Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Gastrointest Endosc ; 72(4): 728-35, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20883850

RESUMO

BACKGROUND: The optimal endoscopic approach to the drainage of malignant hilar strictures remains controversial, especially with regard to the extent of desirable drainage and unilateral or bilateral stenting. OBJECTIVE: To identify useful criteria for predicting successful endoscopic drainage. DESIGN AND SETTING: Retrospective 2-center study in the greater Paris area in France. PATIENTS: A total of 107 patients who had undergone endoscopic stenting for hilar tumors Bismuth type II, III, or IV and a set of contemporaneous cross-sectional imaging data available. INTERVENTIONS: The relative volumetry of the 3 main hepatic sectors (left, right anterior, and right posterior) was assessed on CT scans. The liver volume drained was estimated and classified into 1 of 3 classes: less than 30%, 30% to 50%, and more than 50% of the total liver volume. MAIN OUTCOME MEASUREMENTS: The primary outcome was effective drainage, defined as a decrease in the bilirubin level of more than 50% at 30 days after drainage. Secondary outcomes were early cholangitis rate and survival. RESULTS: The main factor associated with drainage effectiveness was a liver volume drained of more than 50% (odds ratio 4.5, P = .001), especially in Bismuth III strictures. Intubating an atrophic sector (<30%) was useless and increased the risk of cholangitis (odds ratio 3.04, P = .01). A drainage > 50% was associated with a longer median survival (119 vs 59 days, P = .005). LIMITATIONS: Heterogeneous population and volume assessment methodology to improve in further prospective studies. CONCLUSION: Draining more than 50% of the liver volume, which frequently requires bilateral stent placement, seems to be an important predictor of drainage effectiveness in malignant, especially Bismuth III, hilar strictures. A pre-ERCP assessment of hepatic volume distribution on cross-sectional imaging may optimize endoscopic procedures.


Assuntos
Colestase/cirurgia , Neoplasias do Sistema Digestório/complicações , Drenagem/métodos , Fígado/patologia , Stents , Idoso , Atrofia , Neoplasias dos Ductos Biliares/complicações , Ductos Biliares Intra-Hepáticos , Bilirrubina/sangue , Colangiocarcinoma , Colangiopancreatografia Retrógrada Endoscópica , Colangite/epidemiologia , Colangite/cirurgia , Colestase/mortalidade , Neoplasias do Sistema Digestório/patologia , Endoscopia do Sistema Digestório , Feminino , Neoplasias da Vesícula Biliar/complicações , Humanos , Estimativa de Kaplan-Meier , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Tamanho do Órgão , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
J Transl Med ; 6: 28, 2008 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-18533990

RESUMO

BACKGROUND: Esophageal tumors generally bear a poor prognosis. Radical surgery is generally the only curative method available but is not feasible in the majority of patients; palliative therapy with stent placement is generally performed. It has been demonstrated that High Intensity Ultrasound can induce rapid, complete and well-defined coagulation necrosis. Thus, for the treatment of esophageal tumors, we have designed an ultrasound applicator that uses an intraluminal approach to fill up this therapeutic gap. METHODS: Thermal ablation is performed with water-cooled ultrasound transducers operating at a frequency of 10 MHz. Single lesions extend from the transducer surface up to 10 mm in depth when applying an intensity of 14 W/cm2 for 10s. A lumen inside the therapy applicator provides path for an endoscopic ultrasound imaging probe operating at a frequency of 12 MHz. The mechanical rotation of the applicator around its axis enables treatment of sectorial or cylindrical volumes. This method is thus particularly suitable for esophageal tumors that may develop only on a portion of the esophageal circumference. Previous experiments were conducted from bench to in vivo studies on pig esophagi. RESULTS: Here we report clinical results obtained on four patients included in a pilot study. The treatment of esophageal tumors was performed under fluoroscopic guidance and ultrasound imaging. Objective tumor response was obtained in all cases and a complete necrosis of a tumor was obtained in one case. All patients recovered uneventfully and dysphagia improved significantly within 15 days, allowing for resuming a solid diet in three cases. CONCLUSION: This clinical work demonstrated the efficacy of intraluminal high intensity ultrasound therapy for local tumor destruction in the esophagus.


Assuntos
Adenocarcinoma/terapia , Carcinoma de Células Escamosas/terapia , Neoplasias Esofágicas/terapia , Terapia por Ultrassom/métodos , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Projetos Piloto , Resultado do Tratamento , Terapia por Ultrassom/instrumentação
3.
Gastroenterol Clin Biol ; 31(8-9 Pt 1): 670-1, 2007.
Artigo em Francês | MEDLINE | ID: mdl-17925766

RESUMO

We report the case of a 17 year old man who presented with several episodes of acute pancreatitis due to a duodenal duplication. This was successfully treated by an incision by sphincterotome during interventional duodenoscopy. The patient is symptom free without recurrence 20 months after endoscopic treatment.


Assuntos
Duodenoscopia , Duodeno/anormalidades , Duodeno/cirurgia , Pancreatite/etiologia , Doença Aguda , Adolescente , Humanos , Masculino
5.
Gastrointest Endosc ; 57(2): 178-82, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12556780

RESUMO

BACKGROUND: The systematic use of metal stents to treat biliary obstruction is restricted by high cost compared with plastic stents. The aims of this study were to compare cost and efficacy of plastic stents and metal stents in the treatment of patients with malignant common bile duct strictures and to define factors that predict survival of these patients. METHODS: One hundred eighteen patients (mean age 75 years) with malignant strictures of the common bile duct were randomized to placement of a plastic stent or metal stent. Comparisons were made with the Mann-Whitney or chi-square test as indicated; survival rates were compared with a Cox proportional hazards model. RESULTS: There was no significant difference in survival between the two groups. Time to first obstruction was longer for patients in the metal stent group (metal stent, median not reached vs. plastic stent, 5 months; p = 0.007). The number of additional days of hospitalization, days of antibiotic therapy, and the numbers of ERCPs and transabdominal US procedures was significantly higher in the plastic stent group. After multivariate analysis, only the presence of liver metastases was independently related to survival (p < 0.0005; OR = 2.25). This variable defined a group with a shorter survival. Median survival of patients with hepatic metastasis at diagnosis was 2.7 months compared with 5.3 months for patients without liver metastasis; in the latter group, the overall cost associated with metal stents was lower than for plastic stents. CONCLUSIONS: Metal stent placement is the most effective treatment of inoperable malignant common bile duct stricture. Placement of a metal stent is cost effective in patients without hepatic metastases, whereas a plastic stent should be placed in patients with spread of the tumor to the liver.


Assuntos
Neoplasias do Ducto Colédoco/mortalidade , Neoplasias do Ducto Colédoco/terapia , Metais/uso terapêutico , Cuidados Paliativos/métodos , Plásticos/uso terapêutico , Stents , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Colestase Intra-Hepática/mortalidade , Colestase Intra-Hepática/patologia , Colestase Intra-Hepática/terapia , Neoplasias do Ducto Colédoco/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Probabilidade , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento
6.
Gastrointest Endosc ; 56(6): 909-15, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12447312

RESUMO

BACKGROUND: Local and infiltrative extension make some biliary carcinomas accessible to nonoperative intraductal destruction. This study assessed the clinical feasibility and short-term results of local tumor destruction with an intraductal high-intensity US probe during ERCP. METHODS: The probe is a flexible catheter with an 8 x 2.8 mm US transducer and a lumen for a guidewire. Ten patients (6 women, 4 men; mean age 74.8 years) were treated with this device. Lesions treated included carcinoma of the papilla (3), bile duct cholangiocarcinoma (2), Bismuth grade I and II hilar cholangiocarcinomas (4), and intrahepatic cystadenocarcinoma (1). Two patients underwent US therapy before surgery. Treatment was performed during standard ERCP: the probe was inserted through the malignant stricture and US therapy was applied over 360 degrees under fluoroscopic control. RESULTS: No serious adverse effects were observed; right upper abdominal pain developed in one patient for 12 hours. In one patient, histopathologic assessment of the resected tumor revealed extensive coagulation necrosis with inflammation up to 10 mm in depth surrounding the bile duct lumen. In the other operated patient, biopsy specimens from the treated portion of the bile duct were negative for malignancy. There was complete regression of cholangiocarcinoma of the bile duct in our patient, allowing for permanent stent removal (follow-up 30 months). A partial response was noted in 4 other patients and no response in 3 patients. CONCLUSIONS: This new method of intraductal tumor destruction by high-intensity US during ERCP is feasible and can induce objectively measurable tumor necrosis. Long-term follow-up will determine whether this method is curative in some cases and if it can reduce the need for biliary stent placement.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Neoplasias Duodenais/diagnóstico por imagem , Endoscopia Gastrointestinal , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/cirurgia , Ductos Biliares Intra-Hepáticos/cirurgia , Colangiocarcinoma/cirurgia , Neoplasias Duodenais/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA