Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 231: 115411, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37094410

RESUMO

Nucleic acid-based analytical bioplatforms have gained importance as diagnostic tests for genomics and as early detection tools for diseases such as cancer. In this context, we report the development of an amperometric bioplatform for the determination of a specific human papillomavirus type 16 (HPV16) sequence. The bioplatform utilizes an immune-nucleic acid hybrid-sandwich assay. A biotinylated RNA capture probe (RNAbCp), complementary to the selected HPV16 target DNA sequence, was immobilised on the surface of streptavidin coated magnetic microbeads (Strep-MBs). The RNA/DNA heteroduplex resulting from the hybridization of the RNAbCP and the HPV16 target sequence was recognised by a commercial antibody that specifically bound to the heteroduplex (AbDNA-RNA). A horseradish-peroxide labeled secondary antibody (antiIgG-HRP) was used for the detection of AbDNA-RNA. Relying on amperometric detection of the resulting HRP-labeled magnetic bioconjugates captured on screen-printed electrodes (SPCEs) in the presence of H2O2 and hydroquinone (HQ), the biotool achieved a low limit of detection (0.5 pM) for the synthetic HPV16 target DNA. In addition, the developed bioplatform was able to discriminate between HPV16 positive and negative human cancer cells using only 25 ng of amplified DNA in a test time of 45 min.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Papillomavirus Humano , Carcinógenos , Peróxido de Hidrogênio , DNA , RNA , Anticorpos , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Eletrodos
2.
Anal Bioanal Chem ; 415(11): 2045-2057, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36344668

RESUMO

The glycosylation status of proteins is increasingly used as biomarker to improve the reliability in the diagnosis and prognosis of diseases as relevant as cancer. This feeds the need for tools that allow its simple and reliable analysis and are compatible with applicability in the clinic. With this objective in mind, this work reports the first bioelectronic immunoplatforms described to date for the determination of glycosylated haptoglobin (Hp) and the simultaneous determination of total and glycosylated Hp. The bioelectronic immunoplatform is based on the implementation of non-competitive bioassays using two different antibodies or an antibody and a lectin on the surface of commercial magnetic microcarriers. The resulting bioconjugates are labeled with the horseradish peroxidase (HRP) enzyme, and after their magnetic capture on disposable electroplatforms, the amperometric transduction using the H2O2/hydroquinone (HQ) system allows the single or multiple detection. The developed immunoplatform achieves limits of detection (LODs) of 0.07 and 0.46 ng mL-1 for total and glycosylated Hp in buffer solution, respectively. The immunoplatform allows accurate determination using simple and relatively short protocols (approx. 75 min) of total and glycosylated Hp in the secretomes of in vitro-cultured colorectal cancer (CRC) cells with different metastatic potentials, which is not feasible, due to lack of sensitivity, by means of some commercial ELISA kits and Western blot methodology.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Haptoglobinas , Peróxido de Hidrogênio , Reprodutibilidade dos Testes , Ensaio de Imunoadsorção Enzimática , Anticorpos , Técnicas Biossensoriais/métodos
3.
Anal Bioanal Chem ; 414(1): 399-412, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33635388

RESUMO

Metastasis is responsible for about 90% of cancer-associated deaths. In the context of solid tumors, the low oxygen concentration in the tumor microenvironment (hypoxia) is one of the key factors contributing to metastasis. Tumor cells adapt to these conditions by overexpressing certain proteins such as programmed death ligand 1 (PD-L1) and hypoxia-inducible factor 1 alpha (HIF-1α). However, the determination of these tumor hypoxia markers that can be used to follow-up tumor progression and improve the efficiency of therapies has been scarcely addressed using electrochemical biosensors. In this work, we report the first electrochemical bioplatform for the determination of PD-L1 as well as the first one allowing its simultaneous determination with HIF-1α. The target proteins were captured and enzymatically labeled on magnetic microbeads and amperometric detection was undertaken on the surface of screen-printed dual carbon electrodes using the hydrogen peroxide/peroxidase/hydroquinone system. Sandwich immunoassays were implemented for both the HIF-1α and PD-L1 sensors and the analytical characteristics were evaluated providing LOD values of 86 and 279 pg mL-1 for the amperometric determination of PD-L1 and HIF-1α standards, respectively. The developed electrochemical immunoplatforms are competitive versus the only electrochemical immunosensor reported for the determination of HIF-1α and the "gold standard" ELISA methodology for the single determination of both proteins in terms of assay time, compatibility with the simultaneous determination of both proteins making their use suitable for untrained users at the point of attention. The dual amperometric immunosensor was applied to the simultaneous determination of HIF-1α and PD-L1 in cancer cell lysates. The analyses lasted only 2 h and just 0.5 µg of the sample was required.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Biomarcadores Tumorais/análise , Técnicas Biossensoriais/métodos , Humanos , Hipóxia , Imunoensaio , Hipóxia Tumoral
4.
Anal Chim Acta ; 1182: 338946, 2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34602192

RESUMO

This work reports the first electrochemical bioplatform developed for the multidetection of 5-methylcytosine (5-mC) and 5-hydroxymethylcytosine (5-hmC) in DNA, DNA N6-methyladenine (6mA) and RNA N6-methyladenosine (m6A) methylations at global level. Direct competitive immunoassays were implemented on the surface of magnetic beads (MBs) and optimized for the single amperometric determination of different targets varying in length, sequence and number of methylations on screen-printed carbon electrodes. After evaluating the sensitivity and selectivity of such determinations and the confirmation of no cross-reactivity, a multiplexed disposable platform allowing the simultaneous determination of the mentioned four methylation events in only 45 min has been prepared. The multiplexed bioplatform was successfully applied to the determination of m6A in cellular total RNA and of 5-mC, 5-hmC and 6mA in genomic DNA extracted from tissues. The developed bioplatform showed its usefulness to discriminate the aggressiveness of cancerous cells and between healthy and tumor tissues of colorectal cancer patients.


Assuntos
Ácidos Nucleicos , Adenosina , Humanos , Fenômenos Magnéticos , Metilação , RNA
5.
Biosensors (Basel) ; 11(6)2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34205541

RESUMO

A magnetic beads (MB)-involved amperometric immunosensor for the determination of ST2, a member of the IL1 receptor family, is reported in this work. The method utilizes a sandwich immunoassay and disposable screen-printed carbon electrodes (SPCEs). Magnetic immunoconjugates built on the surface of carboxylic acid-microsized magnetic particles (HOOC-MBs) were used to selectively capture ST2. A biotinylated secondary antibody further conjugated with a streptavidin peroxidase conjugate (Strep-HRP) was used to accomplish the sandwiching of the target protein. The immune platform exhibits great selectivity and a low limit of detection (39.6 pg mL-1) for ST2, allowing the determination of soluble ST2 (sST2) in plasma samples from healthy individuals and patients diagnosed with pancreatic ductal adenocarcinoma (PDAC) in only 45 min once the immunoconjugates have been prepared. The good correlation of the obtained results with those provided by an ELISA kit performed using the same immunoreagents demonstrates the potential of the developed strategy for early diagnosis and/or prognosis of the fatal PDAC disease.


Assuntos
Técnicas Biossensoriais , Imunoensaio , Neoplasias/diagnóstico , Anticorpos , Carbono , Técnicas Eletroquímicas , Eletrodos , Ensaio de Imunoadsorção Enzimática , Humanos , Peróxido de Hidrogênio , Limite de Detecção , Magnetismo
6.
Biosens Bioelectron ; 171: 112708, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33049562

RESUMO

This work describes the preparation of an immunoplatform for the sensitive and selective determination of N6-methyladenosine (m6A). The simple and fast protocol involves for the first time the use of micromagnetic immunoconjugates to establish a direct competitive assay between the m6A target and a biotinylated RNA oligomer bearing a single m6A enzymatically labelled with a commercial conjugate of streptavidin-peroxidase (Strep-HRP) as tracer. The cathodic current change measured in the presence of H2O2/hydroquinone (HQ) at screen-printed carbon electrodes (SPCEs) upon surface capturing the magnetic bioconjugates is inversely proportional to the m6A target concentration. After evaluating the effect of key variables, the analytical characteristics were established for the determination of three different targets: the N6-methyladenosine-5'-triphosphate (m6ATP) ribonucleotide, a short synthetic RNA oligomer bearing a single m6A and the positive control provided in a commercial colorimetric kit for m6A-RNA quantification. The obtained results show that this immunoplatform is competitive with other methods reported to date, achieving an improved sensitivity (limit of detection of 0.9 pM for the short synthetic oligomer) using a much simpler and faster protocol (~1 h) and disposable electrodes for the transduction. Furthermore, the applicability for discriminating the metastatic potential of cancer cells by directly analyzing a small amount of raw total RNA without enriching or fragmenting was also preliminary assessed.


Assuntos
Técnicas Biossensoriais , Neoplasias , Adenosina/análogos & derivados , Peróxido de Hidrogênio , Limite de Detecção , Fenômenos Magnéticos , Microesferas
7.
Anal Chem ; 92(7): 5604-5612, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32073832

RESUMO

This work reports the first bioplatform able to determine electrochemically 5-hydroxymethylcytosine (5-hmC) methylation events at localized sites and single-base sensitivity. The described bioplatform relies on a specific antibody (anti-5-hmC), further conjugated with commercial bioreagents loaded with multiple horseradish peroxidase (HRP) molecules, recognizing the epimark in a target DNA, captured through hybridization onto streptavidin-magnetic microbeads (Strep-MBs) modified with a complementary DNA capture probe. The electrochemical detection is performed by amperometry (-0.20 V vs Ag pseudoreference electrode) at disposable screen-printed carbon electrodes (SPCEs) in the presence of H2O2/hydroquinone (HQ) upon magnetic capture of the modified MBs onto the SPCE. The use of the commercial bioreagents ProtA-polyHRP80 and Histostar, very scarcely explored so far in electrochemical biosensors, provides high sensitivities for a synthetic target DNA sequence with a unique 5-hmC in the promoter region of MGMT tumor suppressor gene. Amplification factors of 43.6 and 55.2 were achieved using ProtA-polyHRP80 or Histostar, respectively, compared to the conventional secondary antibody labeling. This amplification was crucial to detect methylation events at single-nucleotide resolution achieving limits of detection (LODs) of 23.0 and 13.2 pM, respectively, without any target DNA amplification. The ProtA-polyHRP80-based bioplatform, selected as a compromise between sensitivity and cost per determination, exhibited full discrimination toward the target 5-hmC against the closely related 5-mC. In addition, the bioplatform detected 5-hmC at the regional level (MGMT promoter region) in just 10 ng of genomic DNA (gDNA, ∼2700 genomes) extracted from cancer cells and tissues from colorectal cancer (CRC) patients within 60 min.


Assuntos
Metilação de DNA , Eletroquímica/métodos , 5-Metilcitosina/análogos & derivados , 5-Metilcitosina/metabolismo , Linhagem Celular Tumoral , Humanos , Limite de Detecção
8.
Anal Bioanal Chem ; 412(24): 6177-6188, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31989193

RESUMO

Proteases are involved in cancer' taking part in immune (dis)regulation, malignant progression and tumour growth. Recently, it has been found that expression levels of one of the members of the serine protease family, trypsin, is upregulated in human cancer cells of several organs, being considered as a specific cancer biomarker. Considering the great attention that electrochemical peptide sensors have nowadays, in this work, we propose a novel electroanalytical strategy for the determination of this important biomolecule. It implies the immobilization of a short synthetic peptide sequence, dually labelled with fluorescein isothiocyanate (FITC) and biotin, onto neutravidin-modified magnetic beads (MBs), followed by the peptide digestion with trypsin. Upon peptide disruption, the modified MBs were incubated with a specific fluorescein Fab fragment antibody labelled with horseradish peroxidase (HRP-antiFITC) and magnetically captured on the surface of a screen-printed carbon electrode (SPCE), where amperometric detection was performed using the hydroquinone (HQ)/HRP/H2O2 system. The biosensor exhibited a good reproducibility of the measurements (RSD 3.4%, n = 10), and specificity against other proteins and proteases commonly found in biological samples. This work reports the first quantitative data so far on trypsin expression in human cell lysates. The developed bioplatform was used for the direct determination of this protease in lysates from pancreatic cancer, cervix carcinoma and kidney cells in only 3 h and 30 min using low amounts (~ 0.1 µg) of raw extracts. Graphical abstract.


Assuntos
Técnicas Eletroquímicas/métodos , Metástase Neoplásica , Neoplasias Pancreáticas/enzimologia , Peptídeo Hidrolases/metabolismo , Peptídeos/química , Técnicas Biossensoriais , Calibragem , Humanos , Oxirredução , Neoplasias Pancreáticas/patologia , Reprodutibilidade dos Testes
9.
Anal Bioanal Chem ; 412(21): 5031-5041, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31745609

RESUMO

This paper reports a simple electrochemical strategy for the determination of microRNAs (miRNAs) using a commercial His-Tag-Zinc finger protein (His-Tag-ZFP) that binds preferably (but non-sequence specifically) RNA hybrids over ssRNAs, ssDNAs, and dsDNAs. The strategy involves the use of magnetic beads (His-Tag-Isolation-MBs) as solid support to capture the conjugate formed in homogenous solution between His-Tag-ZFP and the dsRNA homohybrid formed between the target miRNA (miR-21 selected as a model) and a biotinylated synthetic complementary RNA detector probe (b-RNA-Dp) further conjugated with a streptavidin-horseradish peroxidase (Strep-HRP) conjugate. The electrochemical detection is carried out by amperometry at disposable screen-printed carbon electrodes (SPCEs) (- 0.20 V vs Ag pseudo-reference electrode) upon magnetic capture of the resultant magnetic bioconjugates and H2O2 addition in the presence of hydroquinone (HQ). The as-prepared biosensor exhibits a dynamic concentration range from 3.0 to 100 nM and a detection limit (LOD) of 0.91 nM for miR-21 in just ~ 2 h. An acceptable discrimination was achieved between the target miRNA and other non-target nucleic acids (ssDNA, dsDNA, ssRNA, DNA-RNA, miR-122, miR-205, and single central- or terminal-base mismatched sequences). The biosensor was applied to the analysis of miR-21 from total RNA (RNAt) extracted from epithelial non-tumorigenic and adenocarcinoma breast cells without target amplification, pre-concentration, or reverse transcription steps. The versatility of the methodology due to the ZFP's non-sequence-specific binding behavior makes it easily extendable to determine any target RNA only by modifying the biotinylated detector probe.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , MicroRNAs/análise , Dedos de Zinco , Linhagem Celular , Linhagem Celular Tumoral , Humanos , Limite de Detecção
10.
Sensors (Basel) ; 19(17)2019 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-31480367

RESUMO

Nowadays, analyzing circulating tumor DNA (ctDNA), a very small part of circulating free DNA (cfDNA) carried by blood, is considered to be an interesting alternative to conventional single-site tumor tissue biopsies, both to assess tumor burden and provide a more comprehensive snapshot of the time-related and spatial heterogeneity of cancer genetic/epigenetic scenery. The determination of ctDNA and/or mapping its characteristic features, including tumor-specific mutations, chromosomal aberrations, microsatellite alterations, and epigenetic changes, are minimally invasive, powerful and credible biomarkers for early diagnosis, follow-up, prediction of therapy response/resistance, relapse monitoring, and tracking the rise of new mutant subclones, leading to improved cancer outcomes This review provides an outline of advances published in the last five years in electrochemical biosensing of ctDNA and surrogate markers. It emphasizes those strategies that have been successfully applied to real clinical samples. It highlights the unique opportunities they offer to shift the focus of cancer patient management methods from actual decision making, based on clinic-pathological features, to biomarker-driven treatment strategies, based on genotypes and customized targeted therapies. Also highlighted are the unmet hurdles and future key points to guide these devices in the development of liquid biopsy cornerstone tools in routine clinical practice for the diagnosis, prognosis, and therapy response monitoring in cancer patients.


Assuntos
Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/métodos , DNA Tumoral Circulante/sangue , Técnicas Eletroquímicas/métodos , Neoplasias/genética , Técnicas Biossensoriais/instrumentação , DNA Tumoral Circulante/análise , DNA Viral/sangue , Técnicas Eletroquímicas/instrumentação , Humanos , Biópsia Líquida , Mutação , Neoplasias/sangue
11.
Anal Bioanal Chem ; 405(11): 3773-81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23090651

RESUMO

Cysteamine core polyamidoamine G-4 dendron branched with ß-cyclodextrins was chemisorbed on the surface of Au electrodes and further coated with Pt nanoparticles. Adamantane-modified glucose oxidase was subsequently immobilized on the nanostructured electrode surface by supramolecular association. This enzyme electrode was used to construct a reagentless amperometric biosensor for glucose, making use of the electrochemical oxidation of H2O2 generated in the enzyme reaction. The amperometric response of the biosensor was rapid (6 s) and a linear function of glucose concentration between 5 and 705 µmol L(-1). The biosensor had a low detection limit of 2.0 µmol L(-1), sensitivity of 197 mA mol(-1) L cm(-2), and retained 94% of its initial response after storage for nine days at 4 °C.


Assuntos
Técnicas Biossensoriais/instrumentação , Cisteamina/química , Dendrímeros/química , Enzimas Imobilizadas/química , Glucose Oxidase/química , Glucose/análise , beta-Ciclodextrinas/química , Eletrodos , Ouro/química , Limite de Detecção , Modelos Moleculares , Nanopartículas/química , Platina/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA