Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31427247

RESUMO

AIM: To analyze the relationship between measurements of global heterogeneity, obtained from 18F-FDG PET/CT, with biological variables, and their predictive and prognostic role in patients with locally advanced breast cancer (LABC). MATERIAL AND METHODS: 68 patients from a multicenter and prospective study, with LABC and a baseline 18F-FDG PET/CT were included. Immunohistochemical profile [estrogen receptors (ER) and progesterone receptors (PR), expression of the HER-2 oncogene, Ki-67 proliferation index and tumor histological grade], response to neoadjuvant chemotherapy (NC), overall survival (OS) and disease-free survival (DFS) were obtained as clinical variables. Three-dimensional segmentation of the lesions, providing SUV, volumetric [metabolic tumor volume (MTV) and total lesion glycolysis (TLG)] and global heterogeneity variables [coefficient of variation (COV) and SUVmean/SUVmax ratio], as well as sphericity was performed. The correlation between the results obtained with the immunohistochemical profile, the response to NC and survival was also analyzed. RESULTS: Of the patients included, 62 received NC. Only 18 responded. 13 patients relapsed and 11 died during follow-up. ER negative tumors had a lower COV (p=0.018) as well as those with high Ki-67 (p=0.001) and high risk phenotype (p=0.033) compared to the rest. No PET variable showed association with the response to NC nor OS. There was an inverse relationship between sphericity with DFS (p=0.041), so, for every tenth that sphericity increases, the risk of recurrence decreases by 37%. CONCLUSIONS: Breast tumors in our LABC dataset behaved as homogeneous and spherical lesions. Larger volumes were associated with a lower sphericity. Global heterogeneity variables and sphericity do not seem to have a predictive role in response to NC nor in OS. More spherical tumors with less variation in gray intensity between voxels showed a lower risk of recurrence.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Neoplasias da Mama/patologia , Feminino , Humanos , Imuno-Histoquímica , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Prognóstico
3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29107751

RESUMO

AIM: To assess the diagnostic accuracy of 18F-FDG PET/contrast enhanced computed tomography (ceCT) in the detection of asymptomatic recurrences in patients with lymphoma. MATERIAL AND METHODS: Patients with lymphoma and clinical complete remission underwent 18F-FDG PET/ceCT for standard follow-up.18F-FDG PET and ceCT were evaluated blindly by two independent observers, and classified as positive or negative for recurrence. Additionally a combined evaluation of both techniques was performed. The final diagnosis was established by histopathological analysis or a clinical follow-up longer than 6 months. Statistical diagnostic parameters and concordance levels between both diagnostic techniques were calculated. RESULTS: A total of 114 explorations on 90 patients were analyzed. Only 4 patients were diagnosed as asymptomatic recurrence during the follow-up. 18F-FDG PET/ceCT, 18F-FDG PET and ceCT showed an association with the final diagnosis (p=0.002 and χ2=11.96; p<0.001 and χ2=15.60; p=0.001 and χ2=11.96, respectively). The concordance between 18F-FDG PET and ceCT was moderate/high and significant (kappa=0.672; p<0.001). A sensitivity and specificity of 50% and 88% was obtained for the 18F-FDG PET/ceCT civ, 50% and 93% for the 18F-FDG PET, and 50% and 91% for the ceCT. CONCLUSION: The combined use of 18F-FDG PET/ceCT did not offer any advantage compared to any isolated diagnostic technique in the detection of asymptomatic lymphoma recurrence.


Assuntos
Linfoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Doenças Assintomáticas , Feminino , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Seguimentos , Humanos , Masculino , Compostos Radiofarmacêuticos , Recidiva , Indução de Remissão , Estudos Retrospectivos , Sensibilidade e Especificidade , Método Simples-Cego
6.
Ultrasound Obstet Gynecol ; 21(6): 583-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12808676

RESUMO

OBJECTIVE: To evaluate the role of transvaginal power Doppler sonography to discriminate between benign and malignant endometrial conditions in women presenting with postmenopausal bleeding and thickened endometrium at baseline sonography. METHODS: Ninety-one postmenopausal women (median age, 58 years; range, 47-83 years) presenting with uterine bleeding and a thickened endometrium (> or = 5-mm double-layer endometrial thickness) on transvaginal sonography were included in this prospective study. Endometrial blood flow distribution was assessed in all patients by power Doppler immediately after B-mode transvaginal sonography. Three different vascular patterns were defined: Pattern A: multiple-vessel pattern, Pattern B: single-vessel pattern and Pattern C: scattered-vessel pattern. Histological diagnoses were obtained in all cases. No patient taking tamoxifen citrate or receiving hormone replacement therapy was included. RESULTS: Histological diagnoses were as follows: endometrial cancer: 33 (36%), endometrial polyp: 37 (41%), endometrial hyperplasia: 14 (15%), endometrial cystic atrophy: 7 (8%). Blood flow was found in 97%, 92%, 79% and 85% of cases of carcinoma, polyp, hyperplasia and endometrial cystic atrophy, respectively. A total of 81.3% of vascularized endometrial cancers showed Pattern A, 97.1% of vascularized polyps exhibited Pattern B and 72.7% of vascularized hyperplasias showed Pattern C. Sensitivity and specificity for endometrial cancer were 78.8% and 100%. For endometrial polyp these respective values were 89.2% and 87% and for hyperplasia they were 57.1% and 88.3%. CONCLUSIONS: Transvaginal power Doppler blood flow mapping is useful to differentiate benign from malignant endometrial pathology in women presenting with postmenopausal bleeding and thickened endometrium at baseline sonography.


Assuntos
Endométrio/irrigação sanguínea , Hemorragia Uterina/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Cistos/diagnóstico por imagem , Cistos/fisiopatologia , Hiperplasia Endometrial/diagnóstico por imagem , Hiperplasia Endometrial/fisiopatologia , Neoplasias do Endométrio/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade , Pólipos/diagnóstico por imagem , Pólipos/fisiopatologia , Pós-Menopausa , Ultrassonografia Doppler/métodos , Hemorragia Uterina/diagnóstico por imagem
7.
An Sist Sanit Navar ; 25(1): 21-9, 2002.
Artigo em Espanhol | MEDLINE | ID: mdl-12861300

RESUMO

BACKGROUND: Positron emission tomography with fluor-18-deoxyglucose (PET-FDG) is an efficient technique for the detection of tumoural tissue. The aim of the paper is to evaluate the PET-FDG in the diagnosis of residual disease or relapse in patients with cancer of the ovary. METHODS: A total of 24 patients, diagnosed and treated for cancer of the ovary with surgery and subsequent chemotherapy, were included. With 12 patients the study was carried out prior to second-look surgery, and with the other 12 after objectivising an increase of the tumoural marker in the follow up. Abdominal-pelvic CAT, determination of the seric levels of CA-125 and PET-FDG of thorax, abdomen and pelvis were carried out on all patients. The PET-FDG was evaluated in a qualitative way through the visual study of the images, and quantitatively through the SUV or standard uptake value. The definitive diagnosis was confirmed through an anatomopathological study in 13 cases and through clinical follow up in the rest with an average of 11.2+/-5.4 months (range 6-24). RESULTS: A CA-125 value higher than 35 UI/ml was considered positive, obtaining a sensitivity of 77% and a specificity of 100%. The sensitivity of the CAT was 23% and the specificity 91%. With the FDG-PET sensitivity was 92% and the specificity 90%. A SUV value >or= 3 was considered pathological, obtaining the same results as with the visual evaluation. The FDG-PET was positive in 5 patients with non-conclusive CAT, 4 with negative CAT and 2 with negative CA-125. CONCLUSION: These preliminary results suggest that the FDG-PET could be useful in the detection of disease in the follow up of patients treated for cancer of the ovary. The FDG-PET could be efficient in the differentiation between residual disease or recurrence, as opposed to sequels to the treatment, when the CAT is not conclusive due to anatomical distortion, since it permits the detection of tumoural lesions undetected by the radiological image techniques but metabolically active. The FDG-PET could be more sensitive than an increased marker value, and facing an increase of the latter it permits a non-invasive localisation of the disease.

8.
J Ultrasound Med ; 20(8): 915-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11503928

RESUMO

OBJECTIVE: To describe the sonographic characteristics of ovarian cystadenofibromas. METHODS: We conducted a retrospective study of 23 ovarian tumors histopathologically confirmed as ovarian cystadenofibromas that were preoperatively evaluated by transvaginal color Doppler sonography. RESULTS: In all cases the mass was predominantly cystic. Septations appeared in 30.4% of the tumors. Papillary projections or solid nodules appeared in 56.5% of the cases. The most frequent appearance was a unilocular complex cystic mass. In 47.8% of the tumors, vascularization was detected, having a typical pattern of peripheral vascularization with scattered vessels of high blood flow impedance. CONCLUSIONS: We have described the sonographic spectrum of findings of ovarian cystadenofibromas. The most frequent appearance was a unilocular cystic mass with gross papillary projections or solid nodules. In almost half of the tumors, vascularization could be detected.


Assuntos
Adenofibroma/diagnóstico por imagem , Cistadenoma Seroso/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico por imagem , Adenofibroma/patologia , Adulto , Idoso , Cistadenoma Seroso/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/patologia , Estudos Retrospectivos , Ultrassonografia
9.
Int J Gynaecol Obstet ; 66(3): 255-61, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10580673

RESUMO

OBJECTIVE: To compare diagnostic performance of color Doppler ultrasound and CA-125 in suspicious adnexal masses on B-mode sonography. MATERIALS AND METHODS: Data on 94 patients (mean age: 47.4 years, range: 17-79 years. Fifty-two (55.3%) premenopausal and 42 (44.7%) postmenopausal women) managed in our institution because of a suspicious adnexal mass were reviewed. All patients were evaluated by transvaginal color Doppler ultrasonography (CD) and serum CA-125 level determination prior to surgery. Definitive histopathological diagnosis was obtained in each case. Sonographic morphology evaluation was suspicious in all cases. CD was considered as suspicious when flow was detected and the lowest RI found was < or = 0.45. CA-125 cut-off was > or = 35 UI/ml. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each method and compared. ROC analysis was performed for RI and CA-125. Areas under curve (AUC) were calculated and compared. RESULTS: Fifty-six (59.6%) tumors were found to be malignant and 38 (40.4%) benign. Sensitivity, specificity, PPV and NPV for CD were 87.5% (95% CIs: 75.3-94.4), 84.2% (95% CIs: 68.7-94), 89.1% (95% CIs: 77.7-95.9) and 82.1% (95% CIs: 66.5-92.5), respectively. Sensitivity, specificity, PPV and NPV for CA-125 were 83.9% (95% CIs: 71.7-92.4), 68.4% (95% CIs: 51.3-82.5), 79.7% (95% CIs: 66.2-89) and 74.3% (95% CIs: 56.7-87.5), respectively. Sensitivity, PPV and NPV were not statistically different. CD had higher specificity (P = 0.01). AUC curve for Doppler (0.75) was significantly higher than for CA-125 (0.61) (P = 0.0002). CONCLUSIONS: Our results indicate that color Doppler ultrasound has a better diagnostic performance as compared with CA-125, being significantly more specific.


Assuntos
Doenças dos Anexos/diagnóstico , Biomarcadores Tumorais/sangue , Antígeno Ca-125/sangue , Neoplasias Ovarianas/diagnóstico , Ultrassonografia Doppler em Cores , Doenças dos Anexos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico por imagem , Pós-Menopausa , Valor Preditivo dos Testes , Pré-Menopausa , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA