Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
2.
Radiology ; 309(2): e222590, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37962507

RESUMO

Because ionizing radiation is widely used in medical imaging and in military, industry, and commercial applications, programmatic management and advancement in knowledge is needed, especially related to the health effects of low-dose radiation. The U.S. Congress in partnership with the U.S. Department of Energy called on the National Academies of Sciences, Engineering, and Medicine (NASEM) to develop a long-term strategic and prioritized agenda for low-dose radiation research. Low doses were defined as dose amounts less than 100 mGy or low-dose rates less than 5 mGy per hour. The 2022 NASEM report was divided into sections detailing the low-dose radiation exposure and health effects, scientific basis for radiation protection, status of low-dose radiation research, a prioritized radiation research agenda, and essential components of a low-dose radiation research program, including resources needed and recommendations for financial recourse. The purpose of this review is to summarize this report and examine the recommendations to assess how these pertain to the practice of radiology and medicine.


Assuntos
Proteção Radiológica , Radiologia , Humanos , Radiografia , Indústrias
3.
Pediatr Blood Cancer ; 70 Suppl 4: e30298, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37025033

RESUMO

Diagnostic imaging is essential in the diagnosis and management, including surveillance, of known or suspected cancer in children. The independent and combined roles of the various modalities, consisting of radiography, fluoroscopy, ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI), and nuclear medicine (NM), are both prescribed through protocols but also function in caring for complications that may occur during or subsequent to treatment such as infection, bleeding, or organ compromise. Use of a specific imaging modality may be based on situational circumstances such as a brain CT or MR for a new onset seizure, chest CT for respiratory signs or symptoms, or US for gross hematuria. However, in many situations, there are competing choices that do not easily lend themselves to a formulaic approach as options; these situations depend on the contributions of a variety of factors based on a combination of the clinical scenario and the strengths and limitations of the imaging modalities. Therefore, an improved understanding of the potential influence of the imaging decision pathways in pediatric cancer care can come from comparison among the individual diagnostic imaging modalities. The purpose of the following material to is to provide such a comparison. To do this, pediatric imaging content experts for the individual modalities of radiography and fluoroscopy, US, CT, MRI, and NM will discuss the individual modality strengths and limitations.


Assuntos
Neoplasias , Ressonância de Plasmônio de Superfície , Humanos , Criança , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Oncologia , Cintilografia , Imageamento por Ressonância Magnética/métodos
4.
J Appl Clin Med Phys ; 23 Suppl 1: e13799, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36382354

RESUMO

This section focuses on the professional workforce comprised of the primary medical specialties that utilize ionizing radiation in their practices. Those discussed include the specialties of radiology and radiation oncology, as well as the subspecialties of radiology, namely diagnostic radiology, interventional radiology, nuclear radiology, and nuclear medicine. These professionals provide essential health care services, for example, the interpretation of imaging studies, the provision of interventional procedures, radionuclide therapeutic treatments, and radiation therapy. In addition, they may be called on to function as part of a radiologic emergency response team to care for potentially exposed persons following radiation events, for example, detonation of a nuclear weapon, nuclear power plant accidents, and transportation incidents. For these reasons, maintenance of an adequate workforce in each of these professions is essential to meeting the nation's future needs. Currently, there is a shortage for all physicians in the medical radiology workforce.


Assuntos
Medicina , Medicina Nuclear , Humanos , Estados Unidos , Diagnóstico por Imagem , Radiologia Intervencionista , Recursos Humanos
7.
Radiol Technol ; 93(3): 255-267, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35017269

RESUMO

PURPOSE: The purpose of the study was to examine mean differences between intrapersonal and institutional variables and the overall perception of radiation safety (OPRS) among U.S. radiologic technologists. The study also sought to demonstrate the applicability of the socioecological model for radiation safety decision-making. METHODS: A quantitative, cross-sectional design with the Radiation Actions and Dimensions of Radiation Safety survey instrument was used to collect data and guide hypotheses testing. The 425 research participants included radiologic technologists working in radiography, mammography, computed tomography, and radiology management. Categorical and descriptive data were calculated, and 1-way analysis of variance tests were used to analyze hypotheses. RESULTS: Seven main effects demonstrated mean differences between groups for the OPRS, including age (F5,419 = 2.55, P = .03), years of experience (F5,419 = 4.27, P = .001), primary employed imaging modality (F2,422 = 9.04, P < .001), primary role (F2,422 = 4.58, P = .01), shift length (F3,421 = 10.33, P < .001), primary practice facility (F4,404 = 5.00, P = .001), and work shift (F3,405 = 4.14, P = .007), with shift length having the largest effect. Level of education, employment status, number of imaging credentials, gender, patient population, and practice location were not significant at the level of P ≤ .05. DISCUSSION: Radiation safety culture is a multidimensional topic that requires consideration of several intervening influences, making the socioecological model well aligned when considering radiation safety culture and radiation safety perception in medical imaging. Previous research on radiation safety perception among radiologic technologists demonstrated that leadership actions, teamwork across imaging stakeholders, organizational learning, and questioning behavior are drivers of OPRS. However, this study's findings demonstrate that radiologic technologist scheduling practices and primary employed imaging modalities also should be considered when seeking to improve OPRS. CONCLUSION: This study presents an extensive examination of intrapersonal and institutional variables on OPRS among U.S.-based radiologic technologists and provides findings to support radiation safety culture decision-making in medical imaging, particularly for shift length considerations.


Assuntos
Gestão da Segurança , Tecnologia Radiológica , Estudos Transversais , Humanos , Percepção , Inquéritos e Questionários , Tecnologia Radiológica/educação
11.
Pediatr Radiol ; 51(4): 532-543, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33743037

RESUMO

Medical imaging is foundational in the care of children, and much of the medical imaging province depends on ionizing radiation: radiography, fluoroscopy, CT and nuclear imaging. Many considerations for this imaging in children are distinct in the domains of appropriate radiation use, other factors that determine examination quality, the opportunities to engage and educate through networking, and the translation of research efforts. Given these needs, it is worth approaching the contributions and their impact by the pediatric radiology community, especially to the enhancement of this value in the care of children.


Assuntos
Radiologia , Criança , Fluoroscopia , Humanos , Doses de Radiação , Radiação Ionizante , Radiografia
12.
Pediatr Ann ; 49(9): e370-e373, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32929511

RESUMO

Medical imaging in children makes up a considerable percentage of all imaging procedures performed in the United States. Although in recent years there has been a 15% to 20% reduction in the exposure to ionizing radiation from medical imaging in the US population, the total number of computed tomography (CT) scans has increased from 2006 to 2016, and about 85% of all medical ionizing radiation in children is due to CT. [Pediatr Ann. 2020;49(9):e370-e373.].


Assuntos
Pediatras , Exposição à Radiação , Tomografia Computadorizada por Raios X , Criança , Humanos , Doses de Radiação , Estudos Retrospectivos , Estados Unidos
15.
Radiol Imaging Cancer ; 1(1): e190027, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-33778672

RESUMO

Purpose: To create and validate a systematic observer performance platform for evaluation of simulated liver lesions at pediatric CT and to test this paradigm to measure the effect of radiation dose reduction on detection performance and reader confidence. Materials and Methods: Thirty normal pediatric (from patients aged 0-10 years) contrast material-enhanced, de-identified abdominal CT scans obtained from July 1, 2012, through July 1, 2016, were retrospectively collected from the clinical database. The study was exempt from institutional review board approval. Zero to three simulated, low-contrast liver lesions (≤6 mm) were digitally inserted by using software, and noise was added to simulate reductions in volume CT dose index (representing radiation dose estimation) of 25% and 50%. Pediatric, abdominal, and resident radiologists (three of each) reviewed 90 data sets in three sessions using an online interface, marking each lesion location and rating confidence (scale, 0-100). Statistical analysis was performed by using software. Results: Mixed-effects models revealed a significant decrease in detection sensitivity as radiation dose decreased (P < .001). The mean confidence of the full-dose and 25% dose reduction examinations was significantly higher than that of the 50% dose reduction examinations (P = .011 and .012, respectively) but not different from one another (P = .866). Dose was not a significant predictor of time to complete each case, and subspecialty was not a significant predictor of sensitivity or false-positive results. Conclusion: Sensitivity for lesion detection significantly decreased as dose decreased; however, confidence did not change between the full-dose and 25% reduced-dose scans. This suggests that readers are unaware of this decrease in performance, which should be accounted for in clinical dose reduction efforts.Keywords: Abdomen/GI, CT, Liver, Observer Performance, Pediatrics, Perception Image© RSNA, 2019.


Assuntos
Neoplasias Hepáticas , Pediatria , Tomografia Computadorizada por Raios X , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Neoplasias Hepáticas/diagnóstico por imagem , Doses de Radiação , Estudos Retrospectivos
16.
Health Phys ; 116(2): 279-281, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30585976

RESUMO

The 54th Annual Meeting of the National Council on Radiation Protection and Measurements was held at the Hyatt Regency Bethesda, Maryland, on 5-6 March 2018. This annual meeting, entitled "Radiation Protection Responsibility in Medicine," was the first to deal entirely with radiation protection in medical imaging since the 43rd annual meeting in 2007 ("Advances in Radiation Protection in Medicine"). The 2018 meeting addressed updates for various modalities and included discussion on radiation dose metrics and benefit/risk dialogue. In addition, the 2018 meeting dedicated entire sessions to patient communications and innovations in medical imaging.


Assuntos
Proteção Radiológica , Diagnóstico por Imagem/efeitos adversos , Diagnóstico por Imagem/métodos , Humanos , Segurança do Paciente , Proteção Radiológica/métodos , Radiometria
17.
Artigo em Inglês | MEDLINE | ID: mdl-29970384

RESUMO

Recent evidence has implicated EFL1 in a phenotype overlapping Shwachman-Diamond syndrome (SDS), with the functional interplay between EFL1 and the previously known causative gene SBDS accounting for the similarity in clinical features. Relatively little is known about the phenotypes associated with pathogenic variants in the EFL1 gene, but the initial indication was that phenotypes may be more severe, when compared with SDS. We report a pediatric patient who presented with a metaphyseal dysplasia and was found to have biallelic variants in EFL1 on reanalysis of trio whole-exome sequencing data. The variant had not been initially reported because of the research laboratory's focus on de novo variants. Subsequent phenotyping revealed variability in her manifestations. Although her metaphyseal abnormalities were more severe than in the original reported cohort with EFL1 variants, the bone marrow abnormalities were generally mild, and there was equivocal evidence for pancreatic insufficiency. Despite the limited number of reported patients, variants in EFL1 appear to cause a broader spectrum of symptoms that overlap with those seen in SDS. Our report adds to the evidence of EFL1 being associated with an SDS-like phenotype and provides information adding to our understanding of the phenotypic variability of this disorder. Our report also highlights the value of exome data reanalysis when a diagnosis is not initially apparent.


Assuntos
Doenças da Medula Óssea/genética , Insuficiência Pancreática Exócrina/genética , GTP Fosfo-Hidrolases/genética , GTP Fosfo-Hidrolases/fisiologia , Lipomatose/genética , Adolescente , Doenças da Medula Óssea/diagnóstico , Insuficiência Pancreática Exócrina/diagnóstico , Feminino , Variação Genética/genética , Humanos , Lipomatose/diagnóstico , Mutação , Osteocondrodisplasias/genética , Osteocondrodisplasias/fisiopatologia , Fatores de Alongamento de Peptídeos , Fenótipo , Proteínas/genética , Ribonucleoproteína Nuclear Pequena U5 , Síndrome de Shwachman-Diamond , Sequenciamento do Exoma
18.
Pediatr Radiol ; 48(8): 1101-1107, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29721598

RESUMO

BACKGROUND: Whole-body magnetic resonance imaging (MRI) is an evolving and increasingly powerful imaging tool with a variety of applications in the pediatric patient population. Variability exists among radiology practices in how this MRI tool is used and how it is performed. OBJECTIVE: Our objective was to gain an improved understanding of technical and utilization practices in pediatric whole-body MRI across North America by exploring indications for exam performance, determining referral patterns, and assessing technical protocols and procedures. MATERIALS AND METHODS: A 19-question survey was generated in Survey Monkey and distributed in 2016 to the Society for Pediatric Radiology membership. The survey asked questions that included practice type, imaging modality preferences for diseases commonly evaluated with whole-body MRI, MRI field strength and sequence selection, and billing practices. RESULTS: Data were obtained from 62 unique responses to the survey, representing 471 physicians. The majority (93%) practice in an academic institution or private practice with academic affiliation and most practices have utilized whole-body MRI for less than 6 years. Whole-body MRI is performed in pediatric patients 0 to 18 years of age, and was the preferred imaging modality for diagnosis/staging/follow-up in neurofibromatosis, type 1 (75%), chronic recurrent multifocal osteomyelitis (CRMO) (74%), cancer predisposition syndromes (75%), vasculopathies (50%) and disseminated/multifocal infection (49%). The most commonly utilized sequences are coronal short tau inversion recovery (STIR) (90%), coronal T1 with or without fat saturation (65%), and axial diffusion-weighted imaging (DWI) (48%). No preference was shown for either 1.5-T or 3-T systems. Wide variability was seen in preference for billing code utilization, though the majority use chest/abdomen/pelvis (57%) or unlisted MRI (37%) codes. CONCLUSION: Radiology practitioners - represented by the Society for Pediatric Radiology pediatric radiologists - are using whole-body MRI in the imaging care of pediatric patients for a variety of indications. Survey results reveal some variability in exam utilization and technical performance practices among those pediatric radiologists who perform whole-body MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Padrões de Prática Médica/estatística & dados numéricos , Imagem Corporal Total/métodos , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , América do Norte , Inquéritos e Questionários
20.
AJR Am J Roentgenol ; 210(3): 641-647, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29323552

RESUMO

OBJECTIVE: Imaging registries afford opportunities to study large, heterogeneous populations. The purpose of this study was to examine the American College of Radiology CT Dose Index Registry (DIR) for dose-related demographics and metrics of common pediatric body CT examinations. MATERIALS AND METHODS: Single-phase CT examinations of the abdomen and pelvis and chest submitted to the DIR over a 5-year period (July 2011-June 2016) were evaluated (head CT frequency was also collected). CT examinations were stratified into five age groups, and examination frequency was determined across age and sex. Standard dose indexes (volume CT dose index, dose-length product, and size-specific dose estimate) were categorized by body part and age. Contributions to the DIR were also categorized by region and practice type. RESULTS: Over the study period 411,655 single-phase pediatric examinations of the abdomen and pelvis, chest, and head, constituting 5.7% of the total (adult and pediatric) examinations, were submitted to the DIR. Head CT was the most common examination across all age groups. The majority of all scan types were performed for patients in the second decade of life. Dose increased for all scan types as age increased; the dose for abdominopelvic CT was the highest in each age group. Even though the DIR was queried for single-phase examinations only, as many as 32.4% of studies contained multiple irradiation events. When these additional scans were included, the volume CT dose index for each scan type increased. Among the studies in the DIR, 99.8% came from institutions within the United States. Community practices and those that specialize in pediatrics were nearly equally represented. CONCLUSION: The DIR provides valuable information about practice patterns and dose trends for pediatric CT and may assist in establishing diagnostic reference levels in the pediatric population.


Assuntos
Guias de Prática Clínica como Assunto , Padrões de Prática Médica/estatística & dados numéricos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Radiografia Abdominal , Radiografia Torácica , Sistema de Registros , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA