Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Lancet Reg Health Eur ; 36: 100787, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38188275

RESUMO

Background: Incisional hernia occurs approximately in 40% of high-risk patients after midline laparotomy. Prophylactic mesh placement has shown promising results, but long-term outcomes are needed. The present study aimed to assess the long-term incisional hernia rates of the previously conducted PRIMA trial with radiological follow-up. Methods: In the PRIMA trial, patients with increased risk of incisional hernia formation (AAA or BMI ≥27 kg/m2) were randomised in a 1:2:2 ratio to primary suture, onlay mesh or sublay mesh closure in three different countries in eleven institutions. Incisional hernia during follow-up was diagnosed by any of: CT, ultrasound and physical examination, or during surgery. Assessors and patients were blinded until 2-year follow-up. Time-to-event analysis according to intention-to-treat principle was performed with the Kaplan-Meier method and Cox proportional hazard models. Trial registration: NCT00761475 (ClinicalTrials.gov). Findings: Between 2009 and 2012, 480 patients were randomized: 107 primary suture, 188 onlay mesh and 185 sublay mesh. Five-year incisional hernia rates were 53.4% (95% CI: 40.4-64.8), 24.7% (95% CI: 12.7-38.8), 29.8% (95% CI: 17.9-42.6), respectively. Compared to primary suture, onlay mesh (HR: 0.390, 95% CI: 0.248-0.614, p < 0.001) and sublay mesh (HR: 0.485, 95% CI: 0.309-0.761, p = 0.002) were associated with a significantly lower risk of incisional hernia development. Interpretation: Prophylactic mesh placement remained effective in reducing incisional hernia occurrence after midline laparotomy in high-risk patients during long-term follow-up. Hernia rates in the primary suture group were higher than previously anticipated. Funding: B. Braun.

3.
Br J Surg ; 109(12): 1239-1250, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36026550

RESUMO

BACKGROUND: Incisional hernia is a frequent complication of abdominal wall incision. Surgical technique is an important risk factor for the development of incisional hernia. The aim of these updated guidelines was to provide recommendations to decrease the incidence of incisional hernia. METHODS: A systematic literature search of MEDLINE, Embase, and Cochrane CENTRAL was performed on 22 January 2022. The Scottish Intercollegiate Guidelines Network instrument was used to evaluate systematic reviews and meta-analyses, RCTs, and cohort studies. The GRADE approach (Grading of Recommendations, Assessment, Development and Evaluation) was used to appraise the certainty of the evidence. The guidelines group consisted of surgical specialists, a biomedical information specialist, certified guideline methodologist, and patient representative. RESULTS: Thirty-nine papers were included covering seven key questions, and weak recommendations were made for all of these. Laparoscopic surgery and non-midline incisions are suggested to be preferred when safe and feasible. In laparoscopic surgery, suturing the fascial defect of trocar sites of 10 mm and larger is advised, especially after single-incision laparoscopic surgery and at the umbilicus. For closure of an elective midline laparotomy, a continuous small-bites suturing technique with a slowly absorbable suture is suggested. Prophylactic mesh augmentation after elective midline laparotomy can be considered to reduce the risk of incisional hernia; a permanent synthetic mesh in either the onlay or retromuscular position is advised. CONCLUSION: These updated guidelines may help surgeons in selecting the optimal approach and location of abdominal wall incisions.


An incisional hernia results from a weakness of the abdominal wall muscles that allows fat from the inside or organs to bulge out. These hernias are quite common after abdominal surgery at the site of a previous incision. There is research that discusses different ways to close an incision and this may relate to the chance of hernia formation. The aim of this study was to review the latest research and to provide a guide for surgeons on how best to close incisions to decrease hernia rates. When possible, surgery through small incisions may decrease the risk of hernia formation. If small incisions are used, it may be better if they are placed away from areas that are already weak (such as the belly button). If the incision is larger than 1 cm, it should be closed with a deep muscle-fascia suture in addition to skin sutures. If there is a large incision in the middle of the abdomen, the muscle should be sutured using small stitches that are close together and a slowly absorbable suture should be used. For patients who are at higher risk of developing hernias, when closing the incision, the muscle layer can be strengthened by using a piece of (synthetic) mesh. There is no good research available on recovery after surgery and no clear guides on activity level or whether a binder will help prevent hernia formation.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Incisional , Humanos , Parede Abdominal/cirurgia , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos , Hérnia Incisional/epidemiologia , Hérnia Incisional/prevenção & controle , Hérnia Incisional/cirurgia , Laparotomia , Técnicas de Sutura , Guias de Prática Clínica como Assunto
4.
Br J Surg ; 109(9): 839-845, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35707932

RESUMO

BACKGROUND: Incisional hernia remains a frequent problem after midline laparotomy. This study compared a short stitch to standard loop closure using an ultra-long-term absorbent elastic suture material. METHODS: A prospective, multicentre, parallel-group, double-blind, randomized, controlled superiority trial was designed for the elective setting. Adult patients were randomly assigned by computer-generated sequence to fascial closure using a short stitch (5 to 8 mm every 5 mm, USP 2-0, single thread HR 26 mm needle) or long stitch technique (10 mm every 10 mm, USP 1, double loop, HR 48 mm needle) with a poly-4-hydroxybutyrate-based suture material (Monomax®). Incisional hernia assessed by ultrasound 1 year after surgery was the primary outcome. RESULTS: The trial randomized 425 patients to short (n = 215) or long stitch technique (n = 210) of whom 414 (97.4 per cent) completed 1 year of follow-up. In the short stitch group, the fascia was closed with more stitches (46 (12 s.d.) versus 25 (7 s.d.); P < 0.001) and higher suture-to-wound length ratio (5.3 (2.2 s.d.) versus 4.0 (1.3 s.d.); P < 0.001). At 1 year, seven of 210 (3.3 per cent) patients in the short and 13 of 204 (6.4 per cent) patients in the long stitch group developed incisional hernia (odds ratio 1.97, 95 per cent confidence interval 0.77 to 5.05; P = 0.173). CONCLUSION: The 1-year incisional hernia development was relatively low with clinical but not statistical difference between short and long stitches. Registration number: NCT01965249 (http://www.clinicaltrials.gov).


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Incisional , Adulto , Humanos , Hérnia Incisional/cirurgia , Laparotomia/métodos , Estudos Prospectivos , Técnicas de Sutura , Suturas
6.
J Abdom Wall Surg ; 1: 10962, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38314158

RESUMO

Introduction: The risk of developing an incisional hernia after primary elective median laparotomy is reported in the literature as being between 5 and 20 percent. The basic of an optimal outcome after midline incision is the appropriate closure technique with or without a prophylactic mesh. The objective of this paper is to critically examine the various closure techniques and, in particular, to present a detailed comparison of the long stitch and short stitch techniques. Method: Based on the available literature, the characteristics of the different closure techniques are described in detail, advantages and disadvantages are compared, and the current status of a practicable recommendation is discussed. Special attention is paid to the criteria of the short stitch technique, such as the suture to incision length ratio, number of stitches and distances, as well as suture material. Results: For elective midline closures, the use of a continuous closure using a slowly absorbable suture material in the small-bites technique with suture to wound ratio of at least 5:1 result in significantly lower risk of complications such as bursting abdomen and less incisional hernia rates compared to the large-bites technique. Conclusion: Based on the present evidence in midline closure after elective laparotomy the small bites technique can be recommended to significantly reduce the rate of incisional hernia.

9.
Front Surg ; 8: 641581, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34250002

RESUMO

Anatomical education and surgical training with cadavers are usually considered an appropriate method of teaching, above all for all surgeons at various levels. Indeed, in such a way they put into practice and exercise a procedure before performing it live, reducing the learning curve in a safe environment and the risks for the patients. Really, up to now it is not clear if the nonuse of the cadavers for anatomical education and surgical training can have also forensic implications. A substantial literature research was used for this review, based on PubMed and Web of Science database. From this review, it is clear that the cadaveric training could be considered mandatory, both for surgeons and for medical students, leading to a series of questions with forensic implications. Indeed, there are many evidences that a cadaver lab can improve the learning curve of a surgeon, above all in the first part of the curve, in which frequent and severe complications are possible. Consequently, a medical responsibility for residents and surgeons which perform a procedure without adequate training could be advised, but also for hospital, that has to guarantee a sufficient training for its surgeons and other specialists through cadaver labs. Surely, this type of training could help to improve the practical skills of surgeons working in small hospitals, where some procedures are rare. Cadaver studies can permit a better evaluation of safety and efficacy of new surgical devices by surgeons, avoiding using patients as ≪guinea pigs≫. Indeed, a legal responsibility for a surgeon and other specialists could exist in the use of a new device without an apparent regulatory oversight. For a good medical practice, the surgeons should communicate to the patient the unsure procedural risks, making sure the patients' full understanding about the novelty of the procedure and that they have used this technique on few, if any, patients before. Cadaver training could represent a shortcut in the standard training process, increasing both the surgeon learning curve and patient confidence. Forensic clinical anatomy can supervise and support all these aspects of the formation and of the use of cadaver training.

10.
Int J Surg ; 83: 31-36, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32931978

RESUMO

BACKGROUND: Resorbable biomaterials have been developed to reduce the amount of foreign material remaining in the body after hernia repair over the long-term. However, on the short-term, these resorbable materials should render acceptable results with regard to complications, infections, and reoperations to be considered for repair. Additionally, the rate of resorption should not be any faster than collagen deposition and maturation; leading to early hernia recurrence. Therefore, the objective of this study was to collect data on the short-term performance of a new resorbable biosynthetic mesh (Phasix™) in patients requiring Ventral Hernia Working Group (VHWG) Grade 3 midline incisional hernia repair. MATERIALS AND METHODS: A prospective, multi-center, single-arm trial was conducted at surgical departments in 15 hospitals across Europe. Patients aged ≥18, scheduled to undergo elective Ventral Hernia Working Group Grade 3 hernia repair of a hernia larger than 10 cm2 were included. Hernia repair was performed with Phasix™ Mesh in sublay position when achievable. The primary outcome was the rate of surgical site occurrence (SSO), including infections, that required intervention until 3 months after repair. RESULTS: In total, 84 patients were treated with Phasix™ Mesh. Twenty-two patients (26.2%) developed 32 surgical site occurrences. These included 11 surgical site infections, 9 wound dehiscences, 7 seromas, 2 hematomas, 2 skin necroses, and 1 fistula. No significant differences in surgical site occurrence development were found between groups repaired with or without component separation technique, and between clean-contaminated or contaminated wound sites. At three months, there were no hernia recurrences. CONCLUSION: Phasix™ Mesh demonstrated acceptable postoperative surgical site occurrence rates in patients with a Ventral Hernia Working Group Grade 3 hernia. Longer follow-up is needed to evaluate the recurrence rate and the effects on quality of life. This study is ongoing through 24 months of follow-up.


Assuntos
Hérnia Ventral/cirurgia , Herniorrafia/métodos , Hérnia Incisional/cirurgia , Telas Cirúrgicas , Adulto , Idoso , Materiais Biocompatíveis , Feminino , Herniorrafia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Seroma/epidemiologia , Telas Cirúrgicas/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA