1.
Phys Med ; 119: 103298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38309102

RESUMO

BACKGROUND: The dead-time loss reportedly degrades the accuracy of dosimetry using a gamma camera for targeted radionuclide therapy with Lu-177; therefore, the dead-time loss needs to be corrected. However, the correction is challenging. In this study, we propose a novel and simple method to shorten the apparent dead time rather than correcting it through experiments and Monte Carlo simulations. METHODS: An energy window of 208 keV ± 10 % is generally used for the imaging of Lu-177. Lower-energy gamma photons and X-rays of Lu-177 do not contribute to image formation but lead to dead-time losses. In our proposed method, a thin lead sheet was used to shield gamma photons and X-rays with energies lower than 208 keV, while detecting 208 keV gamma photons that penetrated the thin sheet. We measured and simulated the energy spectra and count rate characteristics of a clinical gamma camera system using a cylindrical phantom filled with a Lu-177 solution. Lead sheets of 1.0- and 0.5-mm thicknesses were used as thin shields, and the dead-time losses in tumour imaging with consumed Lu-177 were simulated. RESULTS: The apparent dead times with lead sheets of 1.0- and 0.5-mm thicknesses and without a lead sheet were 1.7, 1.9, and 5.8 µs for an energy window of 208 keV ± 10 %, respectively. The dead-time losses could be reduced from 10 % to 1.3 % using the 1.0-mm thick lead sheet in the simulated imaging of tumour. CONCLUSION: Our method is promising in clinical situations and studies on Lu-177 dosimetry for tumours.


Assuntos
Neoplasias , Radioisótopos , Humanos , Radioisótopos/uso terapêutico , Câmaras gama , Lutécio/uso terapêutico , Imagens de Fantasmas , Método de Monte Carlo
2.
Clin Neurol Neurosurg ; 236: 108110, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38171051

RESUMO

OBJECTIVE: This study aimed to analyze whether the development of donor vessels after combined revascularization surgery for moyamoya disease (MMD) is related to cerebral blood flow (CBF) changes. METHODS: We retrospectively reviewed the charts of 11 adult (12 hemispheres) and 13 pediatric (19 hemispheres) patients who underwent combined revascularization in our department. The total vessel cross-sectional area (TVA) was the sum of the cross-sectional areas of the superficial temporal, middle meningeal, and deep temporal arteries imaged using time-of-flight magnetic resonance angiography. The ipsilateral relative CBF (RCBF) on the brain surface in the craniotomy area was calculated by single-photon emission computed tomography. ΔTVA and ΔRCBF were defined as the preoperative and postoperative ratios of TVA and RCBF, and their correlations were analyzed in adult and pediatric patients. RESULTS: The TVA and RCBF showed a significant increase after surgery, regardless of the age group. However, there was no significant correlation between ΔTVA and ΔRCBF in either the adult or pediatric groups. While the adult group exhibited significantly higher ΔRCBF values compared to the pediatric group (p < 0.01, r = -0.44), the ΔTVA values were higher in the pediatric group compared to the adult group (p = 0.06). CONCLUSIONS: In the chronic phase after combined revascularization surgery for MMD, the development of measurable TVA of donor vessels does not necessarily correlate with an increase in CBF around the craniotomy area.


Assuntos
Revascularização Cerebral , Doença de Moyamoya , Adulto , Humanos , Criança , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Circulação Cerebrovascular/fisiologia
3.
Eur J Nucl Med Mol Imaging ; 51(4): 1060-1069, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38008728

RESUMO

PURPOSE: To examine whether adherence to a low-iodine diet (LID) enhances the therapeutic efficacy of radioiodine therapy (RAI) in Graves' hyperthyroidism (GH) in iodine-rich areas. METHODS: We retrospectively evaluated 185 patients with GH from Aichi (n = 114) and Hokkaido (n = 71) Prefectures. Patients aged ≥ 18 years with GH who underwent RAI between December 2012 and March 2022 were divided into subgroups based on pretreatment with anti-thyroid drug (ATD) or potassium iodide (KI). Patients were followed up with LID from 18 days (group A) or 7 days (group H) before RAI to 3 days after RAI. The dose of radioactive iodine 131 (131I) was adjusted to deliver > 100 Gy to the thyroid. The associations between urinary iodine concentration on UIC2 vs. 24hRU and UIC2 vs. the 1-year RAI success rate (SR) were investigated. RESULTS: Compared with UIC1, UIC2 was significantly decreased in all subgroups (P < 0.01). An inverse correlation between UIC2 and 24hRU was observed in the four groups; however, the difference was insignificant. The SR in groups A and H was 85% and 89%, respectively. Univariate analysis revealed no association between UIC2 and SR in each group. Additionally, stratification of the 185 patients into quartiles using UIC2 yielded no significant differences in SR (p = 0.79). CONCLUSIONS: LID sufficiently reduced UIC in patients undergoing RAI. Although a lower UIC2 may increase 24hRU, it did not increase the success of RAI. The benefit of LID in enhancing the efficacy of RAI in GH treatment remains uncertain.


Assuntos
Doença de Graves , Hipertireoidismo , Iodo , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo/efeitos adversos , Iodo/uso terapêutico , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/tratamento farmacológico , Doença de Graves/radioterapia , Doença de Graves/tratamento farmacológico , Dieta , Potássio , Resultado do Tratamento
4.
Radiat Prot Dosimetry ; 198(20): 1585-1597, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36321327

RESUMO

The International Commission on Radiological Protection (ICRP) 118th recommendation significantly reduced the threshold dose for cataract development from 8 to 0.5 Gy. Equivalent dose limits for the crystalline lenses of radiation workers are being reviewed for individual countries. Interventional radiology (IR) procedures are less invasive than surgery and have become widespread; however, there are concerns about exposure not only to patients but also to staff, including operators. Therefore, in this study, we used a human phantom to measure the near-lens dose of the operators (cardiologists, neurosurgeons and radiologists) and estimated the operator's lens dose for every major procedure in each clinical department; this was found to vary. Owing to the different imaging and fluoroscopy conditions of each department, and the varying ratio of fluoroscopy to radiography, it is necessary to measure the lens dose for each condition, as in this study. In addition, this study explains the differences between the protective effect of various safety equipment and the appropriate use of protective plates; it can contribute to the reduction of lens doses for operators.

5.
Neurosurg Rev ; 45(3): 2471-2480, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35319072

RESUMO

The purpose of this study was to examine the effects of combined revascularization for ischaemic-onset moyamoya disease (MMD) on cerebral haemodynamics by comparing cerebral blood flow (CBF) during the postoperative chronic phase with preoperative CBF. A retrospective cohort of 24 MMD patients (representing 31 surgeries) who received single photon emission computed tomography (SPECT) before and more than 6 months after surgery was investigated. The CBF value of each vascular territory was extracted from SPECT data, and the value relative to the ipsilateral cerebellar value (relative CBF, or RCBF) was calculated. The correlation between the revascularization effect and the proportional change in RCBF before and after surgery (calculated as post-RCBF/pre-RCBF ("post/pre-RCBF")) was analysed. Furthermore, the relationships between changes in neurological symptoms and post/pre-RCBF were investigated. Preoperative and postoperative mean RCBF values were 0.92 ± 0.15 and 0.96 ± 0.13 (p = 0.619) in the anterior cerebral artery territory, 0.99 ± 0.17 and 1.01 ± 0.17 (p = 0.598) in the middle cerebral artery territory and 1.15 ± 0.22 and 1.14 ± 0.19 (p = 0.062) in the posterior cerebral artery territory, respectively. No significant correlation was found between the revascularization score and post/pre-RCBF. The revascularization score and post/pre-RCBF were not significant predictors of worsening neurological symptoms postoperatively. No significant change in RCBF was observed in any vascular territory in the chronic phase after revascularization. Combined revascularization may assist in the redirection of blood flow from the internal to the external carotid system and contribute to CBF maintenance.


Assuntos
Revascularização Cerebral , Doença de Moyamoya , Revascularização Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Humanos , Doença de Moyamoya/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
6.
EJNMMI Phys ; 7(1): 6, 2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-31993828

RESUMO

BACKGROUND: Before radioiodine therapy for Graves' disease, the estimated thyroid-absorbed dose is calculated based on various clinical parameters. However, the actual accumulation of iodine in the thyroid during radioiodine therapy is not determined. We validated the feasibility of post-therapeutic image-based thyroid dosimetry through quantitative single-photon emission computed tomography (SPECT) imaging and thyroid biokinetics and expanding the Medical Internal Radiation Dose Committee's (MIRD) voxel dosimetry guidelines. METHODS: Forty-three patients with Graves' disease who underwent radioiodine therapy were chosen as subjects for this retrospective analysis. We acquired patients' SPECT images 24 h after oral administration. SPECT images were quantified using system volume sensitivity to calculate time-integrated activity coefficients on a voxel basis. Absorbed dose was obtained by convolving MIRD guideline voxel S values with time-integrated activity coefficients. To determine accuracy, we compared the results obtained using the post-therapeutic image-based absorbed-dose method (D̅image,PVC) with absorbed doses calculated using the method described by the European Association of Nuclear Medicine (pre-therapeutic method; DEANM). RESULTS: Using image-based dosimetry as post-therapeutic dosimetry, we visualized the local accumulation and absorbed dose distribution of iodine in the thyroid. Furthermore, we determined a strong correlation (Pearson's correlation coefficient = 0.89) between both dosimetries, using the regression equation: D̅image,PVC = 0.94 × DEANM + 1.35. CONCLUSION: Post-therapeutic image-based doses absorbed in the thyroid resembled those of pre-therapeutic EANM method-based absorbed doses. Additionally, the post-therapeutic image-based method had the advantage of visualizing thyroid iodine distribution, thus determining local dose distributions at the time of treatment. From these points, we propose that post-therapeutic image-based dosimetry could provide an alternative to standard pre-therapeutic dosimetry to evaluate dose response.

7.
Sci Rep ; 8(1): 10976, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-30030499

RESUMO

Ra-223 has recently been introduced to alpha radionuclide therapy. According to the decay scheme of Ra-223, an inert gas, Rn-219 is released from patients during alpha radionuclide therapy and its daughter radionuclides may accumulate around the patient. However, the concentration of these radon daughters during alpha radionuclide therapy was not obvious. Here, we first detected the radon daughters of Rn-219 around patients during alpha radionuclide therapy. While the Ra-223-administered patients were in a room for ~1.5 hours, the radon daughter concentration increased to 4 to 5 times higher than without the patients. When the patients were in the room, the energy spectra of the alpha particles in the air showed the peak of the radon daughter of Rn-219, Bi-211 (6.6 MeV), which was different from that without the patients. We conclude that the daughter radionuclides of Rn-219 are accumulated around the patient, and the concentration was higher than that of the natural radon daughters. However, the increase in levels of alpha emitters, while detectable, is lower than the daily variations and thus is likely not a source of concern for radiation exposure.


Assuntos
Poluentes Radioativos do Ar/análise , Partículas alfa/efeitos adversos , Radioterapia/efeitos adversos , Rádio (Elemento)/uso terapêutico , Partículas alfa/uso terapêutico , Humanos , Exposição à Radiação , Rádio (Elemento)/análise , Produtos de Decaimento de Radônio/análise
8.
Ann Nucl Med ; 32(5): 348-362, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29667143

RESUMO

OBJECTIVE: Recent many studies have shown that whole body "diffusion-weighted imaging with background body signal suppression" (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma. METHODS: Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 ± 2.0 years old) who underwent both 18F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18F-FDG PET/CT and whole-body DWIBS were compared using McNemer's test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher's exact test. RESULTS: The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of 18F-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis. CONCLUSION: The specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of 18F-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of 18F-FDG PET/CT. DWIBS should be carefully used for cancer staging in children because of its high incidence of false-positive findings in skeletons.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Metástase Linfática/diagnóstico por imagem , Neuroblastoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Corporal Total/métodos , 3-Iodobenzilguanidina , Neoplasias Ósseas/secundário , Osso e Ossos/diagnóstico por imagem , Pré-Escolar , Reações Falso-Positivas , Feminino , Fluordesoxiglucose F18 , Humanos , Lactente , Linfonodos/diagnóstico por imagem , Masculino , Imagem Multimodal/métodos , Neuroblastoma/patologia , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Medronato de Tecnécio Tc 99m
9.
Br J Radiol ; 87(1034): 20130444, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24297809

RESUMO

OBJECTIVE: We compared the efficacies of ¹8F-fluoride positron emission tomography (¹8F-fluoride PET)/CT, ¹8F-fludeoxyglucose PET (¹8F-FDG PET)/CT, and 99mTc bone scintigraphy [planar and single photon emission CT (SPECT)] for the detection of bone metastases in patients with differentiated thyroid carcinoma (DTC). METHODS: We examined 11 patients (8 females and 3 males; mean age 6 standard deviation, 61.968.7 years) with DTC who had been suspected of having bone metastases after total thyroidectomy and were hospitalized to be given ¹³¹I therapy. Bone metastases were verified either when positive findings were obtained on both ¹³¹I scintigraphy and CT or when MRI findings were positive if MRI was performed. RESULTS: Metastases were confirmed in 24 (13.6%) of 176 bone segments in 9 (81.8%) of the 11 patients. The sensitivities of ¹8F-fluoride PET/CT and 99mTc bone scintigraphy (SPECT) were significantly higher than those of ¹8F-FDG PET/CT and 99mTc bone scintigraphy (planar) (p,0.05). The accuracies of ¹8F-fluoride PET/CT and mTc bone scintigraphy (SPECT) were significantly higher than that of 99mTc bone scintigraphy (planar) (p,0.05). CONCLUSION: The sensitivity and accuracy of ¹8F-fluoride PET/CT for the detection of bone metastases of DTC are significantly higher than those of 99mTc bone scintigraphy (planar). However, the sensitivity and accuracy of 99mTc bone scintigraphy (planar) are improved near to those of ¹8F-fluoride PET/CT when SPECT is added to a planar scan. The sensitivity of ¹8F-FDG PET/CT is significantly lower than that of 18F-fluoride PET/CT or 99mTc bone scintigraphy (SPECT).


Assuntos
Adenocarcinoma Folicular/diagnóstico , Adenocarcinoma Folicular/secundário , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/secundário , Carcinoma Papilar/diagnóstico , Carcinoma Papilar/secundário , Neoplasias da Glândula Tireoide , Adenocarcinoma Folicular/cirurgia , Idoso , Osso e Ossos/diagnóstico por imagem , Carcinoma Papilar/cirurgia , Diagnóstico Diferencial , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Projetos Piloto , Tomografia por Emissão de Pósitrons/métodos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X/métodos
10.
Int J Comput Assist Radiol Surg ; 8(4): 621-33, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23263885

RESUMO

PURPOSE: Liquid crystal display (LCD) of mammograms provides soft-copy results that differ in conventional and phase contrast mammography (PCM). PCM potentially offers the highest quality of sharpness and graininess, an edge emphasis effect on the object, and the highest image resolution. However, when the image is displayed on an LCD, the resolution depends on the pixel pitch and the PCM image data must be diminished. We investigated the observed effect on spatial resolution and contrast when conventional or phase contrast mammograms are viewed on an LCD. METHODS: Using the tissue-equivalent phantom (Model 1011A), a conventional mammogram and a magnification radiography image were obtained with a PCM system. This phantom contains simulated fibers, microcalcifications, and masses. The PCM image was reduced 1/1.75 to render it consistent with life size mammography using the nearest neighbor, bilinear, and bicubic interpolation methods. The images were displayed on a five million (5M)-pixel LCD with 100 % magnification. Ten mammography technicians observed the reduction images displayed on LCDs and reported their results. RESULTS: In the detectability of the microcalcifications, there was no significant difference between conventional mammograms and reduced PCM images. Regarding fibers and masses, detectability using reduced images was higher than those of conventional images. The detectability using images reduced by the nearest-neighbor method was lower than those of images reduced by two other interpolation methods. Bilinear interpolation was affected by the smoothing effect, while CNR was increased. In addition, since the noise of PCM image was reduced by an air gap effect, high detectability of key image features was found. CONCLUSIONS: Soft-copy display of phase-contrast mammograms is feasible with LCDs, while detectability of fibers and masses was best with bilinear interpolation and use of an air gap.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Apresentação de Dados , Mamografia/métodos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Feminino , Humanos , Cristais Líquidos