of intracardiac pressures has remained an elusive goal of noninvasive cardiac imaging. OBJECTIVES: The purpose of this study was to investigate if errors in intracardiac pressures obtained noninvasively using contrast microbubbles and the subharmonic-aided pressure estimation (SHAPE) technique are <5 mm Hg. METHODS: In a nonrandomized institutional review board-approved clinical trial (NCT03243942), patients scheduled for a left-sided and/or right-sided heart catheterization procedure and providing written informed consent were included. A standard-of-care catheterization procedure was performed advancing clinically used pressure catheters into the left and/or right ventricles and/or the aorta. After pressure catheter placement, patients received an infusion of Definity microbubbles (n = 56; 2 vials diluted in 50 mL of saline; infusion rate: 4-10 mL/min) (Lantheus Medical Imaging). Then SHAPE data was acquired using a validated interface developed on a SonixTablet scanner (BK Medical Systems) synchronously with the pressure catheter data. A conversion factor (mm Hg/dB) was derived from SHAPE data and measurements with a SphygmoCor XCEL PWA device (ATCOR Medical) and was combined with SHAPE data from the left and/or the right ventricles to obtain clinically relevant systolic and diastolic ventricular pressures. RESULTS: The mean value of absolute errors for left ventricular minimum and end diastolic pressures were 2.9 ± 2.0 and 1.7 ± 1.2 mm Hg (n = 26), respectively, and for right ventricular systolic pressures was 2.2 ± 1.5 mm Hg (n = 11). Two adverse events occurred during Definity infusion; both were resolved. CONCLUSIONS: These results indicate that the SHAPE technique with Definity microbubbles is encouragingly efficacious for obtaining intracardiac pressures noninvasively and accurately. (Noninvasive, Subharmonic Intra-Cardiac Pressure Measurement; NCT03243942).


Assuntos
Meios de Contraste , Microbolhas , Humanos , Ultrassonografia/métodos , Valor Preditivo dos Testes , Cateterismo Cardíaco/efeitos adversos
12.
J Ultrasound Med ; 42(7): 1509-1517, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36591785

RESUMO

OBJECTIVES: This study evaluated the efficacy of lymphosonography in the identification of sentinel lymph nodes (SLNs) in post neoadjuvant chemotherapy patients with breast cancer scheduled to undergo surgical excision. METHODS: Seventy-nine subjects scheduled for breast cancer surgery with SLN excision completed this IRB-approved study, out of which 18 (23%) underwent neoadjuvant chemotherapy before surgery. Subjects underwent percutaneous Sonazoid (GE Healthcare) injections around the tumor area for a total of 1.0 mL. Lymphosonography was performed using CPS on an S3000 HELX scanner (Siemens Healthineers) with a linear probe. Subjects received blue dye and radioactive tracer as part of their standard of care. Excised SLNs were classified as positive or negative for the presence of blue dye, radioactive tracer and Sonazoid. The results were compared between methods and pathology findings. RESULTS: Seventy-two SLNs were surgically excised from 18 subjects, 29 were positive for blue dye, 63 were positive for radioactive tracer and 57 were positive for Sonazoid. Comparison with blue dye showed that both radioactive tracer and lymphosonography achieved an accuracy of 53% (P > .50). Comparison with radioactive tracer showed that blue dye had an accuracy of 53%, while lymphosonography achieved an accuracy of 67% (P < .01). Of the 72 SLNs, 15 were determined malignant by pathology; the detection rate was 47% for blue dye (7/15), 67% for radioactive tracer (10/15) and 100% for lymphosonography (15/15) (P < .001). CONCLUSIONS: Lymphosonography achieved similar accuracy as radioactive tracer and higher accuracy than blue dye for identifying SLNs. The 15 SLNs positive for malignancy were all identified by lymphosonography.


Assuntos
Neoplasias da Mama , Linfadenopatia , Linfonodo Sentinela , Humanos , Feminino , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Biópsia de Linfonodo Sentinela/métodos , Linfonodos/patologia , Excisão de Linfonodo , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Terapia Neoadjuvante , Traçadores Radioativos , Linfadenopatia/patologia
13.
Ultrasound Med Biol ; 49(2): 616-625, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36446688

RESUMO

The objective of the work described here was to evaluate the efficacy of lymphosonography in identifying sentinel lymph nodes (SLNs) in patients with breast cancer undergoing surgical excision. Of the 86 individuals enrolled, 79 completed this institutional review board-approved study. Participants received subcutaneous 1.0-mL injections of ultrasound contrast agent (UCA) around the tumor. An ultrasound scanner with contrast-enhanced ultrasound (CEUS) capabilities was used to identify SLNs. Participants were administered with blue dye and radioactive tracer to guide SLN excision as standard-of-care. Excised SLNs were classified as positive or negative for the presence of blue dye, radioactive tracer and UCA, and sent for pathology. Two hundred fifty-two SLNs were excised; 158 were positive for blue dye, 222 were positive for radioactive tracer and 223 were positive for UCA. Comparison with blue dye revealed accuracies of 96.2% for radioactive tracer and 99.4% for lymphosonography (p > 0.15). Relative to radioactive tracer, blue dye had an accuracy of 68.5%, and lymphosonography achieved 86.5% (p < 0.0001). Of 252 SLNs excised, 34 were determined to be malignant by pathology; 18 were positive for blue dye (detection rate = 53%), 23 for radioactive tracer (detection rate = 68%) and 34 for UCA (detection rate = 100%) (p < 0.0001). Lymphosonography was similar in accuracy to radioactive tracer and higher in accuracy than blue dye in identifying SLNs. All 34 malignant SLNs were identified by lymphosonography.


Assuntos
Neoplasias da Mama , Linfadenopatia , Linfonodo Sentinela , Humanos , Feminino , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Neoplasias da Mama/patologia , Linfonodos/patologia , Biópsia de Linfonodo Sentinela , Traçadores Radioativos , Meios de Contraste
14.
Eur Urol Focus ; 9(2): 336-344, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36319560

RESUMO

BACKGROUND: Management of complex renal cysts is guided by the Bosniak classification system, which may be inadequate for risk stratification of patients for intervention. Fractional tumor vascularity (FV) calculated from volumetric contrast-enhanced ultrasound (CEUS) images may provide additional useful information. OBJECTIVE: To evaluate CEUS and FV calculation for risk stratification of patients with complex renal cysts. DESIGN, SETTING, AND PARTICIPANTS: This was a pilot prospective study with institutional review board approval involving patients undergoing surgery for Bosniak IIF-IV complex renal cysts. CEUS was performed preoperatively on the day of surgery with two-dimensional (2D) and three-dimensional (3D) imaging and sulfur hexafluoride lipid-type A microspheres as the ultrasound contrast agent. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: A custom MATLAB program was used to select regions of interest on CEUS scans. FV was calculated according to FV = 1 - (total nonenhancing area/total lesion area). We assessed the ability of 2D- and 3D-derived percentage FV (2DFV%, and 3DFV%) and Bosniak classification schemes (pre-2019 [P2019B] and post-2019 [B2019]) to predict malignancy, aggressive histology, and upstaging on surgical pathology. Performance was assessed as area under the receiver operating characteristic curve (AUC). RESULTS AND LIMITATIONS: Twenty eligible patients were included in final analysis, of whom 85% (n = 17) had Bosniak IV cysts and 85% (n = 17) had malignant disease on final pathology. Four (24%) of the malignant lesions were International Society of Urological Pathology grade 3-4. The AUC for predicting malignancy was 0.980, 0.824, 0.863, and 0.824 with P2019B, B2019, 2DFV%, and 3DFV%, respectively. When the Bosniak classification was combined with FV%, three models had an AUC of 1, while the combined 2DFV% + B2019 model had AUC of 0.980. CONCLUSIONS: FV is a novel metric for evaluating complex cystic renal masses and enhances the ability of the Bosniak classification system to predict malignancy. This metric may serve as an adjunct in risk stratification for surgical intervention. Further prospective evaluation is warranted. PATIENT SUMMARY: Cysts in the kidney are currently classified using a scheme called the Bosniak system. We assessed measurement of the percentage of vascular tissue (called fractional vascularity) in cysts on a special type of ultrasound scan. This promising test adds information when combined with the Bosniak system and can help in guiding appropriate treatment.


Assuntos
Cistos , Doenças Renais Císticas , Neoplasias Renais , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Doenças Renais Císticas/diagnóstico por imagem , Doenças Renais Císticas/cirurgia , Cistos/diagnóstico por imagem , Ultrassonografia/métodos , Meios de Contraste
15.
World J Urol ; 41(3): 673-678, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35969244

RESUMO

PURPOSE: Ultrasound's versatility and ease of use has expanded its application in many clinical settings. Technological advancements with contrast-enhanced ultrasound (CEUS) have allowed high quality imaging similar to CT or MRI with lower risk of contrast toxicity and radiation exposure. In this review article we examine the development of CEUS and its vast applications in the field of urology. METHODS: A PubMed literature search was performed using keywords: contrast enhanced ultrasound, prostate cancer, renal cancer, and multiparametric ultrasound. RESULTS: The development of CEUS has improved transrectal ultrasound imaging with increased detection of prostate cancer (PCa). Further enhancements of CEUS such as subharmonic imaging (SHI), flash replenishment imaging (FRI) and contrast ultrasound dispersion imaging (CUDI) allow improved PCa diagnosis. CEUS has also emerged as an important tool in characterizing suspicious renal mass without compromising renal function with contrast imaging. CONCLUSION: CEUS has modernized imaging and diagnosis of prostate and renal cancer. Future advancements and utilization of CEUS will allow its expansion into other urological subspecialties.


Assuntos
Neoplasias Renais , Neoplasias da Próstata , Urologia , Masculino , Humanos , Meios de Contraste , Ultrassonografia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias Renais/diagnóstico por imagem
16.
Transl Androl Urol ; 11(8): 1210-1221, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36092843

RESUMO

Background: Penile prosthesis (PP) is a gold standard for treatment of erectile dysfunction given its reliability and efficacy. Infection remains the most feared complication of prosthetic surgery, which usually results in device removal, and places a significant economic burden on the healthcare system. While biofilms have shown to support the persistence of microorganisms, the degree by which this matrix is truly pathogenic remains unknown given its high prevalence even in asymptomatic patients. We aim to review and summarize the current literature pertaining to biofilm formation in the setting of PP surgeries in clinically infected and non-infected cases. Methods: Searches were performed in the MEDLINE online database through PubMed using a combination of keywords "penile prosthetic" OR "penile prosthesis" OR "penile implant" AND "biofilm" OR "revision" OR "removal" OR "infection" OR "explant". Eleven articles met inclusion criteria. There were only three studies that explicitly listed the number of biofilms identified in their cohort, but we also included eight articles that mentioned swabbing and culturing of any bacterial biofilm during revision procedures for both clinically infected and non-infected implants. Results: Infected PP yielded a 11-100% rate of biofilm presence, while non-infected PP yielded a 3-70% rate of biofilm presence. Time to reoperation from initial PP placement were also largely variable, ranging from 2 weeks to over 2 years. Coagulase-negative staphylococcus (i.e., Staphylococcus epidermidis) were the most commonly reported organisms among non-infected implants, however, newer studies have identified a change towards more virulent organisms. Conclusions: Since the advent of PP surgery, diabetes control, revision washout protocols and antibiotic-impregnated devices have led to an overall decrease in biofilm formation and infectious complications. There is an overall paradigm shift in microbial profiles with more virulent organisms, such as Escherichia coli, Pseudomonas aeruginosa, Enterococcus species, and even fungal species beginning to replace the more common coagulase-negative staphylococcal species, especially in clinically infected implants. Additional studies are necessary to define the significance of bacterial presence in biofilms using impactful technologies such as next-generation sequencing. Currently, preliminary and experimental biofilm-control strategies are also underway to further address this clinical issue.

17.
Int J Pharm ; 625: 122072, 2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-35932933

RESUMO

Prior work has shown that microbubble-assisted delivery of oxygen improves tumor oxygenation and radiosensitivity, albeit over a limited duration. Lonidamine (LND) has been investigated because of its ability to stimulate glycolysis, lactate production, inhibit mitochondrial respiration, and inhibit oxygen consumption rates in tumors but suffers from poor bioavailability. The goal of this work was to characterize LND-loaded oxygen microbubbles and assess their ability to oxygenate a human head and neck squamous cell carcinoma (HNSCC) tumor model, while also assessing LND biodistribution. In tumors treated with surfactant-shelled microbubbles with oxygen core (SE61O2) and ultrasound, pO2 levels increased to a peak 19.5 ± 9.7 mmHg, 50 s after injection and returning to baseline after 120 s. In comparison, in tumors treated with SE61O2/LND and ultrasound, pO2 levels showed a peak increase of 29.0 ± 8.3 mmHg, which was achieved 70 s after injection returning to baseline after 300 s (p < 0.001). The co-delivery of O2andLNDvia SE61 also showed an improvement of LND biodistribution in both plasma and tumor tissues (p < 0.001). In summary, ultrasound-sensitive microbubbles loaded with O2 and LND provided prolonged oxygenation relative to oxygenated microbubbles alone, as well as provided an ability to locally deliver LND, making them more appropriate for clinical translation.


Assuntos
Microbolhas , Neoplasias , Humanos , Indazóis , Oxigênio , Distribuição Tecidual
18.
J Urol ; 207(1): 152-160, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34428090

RESUMO

PURPOSE: Urologists will benefit from an imaging modality which can assess intra and extraluminal characteristics of urethral strictures. We conducted a prospective pilot study evaluating the utility of contrast-enhanced ultrasound and shear wave elastography for the evaluation of bulbar urethral stricture disease. MATERIALS AND METHODS: Patients with a single, bulbar urethral stricture were prospectively recruited. Contrast-enhanced ultrasound and shear wave elastography were performed at the time of surgical repair and at 4 months' followup using an Aplio i800 scanner (Canon Medical Systems, Tustin, California) with an i8CX1 transducer. Sulfur hexafluoride lipid-type A microsphere ultrasound contrast (Lumason®, Bracco Imaging, Princeton, New Jersey) was injected retrograde through the urethra. Stiffness of the corpus spongiosum was measured at and adjacent to the stricture site. Stricture lengths based on retrograde urethrogram, grayscale ultrasound and contrast-enhanced ultrasound were correlated with measured intraoperative stricture length. RESULTS: Thirty men were enrolled. Contrast-enhanced ultrasound (R2=0.709) showed the best correlation with intraoperative measured stricture length compared to retrograde urethrogram (R2=0.016) or grayscale ultrasound (R2=0.471). Stiffness of the spongiosum was greater at the site of the stricture (32.6±5.4 vs 27.3±5.8 kPa, p=0.044) and in narrower caliber strictures (p=0.044) but did not differ by stricture length (p=0.182). At followup (4.3±1.1 months) contrast-enhanced ultrasound detected stricture recurrence with 80% sensitivity, 100% specificity, and 93% accuracy compared to cystoscopy. CONCLUSIONS: This pilot study demonstrates the ability of contrast-enhanced ultrasound and shear wave elastography to become safe, accurate, and potentially efficacious modalities for assessing bulbar urethral strictures and spongiofibrosis.


Assuntos
Meios de Contraste , Técnicas de Imagem por Elasticidade , Estreitamento Uretral/diagnóstico por imagem , Adulto , Idoso , Humanos , Masculino , Microesferas , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Ultrassonografia/métodos
19.
J Ultrasound Med ; 41(9): 2365-2371, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34866197

RESUMO

The feasibility of activating phase change contrast agents (PCCA) made from Definity (Lantheus Medical Imaging) using X-rays was investigated. A 10 mL of Definity PCCA (0.1 mL PCCA/mL) were injected into gelatin phantoms and irradiated using doses of 0, 30, 50, and 100 Gy. Size distribution and PCCA activation were measured after irradiation. Definity PCCAs were activated at a threshold of 50 Gy. Changes were visible with microscopy, visual inspection of T-flasks, and ultrasound imaging of gelatin phantoms. Moreover, increasing the radiation dose above 50 Gy appeared to further activate PCCA. These results indicate Definity PCCAs may be useful for ultrasound-based radiation dosimetry.


Assuntos
Meios de Contraste , Gelatina , Humanos , Imagens de Fantasmas , Radiação Ionizante , Ultrassonografia/métodos
20.
J Ultrasound Med ; 41(7): 1667-1675, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34694019

RESUMO

OBJECTIVE: Breast cancer is the most frequent type of cancer among women. This multi-center study assessed the ability of 3D contrast-enhanced ultrasound to characterize suspicious breast lesions using clinical assessments and quantitative parameters. METHODS: Women with suspicious breast lesions scheduled for biopsy were enrolled in this prospective, study. Following 2D grayscale ultrasound and power Doppler imaging (PDI), a contrast agent (Definity; Lantheus) was administrated. Contrast-enhanced 3D harmonic imaging (HI; transmitting/receiving at 5.0/10.0 MHz), as well as 3D subharmonic imaging (SHI; transmitting/receiving at 5.8/2.9 MHz), were performed using a modified Logiq 9 scanner (GE Healthcare). Five radiologists independently scored the imaging modes (including standard-of-care imaging) using a 7-point BIRADS scale as well as lesion vascularity and diagnostic confidence. Parametric volumes were constructed from time-intensity curves for vascular heterogeneity, perfusion, and area under the curve. Diagnostic accuracy was determined relative to pathology using receiver operating characteristic (ROC) and reverse, step-wise logistical regression analyses. The κ-statistic was calculated for inter-reader agreement. RESULTS: Data were successfully acquired in 219 cases and biopsies indicated 164 (75%) benign and 55 (25%) malignant lesions. SHI depicted more anastomoses and vascularity than HI (P < .021), but there were no differences by pathology (P > .27). Ultrasound achieved accuracies of 82 to 85%, which was significantly better than standard-of-care imaging (72%; P < .03). SHI increased diagnostic confidence by 3 to 6% (P < .05), but inter-reader agreements were medium to low (κ < 0.52). The best regression model achieved 97% accuracy by combining clinical reads and parametric SHI. CONCLUSIONS: Combining quantitative 3D SHI parameters and clinical assessments improves the characterization of suspicious breast lesions.


Assuntos
Neoplasias da Mama , Meios de Contraste , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Estudos Prospectivos , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos