Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Kardiochir Torakochirurgia Pol ; 14(1): 76-78, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28515757

RESUMO

Left ventricular assist device (LVAD) thrombosis remains a dreadful complication of mechanical circulatory support, with an incidence of 8-12% depending on the pump type and patient's comorbidities. Fibrinolysis may be considered early in pump thrombosis, but when contraindicated a pump exchange remains the only alternative. This short report documents an emergency LVAD exchange in a 55-year-old man who underwent LVAD (HeartWare Inc) implantation in 2013 as a bridge to transplantation. Four months after the initial surgery, he suffered from a hemorrhagic stroke despite properly managed anticoagulation. On February 17th, 2017 he was re-admitted with LVAD pump thrombosis. As fibrinolysis was contraindicated, an emergency pump exchange was performed via a limited thoracic incision in order to minimize surgical trauma, reduce intraoperative complications and facilitate immediate post-operative recovery. This report documents the very first LVAD pump exchange as well as the first one performed via a minimally invasive approach in Poland.

2.
Kardiochir Torakochirurgia Pol ; 13(4): 383-385, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28096843

RESUMO

Myxomas make up about 50% of benign cardiac neoplasms. The most common location is within the left atrium. At the initial stage they do not exhibit any specific clinical symptoms, so they are often diagnosed by accident or during examinations recommended for other reasons. Here we present a case of left atrium myxoma in a patient (a man, age 68 years) with a dual chamber pacemaker. The myxoma did not reveal any clinical symptoms and was discovered in echocardiography during routine diagnostic examination preceding pacemaker implantation. The literature search made by the authors showed that this is the first recorded case of myxoma in a patient after the implantation of a biventricular pacemaker.

3.
Kardiochir Torakochirurgia Pol ; 11(1): 63-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26336397

RESUMO

THE AIM OF THE STUDY: The aim of the study was to determine whether there are any differences in the intima-media thickness (IMT) of carotid arteries between the group of patients with systemic lupus erythematosus (SLE) and the control group, and whether these differences are a consequence of SLE or independent factors of atherosclerosis development. MATERIAL AND METHODS: The patients were divided into three groups: the study group (n = 25, mean age: 39.8 years) consisting of patients suffering from SLE; the subgroup (n = 13, mean age: 39.2 years) consisting of patients suffering only from SLE without any accompanying diseases; and the control group (n = 25, mean age: 37.1 years) consisting of healthy patients (not suffering from SLE or any other disease of the connective tissue). The IMT of the left and right common carotid arteries (LCCA, RCCA) was measured by means of ultrasound. RESULTS: The analysis performed with the Mann-Whitney U test showed that a statistically significant difference of IMT occurs between the control group and the study groups (p = 0.006 for LCCA and p < 0.001 for RCCA), while there is no such relation (p = 0.86 for RCCA and p = 0.095 for LCCA) between the control group and the subgroup. CONCLUSIONS: The group of patients with SLE was found to have an increased IMT in comparison with the reference group. The unfavorable influence of independent factors of atherosclerosis development on the increase of the IMT value in patients with lupus was thus indicated. This observation suggests a faster atherosclerotic process in this group of patients.

4.
Biomed Eng Online ; 11: 72, 2012 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-22998766

RESUMO

BACKGROUND: The paper presents a newly researched acoustic system for blood volume measurements for the developed family of Polish ventricular assist devices. The pneumatic heart-supporting devices are still the preferred solution in some cases, and monitoring of their operation, especially the temporary blood volume, is yet to be solved. METHODS: The prototype of the POLVAD-EXT prosthesis developed by the Foundation of Cardiac Surgery Development, Zabrze, Poland, is equipped with the newly researched acoustic blood volume measurement system based on the principle of Helmholtz's acoustic resonance. The results of static volume measurements acquired using the acoustic sensor were verified by measuring the volume of the liquid filling the prosthesis. Dynamic measurements were conducted on the hybrid model of the human cardiovascular system at the Foundation, with the Transonic T410 (11PLX transducer - 5% uncertainty) ultrasound flow rate sensor, used as the reference. RESULTS: The statistical analysis of a series of static tests have proved that the sensor solution provides blood volume measurement results with uncertainties (understood as a standard mean deviation) of less than 10%. Dynamic tests show a high correlation between the results of the acoustic system and those obtained by flow rate measurements using an ultrasound transit time type sensor. CONCLUSIONS: The results show that noninvasive, online temporary blood volume measurements in the POLVAD-EXT prosthesis, making use of the newly developed acoustic system, provides accurate static and dynamic measurements results. Conducted research provides the preliminary view on the possibility of reducing the additional sensor chamber volume in future.


Assuntos
Acústica/instrumentação , Volume Sanguíneo , Coração Auxiliar , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA