Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ecotoxicol Environ Saf ; 283: 116768, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-39067078

RESUMO

Increased anthropogenic activities over the last decades have led to a gradual increase in cadmium content in the soil, which, due to its high mobility in soil, makes Cd accumulation in plants a serious threat to the health of animals and humans. Plant hormones including melatonin (Mel) and brassinosteroids (BR) are known to provide tolerance against various abiotic stresses. In this work, the role of combined and separate exogenous application of Mel and BR on Cd stress in cherry tomato plants was examined. Cd stress significantly reduced tomato growth by inducing oxidative stress and reduced K+ uptake in roots and shoots. Combined application of Mel and BR reduced detrimental effects of Cd in tomato by (i) reducing Cd accumulation in the shoot; (ii) increasing the activities of different antioxidants (SOD, CAT, APX, GR); (iii) triggering higher expression of genes relating to Cd vacuolar sequestration (Na+/H+ EXCHANGER, SlNHX1; NATURAL RESISTANCE-ASSOCIATED MACROPHAGE PROTEIN 6, SlNRAMP6), and Cd transport and detoxification (HEAVY-METAL-ASSOCIATED 3, SlHMA3; PLANT CADMIUM RESISTANT 2, SlPCR2); and (iv) improving plant K+ homeostasis and contents in root and shoot. The latter trait was associated with the reduced gene expression of K+-permeable outward rectifying channel (SlGORK3), and transcriptional upregulation of high affinity potassium transporter 5 (SIHAK5) under Cd stress. A separate application of Mel and BR showed tissue-specific regulation of tomato growth and Cd tolerance by regulating antioxidant activities, K+ uptake, Cd uptake, and translocation from root to shoot and their endogenous contents. Melatonin per se was more effective in improving Cd tolerance in shoot while beneficial BR effects were more pronounced in roots, and their combined application was effective in both tissues. Taken together, reported results show tissue-specific regulation of Cd tolerance by Mel and BR in cherry tomato plants and demonstrate the efficiency of combined Mel + BR treatment as a practical tool to reduce Cd accumulation and mitigate its negative effects on plant growth.


Assuntos
Brassinosteroides , Cádmio , Melatonina , Raízes de Plantas , Poluentes do Solo , Solanum lycopersicum , Solanum lycopersicum/efeitos dos fármacos , Solanum lycopersicum/crescimento & desenvolvimento , Melatonina/farmacologia , Cádmio/toxicidade , Brassinosteroides/farmacologia , Poluentes do Solo/toxicidade , Raízes de Plantas/efeitos dos fármacos , Raízes de Plantas/metabolismo , Antioxidantes/metabolismo , Estresse Oxidativo/efeitos dos fármacos , Reguladores de Crescimento de Plantas , Potássio/metabolismo , Brotos de Planta/efeitos dos fármacos , Brotos de Planta/crescimento & desenvolvimento , Regulação da Expressão Gênica de Plantas/efeitos dos fármacos
2.
Anal Chem ; 96(26): 10630-10638, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38912708

RESUMO

Paper-based lateral flow immunoassays (LFIAs) are cost-effective, portable, and simple methods for detection of diverse analytes, which however only provide qualitative or semiquantitative results and lack sufficient sensitivity. A combination of LFIA and electrochemical detection, namely, electrochemical lateral flow immunoassay (eLFIA), enables quantitative detection of analytes with high sensitivity, but the integration of external electrodes makes the system relatively expensive and unstable. Herein, the working, counter, and reference electrodes were prepared directly on the nitrocellulose membrane using screen printing, which remarkably simplified the structure of eLFIA and decreased the cost. Moreover, a horseradish peroxidase (HRP)-based electrochemical signal amplification strategy was used for further increasing the analytical sensitivity. HRP captured on the working electrode can catalyze the oxidation of tetramethylbenzidine (TMB) to form the TMB-TMBox precipitate on the electrode surface, which as an electrochemically active product can output an amplified current for quantification. We demonstrated that the eLFIA could detect low-abundant inflammatory biomarkers in human plasma samples with limits of detection of 0.17 and 0.54 pg mL-1 for interleukin-6 and C-reactive protein, respectively. Finally, a fully portable system was fabricated by integrating eLFIA with a flexible and wireless electrochemical workstation, realizing the point-of-care detection of interleukin-6.


Assuntos
Biomarcadores , Proteína C-Reativa , Técnicas Eletroquímicas , Eletrodos , Interleucina-6 , Humanos , Imunoensaio/métodos , Imunoensaio/instrumentação , Técnicas Eletroquímicas/instrumentação , Biomarcadores/sangue , Biomarcadores/análise , Interleucina-6/sangue , Interleucina-6/análise , Proteína C-Reativa/análise , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Limite de Detecção , Inflamação/sangue , Inflamação/diagnóstico , Benzidinas
3.
Heliyon ; 10(3): e25158, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38322892

RESUMO

Objective: This study aimed to assess the current status of carcinoembryonic antigen (CEA) detection. We evaluated the correlation, consistency, and comparability of CEA results among six automated immunoassays, and combined with the results of CEA trueness verification of the Beijing Center for Clinical Laboratories (BCCL) for further analysis. Methods: Abbott Architect i2000, Beckman DxI800, Roche Cobas E601, Diasorin Liaison XL, Maccura IS1200, and Autolumo A2000 were used to detect 40 individual serum CEA samples. Taking the optimal analytical quality specifications calculated from data on biological variation as the evaluation criterion. Passing-Bablok regression and Bland-Altman analysis were performed between each assay and all-assays median values to evaluate the correlation and relative difference. The concordance correlation coefficient (CCC) was used for consistency analysis. Additionally, the trueness verification program used samples at three concentration levels to assess the bias, coefficient of variation (CV), and total error (TE) between the average measured values and the target value. Results: The Spearman's rank correlation coefficient (rs) was ≥0.996 and the CCC ranged between 0.9448 and 0.9990 for each assay vs. all-assays median. Considering the all-assays median value of each sample as a reference, there were proportional and systematic differences according to the Passing-bablok regression analysis. The relative difference of the four assays (Abbott Architect i2000, Autolumo A2000, Diasorin Liaison XL, and Maccura IS1200) met the optimal analytical quality specifications. On the other hand, Beckman DxI800 (13.2 %) and Roche Cobas E601 (-9.0 %) were only able to fulfill the desirable analytical quality specifications. The average pass rates for bias, CV, and TE of the trueness verification program were 80 %, 98 %, and 96 %, respectively. Conclusions: The six automated immunoassays vs. all-assays median have a good correlation in CEA detection. However, there is a lack of comparability of CEA results. Further improvements are needed in harmonization among CEA detections.

4.
Clin Chim Acta ; 552: 117701, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081446

RESUMO

AIMS: We analyzed the differentially expressed proteins (DEPs) in serum and urine in order to provide new potential biomarkers for MM. METHODS: Data-Independent Acquisition-based proteomics of serum and urine was performed to identify potential biomarkers for MM patients. Then we performed Western Blotting (WB), ELISA along with their ROC curve analysis to confirm DEPs. RESULTS: A total of 1653 proteins in serum and 4519 proteins in urine were identified using Data-Dependent Acquisition method. VCP was the only protein that showed significant differences in different comparison groups in both serum and urine. Pathway analysis revealed that protein processing in the endoplasmic reticulum was the most relevant pathway associated with MM. Furthermore, the increased expression of HSP90B1, VCP, CTSA, HYOU1, PDIA4, and RAB7A was detected by WB. The results of ELISA indicated that a combination of VCP and CTSA provided a high area under curve (AUC) value of 0.883 (95 % CI, 0.769-0.997, p < 0.001) to diagnose NDMM. The combination of VCP, CTSA, ALB, and HGB exhibited better performance (AUC = 0.981), with 100 % specificity and 86.7 % sensitivity. CONCLUSION: These findings suggest VCP and CTSA exhibit potential as biomarkers for MM, which may be helpful in the molecular mechanisms and pathogenesis upon further investigation.


Assuntos
Mieloma Múltiplo , Humanos , Biomarcadores , Proteínas , Proteômica , Curva ROC , Proteína com Valosina
5.
J Inflamm Res ; 16: 5779-5789, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38076333

RESUMO

Purpose: Outcomes after autologous stem cell transplantation (ASCT) are quite variable and difficult to predict. Second-generation flow, second-generation sequencing, and other tests are invasive and expensive for patients. In this study, we aimed to analyze laboratory data before and after transplantation to look for laboratory indicators that could predict disease progression in patients with newly diagnosed multiple myeloma (NDMM) patients underwent ASCT. Patients and Methods: Standard complete blood count (CBC) parameters, clinical biochemical, and immunological indicators on day -5 and day 90 after ASCT were obtained. Receiver-operating characteristic (ROC) curve was used to determine the cutoff values, we evaluated the predictive abilities of laboratory parameters for progression-free survival (PFS). Univariate and multivariate analyses were performed to evaluate the prognostic significance of variables associated with the PFS of 166 NDMM who underwent ASCT. Results: At day-5, a low absolute monocyte count (AMC, p=0.001), systemic inflammation response index<1.56 (SIRI, P=0.03), serum calcium (p=0.02), and albumin (p=0.006) can predict for superior PFS. At Day +90, a high absolute neutrophil count (ANC, p = 0.008) and lymphocyte-to-monocyte ratio (LMR, p = 0.02), a low neutrophil-to-lymphocyte ratio (NLR, p =0.02) and SIRI<0.41 (p=0.02) predicted for superior PFS. Conclusion: There are inflammation-related indicators derived from peripheral blood cell count (WBCC) - ANC, NLR, SIRI, and LMR - which can serve as potential biomarkers for predicting PFS of NDMM patients underwent ASCT.

6.
J Clin Lab Anal ; 37(11-12): e24936, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37395487

RESUMO

BACKGROUND: In this study, we explored the commutability of reference materials (RMs) for carcinoembryonic antigen (CEA), selected the appropriate diluent matrix of the first International Reference Preparation (IRP) 73/601 of the World Health Organization (WHO 73/601) for CEA, and improved the comparability of CEA measurement results among different assay systems. METHODS: Forty serum samples were divided into five aliquots. WHO 73/601 was diluted into nine concentrations using five diluents with different components, and the candidate RMs for CEA at five concentrations (C1-C5) were prepared by the Beijing Clinical Laboratory Center (BCCL). The samples were analyzed via five automated CEA immunoassays. RESULTS: Carcinoembryonic antigen candidate RMs were commutable among all immunoassays based on the CLSI approach and among 7 of 10 assay combinations based on the IFCC approach. WHO 73/601 diluted in phosphate-buffered saline (PBS) was commutable among all assays based on the CLSI approach and among 5 of 10 pairwise comparisons based on the IFCC approach with correction of bias at diluted concentrations, except for the lowest concentration, which had the smallest variation among systems. The median percentage biases among assays were decreased after calibration. CONCLUSION: The BCCL candidate RMs (C2-C5) for CEA were commutable among all immunoassays. WHO 73/601 RMs diluted in a PBS buffer matrix were selected as common calibrators for five immunoassays, which reduced bias, thereby effectively improving the harmonization of CEA detection; therefore, they could be used to assign values to CEA candidate RMs developed by BCCL. Our findings promote the harmonization of CEA detection in immunoassays.


Assuntos
Antígeno Carcinoembrionário , Serviços de Laboratório Clínico , Humanos , Imunoensaio , Laboratórios , Laboratórios Clínicos , Padrões de Referência
7.
BMC Musculoskelet Disord ; 24(1): 376, 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37173661

RESUMO

BACKGROUND: Myofascial pain syndrome (MPS) is a common musculoskeletal pain and dysfunction, which is characterised by myofascial trigger points. Therapeutic physical modalities, as potentially effective treatment options, are commonly used in the clinical setting for the patients with MPS. OBJECTIVE: This systematic review aimed to evaluate the safety and effectiveness of therapeutic physical modalities in the treatment of MPS, investigate its therapeutic mechanisms and provide a scientific evidence-based decision. METHODS: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, the PubMed, Cochrane Central Library, Embase, and CINAHL databases were searched for randomized controlled clinical studies published from database inception to October 30, 2022. A total of 25 articles met the study inclusion criteria. Data were extracted from these studies and a qualitative analysis was performed. RESULTS: Transcutaneous electrical nerve stimulation therapy, extracorporeal shock wave therapy, laser therapy, and other therapeutic physical modalities have been demonstrated to improve the pain symptoms, joint mobility, psychological state, and quality of life in the patients with MPS and no side effects have been reported. The curative effect of therapeutic physical modalities was found to be possibly associated with increased blood perfusion and oxygen supply in ischaemic tissues, reduced hyperalgesia in the peripheral and central nerves, and decreased involuntary muscle contractions. CONCLUSION: The systematic review has shown that therapeutic physical modalities could provide a safe and effective therapeutic option for MPS. However, the consensus is currently lacking regarding the optimal treatment paradigm, therapeutic parameters, and mutual combination of therapeutic physical modalities. The clinical trials with robust quality are required to further promote the evidence-based application of therapeutic physical modalities for MPS.


Assuntos
Fibromialgia , Dor Musculoesquelética , Síndromes da Dor Miofascial , Humanos , Qualidade de Vida , Síndromes da Dor Miofascial/diagnóstico , Síndromes da Dor Miofascial/terapia , Modalidades de Fisioterapia , Pontos-Gatilho
8.
Angew Chem Int Ed Engl ; 60(21): 11769-11773, 2021 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-33709454

RESUMO

Cell junctions are protein structures located at specific cell membrane domains that determine key processes in multicellular development. Here we report spatially selective imaging of cell junctions by electrochemiluminescence (ECL) microscopy. By regulating the concentrations of luminophore and/or co-reactant, the thickness of ECL layer can be controlled to match with the spatial location of different cell junctions. At a low concentration of luminophore, ECL generation is confined to the electrode surface, thus revealing only cell-matrix adhesions at the bottom of cells. While at a high concentration of luminophore, the ECL layer can be remarkably extended by decreasing the co-reactant concentration, thus allowing the sequential imaging of cell-matrix and cell-cell junctions at the bottom and near the apical surface of cells, respectively. This strategy not only provides new insights into the ECL mechanisms but also promises wide applications of ECL microscopy in bioimaging.


Assuntos
Junções Intercelulares/metabolismo , Microscopia/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Luminescência , Substâncias Luminescentes/química , Células MCF-7 , Compostos Organometálicos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA