1.
Phys Med Biol ; 68(16)2023 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-37327792

RESUMO

Objective. Cerebral CT perfusion (CTP) imaging is most commonly used to diagnose acute ischaemic stroke and support treatment decisions. Shortening CTP scan duration is desirable to reduce the accumulated radiation dose and the risk of patient head movement. In this study, we present a novel application of a stochastic adversarial video prediction approach to reduce CTP imaging acquisition time.Approach. A variational autoencoder and generative adversarial network (VAE-GAN) were implemented in a recurrent framework in three scenarios: to predict the last 8 (24 s), 13 (31.5 s) and 18 (39 s) image frames of the CTP acquisition from the first 25 (36 s), 20 (28.5 s) and 15 (21 s) acquired frames, respectively. The model was trained using 65 stroke cases and tested on 10 unseen cases. Predicted frames were assessed against ground-truth in terms of image quality and haemodynamic maps, bolus shape characteristics and volumetric analysis of lesions.Main results. In all three prediction scenarios, the mean percentage error between the area, full-width-at-half-maximum and maximum enhancement of the predicted and ground-truth bolus curve was less than 4 ± 4%. The best peak signal-to-noise ratio and structural similarity of predicted haemodynamic maps was obtained for cerebral blood volume followed (in order) by cerebral blood flow, mean transit time and time to peak. For the 3 prediction scenarios, average volumetric error of the lesion was overestimated by 7%-15%, 11%-28% and 7%-22% for the infarct, penumbra and hypo-perfused regions, respectively, and the corresponding spatial agreement for these regions was 67%-76%, 76%-86% and 83%-92%.Significance. This study suggests that a recurrent VAE-GAN could potentially be used to predict a portion of CTP frames from truncated acquisitions, preserving the majority of clinical content in the images, and potentially reducing the scan duration and radiation dose simultaneously by 65% and 54.5%, respectively.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Redes Neurais de Computação , Imagem de Perfusão/métodos , Circulação Cerebrovascular/fisiologia , Doses de Radiação
2.
Quant Imaging Med Surg ; 12(1): 439-456, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34993092

RESUMO

BACKGROUND: Computed tomography perfusion imaging is commonly used for the rapid assessment of patients presenting with symptoms of acute stroke. Maps of perfusion parameters, such as cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) derived from the perfusion scan data, provide crucial information for stroke diagnosis and treatment decisions. Most CT scanners use singular value decomposition (SVD)-based methods to calculate these parameters. However, some known problems are associated with conventional methods. METHODS: In this work, we propose a Bayesian inference algorithm, which can derive both the perfusion parameters and their uncertainties. We apply the variational technique to the inference, which then becomes an expectation-maximization problem. The probability distribution (with Gaussian mean and variance) of each estimated parameter can be obtained, and the coefficient of variation is used to indicate the uncertainty. We perform evaluations using both simulations and patient studies. RESULTS: In a simulation, we show that the proposed method has much less bias than conventional methods. Then, in separate simulations, we apply the proposed method to evaluate the impacts of various scan conditions, i.e., with different frame intervals, truncated measurement, or motion, on the parameter estimate. In one patient study, the method produced CBF and MTT maps indicating an ischemic lesion consistent with the radiologist's report. In a second patient study affected by patient movement, we showed the feasibility of applying the proposed method to motion corrected data. CONCLUSIONS: The proposed method can be used to evaluate confidence in parameter estimation and the scan protocol design. More clinical evaluation is required to fully test the proposed method.

3.
Phys Med Biol ; 66(7)2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33621965

RESUMO

Dose reduction in cerebral CT perfusion (CTP) imaging is desirable but is accompanied by an increase in noise that can compromise the image quality and the accuracy of image-based haemodynamic modelling used for clinical decision support in acute ischaemic stroke. The few reported methods aimed at denoising low-dose CTP images lack practicality by considering only small sections of the brain or being computationally expensive. Moreover, the prediction of infarct and penumbra size and location-the chief means of decision support for treatment options-from denoised data has not been explored using these approaches. In this work, we present the first application of a 3D generative adversarial network (3D GAN) for predicting normal-dose CTP data from low-dose CTP data. Feasibility of the approach was tested using real data from 30 acute ischaemic stroke patients in conjunction with low dose simulation. The 3D GAN model was applied to 643voxel patches extracted from two different configurations of the CTP data-frame-based and stacked. The method led to whole-brain denoised data being generated for haemodynamic modelling within 90 s. Accuracy of the method was evaluated using standard image quality metrics and the extent to which the clinical content and lesion characteristics of the denoised CTP data were preserved. Results showed an average improvement of 5.15-5.32 dB PSNR and 0.025-0.033 structural similarity index (SSIM) for CTP images and 2.66-3.95 dB PSNR and 0.036-0.067 SSIM for functional maps at 50% and 25% of normal dose using GAN model in conjunction with a stacked data regime for image synthesis. Consequently, the average lesion volumetric error reduced significantly (p-value <0.05) by 18%-29% and dice coefficient improved significantly by 15%-22%. We conclude that GAN-based denoising is a promising practical approach for reducing radiation dose in CTP studies and improving lesion characterisation.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Encéfalo/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Redução da Medicação , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão , Tomografia Computadorizada por Raios X/métodos
4.
Phys Med Biol ; 66(6): 06RM01, 2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33339012

RESUMO

Positron emission tomography (PET) plays an increasingly important role in research and clinical applications, catalysed by remarkable technical advances and a growing appreciation of the need for reliable, sensitive biomarkers of human function in health and disease. Over the last 30 years, a large amount of the physics and engineering effort in PET has been motivated by the dominant clinical application during that period, oncology. This has led to important developments such as PET/CT, whole-body PET, 3D PET, accelerated statistical image reconstruction, and time-of-flight PET. Despite impressive improvements in image quality as a result of these advances, the emphasis on static, semi-quantitative 'hot spot' imaging for oncologic applications has meant that the capability of PET to quantify biologically relevant parameters based on tracer kinetics has not been fully exploited. More recent advances, such as PET/MR and total-body PET, have opened up the ability to address a vast range of new research questions, from which a future expansion of applications and radiotracers appears highly likely. Many of these new applications and tracers will, at least initially, require quantitative analyses that more fully exploit the exquisite sensitivity of PET and the tracer principle on which it is based. It is also expected that they will require more sophisticated quantitative analysis methods than those that are currently available. At the same time, artificial intelligence is revolutionizing data analysis and impacting the relationship between the statistical quality of the acquired data and the information we can extract from the data. In this roadmap, leaders of the key sub-disciplines of the field identify the challenges and opportunities to be addressed over the next ten years that will enable PET to realise its full quantitative potential, initially in research laboratories and, ultimately, in clinical practice.


Assuntos
Inteligência Artificial , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/tendências , História do Século XX , História do Século XXI , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Cinética , Oncologia/métodos , Oncologia/tendências , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/história , Prognóstico , Compostos Radiofarmacêuticos , Biologia de Sistemas , Tomografia Computadorizada por Raios X
5.
Breast J ; 25(2): 296-300, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30706574

RESUMO

A radiation dose survey has been undertaken involving 256 patients to investigate the dosimetric impact of breast tomosynthesis screening by employing different breast densities estimated by the Dance model, 50-50 breast model, and patient-specific density software: Volpara. Mean glandular dose (MGD) based on the Dance model provided the most realistic dose estimate with an average difference of -3.3 ± 4.8% from the patient-specific estimation. Average differences of -8.2 ± 6.5% and -7.3 ± 4.7% were observed for the 50-50 breast model and console MGD, respectively. We conclude that the Dance model should be used for dose calculations in radiation dose surveys and establishing diagnostic reference levels (DRL).


Assuntos
Densidade da Mama , Mamografia/métodos , Doses de Radiação , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Modelos Biológicos , Radiometria/métodos
6.
Phys Med Biol ; 63(10): 105018, 2018 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-29637899

RESUMO

Motion-compensated brain imaging can dramatically reduce the artifacts and quantitative degradation associated with voluntary and involuntary subject head motion during positron emission tomography (PET), single photon emission computed tomography (SPECT) and computed tomography (CT). However, motion-compensated imaging protocols are not in widespread clinical use for these modalities. A key reason for this seems to be the lack of a practical motion tracking technology that allows for smooth and reliable integration of motion-compensated imaging protocols in the clinical setting. We seek to address this problem by investigating the feasibility of a highly versatile optical motion tracking method for PET, SPECT and CT geometries. The method requires no attached markers, relying exclusively on the detection and matching of distinctive facial features. We studied the accuracy of this method in 16 volunteers in a mock imaging scenario by comparing the estimated motion with an accurate marker-based method used in applications such as image guided surgery. A range of techniques to optimize performance of the method were also studied. Our results show that the markerless motion tracking method is highly accurate (<2 mm discrepancy against a benchmarking system) on an ethnically diverse range of subjects and, moreover, exhibits lower jitter and estimation of motion over a greater range than some marker-based methods. Our optimization tests indicate that the basic pose estimation algorithm is very robust but generally benefits from rudimentary background masking. Further marginal gains in accuracy can be achieved by accounting for non-rigid motion of features. Efficiency gains can be achieved by capping the number of features used for pose estimation provided that these features adequately sample the range of head motion encountered in the study. These proof-of-principle data suggest that markerless motion tracking is amenable to motion-compensated brain imaging and holds good promise for a practical implementation in clinical PET, SPECT and CT systems.


Assuntos
Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Movimento , Neuroimagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
7.
J Nucl Med ; 59(9): 1480-1486, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29439015

RESUMO

Respiratory motion degrades the detection and quantification capabilities of PET/CT imaging. Moreover, mismatch between a fast helical CT image and a time-averaged PET image due to respiratory motion results in additional attenuation correction artifacts and inaccurate localization. Current motion compensation approaches typically have 3 limitations: the mismatch among respiration-gated PET images and the CT attenuation correction (CTAC) map can introduce artifacts in the gated PET reconstructions that can subsequently affect the accuracy of the motion estimation; sinogram-based correction approaches do not correct for intragate motion due to intracycle and intercycle breathing variations; and the mismatch between the PET motion compensation reference gate and the CT image can cause an additional CT-mismatch artifact. In this study, we established a motion correction framework to address these limitations. Methods: In the proposed framework, the combined emission-transmission reconstruction algorithm was used for phase-matched gated PET reconstructions to facilitate the motion model building. An event-by-event nonrigid respiratory motion compensation method with correlations between internal organ motion and external respiratory signals was used to correct both intracycle and intercycle breathing variations. The PET reference gate was automatically determined by a newly proposed CT-matching algorithm. We applied the new framework to 13 human datasets with 3 different radiotracers and 323 lesions and compared its performance with CTAC and non-attenuation correction (NAC) approaches. Validation using 4-dimensional CT was performed for one lung cancer dataset. Results: For the 10 18F-FDG studies, the proposed method outperformed (P < 0.006) both the CTAC and the NAC methods in terms of region-of-interest-based SUVmean, SUVmax, and SUV ratio improvements over no motion correction (SUVmean: 19.9% vs. 14.0% vs. 13.2%; SUVmax: 15.5% vs. 10.8% vs. 10.6%; SUV ratio: 24.1% vs. 17.6% vs. 16.2%, for the proposed, CTAC, and NAC methods, respectively). The proposed method increased SUV ratios over no motion correction for 94.4% of lesions, compared with 84.8% and 86.4% using the CTAC and NAC methods, respectively. For the 2 18F-fluoropropyl-(+)-dihydrotetrabenazine studies, the proposed method reduced the CT-mismatch artifacts in the lower lung where the CTAC approach failed and maintained the quantification accuracy of bone marrow where the NAC approach failed. For the 18F-FMISO study, the proposed method outperformed both the CTAC and the NAC methods in terms of motion estimation accuracy at 2 lung lesion locations. Conclusion: The proposed PET/CT respiratory event-by-event motion-correction framework with motion information derived from matched attenuation-corrected PET data provides image quality superior to that of the CTAC and NAC methods for multiple tracers.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Movimento , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Respiração , Técnicas de Imagem de Sincronização Respiratória , Tomografia Computadorizada Quadridimensional , Humanos
8.
IEEE Trans Med Imaging ; 33(3): 636-50, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24595339

RESUMO

Positron emission tomography (PET) images usually suffer from poor signal-to-noise ratio (SNR) due to the high level of noise and low spatial resolution, which adversely affect its performance for lesion detection and quantification. The complementary information present in high-resolution anatomical images from multi-modality imaging systems could potentially be used to improve the ability to detect and/or quantify lesions. However, previous methods that use anatomical priors usually require matched organ/lesion boundaries. In this study, we investigated the use of anatomical information to suppress noise in PET images while preserving both quantitative accuracy and the amplitude of prominent signals that do not have corresponding boundaries on computerized tomography (CT). The proposed approach was realized through a postreconstruction filter based on the nonlocal means (NLM) filter, which reduces noise by computing the weighted average of voxels based on the similarity measurement between patches of voxels within the image. Anatomical knowledge obtained from CT was incorporated to constrain the similarity measurement within a subset of voxels. In contrast to other methods that use anatomical priors, the actual number of neighboring voxels and weights used for smoothing were determined from a robust measurement on PET images within the subset. Thus, the proposed approach can be robust to signal mismatches between PET and CT. A 3-D search scheme was also investigated for the volumetric PET/CT data. The proposed anatomically guided median nonlocal means filter (AMNLM) was first evaluated using a computer phantom and a physical phantom to simulate realistic but challenging situations where small lesions are located in homogeneous regions, which can be detected on PET but not on CT. The proposed method was further assessed with a clinical study of a patient with lung lesions. The performance of the proposed method was compared to Gaussian, edge-preserving bilateral and NLM filters, as well as median nonlocal means (MNLM) filtering without an anatomical prior. The proposed AMNLM method yielded improved lesion contrast and SNR compared with other methods even with imperfect anatomical knowledge, such as missing lesion boundaries and mismatched organ boundaries.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Razão Sinal-Ruído , Tórax/diagnóstico por imagem
9.
Phys Med Biol ; 53(20): 5845-57, 2008 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-18827318

RESUMO

We have tested the performance of an Optotrak Certus system, which optically tracks multiple markers, in both position and time. To do this, we have developed custom code which enables a range of testing protocols, and make this code available to the community. We find that the Certus' positional accuracy is very high, around 20 microm at a distance of 2.8 m. In contrast, we find that its timing accuracy is typically no better than around 5-10% for typical data rates, whether one is using an ethernet connection or a dedicated SCSI link from the system to a host computer. However, with our code we are able to attach very accurate timestamps to the data frames, and in cases where regularly-spaced data are not an absolute requirement, this will be more than adequate.


Assuntos
Diagnóstico por Imagem/instrumentação , Aumento da Imagem/instrumentação , Movimento (Física) , Dispositivos Ópticos , Radioterapia/instrumentação , Benchmarking , Desenho de Equipamento , Análise de Falha de Equipamento
10.
J Nucl Med ; 49(5): 814-22, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18413395

RESUMO

UNLABELLED: The translocator protein (18 kDa) (TSPO), formerly known as the peripheral benzodiazepine receptor, is dramatically upregulated under pathologic conditions. Activated microglia are the main cell type expressing the TSPO at sites of central nervous system pathology. Radioligands for the TSPO can therefore measure active disease in the brain. This article details the synthesis, radiofluorination, and pharmacologic evaluation of a new TSPO-specific pyrazolopyrimidine, DPA-714. METHODS: The affinity of DPA-714 for the TSPO was measured in rat kidney membranes with (3)H-PK11195. The in vitro functional activity of DPA-714 was measured in a steroidogenic assay in which the ability of DPA-714 to increase pregnenolone synthesis was measured with rat C6 glioma cells. The radiofluorination of DPA-714 was achieved by nucleophilic (18)F-fluoride displacement of the tosylate precursor. (18)F-DPA-714 was assessed in rats harboring unilateral quinolinic acid (QA) lesions. In addition, pretreatment experiments were performed with PK11195 (5 mg/kg), DPA-714 (1 mg/kg), and DPA-713 (1 mg/kg). The in vivo binding and biodistribution of (18)F-DPA-714 were determined in a baboon with PET. Experiments involving presaturation with PK11195 (1.5 mg/kg) and displacement with DPA-714 (1 mg/kg) were conducted to evaluate the specificity of radioligand binding. RESULTS: In vitro binding studies revealed that DPA-714 displayed a high affinity for the TSPO (dissociation constant, 7.0 nM). DPA-714 stimulated pregnenolone synthesis at levels 80% above the baseline. (18)F-DPA-714 was prepared at a 16% radiochemical yield and a specific activity of 270 GBq/mumol. In rats harboring unilateral QA lesions, an 8-fold-higher level of uptake of (18)F-DPA-714 was observed in the ipsilateral striatum than in the contralateral striatum. Uptake in the ipsilateral striatum was shown to be selective because it was inhibited to the level in the contralateral striatum in the presence of PK11195, nonlabeled DPA-714, or DPA-713. PET studies demonstrated rapid penetration and good retention of (18)F-DPA-714 in the baboon brain. Pretreatment with PK11195 effectively inhibited the uptake of (18)F-DPA-714 in the whole brain, indicating its selective binding to the TSPO. The injection of nonlabeled DPA-714 20 min after the injection of (18)F-DPA-714 resulted in radioligand washout, demonstrating the reversibility of (18)F-DPA-714 binding. CONCLUSION: (18)F-DPA-714 is a specific radioligand for the TSPO, displaying promising in vivo properties and thus warranting further investigation.


Assuntos
Proteínas de Transporte/metabolismo , Halogenação , Pirazóis/síntese química , Pirazóis/farmacologia , Pirimidinas/síntese química , Pirimidinas/farmacologia , Receptores de GABA-A/metabolismo , Animais , Radioisótopos de Flúor , Ligantes , Papio hamadryas/metabolismo , Pregnenolona/biossíntese , Pirazóis/química , Pirazóis/farmacocinética , Pirimidinas/química , Pirimidinas/farmacocinética , Radioquímica , Ratos , Especificidade por Substrato , Distribuição Tecidual