Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Rev Esp Enferm Dig ; 116(10): 526-531, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38767020

RESUMO

INTRODUCTION: percutaneous endoscopic gastrostomy (PEG) is considered as a safe and effective method for nutritional support in patients with malnutrition and swallowing impairment with an estimated survival of over two months. Some indications, such as advanced cognitive decline, contraindicate the technique. MATERIALS AND METHODS: all patients who underwent PEG placement between January 2001 and May 2019 were included. Clinical data, indication, complications, and mortality were retrospectively analyzed. RESULTS: a total of 648 patients (46.5 % male, mean age 70 ± 18.5 years) were included. The most common indications for PEG were advanced cognitive decline (31.5 %) and cerebrovascular disease (18.8 %). The mean follow-up was 12.07 months (IQR 3.27-34.73); 39.5 % of patients experienced complications (systemic 17.9 %, local 28.5 %). The most frequent were bronchoaspiration (9.7 %) and rupture/dysfunction (13.9 %), respectively. The presence of early complications (HR 1.63 [1.20-2.21]) and age (HR 1.02 [1.01-1.02]) was associated with shorter survival time, while female sex was a protective factor (HR 0.78 [0.66-0.94]). CONCLUSIONS: PEG is not without complications, with 39.5 % of patients experiencing them. Patients with early complications, male sex and older age have lower survival following PEG placement.


Assuntos
Gastrostomia , Complicações Pós-Operatórias , Humanos , Masculino , Feminino , Gastrostomia/efeitos adversos , Gastrostomia/métodos , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Nutrição Enteral/métodos , Desnutrição/etiologia , Gastroscopia
2.
Rev Esp Enferm Dig ; 116(6): 305-311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38214165

RESUMO

INTRODUCTION: the risk of hepatocellular carcinoma (HCC) after eradication of the hepatitis C virus (HCV) is highly variable in patients with advanced fibrosis (F3). Long-term surveillance for HCC after sustained virological response (SVR) is controversial in these patients. The objective of this study was to describe the post-SVR follow-up in clinical practice in patients with F3 and determine the predictive factors for the development of HCC. PATIENTS AND METHODS: a multicenter, observational and retrospective study was performed, which included HCV-monoinfected patients with F3 fibrosis determined by transient elastography who achieved SVR between 2015 and 2022, with follow-up until May 2023. Clinical-demographic, laboratory, elastography, and ultrasound variables were recorded before and after treatment. A descriptive and inferential analysis, Cox regression analysis and survival analysis were carried out with the R statistical software. RESULTS: two hundred and nineteen patients were included in the study (65.3 % males, median age 57 years), and 175 (79.9 %) received ultrasound screening after SVR for 62 (6-90) months. The prescribing service was the only independent variable related to performing ultrasound surveillance (p = 0.004). Eight patients developed HCC. In multivariate analysis adjusted for sex, age, presence of diabetes and alcohol consumption, a post-SVR FIB-4 ≥ 3.25 was associated with a 12-fold increase in HCC risk. The cumulative probability of HCC was higher in the group of patients with FIB-4 ≥ 3.25 after SVR (p < 0.001). CONCLUSION: post-SVR follow-up of patients with F3 fibrosis is variable in clinical practice. Using the FIB-4 after SVR allows us to identify those patients with a higher risk of HCC who benefit from biannual ultrasound screening.


Assuntos
Carcinoma Hepatocelular , Cirrose Hepática , Neoplasias Hepáticas , Humanos , Masculino , Feminino , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/etiologia , Pessoa de Meia-Idade , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/etiologia , Estudos Retrospectivos , Cirrose Hepática/diagnóstico por imagem , Idoso , Hepatite C Crônica/complicações , Resposta Viral Sustentada , Adulto , Fatores de Risco , Antivirais/uso terapêutico , Técnicas de Imagem por Elasticidade , Ultrassonografia , Seguimentos
3.
Rev Esp Enferm Dig ; 114(11): 692, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35607925

RESUMO

We present the case of a 37-year-old Caucasian woman, with no history of interest, who came to the emergency room for an occlusive condition of 24 hours' evolution. The patient reported a weight loss of 12 kg in the last month, as well as the appearance of a lump in the left breast in the last week. A chest-abdominal CT scan revealed multiple solid-appearing nodules in the left breast, a metastatic liver lesion, and a tumor-like mass in the right iliac fossa measuring 90x60 mm. A biopsy of the breast lesion revealed a diffuse architectural pattern with destruction of the parenchyma and irregular medium-large cellularity with intense and diffuse expression of CD20, CD10 and Bcl6 and a proliferative index of practically 100%, consistent with lymphoma. Burkitt stage IV. Intestinal obstruction constitutes about 15% of hospital admissions for abdominal pain, representing a significant cause of hospital mortality. Although the most common causes of small bowel obstruction are benign (adhesions, hernias), intraluminal lesions such as inflammatory bowel disease or neoplasms are well-established causes associated with this clinical picture. Lymphomas constitute 25% of cases of intestinal obstruction of neoplastic origin; among them, Burkitt lymphoma is a rare type of B-cell lymphoma characterized by rapid and aggressive cell growth, the most common initial involvement of which is located at the abdominal and extra-nodal level.


Assuntos
Linfoma de Burkitt , Obstrução Intestinal , Linfoma de Células B , Feminino , Humanos , Adulto , Linfoma de Burkitt/complicações , Linfoma de Burkitt/diagnóstico por imagem , Linfoma de Células B/patologia , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Dor Abdominal/etiologia
4.
J Chromatogr A ; 1514: 110-119, 2017 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-28756892

RESUMO

Chemical signaling is a widespread mode of communication among living organisms that is used to establish social organization, territoriality and/or for mate choice. In lizards, femoral and precloacal glands are important sources of chemical signals. These glands protrude chemical secretions used to mark territories and also, to provide valuable information from the bearer to other individuals. Ecologists have studied these chemical secretions for decades in order to increase the knowledge of chemical communication in lizards. Although several studies have focused on the chemical analysis of these secretions, there is a lack of faster, more sensitive and more selective analytical methodologies for their study. In this work a new GC coupled to tandem triple quadrupole MS (GC-QqQ (MS/MS)) methodology is developed and proposed for the target study of 12 relevant compounds often found in lizard secretions (i.e. 1-hexadecanol, palmitic acid, 1-octadecanol, oleic acid, stearic acid, 1-tetracosanol, squalene, cholesta-3,5-diene, α-tocopherol, cholesterol, ergosterol and campesterol). The method baseline-separated the analytes in less than 7min, with instrumental limits of detection ranging from 0.04 to 6.0ng/mL. It was possible to identify differences in the composition of the samples from the lizards analyzed, which depended on the species, the habitat occupied and the diet of the individuals. Moreover, α-tocopherol has been determined for the first time in a lizard species, which was thought to lack its expression in chemical secretions. Globally, the methodology has been proven to be a valuable alternative to other published methods with important improvements in terms of analysis time, sensitivity, and selectivity.


Assuntos
Glândulas Exócrinas/química , Cromatografia Gasosa-Espectrometria de Massas , Lagartos/metabolismo , Feromônios/análise , Animais , Ecossistema , Glândulas Exócrinas/metabolismo , Limite de Detecção , Feromônios/química , Espectrometria de Massas em Tandem
5.
J Agric Food Chem ; 64(38): 7265-74, 2016 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-27600263

RESUMO

This paper reports on the optimization, characterization, and applicability of gas chromatography coupled to triple-quadrupole tandem mass spectrometry (GC-QqQ(MS/MS)) for the determination of 14 polybrominated diphenylethers (PBDEs) and 2 emerging brominated flame retardants, 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE) and decabromodiphenylethane (DBDPE), in functional food samples. The method showed satisfactory precision and linearity with instrumental limits of detection (iLODs) ranging from 0.12 to 7.1 pg, for tri- to octa-BDEs and BTBPE, and equal to 51 and 20 pg for BDE-209 and DBDPE, respectively. The highest ΣBFR concentrations were found in fish oil supplements (924 pg/g fresh weight, fw), followed by biscuits (90 pg/g fw), vegetable oil supplements (46 pg/g fw), chicken eggs (45 pg/g fw), cow's milk (7.7 pg/g fw), and soy products (1.6 pg/g fw). BDE-47, BDE-99, and DBDPE were the most abundant compounds. Foodstuffs enriched with omega-3 presented concentrations similar to or even lower than those of conventional foods commercialized in Spain since 2000.


Assuntos
Ácidos Graxos Ômega-3/análise , Retardadores de Chama/análise , Alimentos Fortificados , Alimento Funcional/análise , Éteres Difenil Halogenados/análise , Animais , Bromobenzenos/análise , Cromatografia Gasosa , Ovos/análise , Óleos de Peixe/análise , Análise de Alimentos , Contaminação de Alimentos/análise , Halogenação , Limite de Detecção , Leite/química , Óleos de Plantas/química , Controle de Qualidade , Espanha , Espectrometria de Massas em Tandem
6.
Anal Bioanal Chem ; 408(2): 449-59, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26554601

RESUMO

A fast method for the screening and quantification of hexabromocyclododecane (sum of all isomers) by gas chromatography using a triple quadrupole mass spectrometer with atmospheric pressure chemical ionization (GC-APCI-QqQ) is proposed. This novel procedure makes use of the soft atmospheric pressure chemical ionization source, which results in less fragmentation of the analyte than by conventional electron impact (EI) and chemical ionization (CI) sources, favoring the formation of the [M - Br](+) ion and, thus, enhancing sensitivity and selectivity. Detection was based on the consecutive loses of HBr from the [M - Br](+) ion to form the specific [M - H5Br6](+) and [M - H4Br5](+) ions, which were selected as quantitation (Q) and qualification (q) transitions, respectively. Parameters affecting ionization and MS/MS detection were studied. Method performance was also evaluated; calibration curves were found linear from 1 pg/µL to 100 pg/µL for the total HBCD concentration; instrumental detection limit was estimated to be 0.10 pg/µL; repeatability and reproducibility, expressed as relative standard deviation, were better than 7% in both cases. The application to different real samples [polyurethane foam disks (PUFs), food, and marine samples] pointed out a rapid way to identify and allow quantification of this compound together with a number of polybrominated diphenyl ethers (BDE congeners 28, 47, 66, 85, 99, 100, 153, 154, 183, 184, 191, 196, 197, and 209) and two other novel brominated flame retardants [i.e., decabromodiphenyl ethane (DBDPE) and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE)] because of their presence in the same fraction when performing the usual sample treatment.


Assuntos
Retardadores de Chama/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrocarbonetos Bromados/química , Animais , Organismos Aquáticos/química , Decapodiformes , Golfinhos , Poluentes Ambientais/química , Peixes , Humanos , Leite Humano/química , Estrutura Molecular , Espectrometria de Massas em Tandem/métodos
7.
Anal Chem ; 87(19): 9892-9, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26354040

RESUMO

The analysis of brominated flame retardants (BFRs) commonly relies on the use of gas chromatography coupled to mass spectrometry (GC-MS) operating in electron ionization (EI) and electron capture negative ionization (ECNI) modes using quadrupole, triple quadrupole, ion trap, and magnetic sector analyzers. However, these brominated contaminants are examples of compounds for which a soft and robust ionization technique might be favorable since they show high fragmentation in EI and low specificity in ECNI. In addition, the low limits of quantification (0.01 ng/g) required by European Commission Recommendation 2014/118/EU on the monitoring of traces of BFRs in food put stress on the use of highly sensitive techniques/methods. In this work, a new approach for the extremely sensitive determination of BFRs taking profit of the potential of atmospheric pressure chemical ionization (APCI) combined with GC and triple quadrupole (QqQ) mass analyzer is proposed. The objective was to explore the potential of this approach for the BFRs determination in samples at pg/g levels, taking marine samples and a cream sample as a model. Ionization and fragmentation behavior of 14 PBDEs (congeners 28, 47, 66, 85, 99, 100, 153, 154, 183, 184, 191, 196, 197, and 209) and two novel BFRs, decabromodiphenyl ethane (DBDPE) and 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), in the GC-APCI-MS system has been investigated. The formation of highly abundant (quasi) molecular ion was the main advantage observed in relation to EI. Thus, a notable improvement in sensitivity and specificity was observed when using it as precursor ion in tandem MS. The improved detectability (LODs < 10 fg) achieved when using APCI compared to EI has been demonstrated, which is especially relevant for highly brominated congeners. Analysis of samples from an intercomparison exercise and samples from the marine field showed the potential of this approach for the reliable identification and quantification at very low concentration levels.


Assuntos
Bromobenzenos/análise , Monitoramento Ambiental/métodos , Retardadores de Chama/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Éteres Difenil Halogenados/análise , Animais , Monitoramento Ambiental/instrumentação , Desenho de Equipamento , Peixes/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos
8.
J Chromatogr A ; 1401: 33-41, 2015 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-25997844

RESUMO

A multi-residue analytical method was developed for the determination of a range of flame retardants (FRs), including polybrominated diphenyl ethers (PBDEs), emerging halogenated FRs (EFRs) and organophosphate FRs (PFRs), in food matrices. An ultrasonication and vacuum assisted extraction (UVAE), followed by a multi-stage clean-up procedure, enabled the removal of up to 1g of lipid from 2.5 g of freeze-dried food samples and significantly reduce matrix effects. UVAE achieves a waste factor (WF) of about 10%, while the WFs of classical QuEChERS methods range usually between 50 and 90%. The low WF of UVAE leads to a dramatic improvement in the sensitivity along with saving up to 90% of spiking (internal) standards. Moreover, a two-stage clean-up on Florisil and aminopropyl silica was introduced after UVAE, for an efficient removal of pigments and residual lipids, which led to cleaner extracts than normally achieved by dispersive solid phase extraction (d-SPE). In this way, the extracts could be concentrated to low volumes, e.g. <100 µL and the equivalent matrix concentrations were up to 100g ww/mL. The final analysis of PFRs was performed on GC-EI-MS, while PBDEs and EFRs were measured by GC-ECNI-MS. Validation tests were performed with three food matrices (lean beef, whole chicken egg and salmon filet), obtaining acceptable recoveries (66-135%) with good repeatability (RSD 1-24%, mean 7%). Method LOQs ranged between 0.008 and 0.04 ng/g dw for PBDEs, between 0.08 and 0.20 ng/g dw for EFRs, and between 1.4 and 3.6 ng/g dw for PFRs. The method was further applied to eight types of food samples (including meat, eggs, fish, and seafood) with lipid contents ranging from 0.1 to 22%. Various FRs were detected above MLOQ levels, demonstrating the wide-range applicability of our method. To the best of our knowledge, this is the first method reported for simultaneous analysis of brominated and organophosphate FRs in food matrices.


Assuntos
Poluentes Ambientais/análise , Retardadores de Chama/análise , Tecnologia de Alimentos/métodos , Cromatografia Gasosa-Espectrometria de Massas , Extração em Fase Sólida , Animais , Ovos/análise , Peixes , Éteres Difenil Halogenados/análise , Halogenação , Organofosfatos/análise , Alimentos Marinhos/análise , Vácuo
9.
Anal Chim Acta ; 853: 625-636, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25467512

RESUMO

Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg µL(-1) and from 0.06 to 0.49 pg µL(-1) in GC-MS and UHPLC-MS(2), respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC-MS) and accuracy. But some advantages of the UHPLC-MS(2) method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC-MS(2) method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 µg L(-1)), followed by MiBP (23.3 µg L(-1)), 5cx-MEPP (22.5 µg L(-1)) and MBP (19.3µgL(-1)). MMP (6.99 µg L(-1)), 5oxo-MEHP (6.15 µg L(-1)), 5OH-MEHP (5.30 µg L(-1)) and MEHP (4.40 µg L(-1)) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 µg L(-1)). These data are within the same order of magnitude as those found in other similar populations.


Assuntos
Cromatografia Líquida de Alta Pressão , Cromatografia Gasosa-Espectrometria de Massas , Ácidos Ftálicos/urina , Espectrometria de Massas por Ionização por Electrospray , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ácidos Ftálicos/metabolismo
10.
J Sep Sci ; 29(1): 123-30, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16485717

RESUMO

The different parameters affecting the ionisation and fragmentation of selected polychlorinated biphenyls (PCBs) in an IT detector working in the MS/MS mode, ITD(MS/MS), have been optimised for maximum selectivity and sensibility. The low LODs (in the range 0.03-0.3 microg/L), the satisfactory repeatability (RSDs in general below 11%) and reproducibility (RSDs below 17%) obtained when analysing standard solutions ensured proper determination of the PCBs studied at the concentrations typically found in food samples. Foodstuffs naturally contaminated with varying levels of PCBs have been analysed using the optimised GC-ITD(MS/MS) method. The results obtained compared favourably with those found using more conventional detectors, such as (micro-)electron capture detection (for ortho-PCBs) and high-resolution MS (for non-ortho-PCBs), as well as with the consensus PCB levels established for these particular samples via an international interlaboratory exercise. The relative merits of these three detectors have been discussed.

11.
Rapid Commun Mass Spectrom ; 20(2): 69-74, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16331726

RESUMO

A method based on gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITD-MS/MS), using isotope dilution, was developed for the determination of ten native polybrominated diphenyl ethers (PBDEs) and four (13)C(12)-labeled congeners in biological (fat tissue and human serum) and food samples. The highest-mass fragment ions were used as precursor ions for those congeners with molecular ions with m/z values higher than the maximum of the instrument. In these cases (hepta-BDEs and (13)C(12)-hexa-BDEs) no fragmentation was achieved under the experimental conditions employed. Repeatability (lower than 9%) and reproducibility (lower than 13%), expressed as relative standard deviation (RSD, n = 3 and 4, respectively), were satisfactory. Similarly, the coefficient of variation (n = 4) of the isotopic ratio between the two most abundant product ions was lower than 10 and 6% for native and labeled congeners, respectively. To evaluate the feasibility of the method, the optimized isotope dilution GC/ITD-MS/MS method was used for the quantitation of selected PBDE congeners in different samples including adipose tissue, human serum and foodstuff samples, from three inter-laboratory comparative exercises, covering a wide range of concentrations. A solid-phase extraction procedure, previously developed for PCB determination in small-size bird serum samples, was successfully applied to quantification of PBDEs in 1 mL samples of human serum.


Assuntos
Tecido Adiposo/química , Análise Química do Sangue/métodos , Cromatografia Gasosa/métodos , Análise de Alimentos/métodos , Bifenil Polibromatos/análise , Técnica de Diluição de Radioisótopos , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Poluentes Ambientais/análise , Éteres/análise , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA