Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
ESC Heart Fail ; 10(3): 1847-1859, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907649

RESUMO

AIMS: Intravenous iron therapy (IVIT) is known to improve functional status in chronic heart failure (CHF) patients. The exact mechanism is not completely understood. We correlated magnetic resonance imaging (MRI) patterns of T2* iron signal in various organs to systemic iron and exercise capacity (EC) in CHF before and after IVIT. METHODS AND RESULTS: We prospectively analysed 24 patients with systolic CHF for T2* MRI pattern of the left ventricle (LV), small and large intestines, spleen, liver, skeletal muscle, and brain for iron. In 12 patients with iron deficiency (ID), we restored iron deficit by IVIT using ferric carboxymaltose. The effects after 3 months were analysed by spiroergometry and MRI. Patients with vs. without ID showed lower blood ferritin, haemoglobin (76 ± 63 vs. 196 ± 82 µg/L and 12.3 ± 1.1 vs. 14.2 ± 1.1 g/dL, all P < 0.002), and in trend a lower transferrin saturation (TSAT) (19.1 [13.1; 28.2] vs. 25.1 [21.3; 29.1] %, P = 0.05). Spleen and liver iron was lower as expressed by higher T2* value (71.8 [66.4; 93.1] vs. 36.9 [32.9; 51.7] ms, P < 0.002 and 33.5 ± 5.9 vs. 28.8 ± 3.9 ms, and P < 0.03). There was a strong trend for a lower cardiac septal iron content in ID (40.6 [33.0; 57.3] vs. 33.7 [31.3; 40.2] ms, P = 0.07). After IVIT, ferritin, TSAT, and haemoglobin increased (54 [30; 104] vs. 235 [185; 339] µg/L, 19.1 [13.1; 28.2] vs. 25.0 [21.0; 33.7] %, 12.3 ± 1.1 vs. 13.3 ± 1.3 g/L, all P < 0.04). Peak VO2 improved (18.2 ± 4.2 vs. 20.9 ± 3.8 mL/min/kg-1 , P = 0.05). Higher peak VO2 at anaerobic threshold was associated with higher blood ferritin, reflecting higher metabolic exercise capacity after therapy (r = 0.9, P = 0.0009). Increase in EC was associated with haemoglobin increase (r = 0.7, P = 0.034). LV iron increased by 25.4% (48.5 [36.2; 64.8] vs. 36.2 [32.9; 41.9] ms, P < 0.04). Spleen and liver iron increased by 46.4 and 18.2%, respectively (71.8 [66.4; 93.1] vs. 38.5 [22.4; 76.9] ms, P < 0.04 and 33.5 ± 5.9 vs. 27.4 ± 8.6 ms, P < 0.007). Iron in skeletal muscle, brain, intestine, and bone marrow remained unchanged (29.6 [28.6; 31.2] vs. 30.4 [29.7; 30.7] ms, P = 0.7, 81.0 ± 6.3 vs. 82.9 ± 9.9 ms, P = 0.6, 34.3 ± 21.4 vs. 25.3 ± 14.1 ms, P = 0.2, 9.4 [7.5; 21.8] vs. 10.3 [6.7; 15.7] ms, P = 0.5 and 9.8 ± 1.5 vs. 13.7 ± 8.9 ms, P = 0.1). CONCLUSIONS: CHF patients with ID showed lower spleen, liver, and in trend lower cardiac septal iron. After IVIT, iron signal of the left ventricle as well as spleen and liver increased. Improvement in EC was associated with increase in haemoglobin after IVIT. In ID, liver, spleen, and brain but not heart iron were associated with markers of systemic ID.


Assuntos
Insuficiência Cardíaca Sistólica , Deficiências de Ferro , Humanos , Ferro , Ferritinas , Imageamento por Ressonância Magnética , Hemoglobinas
2.
Rofo ; 194(3): 266-271, 2022 Mar.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34794188

RESUMO

BACKGROUND: Hemorrhoids are a widespread disease. Treatment options range from dietary measures to open surgery. A novel treatment approach is the embolization of the hemorrhoidal arteries. METHOD: A review was performed based on a selective literature search in PubMed representing the current state of research. The keywords "hemorrhoid" and "embolization" and "emborrhoid" were used. In addition, technical details of the hemorrhoidal embolization procedure are explained. RESULTS AND CONCLUSION: Embolization of hemorrhoidal arteries is a safe treatment, which allows efficient symptom control even in patients with contraindications for open surgery. KEY POINTS: · Embolization of hemorrhoidal arteries is a new approach to the treatment of hemorrhoids.. · Embolization of hemorrhoidal arteries is feasible in patients with contraindications for open surgery such as hypercoaguable states and contraindications for general anesthesia.. · The endovascular approach causes no rectal and anal trauma and associated complications can be avoided.. · The treatment of bleeding hemorrhoids seems to be particularly effective.. · No ischemic complications have been reported so far when coils as well as particles were used.. CITATION FORMAT: · Feyen L, Freyhardt P, Schott P et al. Hämorrhoidenembolisation: Eine neue minimalinvasive endovaskuläre Therapieoption bei Hämorrhoidalleiden. Fortschr Röntgenstr 2022; 194: 266 - 271.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Hemorroidas , Artérias/diagnóstico por imagem , Artérias/cirurgia , Embolização Terapêutica/métodos , Hemorroidas/complicações , Hemorroidas/diagnóstico por imagem , Hemorroidas/terapia , Humanos , Resultado do Tratamento
3.
J Vasc Interv Radiol ; 30(9): 1452-1458, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31371137

RESUMO

PURPOSE: To evaluate the radiation dose in patients undergoing prostatic artery embolization (PAE) using cone-beam CT and 3-dimensional (3D) guidance software. MATERIALS AND METHODS: In this single-center retrospective study, 100 patients with benign prostatic hyperplasia (mean prostate volume, 83.6 mL ± 44.2; 69.4 ± 9.6 years of age; body mass index, 26.5 ± 4.2) were treated using PAE between October 2016 and April 2018. Informed consent was obtained from all participants included in the study. All patients received at least 1 intraprocedural cone-beam CT per side for evaluation of the vessel anatomy and software rendering of 3D guidance for catheter guidance. Digital subtraction angiography (DSA) was performed in the distal branches only. The total dose area product (DAP), along with the DAP attributed to fluoroscopy, DSA, and cone-beam CT, were assessed. RESULTS: Bilateral embolization was achieved in 83 patients (83%). The average total DAP was 134.4 Gy ⋅ cm2 ± 69.5 (range, 44.7-410.9 Gy ⋅ cm2). Fluoroscopy, DSA, and cone-beam CT accounted for 35.5 Gy ⋅ cm2 ± 21.3 (range, 8.6-148.6 Gy ⋅ cm2) or 26.4% (percentage of total DAP), 58.2 Gy ⋅ cm2 ± 48.3 (range, 10.3-309.3 Gy ⋅ cm2) or 43.3%, and 40.7 Gy ⋅ cm2 ± 14.5 (range, 15.9-86.3 Gy ⋅ cm2) or 30.3%, respectively. Average procedure time was 89.4 ± 27.0 minutes, and the average fluoroscopy time was 30.9 ± 12.2 minutes. CONCLUSIONS: Intraprocedural cone-beam CT in combination with 3D guidance software allows for identification and catheterization of the prostatic artery in PAE. Furthermore, the results of this trial indicate that this study protocol may lead to a low overall radiation dose.


Assuntos
Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada de Feixe Cônico , Embolização Terapêutica , Imageamento Tridimensional , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Doses de Radiação , Radiografia Intervencionista/métodos , Software , Idoso , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Embolização Terapêutica/efeitos adversos , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Hiperplasia Prostática/diagnóstico por imagem , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo
4.
Acta Radiol ; 59(11): 1316-1325, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29430936

RESUMO

Background Endovascular aneurysm repair (EVAR) requires lifelong surveillance by computed tomography angiography (CTA). This is attended by a substantial accumulation of radiation exposure. Iterative reconstruction (IR) has been introduced to approach dose reduction. Purpose To evaluate adaptive statistical iterative reconstruction (ASIR) at different levels of tube voltage concerning image quality and dose reduction potential in follow-up post EVAR. Material and Methods One hundred CTAs in 67 patients with EVAR were examined using five protocols: protocol A (n = 40) as biphasic standard using filtered back projection (FBP) at 120 kV; protocols B (n = 40), C (n = 10), and D1 (n = 5) biphasic using ASIR at 120, 100, and 80 kV, respectively; and protocol D2 (n = 5) with a monophasic splitbolus ASIR protocol at 80 kV. Image quality was assessed quantitatively and qualitatively. Applied doses were determined. Results Applied doses in ASIR protocols were significantly lower than FBP standard (up to 75%). Compared to protocol A, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) (e.g. arterial CNR intra-/extra-stent lumen: A = 35.4 ± 13.5, B = 34.2 ± 10.0, C = 29.6 ± 6.8, D1 = 32.1 ± 6.3, D2 = 40.8 ± 23.1) in protocol B were equal and in protocols C and D equal to partially inferior, however not decisive for diagnostic quality. Subjective image quality ratings in all protocols were good to excellent without impairments of diagnostic confidence (A-D2: 5), with high inter-rater agreement (60-100%). Conclusion ASIR contributes to significant dose reduction without decisive impairments of image quality and diagnostic confidence. We recommend an adapted follow-up introducing ASIR and combined low-kV in the long-term surveillance after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Procedimentos Endovasculares/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Idoso , Aorta Abdominal/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
5.
Eur Heart J ; 38(44): 3308-3317, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29029087

RESUMO

AIMS: Progressive aortic stiffening eventually leads to left ventricular (LV) hypertrophy and heart failure if left untreated. Anti-hypertensive agents have been shown to reverse this to some extent. The effects of sacubitril/valsartan (LCZ696), a dual-action angiotensin receptor blocker (ARB), and neprilysin inhibitor, on arterial stiffness and LV remodelling have not been investigated. METHODS AND RESULTS: This was a randomized, multi-centre, double-blind, double-dummy, active-controlled, parallel group, study to compare the effects on cardiovascular remodelling of sacubitril/valsartan with those of olmesartan in patients with hypertension and elevated pulse pressure. Magnetic resonance imaging scans were used to assess LV mass and local aortic distensibility, at baseline and at 12 and 52 weeks after initiation of treatment. Central pulse and systolic pressure were determined using a SphymoCor® XCEL device at each time point. A total of 114 patients were included, with 57 in each treatment group. The mean age was 59.8 years, and 67.5% were male. Demographic characteristics did not vary between the two sets of patients. Left ventricular mass index decreased to a greater extent in the sacubitril/valsartan group compared to the olmesartan group from baseline to 12 weeks (-6.36 vs. -2.32 g/m2; P = 0.039) and from baseline to 52 weeks (-6.83 vs. -3.55 g/m2; P = 0.029). These differences remained significant after adjustment for systolic blood pressure (SBP) at follow-up (P = 0.036 and 0.019 at 12 and 52 weeks, respectively) and similar signals (though formally non-significant) were observed after adjusting for changes in SBP (P = 0.0612 and P = 0.0529, respectively). There were no significant differences in local distensibility changes from baseline to 12 or 52 weeks between the two groups; however, there was a larger reduction in central pulse pressure for the sacubitril/valsartan group compared to the olmesartan group (P = 0.010). CONCLUSION: Since LV mass change correlates with cardiovascular prognosis, the greater reductions in LV mass indicate valuable advantages of sacubitril/valsartan compared to olmesartan. The finding that LV mass index decrease might be to some extent independent of SBP suggests that the effect of the dual-acting agent may go beyond those due to its BP-lowering ability.


Assuntos
Aminobutiratos/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Imidazóis/uso terapêutico , Tetrazóis/uso terapêutico , Rigidez Vascular/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos , Aorta/efeitos dos fármacos , Aorta Torácica/efeitos dos fármacos , Compostos de Bifenilo , Pressão Sanguínea/efeitos dos fármacos , Método Duplo-Cego , Combinação de Medicamentos , Hipertensão Essencial/tratamento farmacológico , Hipertensão Essencial/fisiopatologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/prevenção & controle , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Esquerda/prevenção & controle , Angiografia por Ressonância Magnética , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Neprilisina , Valsartana
6.
Rofo ; 189(9): 844-854, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28651263

RESUMO

Purpose As a supra-regional level-I trauma center, we evaluated computed tomography (CT) acquisitions of polytraumatized patients for quality and dose optimization purposes. Adapted statistical iterative reconstruction [(AS)IR] levels, tube voltage reduction as well as a split-bolus contrast agent (CA) protocol were applied. Materials and Methods 61 patients were split into 3 different groups that differed with respect to tube voltage (120 - 140 kVp) and level of applied ASIR reconstruction (ASIR 20 - 50 %). The CT protocol included a native acquisition of the head followed by a single contrast-enhanced acquisition of the whole body (64-MSCT). CA (350 mg/ml iodine) was administered as a split bolus injection of 100 ml (2 ml/s), 20 ml NaCl (1 ml/s), 60 ml (4 ml/s), 40 ml NaCl (4 ml/s) with a scan delay of 85 s to detect injuries of both the arterial system and parenchymal organs in a single acquisition. Both the quantitative (SNR/CNR) and qualitative (5-point Likert scale) image quality was evaluated in parenchymal organs that are often injured in trauma patients. Radiation exposure was assessed. Results The use of IR combined with a reduction of tube voltage resulted in good qualitative and quantitative image quality and a significant reduction in radiation exposure of more than 40 % (DLP 1087 vs. 647 mGyxcm). Image quality could be improved due to a dedicated protocol that included different levels of IR adapted to different slice thicknesses, kernels and the examined area for the evaluation of head, lung, body and bone injury patterns. In synopsis of our results, we recommend the implementation of a polytrauma protocol with a tube voltage of 120 kVp and the following IR levels: cCT 5mm: ASIR 20; cCT 0.625 mm: ASIR 40; lung 2.5 mm: ASIR 30, body 5 mm: ASIR 40; body 1.25 mm: ASIR 50; body 0.625 mm: ASIR 0. Conclusion A dedicated adaptation of the CT trauma protocol (level of reduction of tube voltage and of IR) according to the examined body region (head, lung, body, bone) combined with a split bolus CA injection protocol allows for a high-quality CT examination and a relevant reduction of radiation exposure in the examination of polytraumatized patients Key Points · Dedicated adaption of the CT trauma protocol allows for an optimized examination.. · Different levels of iterative reconstruction, tube voltage and the CA injection protocol are crucial.. · A reduction of radiation exposure of more than 40 % with good image quality is possible.. Citation Format · Kahn J, Kaul D, Böning G et al. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center. Fortschr Röntgenstr 2017; 189: 844 - 854.


Assuntos
Traumatismo Múltiplo/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/normas , Centros Médicos Acadêmicos/normas , Algoritmos , Humanos , Pessoa de Meia-Idade , Melhoria de Qualidade/normas , Doses de Radiação , Exposição à Radiação/normas , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Centros de Traumatologia/normas
7.
Eur Radiol ; 23(10): 2739-46, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23657288

RESUMO

OBJECTIVES: To assess the feasibility, safety and efficacy of real-time MR guidance and thermometry of percutaneous laser disc decompression (PLDD). METHODS: Twenty-four discs in 22 patients with chronic low-back and radicular pain were treated by PLDD using open 1.0-T magnetic-resonance imaging (MRI). A fluoroscopic proton-density-weighted turbo spin-echo (PDw TSE) sequence was used to position the laser fibre. Non-spoiled gradient-echo (GRE) sequences were employed for real-time thermal monitoring based on proton resonance frequency (PRF). Radicular pain was assessed over 6 months with a numerical rating scale (NRS). RESULTS: PLDD was technically successful in all cases, with adequate image quality for laser positioning. The PRF-based real-time temperature monitoring was found to be feasible in practice. After 6 months, 21 % reported complete remission of radicular pain, 63 % at least great pain relief and 74 % at least mild relief. We found a significant decrease in the NRS score between the pre-intervention and the 6-month follow-up assessment (P < 0.001). No major complications occurred; the single adverse event recorded, moderate motor impairment, resolved. CONCLUSIONS: Real-time MR guidance and PRF-based thermometry of PLDD in the lumbar spine under open 1.0-T MRI appears feasible, safe and effective and may pave the way to more precise operating procedures. KEY POINTS: • Percutaneous laser disc decompression (PLDD) is increasingly used instead of conventional surgery. • Open 1.0-T MRI with temperature mapping seems technically successful in monitoring PLDD. • Pain relief was at least 'great' in 64 % of patients. • No major complications occurred. • Open 1.0-T MRI appears a safe and effective option for patient-tailored PLDD.


Assuntos
Descompressão Cirúrgica/métodos , Deslocamento do Disco Intervertebral/patologia , Deslocamento do Disco Intervertebral/cirurgia , Terapia a Laser/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Termografia/métodos , Adulto , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Projetos Piloto
8.
Cardiovasc Intervent Radiol ; 36(5): 1405-10, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23580120

RESUMO

PURPOSE: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. METHODS: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. RESULTS: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 ± 6 to 6 ± 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 ± 87 to 111 ± 54 mGy × cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. CONCLUSION: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.


Assuntos
Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Radiografia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Estudos de Viabilidade , Feminino , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
9.
Eur Radiol ; 21(6): 1259-66, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21116631

RESUMO

OBJECTIVE: To evaluate the role of MRI in diagnosing acute myocarditis by correlation with immunohistological parameters. METHODS: A total of 131 patients (85 men, 46 women; mean age, 44.9 years) with suspected acute myocarditis were examined by MRI. The relative water content of the left ventricular myocardium as well as relative and late enhancement was correlated with the immunohistological results in biopsy specimens. RESULTS: Myocardial inflammation was confirmed by immunohistology in 82 of the 131 patients investigated and ruled out in 49 patients. The sensitivity, specificity and accuracy for diagnosing myocarditis in patients with immunohistologically proven disease were 48.8%, 73.8% and 57.3%, respectively, for relative enhancement, 58.3%, 57.1% and 57.9% for relative water content, and 30.6%, 88.1% and 49.6% for late enhancement. A combination of all three parameters had 39,3% sensitivity and 91,3% specificity and 62,7% accuracy. Relative enhancement and late enhancement significantly correlated with the presence of myocarditis but relative oedema did not. CONCLUSION: Relative and late enhancement significantly correlate with the presence of myocarditis, while there is no significant correlation for relative oedema. Myocarditis cannot be reliably diagnosed using any of the three MRI parameters alone but combinations of parameters will improve specificity.


Assuntos
Imageamento por Ressonância Magnética/métodos , Miocardite/patologia , Doença Aguda , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA