RESUMO
BACKGROUND: Little data exist on the risk and outcomes of out-of-hospital cardiac arrest (OHCA) in people with HIV (PWH). We aimed to describe OHCA in PWH as compared with the general population in terms of incidence, characteristics, and survival. METHODS: This nationwide study assessed all individuals aged 18-85 years between 2001 and 2019 in Denmark. The cumulative incidence of OHCA was computed using cause-specific Cox models accounting for competing risk of death. RESULTS: Among 6 565 309 individuals, 6 925 (median age: 36; interquartile range [IQR]: 28-44 y; 74% males) were infected at some point with HIV. The incidence of OHCA was 149 (95% CI: 123-180)/100 000 person-years in PWH versus 64 (95% CI: 64-65)/100 000 person-years in people without HIV (P < .001). Age at the time of cardiac arrest was 52 (IQR: 44-61) years in PWH versus 69 (IQR: 59-77) years in individuals without HIV (P < .001). In a multivariable model adjusted for age, sex, hypertension, diabetes, heart failure, ischemic heart disease, atrial fibrillation, chronic obstructive pulmonary disease, cancer, and renal failure, PWH had a 2-fold higher risk of OHCA (hazard ratio: 2.84; 95% CI: 2.36-3.43; P < .001). Thirty-day mortality (89% vs 88%; P = .80) was comparable to individuals without HIV. CONCLUSIONS: HIV is an independent risk factor for OHCA, and those who experience OHCA with HIV are much younger than those without HIV. Almost 90% of PWH died 1 month after OHCA. Further research should strive to find out how to reduce OHCA occurrence in this population.
Assuntos
Infecções por HIV , Parada Cardíaca Extra-Hospitalar , Masculino , Humanos , Adulto , Feminino , Parada Cardíaca Extra-Hospitalar/epidemiologia , Estudos de Coortes , HIV , Fatores de Risco , Infecções por HIV/complicações , Infecções por HIV/epidemiologiaRESUMO
AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.
Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Eletrofisiologia Cardíaca , Fluoroscopia/métodos , Ablação por Cateter/métodosRESUMO
There is an increasing proportion of the general population surviving to old age with significant chronic disease, multi-morbidity, and disability. The prevalence of pre-frail state and frailty syndrome increases exponentially with advancing age and is associated with greater morbidity, disability, hospitalization, institutionalization, mortality, and health care resource use. Frailty represents a global problem, making early identification, evaluation, and treatment to prevent the cascade of events leading from functional decline to disability and death, one of the challenges of geriatric and general medicine. Cardiac arrhythmias are common in advancing age, chronic illness, and frailty and include a broad spectrum of rhythm and conduction abnormalities. However, no systematic studies or recommendations on the management of arrhythmias are available specifically for the elderly and frail population, and the uptake of many effective antiarrhythmic therapies in these patients remains the slowest. This European Heart Rhythm Association (EHRA) consensus document focuses on the biology of frailty, common comorbidities, and methods of assessing frailty, in respect to a specific issue of arrhythmias and conduction disease, provide evidence base advice on the management of arrhythmias in patients with frailty syndrome, and identifies knowledge gaps and directions for future research.
Assuntos
Fragilidade , Humanos , Idoso , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Fragilidade/terapia , Idoso Fragilizado , Consenso , América Latina , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Doença do Sistema de Condução CardíacoRESUMO
AIMS: Low socioeconomic status is associated with all-cause mortality and cardiac risk factors. Furthermore, sudden cardiac death (SCD) is among the leading causes of death in the general population, and an identification of high-risk subgroups is needed. The aim of this study was to investigate the association between income and education level and incidence of SCD and to calculate the impact of modifiable mediating risk factors. METHODS AND RESULTS: Participants in the Copenhagen City Heart Study were followed up from 1993 to 2016. Sudden cardiac death was identified using high-quality death certificates, autopsy reports, discharge summaries, and national registry data. Hazard ratios were calculated using Cox proportional hazards regression, and adjusted cumulative incidences were predicted using cause-specific Cox models. Mediation analyses were performed using a marginal structural model approach. During 24 years of follow-up, 10 006 people participated, whereof 5514 died during the study period with 822 SCDs. Compared with long education, persons with elementary school level education had an SCD incidence rate ratio (IRR) of 2.48 [95% confidence interval (CI) 1.86-3.31], and low income was likewise associated with an SCD IRR of 2.34 (95% CI 1.85-2.96) compared with high income. In the association between education and SCD, the combined mediating effect of smoking, physical activity, and body mass index accounted for â¼20% of the risk differences. CONCLUSION: We observed an inverse association between both income and education and the risk of SCD, which was only in part explained by common cardiac risk factors, implying that further research into the competing causes of SCD is needed and stressing the importance of targeted preventive measures.
Low socioeconomic status (e.g. education and income) has previously been found associated with an increased risk of death and with different heart diseases. Sudden cardiac death (SCD) is among the leading causes of death in the general population, and predicting who is at high risk is difficult. Finding people or groups at high risk is important to improve prevention. That is why we decided to investigate whether socioeconomic status is also associated with the risk of SCD and to calculate the impact of modifiable lifestyle factors on this risk. We followed â¼10 000 people from a general population cohort for 24 years and observed 822 sudden cardiac deaths. The lowest income and education groups had more than twice the risk of SCD compared with the high groups. Differences in smoking, physical activity, and body mass index explained â¼20% of this increase.
Assuntos
Morte Súbita Cardíaca , Fumar , Humanos , Estudos Prospectivos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Fatores de Risco , Classe Social , Atenção à Saúde , IncidênciaRESUMO
BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: Chronic obstructive pulmonary disease (COPD) is present in 13% of atrial fibrillation (AF) patients. In patients diagnosed with both AF and COPD, we aimed to assess overall mortality risk and its association with temporal sequence in AF and COPD diagnosis. METHODS: This nationwide study assessed all patients aged 18-85 years diagnosed with both COPD and AF between 1999 and 2018 in Denmark. Three groups were defined according to the temporal sequence of diagnosis: COPD diagnosed at least 6 months before AF (COPD-First), AF diagnosed at least 6 months before COPD (AF-First) and COPD, and AF diagnosed within a 6-months' time frame (AFâ¼COPD). RESULTS: We included 62 806 patients (75.0 years; 56.5% males). After 5 years of follow-up, 31 494 (50.1%) died. Mortality was highest in the COPD-First group (COPD-First: 52.8%; AF-First: 46.0%; AFâ¼COPD 50.6%). In a multivariable Cox-regression model adjusted for age, sex, type 2 diabetes, history of acute myocardial infarction, hypertension, heart failure, dyslipidemia, cancer, chronic kidney disease, and stroke, the AFâ¼COPD group (HR 1.19, 95% CI 1.16-1.23; P < 0.001) and COPD-First group (HR 1.30, 95% CI 1.27-1.33; P < 0.001) had a higher risk of death compared with the AF-First group. A restricted cubic spline analysis showed that the earlier the COPD was diagnosed, the worse is the prognosis. CONCLUSION: Patients with concomitant AF and COPD had a very poor prognosis and the temporal sequence in diagnosis was differentially associated with prognosis, where a COPD diagnosis preceding an AF diagnosis was accompanied with a higher mortality risk compared with a COPD diagnosis following an AF diagnosis.
Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Doença Pulmonar Obstrutiva Crônica , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Diabetes Mellitus Tipo 2/complicações , Fatores de Risco , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Acidente Vascular Cerebral/complicaçõesRESUMO
AIMS: Cardiac resynchronization therapy (CRT) is highly effective in dilated cardiomyopathy (DCM) patients with impaired left ventricular ejection fraction (LVEF) and left bundle block branch. In cardiac amyloidosis (CA) patients, left ventricular dysfunction and conduction defects are common, but the potential of CRT to improve cardiac remodelling and survival in this particular setting remains undefined. We investigated cardiovascular outcomes in CA patients after CRT implantation in terms of CRT echocardiographic response and major cardiovascular events (MACEs). METHODS AND RESULTS: Our retrospective study included 47 CA patients implanted with CRT devices from January 2012 to February 2020, in nine French university hospitals (77 ± 6 years old, baseline LVEF 30 ± 8%) compared with propensity-matched (1:1 for age, LVEF at implantation, and CRT indication) DCM patients with a CRT device. CA patients had lower rates of CRT response (absolute delta LVEF ≥ 10%) compared with DCM patients (36% vs. 70%, P = 0.002). After multivariate Cox analysis, CA was independently associated with MACE (hospitalization for heart failure/cardiovascular death) [hazard ratio (HR) 3.73, 95% confidence interval (CI) 1.85-7.54, P < 0.001], along with the absence of CRT response (HR 3.01, 95% CI 1.56-5.79, P = 0.001). The presence of echocardiographic CRT response (absolute delta LVEF ≥ 10%) was the only predictive factor of MACE-free survival in CA patients (HR 0.36, 95% CI 0.15-0.86, P = 0.002). CONCLUSION: Compared with a matched cohort of DCM patients, CA patients had a lower rate of CRT response and consequently a worse cardiovascular prognosis after CRT implantation. However, CRT could be beneficial even in CA patients given that CRT response was associated with better cardiac outcomes in this population.
Assuntos
Amiloidose , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Idoso , Idoso de 80 Anos ou mais , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/terapia , Terapia de Ressincronização Cardíaca/métodos , Humanos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Função Ventricular Esquerda/fisiologiaRESUMO
AIMS: Atrial fibrillation (AF) catheter ablation is a common procedure requiring in most cases the use of fluoroscopy. We aimed to evaluate the factors associated with a lower dose of fluoroscopy used during AF ablation with cryoballoon or radiofrequency. METHODS: In this prospective European registry, centers were requested to provide procedural characteristics of consecutive AF ablation cases. Lower doses of fluoroscopy were defined as those with dose-area-product (DAP) under the median dose used in the radiofrequency and the cryoballoon ablation groups. RESULTS: A total of 638 AF ablation procedures were collected (n = 492 for radiofrequency and n = 146 for cryoballoon ablation groups) in 25 centers. The median [IQR] DAP were 926 [349;2092] and 1516 [418;3408] cGy*cm2 in the radiofrequency and cryoballoon groups, respectively. Main factors associated with lower DAP in cryoballoon ablation group were electrophysiology dedicated laboratory (OR 6.04, 95%CI 1.16-31.54; P = .03) and frequent dosimetry report (OR 21.39, 95%CI 5.43-98.54; P = .03). Main factors associated with lower DAP in the radiofrequency ablation group were the use of a chest dosimeter (OR 12.57, 95% CI 2.88-54.90; P = .01), biplane X-ray equipment (OR 3.12, 95%CI 1.89-5.16; P < .01), university hospital (OR 2.10, 95%CI 1.35-3.25; P = .01), electrophysiology dedicated laboratory (OR 2.45, 95%CI 1.48-4.05; P < .01) and use of contact force enabled catheter (OR 22.60, 95%CI 6.82-74.88; P < .01). CONCLUSION: This real-life study of fluoroscopy use during AF ablation provides new data about current practices across European countries. Technological advances and quality of the fluoroscopic environment were the main factors associated with lower radiation dose during AF ablation.
Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Doses de Radiação , Adulto , Idoso , Europa (Continente) , Feminino , Fluoroscopia , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de RegistrosRESUMO
BACKGROUND: The purpose of this study was to analyze electrophysiologists' radiation-protective devices for occupational exposure across European countries. METHODS: Data reported herein were gathered from the international, multicenter prospective Go for Zero Fluoroscopy registry performed in years 2018-2019. The registry encompassed 25 European electrophysiological centers from 14 countries and up to 5 operators from each center. RESULTS: The analysis included 95 operators (median age: 39 years, 85% of male, median training time: 5 years). The most frequently used X-ray protection tools (used by ≥80% of the group) were lead aprons, thyroid shields, screens below the table, glass in the laboratory, and least often (<7%) protective gloves and cabin. No statistically significant differences regarding the number of procedures performed monthly, electrophysiologists' experience and gender, and radiation exposure dose or radiation protection tools were observed, except lead thyroid shields and eyeglasses, which were more often used in case of fewer electrophysiological procedures performed (<20 procedures per month). Operators who were protected by >4 X-ray protection tools were exposed to lower radiation levels than those who were protected by ≤4 X-ray protection tools (median radiation exposure: 0.6 [0.2-1.1] vs. 0.2 [0.1-0.2] mSv per month, p < 0.0001; 1.1 [0.1-12.0] vs. 0.5 [0.1-1.1] mSv per year, p < 0.0001), respectively. CONCLUSIONS: Electrophysiologists' radiation-protective devices for occupational exposure are similar across European centers and in accordance with the applicable X-ray protection protocols, irrespective of the level of experience, number of monthly performed EP procedures, and gender.
Assuntos
Proteção Radiológica , Adulto , Europa (Continente) , Fluoroscopia/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Sistema de RegistrosRESUMO
BACKGROUND: Fluoroscopy has been an essential part of every electrophysiological procedure since its inception. However, till now no clear standards regarding acceptable x-ray exposure nor recommendation how to achieve them have been proposed. HYPOTHESIS: Current norms and quality markers required for optimal clinical routine can be identified. METHODS: Centers participating in this Europe-wide multicenter, prospective registry were requested to provide characteristics of the center, operators, technical equipment as well as procedural settings of consecutive cases. RESULTS: Twenty-five centers (72% university clinics, with a mean volume of 526 ± 348 procedures yearly) from 14 European countries provided data on 1788 cases [9% diagnostic procedures (DP), 38% atrial fibrillation (AF) ablations, 44% other supraventricular (SVT) ablations, and 9% ventricular ablations (VT)] conducted by 95 operators (89% male, 41 ± 7 years old). Mean dose area product (DAP) and time was 304 ± 608 cGy*cm2 , 3.6 ± 4.8 minutes, 1937 ± 608 cGy*cm2 , 15.3 ± 15.5 minutes, 805 ± 1442 cGy*cm2 , 10.6 ± 10.7 minutes, and 1277 ± 1931 cGy*cm2 , 10.4 ± 12.3 minutes for DP, AF, SVT, and VT ablations, respectively. Seven percent of all procedures were conducted without any use of fluoroscopy. Procedures in the lower quartile of DAP were performed more frequently by female operators (OR 1.707, 95%CI 1.257-2.318, P = .001), in higher-volume center (OR 1.001 per one additional procedure, 95%CI 1.000-1.001, P = .002), with the use of 3D-mapping system (OR 2.622, 95%CI 2.053-3.347, P < .001) and monoplane x-ray system (OR 2.945, 95%CI 2.149-4.037, P < .001). CONCLUSION: Exposure to ionizing radiation varies widely in daily practice for all procedure. Significant opportunities for harmonization of exposure toward the lower range has been identified.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fluoroscopia/métodos , Sistema de Registros , Cirurgia Assistida por Computador/métodos , Adulto , Fibrilação Atrial/diagnóstico , Europa (Continente) , Feminino , Humanos , Masculino , Estudos ProspectivosRESUMO
AIMS: Recent trials provide conflicting results on the association between glucagon-like peptide 1 receptor agonists (GLP-1RA) and diabetic retinopathy (DR). The aim of the AngioSafe type 2 diabetes (T2D) study was to determine the role of GLP-1RA in angiogenesis using clinical and preclinical models. METHODS: We performed two studies in humans. In study 1, we investigated the effect of GLP-1RA exposure from T2D diagnosis on the severity of DR, as diagnosed with retinal imaging (fundus photography). In study 2, a randomized 4-week trial, we assessed the effect of liraglutide on circulating hematopoietic progenitor cells (HPCs), and angio-miRNAs.We then studied the experimental effect of Exendin-4, on key steps of angiogenesis: in vitro on human endothelial cell proliferation, survival and three-dimensional vascular morphogenesis; and in vivo on ischemia-induced neovascularization of the retina in mice. RESULTS: In the cohort of 3154 T2D patients, 10% displayed severe DR. In multivariate analysis, sex, disease duration, glycated hemoglobin (HbA1c), micro- and macroangiopathy, insulin therapy and hypertension remained strongly associated with severe DR, while no association was found with GLP-1RA exposure (o 1.139 [0.800-1.622], P = .47). We further showed no effect of liraglutide on HPCs, and angio-miRNAs. In vitro, we demonstrated that exendin-4 had no effect on proliferation and survival of human endothelial cells, no effect on total length and number of capillaries. Finally, in vivo, we showed that exendin-4 did not exert any negative effect on retinal neovascularization. CONCLUSIONS: The AngioSafe T2D studies provide experimental and clinical data confirming no effect of GLP-1RA on angiogenesis and no association between GLP-1 exposure and severe DR.
Assuntos
Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/patologia , Células Endoteliais/efeitos dos fármacos , Exenatida/farmacologia , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Neovascularização Patológica/patologia , Idoso , Animais , Biomarcadores/análise , Glicemia/análise , Diabetes Mellitus Tipo 2/tratamento farmacológico , Retinopatia Diabética/tratamento farmacológico , Retinopatia Diabética/etiologia , Feminino , Seguimentos , Humanos , Hipoglicemiantes/farmacologia , Masculino , Camundongos , Pessoa de Meia-Idade , Morfogênese , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/etiologia , Prognóstico , Retina/efeitos dos fármacos , Retina/metabolismo , Retina/patologiaRESUMO
Screening and diagnosis of atrial fibrillation. Screening for atrial fibrillation (AF) is crucial as this arrhythmia is asymptomatic in a third of patients and 5% of patients present a stroke as the first manifestation of their AF. The European Society of Cardiology recommends opportunistic screening of AF in patients over 65 years of age and systematically in patients over 75 years of age. The simplest way is pulse taking, but the number of connected devices for AF screening allows to multiply the frequency of screening and thus increase sensitivity, with another advantage of a digitalized transmission of the tracing. However many questions remain. No scientific evidence has demonstrated a benefit for AF screening. We do not know what duration and frequency of screening is relevant. The burden of AF which increases thromboembolic risk is not known. What population should be screened and how to consider subclinical AF? We will obtain answers to our questions in the coming years thanks to the results of the various studies in progress.
Dépistage et diagnostic de la fibrillation atriale. Le dépistage de la fibrillation atriale (FA) est primordial, car cette arythmie est asymptomatique chez 15 à 30 % des patients, et 1 patient sur 20 est victime d'un accident vasculaire cérébral comme première manifestation de sa fibrillation. La Société européenne de cardiologie recommande le dépistage de la FA de manière opportuniste chez les plus de 65 ans et de manière systématique chez les plus de 75 ans. Le moyen le plus simple est la prise du pouls, mais les objets connectés permettent dorénavant de multiplier la fréquence de dépistage, et donc d'augmenter la sensibilité, avec aussi l'avantage d'une transmission numérisée du tracé pour la plupart. Enfin, ils sont moins contraignants que les appareils les plus anciens. Toutefois, de nombreuses questions demeurent. Il n'y a pas encore de preuve scientifique ayant démontré un bénéfice du dépistage de la FA. Nous ne savons pas quelle durée et quelle fréquence de dépistage sont pertinentes. La durée de fibrillation à partir de laquelle il existe une augmentation du risque thromboembolique n'est pas connue. Quelle population faut-il dépister et comment faut-il considérer la fibrillation infraclinique ? Nous obtiendrons des réponses à nos interrogations dans les prochaines années grâce aux résultats des différentes études en cours.
Assuntos
Fibrilação Atrial , Cardiologia , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia , Humanos , Programas de Rastreamento , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologiaRESUMO
BACKGROUND: Microvascular obstruction (MVO) is associated with poor outcome after ST-segment elevation myocardial infarction (STEMI). Vascular endothelial growth factor-A (VEGF-A) is a vascular permeability inducer playing a key role in MVO pathogenesis. We aimed to assess whether VEGF-A levels are associated with MVO, when evaluated by magnetic resonance imaging (MRI) in STEMI patients. METHODS: The multicenter prospective PREGICA study included a CMR substudy with all consecutive patients with a first STEMI who had undergone cardiac MRI at baseline and at 6-month follow-up. Patients with initial TIMI flow >1 were excluded. VEGF-A levels were measured in blood samples drawn at inclusion. RESULTS: Between 2010 and 2017, 147 patients (mean age 57⯱â¯10â¯years; 84% males) were included. MVO was present in 65 (44%) patients. After multivariate analysis, higher troponin peak (OR 1.005; 95% CI 1.001-1.008; pâ¯=â¯0.007) and VEGF-A levels (OR 1.003; 95% CI 1.001-1.005; pâ¯=â¯0.015) were independently associated with MVO. When considering only patients with successful percutaneous coronary intervention (final TIMI flow 3, nâ¯=â¯130), higher troponin peak (pâ¯=â¯0.004) and VEGF-A levels (pâ¯=â¯0.03) remained independently predictive of MVO. Moreover, MVO was associated with adverse left ventricular (LV) remodeling and VEGF-A levels were significantly and inversely correlated with LV ejection fraction (EF) at 6-month follow-up. CONCLUSION: Our results show that VEGF-A levels were independently associated with MVO during STEMI and correlated with mid-term LVEF alteration. VEGF-A could therefore be considered as a biomarker of MVO in STEMI patients and be used to stratify patient prognosis.
Assuntos
Oclusão Coronária/sangue , Oclusão Coronária/diagnóstico por imagem , Microcirculação/fisiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Fator A de Crescimento do Endotélio Vascular/sangue , Idoso , Biomarcadores/sangue , Oclusão Coronária/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgiaRESUMO
BACKGROUND: Ventricular arrhythmia is common after left ventricular assist device (LVAD) implantation, especially in the early postoperative phase (<30 days). AIM: To identify the incidence of and risk factors for electrical storm (ES) occurring within 30 days of HeartMate® II implantation. METHODS: We reviewed data from all consecutive patients undergoing HeartMate® II device implantation at our institution from January 2008 to December 2014. Patient demographic data, pharmacotherapies and outcomes were collected. The primary endpoint was occurrence of early ES (within 30 days of surgery), defined as three or more separate episodes of sustained ventricular arrhythmia within a 24-hour interval, requiring appropriate therapy. RESULTS: Forty-three patients (mean age 56.7±11.2 years; 39 men) were included. At HeartMate® II implantation, mean left ventricular ejection fraction was 20±5%, 32 (74.4%) patients had ischaemic cardiomyopathy and 31 (72.1%) were implanted with an indication of bridge to cardiac transplantation. During follow-up, 12 (27.9%) patients experienced early ES after HeartMate® II implantation (median delay 9.1±7.8 days). Early ES was more frequent in larger patients (body surface area 1.99 vs 1.81 m2; P<0.01), tended to be associated with previous sustained ventricular tachycardia (50.0% vs 22.6%; P=0.08), previous implantable cardioverter-defibrillator implantation (66.7% vs 38.7%; P=0.09), discontinuation of long-term beta-blocker therapy (75.0% vs 45.2%; P=0.08), weaning of adrenergic drugs after the third day (66.7% vs 35.5%; P=0.06) and the use of extracorporeal life support (50% vs 22.6%; P=0.079), but was not associated with the cardiomyopathy aetiology or the indication for assistance. Catheter ventricular tachycardia ablation was performed in six (14.0%) patients. Early ES was associated with a significantly higher all-cause mortality rate at the 30th day (33.3% vs 6.5%; P=0.02). CONCLUSION: ES is a common and pejorative feature in the early postoperative period.
Assuntos
Arritmias Cardíacas/epidemiologia , Cardiomiopatias/terapia , Coração Auxiliar , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: Light-chain (AL) amyloidosis can lead to an infiltrative cardiomyopathy with increased wall thickness (IWT) of very poor prognosis. Our primary aim was to analyse the right ventricle (RV) in patients with IWT to discriminate AL amyloidosis from IWT due to hypertrophic cardiomyopathy (HCM) or to arterial hypertension (HTN). Our secondary aim was to assess if RV dysfunction predicts overall mortality in cardiac AL amyloidosis. METHODS: We retrospectively and consecutively compared clinical, biological and echocardiographic data of 315 patients with IWT: 105 biopsy-proven AL amyloidosis patients, 105 patients with HCM and 105 patients with HTN. The prognostic value of these parameters was analysed in the AL amyloidosis group. RESULTS: Free-wall right ventricular longitudinal strain (FWRVLS) worse than -21.2% discriminates AL amyloidosis [area under the curve (AUC) = 0.744)] from patients with IWT due to other aetiologies. In AL amyloidosis, FWRVLS is the strongest echocardiographic prognostic marker with AUC =0.722 and -16.5% as the optimal cut-off value, beyond which overall mortality increases significantly. It is also the only independent echocardiographic predictor of overall mortality (HR =1.113; 95%CI 1.029-1.204; p = .007), even when adjusted to the Mayo stage and global left ventricular longitudinal strain. CONCLUSIONS: FWRVLS should be considered in the diagnostic and prognostic workup in light-chain amyloidosis.
Assuntos
Cardiomiopatias , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Hipertensão , Amiloidose de Cadeia Leve de Imunoglobulina , Idoso , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Cardiomiopatias/mortalidade , Intervalo Livre de Doença , Feminino , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/etiologia , Hipertensão/mortalidade , Amiloidose de Cadeia Leve de Imunoglobulina/complicações , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico por imagem , Amiloidose de Cadeia Leve de Imunoglobulina/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de SobrevidaRESUMO
PURPOSE: Little is presently known about the outcome of atrial lesions performed with high-intensity focused ultrasound (HIFU) for atrial fibrillation ablation. We aimed to assess endocardial atrial lesions 6 months after epicardial HIFU ablation (Epicor(™)) and to evaluate the benefit of a combined ablation approach. METHODS: Thirty patients (21 males, mean age 68 ± 12 years old) undergoing HIFU atrial fibrillation ablation during cardiac surgery were enrolled. Electrophysiological study (EPS) was performed 6 months after HIFU ablation, and endovascular radiofrequency was delivered in case of conduction gaps. Patients were followed up for at least 6 months after the EPS. RESULTS: At EPS, ten patients (38 %) had achieved complete or near-complete "box" isolation and four (15 %) had no visible lesion. Using this technology, freedom from symptomatic atrial arrhythmia at 6 months was 60 % (n = 18/30) (64 % for paroxysmal and 56 % for persistent subgroups) improving to 81 % (n = 21/26) (90 % for paroxysmal and 73 % for persistent subgroups) at 12 months after a facultative percutaneous endocardial approach was performed. Using an UltraCinch device sized below 10 improved the rate of complete lesion as assessed 6 months after surgery (58 % of complete or near-complete box isolation with UltraCinch device <10 vs 21 % when ≥11; p = 0.05). CONCLUSION: Six months after HIFU ablation, only 38 % of the patients had complete or near-complete box isolation, and the recurrence rate of symptomatic atrial arrhythmia was 40 %. The latter was reduced to 19 % 6 months after complementary percutaneous approach.