Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195248

RESUMO

BACKGROUND: Patients treated with mechanical thrombectomy (MT) for acute ischemic strokes from large vessel occlusion (LVO) have better outcomes with effective reperfusion. However, it is unknown which technique leads to better technical and clinical success. We aimed to determine which technique yields the most effective first pass reperfusion during MT. METHODS: In a prospective, multicenter global registry we enrolled patients treated with operator preferred MT technique at 71 hospitals from January 2019 to January 2022. Three techniques were assessed: SR Classic with stent retriever (SR) and balloon guide catheter (BGC); SR Combination which employed SR with contact aspiration with or without BGC; and direct aspiration (DA) with or without BGC. The primary outcome was achieving an expanded Thrombolysis In Cerebral Infarction (eTICI) score of 2c or 3 on the first pass, with the primary technique as adjudicated by core lab. The primary clinical outcome measure was a 90-day modified Rankin Scale (mRS) score of 0-2. RESULTS: A total of 1492 patients were enrolled. Patients treated with SR Classic or SR Combination were more likely to achieve first pass eTICI 2c or 3 reperfusion (P=0.01). There was no significant difference in mRS 0-2 (P=0.46) or safety endpoints. CONCLUSIONS: The use of SR Classic or SR Combination was more likely to achieve first pass eTICI 2c or 3 reperfusion. There were no significant differences in clinical outcomes and safety endpoints.

2.
J Neurointerv Surg ; 16(4): 405-411, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-37793795

RESUMO

BACKGROUND: Robotic-assisted neurointervention was recently introduced, with implications that it could be used to treat neurovascular diseases. OBJECTIVE: To evaluate the effectiveness and safety of the robotic-assisted platform CorPath GRX for treating cerebral aneurysms. METHODS: This prospective, international, multicenter study enrolled patients with brain aneurysms that required endovascular coiling and/or stent-assisted coiling. The primary effectiveness endpoint was defined as successful completion of the robotic-assisted endovascular procedure without any unplanned conversion to manual treatment with guidewire or microcatheter navigation, embolization coil(s) or intracranial stent(s) deployment, or an inability to navigate vessel anatomy. The primary safety endpoint included intraprocedural and periprocedural events. RESULTS: The study enrolled 117 patients (74.4% female) with mean age of 56.6 years from 10 international sites,. Headache was the most common presenting symptom in 40/117 (34.2%) subjects. Internal carotid artery was the most common location (34/122, 27.9%), and the mean aneurysm height and neck width were 5.7±2.6 mm and 3.5±1.4 mm, respectively. The overall procedure time was 117.3±47.3 min with 59.4±32.6 min robotic procedure time. Primary effectiveness was achieved in 110/117 (94%) subjects with seven subjects requiring conversion to manual for procedure completion. Only four primary safety events were recorded with two intraprocedural aneurysm ruptures and two strokes. A Raymond-Roy Classification Scale score of 1 was achieved in 71/110 (64.5%) subjects, and all subjects were discharged with a modified Rankin Scale score of ≤2. CONCLUSIONS: This first-of-its-kind robotic-assisted neurovascular trial demonstrates the effectiveness and safety of the CorPath GRX System for endovascular embolization of cerebral aneurysm procedures. TRIAL REGISTRATION NUMBER: NCT04236856.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Procedimentos Cirúrgicos Robóticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Stents , Resultado do Tratamento
3.
J Neurointerv Surg ; 16(3): 230-236, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-37142393

RESUMO

BACKGROUND: Numerous questions regarding procedural details of distal stroke thrombectomy remain unanswered. This study assesses the effect of anesthetic strategies on procedural, clinical and safety outcomes following thrombectomy for distal medium vessel occlusions (DMVOs). METHODS: Patients with isolated DMVO stroke from the TOPMOST registry were analyzed with regard to anesthetic strategies (ie, conscious sedation (CS), local (LA) or general anesthesia (GA)). Occlusions were in the P2/P3 or A2-A4 segments of the posterior and anterior cerebral arteries (PCA and ACA), respectively. The primary endpoint was the rate of complete reperfusion (modified Thrombolysis in Cerebral Infarction score 3) and the secondary endpoint was the rate of modified Rankin Scale score 0-1. Safety endpoints were the occurrence of symptomatic intracranial hemorrhage and mortality. RESULTS: Overall, 233 patients were included. The median age was 75 years (range 64-82), 50.6% (n=118) were female, and the baseline National Institutes of Health Stroke Scale score was 8 (IQR 4-12). DMVOs were in the PCA in 59.7% (n=139) and in the ACA in 40.3% (n=94). Thrombectomy was performed under LA±CS (51.1%, n=119) and GA (48.9%, n=114). Complete reperfusion was reached in 73.9% (n=88) and 71.9% (n=82) in the LA±CS and GA groups, respectively (P=0.729). In subgroup analysis, thrombectomy for ACA DMVO favored GA over LA±CS (aOR 3.07, 95% CI 1.24 to 7.57, P=0.015). Rates of secondary and safety outcomes were similar in the LA±CS and GA groups. CONCLUSION: LA±CS compared with GA resulted in similar reperfusion rates after thrombectomy for DMVO stroke of the ACA and PCA. GA may facilitate achieving complete reperfusion in DMVO stroke of the ACA. Safety and functional long-term outcomes were comparable in both groups.


Assuntos
Anestésicos , Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Artéria Cerebral Posterior , Resultado do Tratamento , Acidente Vascular Cerebral/cirurgia , Trombectomia/efeitos adversos , Trombectomia/métodos , Estudos Retrospectivos , Procedimentos Endovasculares/métodos
4.
J Neurointerv Surg ; 13(12): 1145-1151, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33832971

RESUMO

BACKGROUND: The aim of this study was to assess the technical success and procedural safety of the new Silk Vista device (SV) by evaluating the intraprocedural and periprocedural complication rate after its use in several institutions worldwide. METHODS: The study involved a retrospective review of multicenter data regarding a consecutive series of patients with intracranial aneurysms, treated with the SV between September 2020 and January 2021. Clinical, intra/periprocedural and angiographic data, including approach, materials used, aneurysm size and location, device/s, technical details and initial angiographic aneurysm occlusion, were analyzed. RESULTS: 60 aneurysms were treated with SV in 57 procedures. 66 devices were used, 3 removed and 63 implanted. The devices opened instantaneously in 60 out of 66 (91%) cases and complete wall apposition was achieved in 58 out of 63 (92%) devices implanted. In 4 out of 66 (6%) devices a partial opening of the distal end occurred, and in 5 (8%) devices incomplete apposition was reported. There were 3 (5%) intraprocedural thromboembolic events managed successfully with no permanent neurological morbidity, and 4 (7%) postprocedural events. There was no mortality in this study. The initial occlusion rates in the 60 aneurysms were as follows: O'Kelly-Marotta (OKM) A in 34 (57%) cases, OKM B in 15 (25%) cases, OKM C in 6 (10%) cases, and OKM D in 5 (8%) cases. CONCLUSIONS: Our study demonstrated that the use of the new flow diverter Silk Vista for the treatment of intracranial aneurysms is feasible and technically safe.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Seda , Stents , Resultado do Tratamento
5.
J Neurointerv Surg ; 13(4): 357-362, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33593801

RESUMO

BACKGROUND: Radial artery access for transarterial procedures has gained recent traction in neurointerventional due to decreased patient morbidity, technical feasibility, and improved patient satisfaction. Upper extremity transvenous access (UETV) has recently emerged as an alternative strategy for the neurointerventionalist, but data are limited. Our objective was to quantify the use of UETV access in neurointerventions and to measure failure and complication rates. METHODS: An international multicenter retrospective review of medical records for patients undergoing UETV neurointerventions or diagnostic procedures was performed. We also present our institutional protocol for obtaining UETV and review the existing literature. RESULTS: One hundred and thirteen patients underwent a total of 147 attempted UETV procedures at 13 centers. The most common site of entry was the right basilic vein. There were 21 repeat puncture events into the same vein following the primary diagnostic procedure for secondary interventional procedures without difficulty. There were two minor complications (1.4%) and five failures (ie, conversion to femoral vein access) (3.4%). CONCLUSIONS: UETV is safe and technically feasible for diagnostic and neurointerventional procedures. Further studies are needed to determine the benefit over alternative venous access sites and the effect on patient satisfaction.


Assuntos
Procedimentos Endovasculares/métodos , Internacionalidade , Artéria Radial/diagnóstico por imagem , Artéria Radial/cirurgia , Extremidade Superior/diagnóstico por imagem , Extremidade Superior/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Extremidade Superior/irrigação sanguínea
6.
J Neurointerv Surg ; 13(1): 39-41, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32759328

RESUMO

A simultaneous arterial and venous approach has been widely described for the endovascular treatment of dural arteriovenous fistula (DAVFs) and recently for arteriovenous malformation (AVMs). Conventional venous approaches are performed by direct internal jugular puncture or by femoral access. Although complication rates are low, there are potential life-threatening complications that should be avoided. The advantages of radial artery access have been widely proven, nevertheless the use of upper limb veins in neurointervention are rarely reported. We present five cases of the simultaneous arteriovenous approach through the radial artery and superficial veins of the forearm for the treatment of intracranial neurovascular diseases.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Antebraço/irrigação sanguínea , Antebraço/diagnóstico por imagem , Artéria Radial/diagnóstico por imagem , Veias/diagnóstico por imagem , Adulto , Idoso , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/cirurgia , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/cirurgia , Veias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA