Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 29(7): 3390-3400, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31016441

RESUMO

OBJECTIVE: Percutaneous biliary interventions (PBIs) can be associated with a high patient radiation dose, which can be reduced when national diagnostic reference levels (DRLs) are kept in mind. The aim of this multicentre study was to investigate patient radiation exposure in different percutaneous biliary interventions, in order to recommend national DRLs. METHODS: A questionnaire asking for the dose area product (DAP) and the fluoroscopy time (FT) in different PBIs with ultrasound- or fluoroscopy-guided bile duct punctures was sent to 200 advanced care hospitals. Recommended national DRLs are set at the 75th percentile of all DAPs. RESULTS: Twenty-three facilities (9 interventional radiology depts. and 14 gastroenterology depts.) returned the questionnaire (12%). Five hundred sixty-five PBIs with 19 different interventions were included in the analysis. DAPs (range 4-21,510 cGy·cm2) and FTs (range 0.07-180.33 min) varied substantially depending on the centre and type of PBI. The DAPs of initial PBIs were significantly (p < 0.0001) higher (median 2162 cGy·cm2) than those of follow-up PBIs (median 464 cGy·cm2). There was no significant difference between initial PBIs with ultrasound-guided bile duct puncture (2162 cGy·cm2) and initial PBIs with fluoroscopy-guided bile duct puncture (2132 cGy·cm2) (p = 0.85). FT varied substantially (0.07-180.33 min). CONCLUSIONS: DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. PBI with US-guided bile duct puncture did not reduce DAP, when compared to PBI with fluoroscopy-guided bile duct puncture. National DRLs of 4300 cGy·cm2 for initial PBIs and 1400 cGy·cm2 for follow-up PBIs are recommended. KEY POINTS: • DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. • PBI with US-guided bile duct puncture did not reduce DAP when compared to PBI with fluoroscopy-guided bile duct puncture. • DRLs of 4300 cGy·cm2for initial PBIs (establishing a transhepatic tract) and 1400 cGy·cm2for follow-up PBIs (transhepatic tract already established) are recommended.


Assuntos
Sistema Biliar/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Radiologia Intervencionista/estatística & dados numéricos , Adulto , Procedimentos Cirúrgicos do Sistema Biliar/métodos , Feminino , Fluoroscopia/estatística & dados numéricos , Alemanha , Humanos , Masculino , Radiografia Intervencionista/estatística & dados numéricos , Radiologia Intervencionista/normas , Valores de Referência , Estudos Retrospectivos , Stents
2.
Surg Endosc ; 29(11): 3205-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25588364

RESUMO

INTRODUCTION: Endoscopic dilation is the standard of care for stenoses of the cervical esophagus, but refractory strictures require some form of stenting. Most endoscopists avoid the placement of metal stents near the upper esophageal sphincter as they can cause major problems like severe cervical pain and globus sensation. We report our results with the use of biliary SEMS in the upper esophagus, which have a smaller diameter than regular esophageal stents and therefore exert less expansive force. MATERIAL AND METHODS: We retrospectively reviewed all patients in our center between July 2011 and June 2014 who received a biliary metal stent because of a refractory stricture in the cervical esophagus. We implanted biliary SEMS (Wallflex, Boston Scientific) with a diameter of 1 cm and length of 6-8 cm. Technical and clinical success, adverse events and duration of stenting were evaluated. RESULTS: Ten patients were treated with biliary SEMS in the upper esophagus. Strictures were located between 10 and 19 cm from incisor teeth. Stent placement was successful in all (10/10) patients. One stent had to be extracted because of pain and globus sensation. Apart from that stent tolerability was good. All remaining patients (9/9) reported improvement of dysphagia with a decrease in mean dysphagia score from 3.2 to 1.78. Mean duration of stenting was 68 days. DISCUSSION: Because of a high clinical success rate and good tolerability, biliary metal stents are a reasonable alternative for difficult strictures in the cervical esophagus, especially in the palliative setting.


Assuntos
Transtornos de Deglutição/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Estenose Esofágica/cirurgia , Hipofaringe/cirurgia , Stents , Idoso , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Estenose Esofágica/complicações , Estenose Esofágica/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA